Search PubMed⌕ Search

Biomedical subjects

Ron Kikinis

Publications and source records attributed to Ron Kikinis.

At least 55 records · Page 3Linked to original sources

A new visualization technique for laparoscopic ultrasonography.

BACKGROUND: Using laparoscopic ultrasonography (LUS) is challenging for both novice and experienced ultrasonographers. The major difficulty surgeons experience is understanding the orientation of the ultrasonography image. The purpose of this study was to assess whether providing surgeons with orientation information improves their ability to interpret LUS images. METHODS: We performed a LUS examination on a 25-kg pig and simultaneously digitized video from the laparoscopic camera, the LUS, and a novel orientation system. From the video recordings, 12 different clips of intra-abdominal anatomy were prepared. Twenty surgeons (18 staff, 2 fellows) volunteered to participate in an experimental crossover study. Test subjects reviewed the LUS clips along with the laparoscopic video images and the orientation display. Controls reviewed the LUS clips with only the laparoscopic video images. Diagnostic accuracy was compared by using the odds ratio. RESULTS: For all vessels, the orientation display improved the odds ratio for correctly identifying structures from 3.7 to 8.9 (P=.02). For arteries, the orientation display improved the odds ratio from 2.4 to 9.6 (P=.01). For veins, the orientation display improved the odds ratio from 4.4 to 13.6 (P=.04). CONCLUSIONS: Providing orientation information significantly improves a surgeon's ability to interpret LUS images.

Animals↗

Comparison of single-shot echo-planar and line scan protocols for diffusion tensor imaging.

RATIONALE AND OBJECTIVES: Both single-shot diffusion-weighted echo-planar imaging (EPI) and line scan diffusion imaging (LSDI) can be used to obtain magnetic resonance diffusion tensor data and to calculate directionally invariant diffusion anisotropy indices, ie, indirect measures of the organization and coherence of white matter fibers in the brain. To date, there has been no comparison of EPI and LSDI. Because EPI is the most commonly used technique for acquiring diffusion tensor data, it is important to understand the limitations and advantages of LSDI relative to EPI. MATERIALS AND METHODS: Five healthy volunteers underwent EPI and LSDI diffusion on a 1.5 Tesla magnet (General Electric Medical Systems, Milwaukee, WI). Four-mm thick coronal sections, covering the entire brain, were obtained. In addition, one subject was tested with both sequences over four sessions. For each image voxel, eigenvectors and eigenvalues of the diffusion tensor were calculated, and fractional anisotropy (FA) was derived. Several regions of interest were delineated, and for each, mean FA and estimated mean standard deviation were calculated and compared. RESULTS: Results showed no significant differences between EPI and LSDI for mean FA for the five subjects. When intersession reproducibility for one subject was evaluated, there was a significant difference between EPI and LSDI in FA for the corpus callosum and the right uncinate fasciculus. Moreover, errors associated with each FA measure were larger for EPI than for LSDI. CONCLUSION: Results indicate that both EPI- and LSDI-derived FA measures are sufficiently robust. However, when higher accuracy is needed, LSDI provides smaller error and smaller inter-subject and inter-session variability than EPI.

Adult↗

Statistical validation of image segmentation quality based on a spatial overlap index.

RATIONALE AND OBJECTIVES: To examine a statistical validation method based on the spatial overlap between two sets of segmentations of the same anatomy. MATERIALS AND METHODS: The Dice similarity coefficient (DSC) was used as a statistical validation metric to evaluate the performance of both the reproducibility of manual segmentations and the spatial overlap accuracy of automated probabilistic fractional segmentation of MR images, illustrated on two clinical examples. Example 1: 10 consecutive cases of prostate brachytherapy patients underwent both preoperative 1.5T and intraoperative 0.5T MR imaging. For each case, 5 repeated manual segmentations of the prostate peripheral zone were performed separately on preoperative and on intraoperative images. Example 2: A semi-automated probabilistic fractional segmentation algorithm was applied to MR imaging of 9 cases with 3 types of brain tumors. DSC values were computed and logit-transformed values were compared in the mean with the analysis of variance (ANOVA). RESULTS: Example 1: The mean DSCs of 0.883 (range, 0.876-0.893) with 1.5T preoperative MRI and 0.838 (range, 0.819-0.852) with 0.5T intraoperative MRI (P < .001) were within and at the margin of the range of good reproducibility, respectively. Example 2: Wide ranges of DSC were observed in brain tumor segmentations: Meningiomas (0.519-0.893), astrocytomas (0.487-0.972), and other mixed gliomas (0.490-0.899). CONCLUSION: The DSC value is a simple and useful summary measure of spatial overlap, which can be applied to studies of reproducibility and accuracy in image segmentation. We observed generally satisfactory but variable validation results in two clinical applications. This metric may be adapted for similar validation tasks.

Analysis of Variance↗

Patient-specific computational analysis of transvenous defibrillation: a comparison to clinical metrics in humans.

The goal of this study is to assess the predictive capacity of computational models of transvenous defibrillation by comparing the results of patient-specific simulations to clinical defibrillation thresholds (DFT). Nine patient-specific models of the thorax and in situ electrodes were created from segmented CT images taken after implantation of the cardioverter-defibrillator. The defibrillation field distribution was computed using the finite volume method. The DFTs were extracted from the calculated field distribution using the 95% critical mass criterion. The comparison between simulated and clinical DFT energy resulted in a rms difference of 12.4 J and a 0.05 correlation coefficient (cc). The model-predicted DFTs were well matched to the clinical values in four patients (rms = 1.5 J; cc = 0.84). For the remaining five patients the rms difference was 18.4 J with a cc = 0.85. These results suggest that computational models based soley on the critical mass criterion and a single value of the inexcitability threshold are not able to consistently predict DFTs for individual patients. However, inspection of the weak potential gradient field in all nine patients revealed a relationship between the degree of dispersion of the weak field and the clinical DFT, which may help identify high DFT patients.

Adult↗

Structural modeling of dynamic changes in memory and brain structure using longitudinal data from the normative aging study.

This is an application of new longitudinal structural equation modeling techniques to time-dependent associations of memory and brain structure measurements. There were 225 participants aged 30-80 years at baseline who were measured again after a 7-year interval on both the lateral ventricular size and Wechsler memory score. Multiple regression analyses show nonlinear associations with age but no relationships among longitudinal changes. Mixed-effects latent growth curve analyses and analyses based on latent difference scores indicate that longitudinal changes in both variables are reasonably well described by an exponential or dual change model. Bivariate dynamic structural equation modeling analyses indicate age-lagged changes operate in a coupled-over-time fashion, with the brain measure (lateral ventricular size) as a leading indicator in time of memory (Wechsler memory score) declines.

Adult↗

A comparison of biventricular and conventional transvenous defibrillation: a computational study using patient derived models.

Conventional transvenous defibrillation is performed with an ICD using a dual current pathway. The defibrillation energy is delivered from the RV electrode to the superior vena cava (SVC) electrode and the metallic case (CAN) of the ICD. Biventricular defibrillation uses an additional electrode placed in the LV free wall with sequential shocks to create an additional current vector. Clinical studies of biventricular defibrillation have reported a 45% reduction in mean defibrillation threshold (DFT) energy. The aim of the study was to use computational methods to examine the biventricular defibrillation fields together with their corresponding DFTs in a variety of patient derived models and to compare them to simulations of conventional defibrillation. A library of thoracic models derived from nine patients was used to solve for electric field distributions. The defibrillation waveform consisted of a LV --> SVC + CAN monophasic shock followed by a biphasic shock delivered via the RV --> SVC + CAN electrodes. When the initial voltage of the two shocks is the same, the simulations show that the biventricular configuration reduces the mean DFT by 46% (3.5 +/- 1.3 vs 5.5 +/- 2.7 J, P = 0.005). When the leading edge of the biphasic shock is equal to the trailing edge of the monophasic shock, there is no statistically significant difference in the mean DFT (4.9 +/- 1.9 vs 5.5 +/- 2.7 J, P > 0.05) with the DFT decreasing in some patients and increasing in others. These results suggest that patient-specific computational models may be able to identify those patients who would most benefit from a biventricular configuration.

Defibrillators, Implantable↗

Middle and inferior temporal gyrus gray matter volume abnormalities in chronic schizophrenia: an MRI study.

OBJECTIVE: The middle temporal gyrus and inferior temporal gyrus subserve language and semantic memory processing, visual perception, and multimodal sensory integration. Functional deficits in these cognitive processes have been well documented in patients with schizophrenia. However, there have been few in vivo structural magnetic resonance imaging (MRI) studies of the middle temporal gyrus and inferior temporal gyrus in schizophrenia. METHOD: Middle temporal gyrus and inferior temporal gyrus gray matter volumes were measured in 23 male patients diagnosed with chronic schizophrenia and 28 healthy male subjects by using high-spatial-resolution MRI. For comparison, superior temporal gyrus and fusiform gyrus gray matter volumes were also measured. Correlations between these four regions and clinical symptoms were also investigated. RESULTS: Relative to healthy subjects, the patients with chronic schizophrenia showed gray matter volume reductions in the left middle temporal gyrus (13% difference) and bilateral inferior temporal gyrus (10% difference in both hemispheres). In addition, the patients showed gray matter volume reductions in the left superior temporal gyrus (13% difference) and bilateral fusiform gyrus (10% difference in both hemispheres). More severe hallucinations were significantly correlated with smaller left hemisphere volumes in the superior temporal gyrus and middle temporal gyrus. CONCLUSIONS: These results suggest that patients with schizophrenia evince reduced gray matter volume in the left middle temporal gyrus and bilateral reductions in the inferior temporal gyrus. In conjunction with findings of left superior temporal gyrus reduction and bilateral fusiform gyrus reductions, these data suggest that schizophrenia may be characterized by left hemisphere-selective dorsal pathophysiology and bilateral ventral pathophysiology in temporal lobe gray matter.

Adult↗

Method for combining information from white matter fiber tracking and gray matter parcellation.

We introduce a method for combining fiber tracking from diffusion-tensor (DT) imaging with cortical gray matter parcellation from structural high-spatial-resolution 3D spoiled gradient-recalled acquisition in the steady state images. We applied this method to a tumor case to determine the impact of the tumor on white matter architecture. We conclude that this new method for combining structural and DT imaging data is useful for understanding cortical connectivity and the localization of fiber tracts and their relationship with cortical anatomy and brain abnormalities.

Adult↗

Workflow modeling and analysis of computer guided prostate brachytherapy under MR imaging control.

We demonstrate that classical Business Process Reengineering (BPR) methods can be successfully applied to Computer Aided Surgery while increasing safety and efficiency of the overall procedure through an integrated Workflow Management System. Computer guided Prostate Brachytherapy, as a sophisticated treatment by an interdisciplinary team, is perfectly suited to apply our method. Detailed suggestions for improvement of the whole procedure could be derived by our modified BPR method.

Brachytherapy↗

Cingulate fasciculus integrity disruption in schizophrenia: a magnetic resonance diffusion tensor imaging study.

Evidence suggests that a disruption in limbic system network integrity and, in particular, the cingulate gyrus (CG), may play a role in the pathophysiology of schizophrenia; however, the cingulum bundle (CB), the white matter tract furnishing both input and output to CG, and the most prominent white matter fiber tract in the limbic system, has not been evaluated in schizophrenia using the new technology of diffusion tensor imaging (DTI). We used line scan DTI to evaluate diffusion in the CB in 16 male schizophrenia patients and 18 male control subjects, group-matched for age, parental socioeconomic status, and handedness. We acquired 4-mm-thick coronal slices through the entire brain. Maps of fractional anisotropy (FA) were generated to quantify diffusion within the left and right CB on eight slices that included the central portion of the CB. Results showed group differences, bilaterally, in area and mean FA for CB, where patients showed smaller area and less anisotropy than controls. For patients, decreased left CB correlated significantly with attention and working memory measures as assessed by the Wisconsin Card Sorting Test. These data provide strong evidence for CB disruptions in schizophrenia, which may be related to disease-related attention and working memory abnormalities.

Adult↗

Anatomic and physiologic predictors of apnea severity in morbidly obese subjects.

STUDY OBJECTIVES: While obesity is the most common risk factor for the development of obstructive sleep apnea, the correlation between measures of obesity and apnea severity is only moderate. We thus attempted to identify anatomic and physiologic predictors of apnea severity. DESIGN: We combined a careful assessment of upper airway anatomy, upper airway physiology, and ventilatory control in a group of obese individuals to identify predictors of apnea severity. SETTING: Tertiary care academic medical center. PATIENTS: 14 morbidly obese subjects being evaluated for weight-reduction surgery. INTERVENTIONS: N/A MEASUREMENT AND RESULTS: We found no relationship between obesity (weight or body mass index) and apnea severity (respiratory disturbance index, RDI). However, those with severe apnea (RDI > 30) were found to have higher peak genioglossus EMG (GGEMG) (23.5 +/- 1.9 vs. 14.1 +/- 3.7 %max, p = 0.05) and greater airway collapsibility during pulses of negative pressure (7.6 +/- 0.9 vs. 4.4 -/+/-0.7 cmH2O, p =0.02). Airway collapsibility was significantly associated with RDI (r = 0.62, p < 0.01) as was peak GGEMG (r = 0.55, p < 0.05). Of the anatomic variables airway shape (A-P/lateral ratio) and volume change of the pharyngeal airway between total lung capacity and residual volume were different between those with and without severe apnea. Both correlated with RDI (A-P/lateral ratio: r = 0.70, p < 0.01 and volume change: r = 0.77, p < 0.01). CONCLUSIONS: We believe these findings suggest that specific anatomic and physiologic properties of the airway interact with obesity to predispose to the development of airway collapse during sleep.

Adult↗

Differences and similarities in insular and temporal pole MRI gray matter volume abnormalities in first-episode schizophrenia and affective psychosis.

CONTEXT: Whether psychoses associated with schizophrenia and affective disorder represent manifestations of different disorders or the same disorder is an important but unresolved question in psychiatry. Results of previous volumetric magnetic resonance imaging investigations indicate that gray matter volume reductions in neocortical regions may be specific to schizophrenia. OBJECTIVE: To simultaneously evaluate multiple olfactocentric paralimbic regions, which play crucial roles in human emotion and motivation, in first-episode patients with schizophrenia and affective psychosis. DESIGN: A cross-sectional study using high-spatial resolution magnetic resonance imaging in patients with schizophrenia and affective psychosis at their first hospitalization. SETTING: Inpatient units at a private psychiatric hospital. PARTICIPANTS: Fifty-three first-episode patients, 27 with schizophrenia and 26 with affective (mainly manic) psychosis, and 29 control subjects. MAIN OUTCOME MEASURES: Using high-spatial resolution magnetic resonance imaging, the gray matter volumes of 2 olfactocentric paralimbic regions of interest, the insular cortex and the temporal pole, were evaluated. RESULTS: A bilateral volume reduction in insular cortex gray matter was specific to first-episode patients with schizophrenia. In contrast, both first-episode psychosis groups showed a volume reduction in left temporal pole gray matter and an absence of normal left-greater-than-right asymmetry. Region of interest correlations showed that only patients with schizophrenia lacked a positive correlation between left temporal pole and left anterior amygdala-hippocampal complex gray matter volumes, whereas both psychosis groups were similar in lacking normal positive correlations between left temporal pole and left anterior superior temporal gyrus gray matter volumes. CONCLUSIONS: These partially different and partially similar patterns of structural abnormalities in olfactocentric paralimbic regions and their associated abnormalities in other temporolimbic regions may be important factors in the differential and common manifestations of the 2 psychoses.

Acute Disease↗

Fusiform gyrus volume reduction and facial recognition in chronic schizophrenia.

BACKGROUND: The fusiform gyrus (FG), or occipitotemporal gyrus, is thought to subserve the processing and encoding of faces. Of note, several studies have reported that patients with schizophrenia show deficits in facial processing. It is thus hypothesized that the FG might be one brain region underlying abnormal facial recognition in schizophrenia. The objectives of this study were to determine whether there are abnormalities in gray matter volumes for the anterior and the posterior FG in patients with chronic schizophrenia and to investigate relationships between FG subregions and immediate and delayed memory for faces. METHODS: Patients were recruited from the Boston VA Healthcare System, Brockton Division, and control subjects were recruited through newspaper advertisement. Study participants included 21 male patients diagnosed as having chronic schizophrenia and 28 male controls. Participants underwent high-spatial-resolution magnetic resonance imaging, and facial recognition memory was evaluated. Main outcome measures included anterior and posterior FG gray matter volumes based on high-spatial-resolution magnetic resonance imaging, a detailed and reliable manual delineation using 3-dimensional information, and correlation coefficients between FG subregions and raw scores on immediate and delayed facial memory derived from the Wechsler Memory Scale III. RESULTS: Patients with chronic schizophrenia had overall smaller FG gray matter volumes (10%) than normal controls. Additionally, patients with schizophrenia performed more poorly than normal controls in both immediate and delayed facial memory tests. Moreover, the degree of poor performance on delayed memory for faces was significantly correlated with the degree of bilateral anterior FG reduction in patients with schizophrenia. CONCLUSION: These results suggest that neuroanatomic FG abnormalities underlie at least some of the deficits associated with facial recognition in schizophrenia.

Adult↗

Progressive decrease of left Heschl gyrus and planum temporale gray matter volume in first-episode schizophrenia: a longitudinal magnetic resonance imaging study.

BACKGROUND: The Heschl gyrus and planum temporale have crucial roles in auditory perception and language processing. Our previous investigation using magnetic resonance imaging (MRI) indicated smaller gray matter volumes bilaterally in the Heschl gyrus and in left planum temporale in patients with first-episode schizophrenia but not in patients with first-episode affective psychosis. We sought to determine whether there are progressive decreases in anatomically defined MRI gray matter volumes of the Heschl gyrus and planum temporale in patients with first-episode schizophrenia and also in patients with first-episode affective psychosis. METHODS: At a private psychiatric hospital, we conducted a prospective high spatial resolution MRI study that included initial scans of 28 patients at their first hospitalization (13 with schizophrenia and 15 with affective psychosis, 13 of whom had a manic psychosis) and 22 healthy control subjects. Follow-up scans occurred, on average, 1.5 years after the initial scan. RESULTS: Patients with first-episode schizophrenia showed significant decreases in gray matter volume over time in the left Heschl gyrus (6.9%) and left planum temporale (7.2%) compared with patients with first-episode affective psychosis or control subjects. CONCLUSIONS: These findings demonstrate a left-biased progressive volume reduction in the Heschl gyrus and planum temporale gray matter in patients with first-episode schizophrenia in contrast to patients with first-episode affective psychosis and control subjects. Schizophrenia but not affective psychosis seems to be characterized by a postonset progression of neocortical gray matter volume loss in the left superior temporal gyrus and thus may not be developmentally fixed.

Adolescent↗

Spatial normalization of diffusion tensor MRI using multiple channels.

Diffusion Tensor MRI (DT-MRI) can provide important in vivo information for the detection of brain abnormalities in diseases characterized by compromised neural connectivity. To quantify diffusion tensor abnormalities based on voxel-based statistical analysis, spatial normalization is required to minimize the anatomical variability between studied brain structures. In this article, we used a multiple input channel registration algorithm based on a demons algorithm and evaluated the spatial normalization of diffusion tensor image in terms of the input information used for registration. Registration was performed on 16 DT-MRI data sets using different combinations of the channels, including a channel of T2-weighted intensity, a channel of the fractional anisotropy, a channel of the difference of the first and second eigenvalues, two channels of the fractional anisotropy and the trace of tensor, three channels of the eigenvalues of the tensor, and the six channel tensor components. To evaluate the registration of tensor data, we defined two similarity measures, i.e., the endpoint divergence and the mean square error, which we applied to the fiber bundles of target images and registered images at the same seed points in white matter segmentation. We also evaluated the tensor registration by examining the voxel-by-voxel alignment of tensors in a sample of 15 normalized DT-MRIs. In all evaluations, nonlinear warping using six independent tensor components as input channels showed the best performance in effectively normalizing the tract morphology and tensor orientation. We also present a nonlinear method for creating a group diffusion tensor atlas using the average tensor field and the average deformation field, which we believe is a better approach than a strict linear one for representing both tensor distribution and morphological distribution of the population.

Adult↗

Level set-based integration of segmentation and computational fluid dynamics for flow correction in phase contrast angiography.

RATIONALE AND OBJECTIVES: A novel method to correct flow data from magnetic resonance phase contrast (MR-PC) angiography, based on combining computational fluid dynamics and segmentation in a level set framework, was developed and tested in this study. MATERIALS AND METHODS: The MR-PC velocity data was used in a partial differential equation-based level set method for vessel segmentation. The results were supplied as the quantitative description of the vessel wall to the flow field solver using computational fluid dynamics, based on the level set method, to obtain a physically meaningful flow. The most significant characteristic of our novel approach is that it requires light computational loads, especially insofar as it avoids generation of complex computational grid system. The integration of segmentation and computational fluid dynamics in a level set framework is shown to be both robust and economic, and yet yields a physically correct velocity field and optimal vessel geometry. RESULTS: The application to the flow field in a straight tube with circular cross section of constant radius demonstrated the validity of out new approach, especially the treatment of the velocity boundary conditions on the solid wall. Simulation of the velocity field in both common carotid artery and bifurcation of basilar and vertebral arteries, based on clinical MR-PC data, provided with smooth and stable results. CONCLUSION: Applying this procedure to both synthetic and clinical data, significant improvement of the blood velocity field, such as a smooth velocity distribution aligned along the vessels and removal of burst or error vectors, could be observed. This procedure also offers possibilities for improved vessel segmentation.

Basilar Artery↗

Statistical validation based on parametric receiver operating characteristic analysis of continuous classification data.

RATIONALE AND OBJECTIVES: The accuracy of diagnostic test and imaging segmentation is important in clinical practice because it has a direct impact on therapeutic planning. Statistical validations of classification accuracy was conducted based on parametric receiver operating characteristic analysis, illustrated on three radiologic examples, MATERIALS AND METHODS: Two parametric models were developed for diagnostic or imaging data. Example 1: A semi-automated fractional segmentation algorithm was applied to magnetic resonance imaging of nine cases of brain tumors. The tumor and background pixel data were assumed to have bi-beta distributions. Fractional segmentation was validated against an estimated composite pixel-wise gold standard based on multi-reader manual segmentations. Example 2: The predictive value of 100 cases of spiral computed tomography of ureteral stone sizes, distributed as bi-normal after a non-linear transformation, under two treatment options received. Example 3: One hundred eighty cases had prostate-specific antigen levels measured in a prospective clinical trial. Radical prostatectomy was performed in all to provide a binary gold standard of local and advanced cancer stages. Prostate-specific antigen level was transformed and modeled by bi-normal distributions. In all examples, areas under the receiver operating characteristic curves were computed. RESULTS. The areas under the receiver operating characteristic curves were: Example 1: Fractional segmentation of magnetic resonance imaging of brain tumors: meningiomas (0.924-0.984); astrocytomas (0.786-0.986); and other low-grade gliomas (0.896-0.983). Example 3: Ureteral stone size for treatment planning (0.813). Example 2: Prostate-specific antigen for staging prostate cancer (0.768). CONCLUSION: All clinical examples yielded fair to excellent accuracy. The validation metric area under the receiver operating characteristic curves may be generalized to evaluating the performances of several continuous classifiers related to imaging.

Algorithms↗

Tumor detection in the bladder wall with a measurement of abnormal thickness in CT scans.

Virtual cystoscopy is a developing technique for bladder cancer screening. In a conventional cystoscopy, an optical probe is inserted into the bladder and an expert reviews the appearance of the bladder wall. Physical limitations of the probe place restrictions on the examination of the bladder wall. In virtual cystoscopy, a computed tomography (CT) scan of the bladder is acquired and an expert reviews the appearance of the bladder wall as shown by the CT. The task of identifying tumors in the bladder wall has often been done without extensive computational aid to the expert. We have developed an image processing algorithm that aids the expert in the detection of bladder tumors. Compared with an expert observer reading the CT, our algorithm achieves 89% sensitivity, 88% specificity, 48% positive predictive value, and 98% negative predictive value.

Anatomy, Cross-Sectional↗