The effect of dose reduction and feasibility of edge-preserving noise reduction on the detection of liver lesions using MSCT.

The purpose of this study was to assess the effect of dose reduction and the potential of noise reduction filters on image quality and the detection of liver lesions using MSCT. Twenty-nine patients with a total of 40 liver lesions underwent 16-slice CT (120 kV; 180 mAs). Virtual noise was added to CT raw datasets simulating effective mAs levels of 155, 130, 105, 80, 55, 30 and 10 mAs. All datasets were post-processed with an edge-preserving noise-reduction filter (ANR-3D), yielding a total of 15 datasets per patient. Ten radiologists performed independent evaluations of image quality, the presence of liver lesions and diagnostic confidence. Quantitative noise and contrast-to-noise ratios (CNR) were obtained. Superior image quality (P < 0.02), reduction of image noise (P < 0.001) and the increase of lesion-to-liver CNR (P < 0.001) were observed in images processed with the ANR-3D filter. Sensitivity for lesion detection remained unchanged down to 105 mAs (CTDI(w) 6.6 mGy) without filter and 80 mAs (CTDI(w) 5.1 mGy) with ANR-3D. Confidence was rated significantly higher for datasets reconstructed with ANR-3D. The use of a noise-reducing, but edge-preserving filter (ANR-3D) is a promising option to reduce further the radiation dose in liver CT.

Adult↗

Assessment of regional left ventricular function with multidetector-row computed tomography versus magnetic resonance imaging.

This study compares quantitative and qualitative information on global and regional left ventricular (LV) function obtained with multidetector-row computed tomography (MDCT) with that obtained with magnetic resonance imaging (MRI) in patients with a high prevalence of LV wall motion abnormalities. Thirty patients (19 male, 63.7+/-15.1 years) with myocardial infarction (n=12), coronary artery disease (n=9), arrhythmogenic right ventricular cardiomyopathy (n=6), and dilation cardiomyopathy (n=3) were included. Segmental LV wall motion (LV-WM) was assessed using a 4-point scale. Wall thickness measurements were calculated in diastolic and systolic short axis images. Two hundred and fifty-two out of 266 (94.7%) normal and 189 out of 214 (88.3%) segments with decreased wall motion were correctly identified by MDCT, yielding a sensitivity of 88% and specificity of 95% for identification of wall motion abnormalities. LV-WM scores were identical in 86.7% of 480 segments (kappa=0.809). MDCT had a tendency to underestimate the degree of wall motion impairment. Interobserver agreement was lower in MDCT (66.5%) than in MRI (89.1%; p<0.01). Normokinetic segments are reliably identified with MDCT. Sensitivity for detection and accurate classification of LV wall motion abnormalities need to be improved. Better temporal resolution of the CT system seems to be the most important factor for enhancing MDCT performance.

Adrenergic beta-Antagonists↗

Detection of colorectal polyps: comparison of multi-detector row CT and MR colonography in a colon phantom.

PURPOSE: To compare multi-detector row (four- and 16-section) computed tomography (CT), including a low-dose protocol, with high-field-strength (1.5- and 3.0-T) magnetic resonance (MR) imaging for reader detection of colorectal polyps in a colon phantom. MATERIALS AND METHODS: A colon phantom with simulated haustral folds and 10 polyps of varying size (2.0-8.0 mm) was imaged at four- and 16-section CT (section thicknesses of 1.25 and 0.75 mm, reconstruction increments of 0.8 and 0.7 mm, and 100 and 10 mAs, respectively, and 120 kV for both) and at 1.5- and 3.0-T MR imaging (three-dimensional gradient-recalled echo sequence, section thickness of 1.4 mm). Three-dimensional endoluminal images were assessed by 10 reviewers for each modality regarding polyp detection. Comparisons of sensitivities were performed by using logistic regression. RESULTS: Overall, polyps were detected with a sensitivity of 87% (95% confidence interval [CI]: 80%, 94%) at four-section CT, 92% (95% CI: 87%, 97%) at 16-section CT, 56% (95% CI: 46%, 66%) at 1.5-T MR imaging, and 55% (95% CI: 45%, 65%) at 3.0-T MR imaging. The detection of polyps at least 4 mm in diameter was not influenced by the modality or radiation dose (sensitivity of 100%). CT performed in low-dose mode depicted all polyps with a diameter of at least 3 mm. Polyps smaller than 3 mm in diameter were detected with a sensitivity of 7.5% (1.5-T MR imaging), 22.5% (3.0-T MR imaging), and 20% (low-dose CT); detection rates were significantly greater (P < .001) with normal-dose CT (four section, 67.5%; 16 section, 82.5%). Increased spatial resolution (with CT) and higher field strength (with MR imaging) had no significant effect on polyp detection. CONCLUSION: With both multi-detector row CT and MR imaging, readers detected polyps above the clinically relevant threshold diameter of 6 mm, with similar sensitivities.

Colonic Polyps↗

The position of the aorta relative to the spine before and after anterior instrumentation in right thoracic scoliosis.

STUDY DESIGN: Preoperative magnetic resonance images (MRI) and postoperative axial computed tomography (CT) scans in 25 consecutive patients with idiopathic right thoracic adolescent scoliosis (AIS) and anterior correction and fusion with a dual rod system were analyzed in a prospective study. OBJECTIVES: Evaluation of the spatial relations between the vertebral body and the aorta and the relative migration of the aorta due to the anterior correction and instrumentation in right thoracic scoliosis patients. SUMMARY OF BACKGROUND DATA: In anterior scoliosis surgery, bicortical screw purchase is performed to increase pullout strength. However, impingement of the aorta due to excessive contralateral screw penetration has been reported, especially after endoscopic instrumentation. For a safe screw placement, knowledge of both the preoperative topographic relation of aorta and vertebral body and its changes due to surgical correction is crucial. Recent studies reported on a more lateral and posterior position of the aorta in AIS patients. However, there are hardly any data on the changes of the aortic position after anterior curve correction available in the current literature. METHODS: All 25 patients underwent an identical anterior surgical technique with standard open approach and dual rod instrumentation of the primary curve. Preoperative MRI and postoperative sequential CT scans of 180 vertebrae were analyzed with respect to following parameters: vertebral body width and depth, diameter of the aorta, closest distance between aorta and the vertebral body, the aorta-vertebral angle, and the position of the aorta in relation to the spinal canal. RESULTS: Before surgery, the aorta is positioned posterolaterally with an aorta-vertebral angle of between 78 degrees and 92 degrees (between T5 and T10). Between T11 and L2, the aorta is positioned more anteromedially with an aorta-vertebral angle from 62 degrees (T11) to 16 degrees (L2). After surgery, the aorta has migrated from a posterolateral to a more anteromedial position. This migration is maximal at the apex vertebra with an average change of the aorta-vertebral angle of 31.4 degrees . Whereas the distance between the aorta and the vertebral body increases at the upper and lower fusion levels, the aorta moves significantly closer to the vertebral body at the curve apex due to surgical correction. In patients with thoracic hypokyphosis, the aorta is positioned significantly more posterior than in patients with hyperkyphosis. CONCLUSIONS: This MRI and CT based study of 25 patients with thoracic AIS treated by standard open dual rod and dual screw instrumentation demonstrates a migration of the aorta by 31 degrees from a more posterolateral position before surgery to a more anteromedial position after surgery at the curve apex. Scoliosis surgeons should be aware of these changes; any excessive contralateral screw penetration must be avoided at any level.

Adolescent↗

Selective coronary artery plaque visualization and differentiation by contrast-enhanced inversion prepared MRI.

AIMS: We sought to evaluate the utility of contrast-enhanced coronary magnetic resonance imaging (CE-MRI) for selective visualization and non-invasive differentiation of atherosclerotic coronary plaque in humans. METHODS AND RESULTS: Nine patients with coronary artery disease (CAD) as confirmed by X-ray angiography and multidetector computed tomography (MDCT) were studied by T1-weighted black blood inversion recovery coronary MRI before (N-IR) and after administration of Gd-DTPA (CE-IR). Plaques were categorized as calcified, non-calcified, and mixed based on their Hounsfield number derived from MDCT. With MDCT, a total of 29 plaques were identified, including calcified (n=6), non-calcified (n=6), and mixed calcified/non-calcified (n=17). On N-IR MRI, 26 plaques (90%) were dark, whereas three plaques (two non-calcified and one mixed) appeared bright. On CE-MRI, 13/29 (45%) plaques, 11 of which were mixed, one non-calcified, and one calcified showed contrast uptake. All others remained dark. CONCLUSION: In this preliminary study, we demonstrate the potential utility of CE-IR MRI for selective plaque visualization and differentiation of plaque types. The observed contrast uptake may be associated with endothelial dysfunction, neovascularization, inflammation, and/or fibrosis.

Adult↗

Idiopathic left ventricular aneurysm and sudden cardiac death in young adults.

AIMS: We report three young patients presenting with life-threatening ventricular tachycardia (VT) or ventricular fibrillation (VF) and/or survived sudden cardiac arrest, who were admitted to our institution for further diagnostic evaluation. METHODS AND RESULTS: In all patients, idiopathic left ventricular (LV) aneurysms were identified after a detailed non-invasive and invasive evaluation. Sustained VT/VF was inducible during programmed ventricular stimulation in two of the three patients. Left ventricular aneurysms were depicted and characterized by various imaging modalities (echocardiography, magnetic resonance imaging, LV angiography). To elucidate the pathogenesis further, both myocardial viability and regional sympathetic innervation were assessed by radionuclide imaging techniques. Defects of innervation and metabolism were documented in the area of the aneurysm but distal to the aneurysm there were no signs of downstream denervation. CONCLUSION: Life-threatening arrhythmias may be the first manifestation of an idiopathic LV aneurysm, which can be reliably diagnosed with modern imaging techniques. Radionuclide imaging may yield additional information as to the involvement of the autonomic nervous system potentially associated with arrhythmogenesis. Management strategies in patients with an idiopathic LV aneurysm range from antiarrhythmic drug treatment, implantation of an automatic cardioverter-defibrillator to surgical aneurysmectomy.

Adult↗

64- Versus 16-slice CT angiography for coronary artery stent assessment: in vitro experience.

OBJECTIVES: We sought to assess the visualization of different coronary artery stents and the delineation of in-stent stenoses using 64- and 16-slice multidector computed tomography (MDCT). MATERIALS AND METHODS: A total of 15 different coronary stents with a simulated in-stent stenosis were placed in a vascular phantom and scanned with a 16-slice and a 64-slice MDCT at orientations of 0 degree, 45 degrees, and 90 degrees relative to the scanner's z-axis. Visible lumen diameter and attenuation in the stented and the unstented segment of the phantom were measured. Three readers assessed stenosis delineation and visualization of the residual lumen using a 5-point scale. RESULTS: Artificial lumen narrowing (ALN) was significantly reduced with 64-slice CT compared with 16-slice CT. At an angle of 0 degree, 45 degrees, and 90 degrees relative to the scanner's z-axis, the ALN for 16-slice CT was 42.2%, 39.8%, and 44.0% using a slice-thickness of 1.0 mm and 40.9%, 40.4%, and 41.6% using a slice thickness of 0.75 mm, respectively. With 64-slice CT, the ALN was 39.1%, 37.3%, and 36.0% at the respective angles. The differences between attenuation values in the stented and unstented segment of the tube were significantly lower for 64-slice CT. Mean visibility scores were significantly higher for 64-slice CT. CONCLUSION: Use of the 64-slice CT results in superior visualization of the stent lumen and in-stent stenosis compared with 16-slice CT, especially when the stent is orientated parallel to the x-ray beam.

Coronary Angiography↗

Electrocardiogram-independent image reconstruction in cardiac multidetector computed tomography using retrospective motion synchronization.

OBJECTIVE: We sought to evaluate an electrocardiogram (ECG)-independent image reconstruction technique for coronary computed tomography (CT)-angiography based on cardiac motion. MATERIALS AND METHODS: The raw data from 20 patients was reconstructed with both an ECG-gated algorithm and a motion-dependent algorithm that calculates the cardiac motion-function directly from the CT raw data using a center of mass technique. Images were reconstructed in 5% steps over the R-R interval and the cardiac motion-cycle. For both approaches multiplanar reformations were created and the set of images with the least motion artifacts was used for the evaluation. Motion artifacts affecting the ascending aorta, the left main coronary artery and the entire course of the LAD, LCX and RCA were scored using a 5-point scale. RESULTS: The mean optimal reconstruction window was at 60% of the R-R interval and 30% of the cardiac motion cycle. A total of 73 of 100 vascular regions showed no motion artifacts in ECG-gated images, with the motion-synchronized algorithm only 41 regions were free of motion artifacts. The mean motion-score was 1.4 (+/-0.6) and 2.4 (+/-1.2) respectively (P < 0.05). CONCLUSION: In the currently implemented form the motion-gated algorithm is inferior to ECG-gated image reconstruction but can be used in patients with an incomplete or corrupt ECG-signal.

Algorithms↗

MDCT determination of volume and function of the left ventricle: are short-axis image reformations necessary?

OBJECTIVE: Determination of left ventricular (LV) volumes and global function parameters from MDCT data sets is usually based on short-axis reformations from primarily reconstructed axial images, which prolong postprocessing time. The aim of this study was to evaluate the feasibility of LV volumetry and global LV function assessment from axial images in comparison with short-axis image reformations. SUBJECTS AND METHODS: This study consisted of 20 patients with either coronary artery disease or dilated cardiomyopathy. We evaluated MDCT results using cine MRI as the reference technique. RESULTS: LV end-diastolic volume (LVEDV) and end-systolic volume (LVESV) were significantly overestimated by the axial MDCT approach in comparison with volume measurements from short-axis CT image reformations. The mean LV ejection fraction (LVEF) was not significantly different (41.2% vs 42.7%). Short-axis and axial MDCT determination of LVEF revealed a systematic underestimation by a mean +/- SD of -2.1% +/- 3.6% versus -3.6% +/- 8.2%, respectively, when compared with LVEF values based on cine MRI. The interobserver variability for volume and function measurements from axial images (LVEDV = 8.5%, LVESV = 10.8%, LVEF = 9.6%) was slightly higher than those measurements from short-axis reformations (LVEDV = 7.2%, LVESV = 9.5%, LVEF = 8.7%). The mean total evaluation time was significantly shorter using axial images (14.1 +/- 3.9 min) compared with short-axis reformations (16.9 +/- 5.2 min) (p < 0.05). CONCLUSION: Determination of LV volumes and assessment of global LV function from axial MDCT image reformations is feasible and time efficient. This approach might be a clinically useful alternative to established short-axis-based measurements in patients with normal or near-normal LV function. A progressive underestimation of LVEF with increasing LV volumes may limit the clinical applicability of the axial approach in patients with dilated cardiomyopathy.

Cardiomyopathy, Dilated↗

64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents.

The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32 x 0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) medium soft, 0.6, and (4) stent-optimized sharp, 0.6. To evaluate visualization characteristics of of the stent, the lumen diameter, intraluminal density and noise were measured. The high-resolution kernel offered significantly better average lumen visualization (57% +/-10%) and more realistic lumen attenuation (222 HU +/-66 HU) at the expense of increased noise (15.3 HU +/-3.7 HU) compared with the soft and medium-soft CT angiography (CTA) protocol (p<0.001 for all). Stents with a lumen visibility of more than 66% were: Arthos pico, Driver, Flex, Nexus2, S7, Tenax complete, Vision (all 67%), Symbiot, Teneo (70%), and Radius (73%). Only ten stents showed a lumen visibility of less than 50%. Stent lumen visibility largely varies depending on the stent type. Even with the improved spatial resolution of 64-slice CT, a stent-optimized kernel remains beneficial for stent visualization when compared with the standard medium-soft CTA protocol. Using 64-slice CT and high-resolution kernel, the majority of stent products show a lumen visibility of more than 50% of the stent diameter.

Alloys↗

Anterior dual rod instrumentation in idiopathic thoracic scoliosis: a computed tomography analysis of screw placement relative to the aorta and the spinal canal.

STUDY DESIGN: Axial computed tomography scans (CT) in 20 consecutive patients with idiopathic right thoracic scoliosis and anterior correction and fusion with a dual rod dual screw system. OBJECTIVES: CT evaluation of screw position in anterior dual rod instrumentation relative to the aorta and the spinal canal. SUMMARY OF BACKGROUND DATA: In anterior scoliosis surgery, bicortical screw purchase is used to increase pullout strength. However, impingement of the aorta due to excessive contralateral screw penetration has been reported, especially after endoscopic instrumentation. Data on the accuracy of dual screw instrumentation in thoracic scoliosis are missing. METHODS: All 20 patients underwent an identical anterior surgical technique with double thoracotomy approach and dual rod instrumentation of the primary curve. Postoperative sequential CT scans were analyzed with respect to following parameters: vertebral body width and depth, diameter of the aorta, distance from the aorta to the closest point of the vertebral body cortex, distance between the tip of the screws and the aorta, distance between the screw and the spinal canal, and the amount of contralateral screw penetration. A total amount of 226 screws were evaluated. RESULTS: All screws were placed correctly without any critical proximity to the aorta or spinal canal. A total of 198 of 226 screws (88%) had a bicortical purchase. Thirteen screw tips (5.8%) were within 1 to 3 mm proximity to the aorta. All other screws were more than 3 mm distant from the aorta. The closest proximity of the screw tips to the thoracic aorta was found at the upper end vertebrae (T5, T6, or T7). There were no screws perforating the spinal canal. CONCLUSION: Anterior instrumentation and correction of thoracic scoliosis with a dual rod dual screw system enable a correct and safe screw placement using a standard open approach. Excessive bicortical screw perforation should be avoided in order not to endanger the thoracic aorta.

Adolescent↗

Left ventricular function studied with MDCT.

Accurate determination of left ventricular (LV) myocardial function is fundamental for clinical diagnosis, risk stratification, and estimation of prognosis in patients with ischemic and nonischemic cardiomyopathy. Primarily, multi-detector-row spiral CT (MDCT) of the heart aimed at detecting coronary artery obstruction and cardiac morphology. Multiple studies have demonstrated that retrospectively, ECG-gated MDCT determination of LV volumes and consequently global LV function parameters is feasible in good agreement with established imaging modalities such as cineventriculography, echocardiography, and cine magnetic resonance imaging (CMR). Post-processing tools allow fast and semi-automatic determination of LV function parameters from MDCT data in analogy to known CMR evaluation approaches. Although MDCT is not considered to be first-line modality for LV function assessment, this technique provides accessory dynamic information in patients undergoing MDCT coronary angiography, contributing to combined assessment of cardiac morphology and function without need of additional radiation exposure. MDCT regional LV wall motion analysis at rest is feasible, but further improvement in temporal resolution seems mandatory to match results obtained from competing modalities. This paper will discuss the diagnostic potential of MDCT for assessment of LV function with regards to accuracy and clinical applications, as well as limitations, particularly in comparison with CMR as modality of reference.

Cardiac Volume↗

Assessment of coronary artery stents using 16-slice MDCT angiography: evaluation of a dedicated reconstruction kernel and a noise reduction filter.

To compare the effect of different reconstruction kernels and a noise-reducing postprocessing filter on the delineation of coronary artery stents in 16-slice CT-angiography. Ten patients with coronary stents (seven LAD, five RCX and three RCA) were examined with a 16-slice MDCT using standard acquisition parameters. Images were reconstructed using a medium soft (B30f) and a dedicated, edge-enhancing kernel (B46f). Additional postprocessing with an edge-preserving filter was performed on B46f images to reduce the image noise. In multiplanar reformations (MPRs) along and perpendicular to the stent axis, intraluminal attenuation values and the visible lumen diameter were measured. Image noise was measured in the subcutaneous fat using a region of interest (ROI) technique. Arterial enhancement in the aorta was 275.1 HU. Attenuation in the stent lumen was 390.4, 340.0 and 346.8 HU in MPRs derived from B30f, original B46 and postprocessed B46f images. The mean noise level was 20.4, 35.0 and 24.9 HU respectively. The visible lumen diameter was significantly greater in B46f and postprocessed B46f images (2.17 and 2.16 mm), compared to 1.93 mm in B30f images (p<0.01). Edge-enhancing reconstruction kernels increase the visible stent lumen, but also increase image noise. Dedicated postprocessing filters can reduce the introduced noise without a loss of spatial resolution.

Artifacts↗

Further evidence of a close anatomical relation between the oesophagus and pulmonary veins.

BACKGROUND: Atrio-oesophageal fistula has been reported as a rare but life-threatening complication of ablation of atrial fibrillation (AF). Therefore, the position of the oesophagus in relation to the left atrium (LA) is of major importance for AF ablation. METHODS AND RESULTS: In order to investigate the possible anatomical variability between the oesophagus and the left atrium, multidetector-row spiral computed tomography (MDCT) of 60 healthy males (age 58.1+/-5.1 years; LA diameter 5.4+/-0.7 x 3.8+/-0.6 cm; LA volume 60.5+/-15.4 ml) was analyzed. The distance between the oesophagus and the ostia of the pulmonary veins (PV) ranged between 0 and 50.7 mm. Especially for the left PV, the oesophagus was closer than 5 mm to the ostia in 29 cases (48%; n = 24 for left superior PV; n = 10 for left inferior PV; n = 0 for right superior PV; n = 1 for right inferior PV). In addition, the oesophagus was very close to the LA wall (0.8+/-0.9 mm; range 0-3.3 mm). Intraobserver variability was 1.1+/-0.7 mm or 3.5%. CONCLUSION: The position of the oesophagus in relation to the LA and the PV demonstrates high variability. In many cases, the oesophagus is very close to the ostia of the PVs and lies only a short distance from the LA wall. Thus, an anatomical localization of the oesophagus may be critical before or during AF ablation to prevent atrio-oesophageal fistula, especially as there is a need for transmural atrial lesions.

Adult↗

Virtual colonography: identification and differentiation of colorectal lesions using multi-detector computed tomography.

OBJECTIVE: Early detection of precancerous or malignant lesions may be decisive for prognosis of patients with colorectal cancer. In this prospective feasibility study, multi-detector spiral computed tomography (CT) colonography was compared with conventional colonoscopy for the detection of colorectal polyps. MATERIAL AND METHODS: Seventy-eight patients underwent CT colonography (standard colonoscopy preparation, distension with room air, prone and supine position) immediately before colonoscopy. Sixty-five (83%) were asymptomatic screening subjects, while the rest had symptoms suggestive of colorectal disease. Presence, location, and size of lesions were prospectively assessed. Sensitivity, specificity, and positive and negative predictive values of CT colonography were calculated using conventional colonoscopy as the reference standard. RESULTS: Conventional colonoscopy was normal in 52 patients. In 26 patients a total of 49 polyps and 3 carcinomas were identified. All three carcinomas and 39 polyps (80%) were identified by CT colonography. Seven of 7 polyps > or = 10 mm (100%), 13 of 16 polyps of 6 to 9 mm (81%), and 19 of 26 polyps < or = 5 mm (73%) in diameter were identified. Fourteen false-positive findings (10 of which were < or = 5 mm in diameter) were related to 8 patients (specificity at the patient level was 86%). In 10 patients, a total of 10 polyps were missed by CT colonography, 7 of which were < or = 5 mm in diameter. CONCLUSIONS: In this feasibility study, multi-detector spiral CT colonography allows accurate detection of polyps > 5 mm in diameter, but at the expense of low specificity in the small size range.

Colonic Polyps↗

Multi-detector row computed tomography of the heart: does a multi-segment reconstruction algorithm improve left ventricular volume measurements?

A multi-segment cardiac image reconstruction algorithm in multi-detector row computed tomography (MDCT) was evaluated regarding temporal resolution and determination of left ventricular (LV) volumes and global LV function. MDCT and cine magnetic resonance (CMR) imaging were performed in 12 patients with known or suspected coronary artery disease. Patients gave informed written consent for the MDCT and the CMR exam. MDCT data were reconstructed using the standard adaptive cardiac volume (ACV) algorithm as well as a multi-segment algorithm utilizing data from three, five and seven rotations. LV end-diastolic (LV-EDV) and end-systolic volumes and ejection fraction (LV-EF) were determined from short-axis image reformations and compared to CMR data. Mean temporal resolution achieved was 192+/-24 ms using the ACV algorithm and improved significantly utilizing the three, five and seven data segments to 139+/-12, 113+/-13 and 96+/-11 ms (P<0.001 for each). Mean LV-EDV was without significant differences using the ACV algorithm, the multi-segment approach and CMR imaging. Despite improved temporal resolution with multi-segment image reconstruction, end-systolic volumes were less accurately measured (mean differences 3.9+/-11.8 ml to 8.1+/-13.9 ml), resulting in a consistent underestimation of LV-EF by 2.3-5.4% in comparison to CMR imaging (Bland-Altman analysis). Multi-segment image reconstruction improves temporal resolution compared to the standard ACV algorithm, but this does not result in a benefit for determination of LV volume and function.

Adult↗

Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: initial experience.

PURPOSE: To determine left ventricular (LV) volumetric and functional parameters from retrospectively electrocardiographically gated multi-detector row computed tomography (CT) by using semiautomated analysis software and to correlate results with those of magnetic resonance (MR) imaging. MATERIALS AND METHODS: In 30 patients (mean age, 59.2 years +/- 7.1 [SD]) known to have or suspected of having coronary artery disease, four-channel multi-detector row CT was performed with standard technique, and diastolic and systolic image reconstructions were generated. With commercially available analysis software capable of semiautomated contour detection, end diastolic and end systolic LV volumes were determined from short-axis secondary CT reformations. Steady-state free-precession cine MR images were acquired in short-axis orientation within 48 hours and analyzed by using dedicated software. Bland-Altman analysis was performed to calculate limits of agreement and systematic errors between CT and MR imaging. RESULTS: Mean end diastolic (138.8 mL +/- 31.9) and end systolic (53.9 mL +/- 21.2) LV volumes as determined with CT correlated well with MR imaging measurements (142.0 mL +/- 32.5 [r = 0.93] and 54.9 mL +/- 22.8 [r = 0.94], respectively [P <.001]). LV ejection fraction (61.6% +/- 10.6 for CT vs 62.3% +/- 10.1 for MR imaging; r = 0.89) and stroke volume (84.6 mL +/- 20.9 for CT vs 86.9 mL +/- 21.5 for MR imaging; r = 0.88) also showed good correlation (P <.001). Bland-Altman analysis showed acceptable limits of agreement (+/-9.8% for ejection fraction) without systematic errors. CONCLUSION: In selected patients, semiautomated analysis software enables LV volumetric and functional analysis based on multi-detector row CT data sets, the results of which correlate well with MR imaging findings.

Aged↗