Search PubMed⌕ Search

Biomedical subjects

Ronald K Tessman

Publications and source records attributed to Ronald K Tessman.

4 recordsLinked to original sources

Comparison of the response of primary human blood monocytes and the U937 human monocytic cell line to two different sizes of alumina ceramic particles.

It is well recognized that wear particles derived from orthopaedic implants have the potential to induce inflammation, which may eventually lead to aseptic loosening of the artificial joint. We hypothesized that alumina ceramic particles of different sizes cause a differential cytokine response by human monocytes. To test this hypothesis a human monocytic cell line (U937) and primary human blood monocytes obtained from healthy volunteers were exposed to ceramic particles within the range known to be generated in vivo. Cellular responses were measured by quantifying the relative gene expression of 12 different cytokines using TAQman Real-Time Polymerase Chain Reaction (RT-PCR). Our results demonstrate that at a particle to cell ratio of 100:1, 0.5 microm ceramic particles consistently provoked higher amounts of Interleukin-1alpha (IL-1alpha), IL-1beta, IL-8, IL-10 and Tumor necrosis factor-alpha (TNF-alpha) steady state mRNA by U937 cells. As expected, the variability of cytokine expression in primary blood monocytes was much higher compared to the cell line however, a similar trend was observed. These results show a differential response to ceramic particle size, which may imply that 0.5 microm particles are less biocompatible. New ceramic implants can be designed to generate a known particle size range in vivo. Implant materials of this type may induce relatively lower levels of production of inflammatory cytokines resulting in a reduced incidence of failure due to aseptic loosening.

Aluminum↗

Comparison of refractometers and test endpoints in the measurement of serum protein concentration to assess passive transfer status in calves.

OBJECTIVE: To evaluate 3 refractometers for detection of failure of passive transfer (FPT) of immunity in calves, and assess the effect of refractometric test endpoints on sensitivity, specificity, and proportion of calves classified correctly with regard to passive transfer status. DESIGN: Prospective study. ANIMALS: 90 calves. PROCEDURE: Blood samples were obtained from calves that were < 10 days old. Serum IgG concentration was determined by use of a radial immunodiffusion assay. Accuracy of 3 refractometers in the prediction of serum IgG concentration was determined by use of standard epidemiologic methods and a linear regression model. RESULTS: At a serum protein concentration test endpoint of 5.2 g/dL, sensitivity of each refractometer was 0.89 or 0.93, and specificity ranged from 0.80 to 0.91. For all refractometers, serum protein concentration test endpoints of 5.0 or 5.2 g/dL resulted in sensitivity > 0.80, specificity > 0.80, and proportion of calves classified correctly > 0.85. Serum protein concentrations equivalent to 1,000 mg of IgG/dL of serum were 4.9, 4.8, and 5.1 g/dL for the 3 refractometers. CONCLUSIONS AND CLINICAL RELEVANCE: The refractometers, including a nontemperature-compensating instrument, performed similarly in detection of FPT. Serum protein concentration test endpoints of 5.0 and 5.2 g/dL yielded accurate results in the assessment of adequacy of passive transfer; lower or higher test endpoints misclassified larger numbers of calves.

Animals↗

Serum immunoglobulin G concentrations in calves fed fresh colostrum or a colostrum supplement.

This study compared serum immunoglobulin G (IgG) concentrations in calves fed colostrum with those of calves fed a colostrum supplement containing spray-dried serum. Twenty-four Holstein calves were randomly assigned to I of 2 treatment groups (fresh colostrum or colostrum supplement). Each calf was fed 4 L of colostrum (n, = 12) or 4 L of colostrum supplement (n2 = 12) via oroesophageal intubation at 3 hours of age. The concentration of the colostrum supplement fed to calves was twice the manufacturer's recommendation. The median and range values for colostral IgG concentration were 6,430 mg/dL and 1,400-17,000 mg/ dL, respectively. Median serum IgG concentrations at 2 days of age differed significantly (P = .001) between calves receiving fresh colostrum (3,350 mg/dL) and the colostrum supplement (643 mg/dL). Eight percent of calves force fed colostrum had serum IgG concentrations < 1,000 mg/dL, whereas 75% of calves force-fed supplement had IgG concentrations below this threshold. The calculated population relative risks for mortality associated with passive transfer for calves force-fed colostrum and calves force-fed colostrum supplement were 1.09 and 1.90, respectively. Force-fed fresh colostrum is superior to the colostrum supplement studied, but the colostrum supplement has similar efficacy to routine colostrum administration practices.

Animals↗