Reliable 5-min real-time MR technique for left-ventricular-wall motion analysis.

The aim of this study was to investigate the value of a real-time magnetic resonance imaging (MRI) approach for the assessment of left-ventricular-wall motion in patients with insufficient transthoracic echocardiography in terms of accuracy and temporal expenditure. Twenty-five consecutive patients were examined on a 1.5-Tesla whole-body MR system (ACS-NT, Philips Medical Systems, Best, NL) using a real-time and ECG-gated (the current gold standard) steady-state free-precession (SSFP) sequence. Wall motion was analyzed by three observers by consensus interpretation. In addition, the preparation, scanning, and overall examination times were measured. The assessment of the wall motion demonstrated a close agreement between the two modalities resulting in a mean kappa coefficient of 0.8. At the same time, each stage of the examination was significantly shortened using the real-time MR approach. Real-time imaging allows for accurate assessment of left-ventricular-wall motion with the added benefit of decreased examination time. Therefore, it may serve as a cost-efficient alternative in patients with insufficient echocardiography.

Aged↗

Characterization of myocardial viability using MR and CT imaging.

Cardiovascular magnetic resonance (MR) imaging is of proven clinical value for the noninvasive characterization of myocardial viability. Computed tomography (CT) is also being exploited for this indication. Examples of each of these imaging strategies for the assessment of myocardial viability will be provided in this review. Key MRI concepts and practical considerations such as customized MR imaging techniques and tailored imaging protocols dedicated to viability assessment are outlined with the primary focus on recent developments. Clinical applications of MR-based viability assessment are reviewed, ranging from rapid functional cine imaging to tissue characterization using T2-weighted imaging and T1-weighted late-contrast-enhanced imaging. Next, the merits and limitations of state-of-the-art CT imaging are surveyed, and their implications for viability assessment are considered. The final emphasis is on current trends and future directions in noninvasive viability assessment using MRI and CT.

Contrast Media↗

Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners.

The purpose of this study was to compare the accuracy of an automated volumetry software for phantom pulmonary nodules across various 16-slice multislice spiral CT (MSCT) scanners from different vendors. A lung phantom containing five different nodule categories (intraparenchymal, around a vessel, vessel attached, pleural, and attached to the pleura), with each category comprised of 7-9 nodules (total, n = 40) of varying sizes (diameter 3-10 mm; volume 6.62 mm(3)-525 mm(3)), was scanned with four different 16-slice MSCT scanners (Siemens, GE, Philips, Toshiba). Routine and low-dose chest protocols with thin and thick collimations were applied. The data from all scanners were used for further analysis using a dedicated prototype volumetry software. Absolute percentage volume errors (APE) were calculated and compared. The mean APE for all nodules was 8.4% (+/-7.7%) for data acquired with the 16-slice Siemens scanner, 14.3% (+/-11.1%) for the GE scanner, 9.7% (+/-9.6%) for the Philips scanner and 7.5% (+/-7.2%) for the Toshiba scanner, respectively. The lowest APEs were found within the diameter size range of 5-10 mm and volumes >66 mm(3). Nodule volumetry is accurate with a reasonable volume error in data from different scanner vendors. This may have an important impact for intraindividual follow-up studies.

Analysis of Variance↗

Low tube voltage improves computed tomography imaging of delayed myocardial contrast enhancement in an experimental acute myocardial infarction model.

OBJECTIVE: We sought to evaluate the influence of tube voltage on the visualization of acute myocardial infarction (MI) in cardiac multislice spiral computed tomography (MSCT). MATERIALS AND METHODS: Acute MI was induced in 12 domestic pigs by a 45-minute balloon occlusion of the left anterior descending artery. Delayed enhancement magnetic resonance imaging was performed 15 minutes after the injection of 0.2 mmol/kg Gd-DTPA. On the same day, retrospectively ECG-gated MSCT was performed at 120, 100, and 80 kV (16x0.75mm, 550mAseff.) 15 minutes after the injection of 140 mL of iopromide (1 g/iodine/kg). The pigs were killed and the hearts were excised and stained with 2,3,5-triphenyltetrazolium chloride. The area of acute MI, contrast-to-noise ratio (CNR), and percent signal difference were compared among the different imaging techniques by applying Bland-Altman plots and 2-way analysis of variance. RESULTS: On MSCT at 120, 100, and 80 kV, the respective mean acute MI sizes were 18.4+/-11.4%, 19.3+/-11.5%, and 20.5+/-11.6%. The mean MI sizes were 20.8+/-12.2% and 20.1+/-12.4% on magnetic resonance imaging and 2,3,5-triphenyltetrazolium chloride staining. Analysis of variance did not show any statistically significant differences between the different techniques with respect to the size of acute MI (P=0.9880). Comparing the different kV settings on MSCT, the highest percent signal difference (74.7+/-12.1%) and the highest CNR (6.7+/-1.8) between infarcted and healthy remote myocardium were achieved at 80 kV. CONCLUSIONS: When compared with routine scan protocols, low tube voltage MSCT allows for the assessment of the MI size with an improved CNR and contrast resolution. This technique appears to be advantageous for assessing myocardial viability from contrast enhanced late-phase MSCT.

Animals↗

Quantitative prediction of contrast enhancement from test bolus data in cardiac MSCT.

The purpose of this study was to evaluate a new algorithm for the prediction of contrast enhancement from test bolus data in cardiac multislice spiral computed tomography (MSCT). An algorithm for the prediction of contrast enhancement using test bolus data was developed. A total of 30 consecutive patients (15 male, 69.5 +/- 9.6 years) underwent cardiac MSCT (12 x 0.75 mm, 120 kV, 500 mAs(eff.)) with a biphasic contrast material injection protocol. Contrast timing was derived from a standard 20 ml test bolus injection. Based on the test bolus time attenuation curves, expected enhancement values were computed for the ascending and descending aorta and the pulmonary trunk and compared with measured data from the cardiac CT scan. At the level of the test bolus measurement in the ascending aorta, the corresponding attenuation values were 309.4 +/- 49.6 Hounsfield Units (HU) for the predicted and 285.6 +/- 42.6 HU for the measured attenuation, respectively. The mean deviation between predicted and measured CT values was 32.8 +/- 48.2 HU (upper and lower limits of agreement 101.4/-53.8 HU), indicating a slight systematic tendency for overestimation. For 80% of the patients the prediction error was less than 50 HU. Prediction of contrast enhancement in cardiac MSCT from test bolus data is feasible with a relatively small mean deviation; 80% of the predictions were within a range that might be acceptable for routine clinical application.

Aged↗

Cardiac CT: coronary arteries and beyond.

Multi-detector-row computed tomography (MDCT) has emerged as a rapidly developing method for non-invasive imaging of the heart. An understanding of ECG synchronization, contrast material administration, patient preparation and image post-processing is needed to optimize image quality. The basic technical principles and essentials of these technical basics are described here. Correctly applied cardiac MDCT allows imaging of the coronary arteries including coronary anatomy and stenosis detection. The same is true for evaluation of coronary artery bypass grafts and, to some extent, coronary artery stents. While quantification of total calcified plaque burden has been long established, coronary MDCT allows assessing plaque morphology and constitution. Recent approaches go beyond the coronaries and include evaluation of left ventricular function at rest and myocardial viability. In combination with experimental approaches for assessing aortic valve function and myocardial perfusion imaging, cardiac MDCT offers the potential for a comprehensive examination of the heart using a single breath-hold examination.

Calcinosis↗

Asbestos Surveillance Program Aachen (ASPA): initial results from baseline screening for lung cancer in asbestos-exposed high-risk individuals using low-dose multidetector-row CT.

The purpose of this study was to assess the prevalence of lung cancer in a high-risk asbestos-exposed cohort using low-dose MDCT. Of a population of 5,389 former power-plant workers, 316 were characterized as individuals at highest risk for lung cancer according to a lung-cancer risk model including age, asbestos exposure and smoking habits. Of these 316, 187 (mean age: 66.6 years) individuals were included in a prospective trial. Mean asbestos exposure time was 29.65 years and 89% were smokers. Screening was performed on a 16-slice MDCT (Siemens) with low-dose technique (10/20 mAs(eff.); 1 mm/0.5 mm increment). In addition to soft copy PACS reading analysis on a workstation with a dedicated lung analysis software (LungCARE; Siemens) was performed. One strongly suspicious mass and eight cases of histologically proven lung cancer were found plus 491 additional pulmonary nodules (average volume: 40.72 ml, average diameter 4.62 mm). Asbestos-related changes (pleural plaques, fibrosis) were visible in 80 individuals. Lung cancer screening in this high-risk cohort showed a prevalence of lung cancer of 4.28% (8/187) at baseline screening with an additional large number of indeterminate pulmonary nodules. Low-dose MDCT proved to be feasible in this highly selected population.

Aged↗

Prevalence and clinical importance of aortic valve calcification detected incidentally on CT scans: comparison with echocardiography.

PURPOSE: To evaluate retrospectively the prevalence and grade of aortic valve calcification incidentally detected on chest multi-detector row computed tomographic (CT) scans and to compare the grade of calcification with the severity of aortic valve disease as assessed with echocardiography. MATERIALS AND METHODS: Patient informed consent was waived by the institutional board on medical ethics that approved this study. The authors identified 402 patients (231 men and 171 women; mean age, 62.5 years +/- 12.1) of 1820 patients who underwent chest multi-detector row CT between July 2001 and August 2004 and also underwent echocardiography. Aortic valve calcification at multi-detector row CT was visually graded on a scale ranging from 0 to 4 (0 = no calcification, 4 = severe calcification). CT findings were correlated with hemodynamic data obtained at echocardiography. Patients without aortic stenosis were compared with patients with aortic stenosis. The Student t test, Spearman correlation coefficient, chi(2) analysis, and an unweighted kappa test were used to compare results. RESULTS: Aortic valve calcification was noted on multi-detector row CT scans in 72 of the 402 patients (18%). Twelve of 20 patients (60%) with grade 3 or grade 4 calcification on CT scans had aortic stenosis at echocardiography, compared with only nine of 382 patients (2.4%) with grade 0-2 calcification (P < .001). Significant correlations were observed between the grade of aortic valve calcification and the echocardiographically determined mean (r = 0.45, P = .03) and peak transvalvular gradient (r = 0.47, P = .03). There was substantial agreement between the grade of valve calcification at multi-detector row CT and the severity of aortic valve disease at echocardiography (kappa = 0.67). CONCLUSION: Aortic valve calcification was an incidental finding on 18% of multi-detector row CT scans. The grade of aortic valve calcification is correlated with the hemodynamic severity of aortic valve disease as determined with echocardiography.

Aortic Valve↗

Temporary pulmonary stent placement as emergency treatment of pulmonary embolism: first experimental evaluation.

OBJECTIVES: We aimed to evaluate the performance of a newly designed temporary stent device as a percutaneous emergency treatment of pulmonary embolism. BACKGROUND: If thrombolysis is contraindicated or recanalization by thrombolysis delayed in patients with severe pulmonary embolism who are threatened by acute circulatory failure, percutaneous temporary pulmonary stent placement may represent an additional option before surgical embolectomy is considered. METHODS: The newly designed temporary pulmonary stent is made from woven Nitinol and has a distal blunt end and a proximal crimped end, which is firmly fixed to a 0.035-inch guidewire. It is delivered through a 9.5-F polytetrafluoroethylene sheath using a pusher tube. Stent placement and removal were examined in 9 anesthetized sheep with experimentally induced pulmonary embolism. Hemodynamic parameters were recorded in 7 animals. RESULTS: Delivery and removal of the stent was uneventful and rapidly accomplished. Stent placement was associated with a significant decrease in Miller angiographic index (from 11.2 +/- 3.1 to 3.8 +/- 1.9; p = 0.0001), heart rate (from 139 +/- 35 beats/min to 92 +/- 11 beats/min; p = 0.0129), and mean pulmonary artery pressure (from 32 +/- 14 mm Hg to 21 +/- 14 mm Hg; p = 0.0029) and a significant increase in mean aortic pressure (from 48 +/- 14 mm Hg to 61 +/- 8 mm Hg; p = 0.0080). Autopsy revealed neither wall damage nor parenchymal hemorrhage. CONCLUSIONS: Our preliminary study proves the technical feasibility of temporary placement and removal of a newly designed dedicated pulmonary stent to recanalize centrally located embolic occlusions in severe pulmonary embolism. Animal experimental evaluation revealed rapid and significant circulatory improvement after stent placement.

Animals↗

The accuracy of 1- and 3-mm slices in coronary calcium scoring using multi-slice CT in vitro and in vivo.

The accuracy of coronary calcium scoring using 16-row MSCT comparing 1- and 3-mm slices was assessed. A thorax phantom with calcium cylinder inserts was scanned applying a non-enhanced retrospectively ECG-gated examination protocol: collimation 12 x 0.75 mm; 120 kV; 133 mAs(eff). Thirty-eight patients were examined using the same scan protocol. Image reconstruction was performed with an effective slice thickness of 3 and 1 mm. The volume score, calcium mass and Agatston score were determined. Image noise was measured in both studies. The volume score and calcium mass varied less than the Agatston score. The overall measured calcium mass compared to the actual calcium mass revealed a relative difference of +2.0% for 1-mm slices and -1.2% for 3-mm slices. Due to increased image noise in thinner slices in the patient study (26.1 HU), overall calcium scoring with a scoring threshold of 130 HU was not feasible. Interlesion comparison showed significantly higher scoring results for thinner slices (all P<0.001). A similar accuracy comparing calcium scoring results of 1- and 3-mm slices was shown in the phantom study; therefore, the potentially necessary increase of the patient's dose in order to achieve assessable 1-mm slices with an acceptable image-to-noise-ratio appears not to be justified.

Aged↗

Value of virtual tracheobronchoscopy and bronchography from 16-slice multidetector-row spiral computed tomography for assessment of suspected tracheobronchial stenosis in children.

PURPOSE: To evaluate the value of dose-reduced 16-slice multidetector-row spiral computed tomography (16-MDCT) using virtual tracheobronchoscopy (VTB) and virtual bronchography (VBG) in children with suspected tracheobronchial stenosis. MATERIALS AND METHODS: 12 children (4 d to 3 years, body weight 1.2 kg to 13.5 kg) with stridor and suspected tracheobronchial stenosis were examined by contrast-enhanced low-dose 16-MDCT. Conventional axial slices, MPRs, VTB, and VBG were calculated. Image findings were correlated with the results of fiberoptic bronchoscopy (12 out of 12) as a gold standard and subsequent surgery (8 out of 12). RESULTS: VTB and VBG demonstrated the fiberoptic bronchoscopically suspected tracheal stenosis in 11 of 12 children due to vascular compression because of the brachiocephalic trunk (6), a double aortic arch (2), a vascular compression of the left main bronchus (2), and a right aberrant subclavian artery (1). Eleven out of 12 stenoses were correctly depicted by conventional axial slices, MPRs, VTB, and VBG. Dose reduction was 79 to 85.8% compared to a standard adult chest CT. CONCLUSION: Dose-reduced 16-MDCT with the use of VTB and VBG is effective for the evaluation of tracheobronchial stenosis in children and correlates well with fiberoptic bronchoscopy.

Airway Obstruction↗

Automated vs. manual assessment of left ventricular function in cardiac multidetector row computed tomography: comparison with magnetic resonance imaging.

We compared semiautomatic contour detection and manual contour tracing in cardiac multidetector row computed tomography (MDCT) with magnetic resonance imaging (MRI) for calculation of left-ventricular (LV) volumes. The study included 30 patients who underwent contrast-enhanced cardiac MDCT and cardiac cine-MRI. Were calculated 8 mm short-axis slices from MDCT data using three-dimensional multiphase image reconstruction. LV volumes including peak ejection rate and peak filling rate were calculated from manually and semiautomatically determined contours. Results were compared to those from cine-MRI with manually drawn contours as the standard of reference. We found good agreement for the LV volumes, with an ejection fraction of 47.1+/-9.4% for manually drawn contours, 47.9+/-9.9% for semiautomatically detected contours on MDCT, and 48.0+/-10.2% for MRI. Except for peak-filling rate analysis of variance revealed no difference between any of these techniques. Bland-Altman plots and Lin's concordance correlation coefficient showed best agreement between MRI and manual contour tracing in MDCT. Calculation of LV volumes using either semiautomatic or manual contour tracing in cardiac MDCT is therefore feasible when compared to MRI. Automated contour detection needs to be improved to equal manual contour tracing.

Algorithms↗

MR coronary vessel wall imaging: comparison between radial and spiral k-space sampling.

PURPOSE: To compare radial and spiral k-space sampling in navigator-gated ECG-triggered three-dimensional (3D) coronary vessel wall imaging. MATERIALS AND METHODS: The right coronary artery (RCA) vessel walls of eight healthy subjects were imaged using a modified double-inversion prepulse in concert with radial and spiral data acquisition. For data analysis, two investigators blinded to the sequence parameters subjectively assessed image quality in terms of artifacts and vessel wall visualization. Objective measures of the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and vessel wall definition were also determined. RESULTS: Radial k-space sampling demonstrated fewer artifacts and led to improved visualization of the coronary vessel wall compared to spiral imaging (P < 0.05). This finding was also reflected in a better vessel wall definition using radial data acquisition (P < 0.05). SNR and CNR were found to be higher when spiral k-space sampling was used (n.s.). CONCLUSION: Radial k-space sampling in concert with free-breathing navigator-gated cardiac-triggered MRI of the coronary vessel wall resulted in fewer motion artifacts and improved vessel wall definition compared to spiral k-space sampling. The proposed approach therefore appears to be preferable.

Adult↗

Three-dimensional X-ray coronary angiography in the porcine model: A feasibility study.

RATIONALE AND OBJECTIVES: Three-dimensional high-spatial-resolution angiograms of the coronary arteries were acquired with an electrocardiogram-gated three-dimensional rotational angiography technique on an interventional X-ray system. MATERIALS AND METHODS: During selective injection of contrast material in the left and right coronary artery, projection images were obtained in eight pigs during a continuous rotation of the X-ray gantry over an angular range of 180 degrees within 8 seconds. RESULTS: Three-dimensional tomographic reconstruction depicted the proximal, medial, and distal sections of the main arteries as well as the main bifurcations in multiple cardiac phases in all animals. CONCLUSIONS: For the first time, this feasibility study shows that a three-dimensional angiogram of the coronary arteries can be obtained intraprocedurally in a conventional interventional suite by means of tomographic reconstruction from projection images.

Algorithms↗

Variability of aortic valve calcification measurement with multislice spiral computed tomography.

OBJECTIVES: We sought to assess the variability of aortic valve calcifications (AVCs) regarding the reconstruction window at different heart phases using multislice-spiral computed tomography. MATERIALS AND METHODS: A total of 46 patients (26 men; mean age. 65 years) underwent AVC scoring with multislice-spiral computed tomography (12 x 0.75 mm, 120 kV, 133 mAseff). Image reconstruction was performed every 10% of the RR-interval (0-90%). AVC was quantified using Agatston score, calcium volume, and calcium mass. Images were assessed for least motion artifacts. Coefficients of variation and Wilcoxon test were calculated. RESULTS: AVC scores are lowest at 60% and highest at 0% of the RR-interval (P < 0.001). Mean coefficients of variation were 36.2% (Agatston score), 38.7% (calcium volume), and 32.9% (calcium mass). At 60% (50-70%). minimal motion artifacts and the lowest variability of the scores were found. CONCLUSIONS: AVC scores show large variability depending on the point of image reconstruction. Diastolic image reconstruction at 60% of the RR-interval is recommended.

Adult↗

Influence of heart rate and temporal resolution on left-ventricular volumes in cardiac multislice spiral computed tomography: a phantom study.

PURPOSE: We sought to investigate the influence of heart rate and temporal resolution on the assessment of left-ventricular (LV) function with multislice spiral computed tomography (CT). MATERIAL AND METHODS: A dynamic cardiac phantom was repeatedly scanned with a 64-slice CT scanner using a standardized scan protocol (64 x 0.6 mm, 120kV, 770mAs(eff), 330 milliseconds rotation time) at different simulated heart rates, ranging from 40 to 140 beats per minute. Images were reconstructed with an algorithm utilizing data from 1 to 4 cardiac cycles (RR intervals). Ejection fraction (EF), end-systolic, end-diastolic, and stroke volume as well as cardiac output were calculated. Results of the measurements were compared with the real volumes of the phantom. Interscan and intraobserver variability were calculated. RESULTS: Using a monosegmental reconstruction algorithm, the temporal resolution was fixed to 165 milliseconds. With bi-, tri-, and quad-segmental image reconstruction, mean temporal resolution was 128.3 +/- 33.2 milliseconds, 103.3 +/- 49.2 milliseconds, and 87.8 +/- 81.5 milliseconds, respectively. Multisegmental image reconstruction resulted in a lower deviation when comparing measured and real volumes. Using mono-, bi-, tri-, and quad-segmental image reconstruction, the percent deviation between measured and real values for EF was 8.2%, 4.5%, 3.3%, and 3.4%, respectively. Applying multisegmental image reconstruction with improved temporal resolution the deviation decreased with increasing heart rate when compared with mono-segmental image reconstruction. Interscan and intraobserver variability for EF were 1.1% and 1.9%, respectively. CONCLUSION: Enhanced temporal resolution improves the quantification of LV volumes in cardiac multislice spiral CT, enabling reliable assessment of LV volumes even at increased heart rates.

Algorithms↗

Coronary artery calcium scoring with multislice computed tomography: in vitro assessment of a low tube voltage protocol.

OBJECTIVES: We sought to compare an 80-kVp coronary calcium scoring protocol with the standard protocol of 120 kVp in terms of accuracy and reproducibility and to assess its dose reduction potential. MATERIALS AND METHOD: An anthropomorphic heart phantom with calcium cylinders was scanned with different tube currents at 80 kVp and 120 kVp using a 16-slice multislice CT (MSCT) scanner. An adapted threshold for 80 kVp was calculated. Accuracy and reproducibility for calcium mass, volume, and Agatston score were analyzed using F-tests. The radiation doses needed to produce artifact-free images were determined. RESULTS: Accuracy (measurement errors: mass 120 kVp +4.6%, mass 80 kVp -6.9%, volume 120 kVp +78.8%, volume 80 kVp +58.2%) and reproducibility (F-tests: mass: P = 0.4998, volume: P = 0.9168, Agatston: P = 0.5422) were comparable at both tube voltages. Avoiding the appearance of artificial lesions, a CTDI(w,eff) of 10.7 mGy was needed at 120 kVp versus 4.6 mGy at 80 kVp (dose reduction of 57%). CONCLUSIONS: Using an 80-kVp protocol in coronary calcium scoring, a relevant dose reduction is possible without compromising reproducibility and accuracy.

Analysis of Variance↗

Evaluation of a newly developed percutaneous thrombectomy basket device in sheep with central pulmonary embolisms.

OBJECTIVE: The authors studied the development of a thrombectomy device that is adequately steerable and quickly placeable in case of extensive pulmonary embolism. MATERIALS AND METHODS: The device consists of a self-expandable nitinol basket mounted at a catheter-tip, which allows suction and extraction of thrombus material. Five in vitro tests were performed followed by tests in 6 sheep. In vivo thrombus material was introduced through a jugular vein to produce pulmonary embolism. After catheter insertion over the right femoral vein, the basket was placed adjacent to the pulmonary embolus and the extraction procedure was performed. RESULTS: In in vitro tests, the extracted thrombus amount varied between 60% and 95%. In animal experiments, the extracted amount varied between 30% and 95% as determined angiographically. Limiting factors were steerability and optimal positioning of the basket in relation to the embolus. CONCLUSIONS: Extraction of pulmonary embolism with the self-expanding suction basket is feasible. However, successful recanalization is limited by catheter maneuverability in the pulmonary arterial system.

Animals↗