Subconductance states of Cx30 gap junction channels: data from transfected HeLa cells versus data from a mathematical model.

Human HeLa cells expressing mouse connexin30 were used to study the electrical properties of gap junction channel substates. Experiments were performed on cell pairs using a dual voltage-clamp method. Single-channel currents revealed discrete levels attributable to a main state, a residual state, and five substates interposed, suggesting the operation of six subgates provided by the six connexins of a gap junction hemichannel. Substate conductances, gamma(j,substate), were unevenly distributed between the main-state and the residual-state conductance (gamma(j,main state) = 141 pS, gamma(j,residual state) = 21 pS). Activation of the first subgate reduced the channel conductance by approximately 30%, and activation of subsequent subgates resulted in conductance decrements of 10-15% each. Current transitions between the states were fast (<2 ms). Substate events were usually demarcated by transitions from and back to the main state; transitions among substates were rare. Hence, subgates are recruited simultaneously rather than sequentially. The incidence of substate events was larger at larger gradients of V(j). Frequency and duration of substate events increased with increasing number of synchronously activated subgates. Our mathematical model, which describes the operation of gap junction channels, was expanded to include channel substates. Based on the established V(j)-sensitivity of gamma(j,main state) and gamma(j,residual state), the simulation yielded unique functions gamma(j,substate) = f(V(j)) for each substate. Hence, the spacing of subconductance levels between the channel main state and residual state were uneven and characteristic for each V(j).

Animals↗

The relative myocardial blood volume differentiates between hypertensive heart disease and athlete's heart in humans.

AIMS: The adaptation of the myocardial microcirculation in humans to pathologic and physiologic stress has not been examined in vivo so far. We sought to test whether the relative blood volume (rBV) measured by myocardial contrast echocardiography (MCE) can differentiate between left ventricular (LV) hypertrophy (LVH) in hypertensive heart disease and athlete's heart. METHODS AND RESULTS: Four groups were investigated: hypertensive patients with LVH (n = 15), semi-professional triathletes with LVH (n = 15), professional football players (n = 15), and sedentary control individuals without cardiovascular disease (n = 15). MCE was performed at rest and during adenosine-induced hyperaemia. The rBV (mL mL(-1)), its exchange frequency (beta, min(-1)), and myocardial blood flow (mL min(-1) g(-1)) were derived from steady state and refill sequences of ultrasound contrast agent. Hypertensive patients had lower rBV (0.093 +/- 0.013 mL mL(-1)) than triathletes (0.141 +/- 0.012 mL mL(-1), P < 0.001), football players (0.129 +/- 0.014 mL mL(-1), P < 0.001), and sedentary individuals (0.126 +/- 0.018 mL mL(-1), P < 0.001). Conversely, the exchange frequency (beta) was significantly higher in hypertensive patients (11.3 +/- 3.8 min(-1)) than in triathletes (7.4 +/- 1.8 min(-1)), football players (7.7 +/- 2.3 min(-1)), and sedentary individuals (9.0+/-2.5 min(-1)). An rBV below 0.114 mL mL(-1) distinguished hypertensive patients and triathletes with a sensitivity of 93% and a specificity of 100%. CONCLUSION: Pathologic and physiologic LVH were differentiated non-invasively and accurately by rBV, a measure of vascularisation assessed by MCE.

Adult↗

Transcatheter repair of iatrogenic left ventricular free-wall perforation.

Left ventricular free-wall perforation can complicate catheter-based diagnostic or interventional procedures and may require immediate needle pericardiocentesis followed by surgical repair in about 20% of the cases. We describe the transcatheter closure of a left ventricular free-wall perforation as an option in the event of maintained access to the perforation site after defect creation.

Aged↗

Iron heart.

Explore the source record for details and available documents.

Atrial Appendage↗

Collateral-flow measurements in humans by myocardial contrast echocardiography: validation of coronary pressure-derived collateral-flow assessment.

AIMS: Myocardial blood flow (MBF) is the gold standard to assess myocardial blood supply and, as recently shown, can be obtained by myocardial contrast echocardiography (MCE). The aims of this human study are (i) to test whether measurements of collateral-derived MBF by MCE are feasible during elective angioplasty and (ii) to validate the concept of pressure-derived collateral-flow assessment. METHODS AND RESULTS: Thirty patients with stable coronary artery disease underwent MCE of the collateral-receiving territory during and after angioplasty of 37 stenoses. MCE perfusion analysis was successful in 32 cases. MBF during and after angioplasty varied between 0.060-0.876 mL min(-1) g(-1) (0.304+/-0.196 mL min(-1) g(-1)) and 0.676-1.773 mL min(-1) g(-1) (1.207+/-0.327 mL min(-1) g(-1)), respectively. Collateral-perfusion index (CPI) is defined as the rate of MBF during and after angioplasty varied between 0.05 and 0.67 (0.26+/-0.15). During angioplasty, simultaneous measurements of mean aortic pressure, coronary wedge pressure, and central venous pressure determined the pressure-derived collateral-flow index (CFI(p)), which varied between 0.04 and 0.61 (0.23+/-0.14). Linear-regression analysis demonstrated an excellent agreement between CFI(p) and CPI (y=0.88 x +0.01; r(2)=0.92; P<0.0001). CONCLUSION: Collateral-derived MBF measurements by MCE during angioplasty are feasible and proved that the pressure-derived CFI exactly reflects collateral relative to normal myocardial perfusion in humans.

Blood Flow Velocity↗

The quantification of absolute myocardial perfusion in humans by contrast echocardiography: algorithm and validation.

OBJECTIVES: We sought to test whether myocardial blood flow (MBF) can be quantified by myocardial contrast echocardiography (MCE) using a volumetric model of ultrasound contrast agent (UCA) kinetics for the description of refill curves after ultrasound-induced microsphere destruction. BACKGROUND: Absolute myocardial perfusion or MBF (ml.min(-1).g(-1)) is the gold standard to assess myocardial blood supply, and so far it could not be obtained by ultrasound. METHODS: The volumetric model yielded MBF = rBV.beta/rho(T), where rho(T) equals tissue density. The relative myocardial blood volume rBV and its exchange frequency beta were derived from UCA refill sequences. Healthy volunteers underwent MCE and positron emission tomography (PET) at rest (group I: n = 15; group II: n = 5) and during adenosine-induced hyperemia (group II). Fifteen patients with coronary artery disease underwent simultaneous MCE and intracoronary Doppler measurements before and during intracoronary adenosine injection. RESULTS: In vitro experiments confirmed the volumetric model and the reliable determination of rBV and beta for physiologic flow velocities. In group I, 187 of 240 segments were analyzable by MCE, and a linear relation was found between MCE and PET perfusion data (y = 0.899x + 0.079; r(2) = 0.88). In group II, resting and hyperemic perfusion data showed good agreement between MCE and PET (y = 1.011x + 0.124; r(2) = 0.92). In patients, coronary stenosis varied between 0% to 89%, and myocardial perfusion reserve was in good agreement with coronary flow velocity reserve (y = 0.92x + 0.14; r(2) = 0.73). CONCLUSIONS: The volumetric model of UCA kinetics allows the quantification of MBF in humans using MCE and provides the basis for the noninvasive and quantitative assessment of coronary artery disease.

Adenosine↗

Risk of decompression illness among 230 divers in relation to the presence and size of patent foramen ovale.

BACKGROUND: The risk of developing decompression illness (DCI) in divers with a patent foramen ovale (PFO) has not been directly determined so far; neither has it been assessed in relation to the PFO's size. METHODS: In 230 scuba divers (age 39+/-8 years), contrast trans-oesophageal echocardiography (TEE) was performed for the detection and size grading (0-3) of PFO. Prior to TEE, the study individuals answered a detailed questionnaire about their health status and about their diving habits and accidents. For inclusion into the study, > or =200 dives and strict adherence to decompression tables were required. RESULTS: Sixty-three divers (27%) had a PFO. Overall, the absolute risk of suffering a DCI event was 2.5 per 10(4) dives. There were 18 divers (29%) with, and 10 divers (6%) without, PFO who had experienced > or =1 major DCI events P=0.016. In the group with PFO, the incidence per 10(4) dives of a major DCI, a DCI lasting longer than 24 h and of being treated in a decompression chamber amounted to 5.1 (median 0, interquartile range [IQR] 0-10.0), 1.9 (median 0, IQR 0-4.0) and 3.6 (median 0, IQR 0-9.8), respectively and was 4.8-12.9-fold higher than in the group without PFO (P<0.001). The risk of suffering a major DCI, of a DCI lasting longer than 24 h and of being treated by recompression increased with rising PFO size. CONCLUSION: The presence of a PFO is related to a low absolute risk of suffering five major DCI events per 10(4) dives, the odds of which is five times as high as in divers without PFO. The risk of suffering a major DCI parallels PFO size.

Decompression Sickness↗

The electrical behaviour of rat connexin46 gap junction channels expressed in transfected HeLa cells.

Pairs of human HeLa cells expressing rat connexin46 were used to study the electrical properties of gap junction channels with the dual voltage-clamp method. The steady-state conductance ( g(j,ss)) had a bell-shaped dependence on transjunctional voltage ( V(j)). The parameters of the Boltzmann fit were: V(j,0)=42 mV, g(j,min)=0.12, z=2.5 (pipette solution: K(+) aspartate(-); 27 degrees C). The Boltzmann parameters were sensitive to the ionic composition of the pipette solution (KCl, K(+) aspartate(-), TEA(+) Cl(-), TEA(+) aspartate(-)). The V(j)-dependent inactivation of the junctional current I(j) was approximated by single exponentials (exceptions: two exponentials with KCl at V(j)>or=75 mV and K(+) aspartate(-) at V(j)=125 mV). The time constant of inactivation (tau(i)) decreased with increasing V(j) and was sensitive to the pipette solution. The larger the ions, the slower the inactivation. Recovery from inactivation followed a single exponential. The time constant of recovery (tau(r)) increased with increasing V(j). Single-channel currents showed a main state, several substates and a residual state. The corresponding conductances gamma(j,main) and gamma(j,residual) decreased slightly with increasing V(j); extrapolation to V(j)=0 mV yielded values of 152 and 28 pS, respectively (K(+) aspartate(-); 37 degrees C). The values of gamma(j,main) and gamma(j,residual) were dependent on pipette solution. The ratio gamma(j,main)/gamma(j,residual) increased with increasing ionic size, suggesting that the residual state impairs ion permeation more severely than the main state. The gamma(j,main) data suggest that the ionic selectivity of Cx46 channels may be controlled primarily by ionic size. Compared with hemichannel results, docking of connexons may modify the channel structure and thereby affect the ionic selectivity of gap junction channels. The open channel probability at steady state ( P(o)) decreased with increasing V(j). The parameters of the Boltzmann fit were: V(j,0)=41 mV, z=2.2 (K(+) aspartate(-); 27 degrees C).

Algorithms↗

The electrophysiology of gap junctions and gap junction channels and their mathematical modelling.

In most tissues of vertebrates, gap junctions control the exchange of ions and small molecules between adjacent cells, thus co-ordinating the cellular activities. The application of the dual voltage-clamp method to cell pair preparations enables one to elucidate the electrical properties of gap junctions and gap junction channels. The conductive and kinetic data obtained at the multichannel and single channel level led to a generalised concept for the operation of gap junction channels. Based on the biological data gained in this way, a mathematical model has been developed. This model is versatile and allows to simulate the electrophysiological behaviour of different types of vertebrate gap junctions.

Animals↗