Search PubMed⌕ Search

Biomedical subjects

Rolf Lamerichs

Publications and source records attributed to Rolf Lamerichs.

7 recordsLinked to original sources

In vitro demonstration using 19F magnetic resonance to augment molecular imaging with paramagnetic perfluorocarbon nanoparticles at 1.5 Tesla.

OBJECTIVES: This study explored the use of F spectroscopy and imaging with targeted perfluorocarbon nanoparticles for the simultaneous identification of multiple bio-signatures at 1.5 T. MATERIALS AND METHODS: Two nanoparticle emulsions with perfluoro-15-crown-5-ether (CE) or perfluorooctylbromide (PFOB) cores were targeted in vitro to fibrin clot phantoms (n=12) in 4 progressive ratios using biotin-avidin interactions. The CE nanoparticles incorporated gadolinium. Fluorine images were acquired using steady-state gradient-echo techniques; spectra using volume-selective and nonselective sampling. RESULTS: On conventional T1-weighted imaging, clots with CE nanoparticles enhanced as expected, with intensity decreasing monotonically with CE concentration. All clots were visualized using wide bandwidth fluorine imaging, while restricted bandwidth excitation permitted independent imaging of CE or PFOB nanoparticles. Furthermore, F imaging and spectroscopy allowed visual and quantitative confirmation of relative perfluorocarbon nanoparticle distributions. CONCLUSIONS: F MRI/S molecular imaging of perfluorocarbon nanoparticles in vitro suggests that noninvasive phenotypic characterization of pathologic bio-signatures is feasible at clinical field strengths.

Animals↗

Optimizing PRESS localized citrate detection at 3 Tesla.

Analytical methods are used to characterize the response of the strongly coupled two-spin system of citrate to point-resolved spectroscopy (PRESS)-based sequences at 3 T. The signal output is analyzed line by line, as well as in the Cartesian product operator basis. Patterns with a periodicity of 80.9 ms are identified. Furthermore, it is shown that at TE = n . 80.9 ms (n in {0,1,2,...}), the spin evolution can be described without direct reference to strong coupling terms. The theoretical results are found to be in good agreement with in vivo experiments. These results can be used to design protocols for prostate MRS and MRSI at 3 T, and give guidelines for optimizing spin-echo-based acquisition schemes for detecting two-spin systems at arbitrary field strengths.

Adult↗

1H metabolite relaxation times at 3.0 tesla: Measurements of T1 and T2 values in normal brain and determination of regional differences in transverse relaxation.

PURPOSE: To measure 1H relaxation times of cerebral metabolites at 3 T and to investigate regional variations within the brain. MATERIALS AND METHODS: Investigations were performed on a 3.0-T clinical whole-body magnetic resonance (MR) system. T2 relaxation times of N-acetyl aspartate (NAA), total creatine (tCr), and choline compounds (Cho) were measured in six brain regions of 42 healthy subjects. T1 relaxation times of these metabolites and of myo-inositol (Ins) were determined in occipital white matter (WM), the frontal lobe, and the motor cortex of 10 subjects. RESULTS: T2 values of all metabolites were markedly reduced with respect to 1.5 T in all investigated regions. T2 of NAA was significantly (P < 0.001) shorter in the motor cortex (247 +/- 13 msec) than in occipital WM (301 +/- 18 msec). T2 of the tCr methyl resonance showed a corresponding yet less pronounced decrease (162 +/- 16 msec vs. 178 +/- 9 msec, P = 0.021). Even lower T2 values for all metabolites were measured in the basal ganglia. Metabolite T1 relaxation times at 3.0 T were not significantly different from the values at 1.5 T. CONCLUSION: Transverse relaxation times of the investigated cerebral metabolites exhibit an inverse proportionality to magnetic field strength, and especially T2 of NAA shows distinct regional variations at 3 T. These can be attributed to differences in relative WM/gray matter (GM) contents and to local paramagnetism.

Adult↗

Catheter tracking and visualization using 19F nuclear magnetic resonance.

This work presents an investigation into catheter visualization and localization using 19F nuclear magnetic resonance (NMR) in conjunction with proton imaging. For this purpose, the imaging capabilities of a standard system were extended to allow for 19F excitation and signal detection. Two modes of operation were implemented: 1) a real-time tracking mode that provides tip tracking and automatic slice position updates interleaved with real-time, interactive proton imaging; and 2) a non-real-time catheter length visualization mode in which the entire length of a catheter can be assessed. Initial phantom experiments were conducted with the use of an angiographic balloon catheter filled with the blood substitute perfluorooctylbromide (PFOB). Using limited bandwidth excitation centered at the resonances of the CF2 groups of PFOB, we found that sufficient signal could be received to facilitate tip tracking during catheter motion and length visualization for various catheter configurations. The present approach is considered a promising alternative to existing methods, which either are associated with safety concerns (if active markers are employed) or suffer from insufficient, direction-dependent contrast (if passive visualization is used). Furthermore, our approach enables visualization of the entire length of the catheter. The proposed method provides a safe technique that, unlike electrical or optical devices, does not require modification of commercially available catheters.

Catheterization↗

Initial experiences with in vivo right coronary artery human MR vessel wall imaging at 3 tesla.

Due to their relatively small size and central location within the thorax, improvement in signal-to-noise (SNR) is of paramount importance for in vivo coronary vessel wall imaging. Thus, with higher field strengths, coronary vessel wall imaging is likely to benefit from the expected "near linear" proportional gain in SNR. In this study, we demonstrate the feasibility of in vivo human high field (3 T) coronary vessel wall imaging using a free-breathing black blood fast gradient echo technique with respiratory navigator gating and real-time motion correction. With the broader availability of more SNR efficient fast spin echo and spiral techniques, further improvements can be expected.

Adult↗

Regional N-acetylaspartate reduction in the hippocampus detected with fast proton magnetic resonance spectroscopic imaging in patients with Alzheimer disease.

OBJECTIVE: To detect regional metabolic changes that resemble the expected spatial pattern of neuronal loss in patients with Alzheimer disease (AD). METHODS: Thirty-four patients with AD and 22 healthy control subjects were included in the study. Single-slice fast proton spectroscopic imaging was performed in parallel angulation to the temporal lobes. Proton spectra were selected from the hippocampus, the lateral temporal lobe, and the occipital lobe of both hemispheres to determine metabolite concentration of N-acetylaspartate (NAA), total creatine (tCr), including phosphocreatine and creatine, and choline-containing compounds (Cho). The metabolic ratios of NAA/tCr and Cho/tCr were calculated and compared between patients with AD and healthy volunteers. RESULTS: The NAA/tCr ratios were significantly reduced in the left (F(1,1) = 4.34, P =.04) and right hippocampus (F(1,1) = 9.96, P =.003) in patients with AD. The Cho/tCr ratios remained unchanged in both hippocampi. There was no significant change of either NAA/tCr or Cho/tCr in the lateral temporal and occipital lobes of patients with AD. CONCLUSION: This study provides evidence that fast proton spectroscopic imaging may detect the regional pattern of disturbed neuronal integrity in patients with AD with high spatial resolution in a short acquisition time.

Aged↗

Preliminary report on in vivo coronary MRA at 3 Tesla in humans.

Current limitations of coronary magnetic resonance angiography (MRA) include a suboptimal signal-to-noise ratio (SNR), which limits spatial resolution and the ability to visualize distal and branch vessel coronary segments. Improved SNR is expected at higher field strengths, which may provide improved spatial resolution. However, a number of potential adverse effects on image quality have been reported at higher field strengths. The limited availability of high-field systems equipped with cardiac-specific hardware and software has previously precluded successful in vivo human high-field coronary MRA data acquisition. In the present study we investigated the feasibility of human coronary MRA at 3.0 T in vivo. The first results obtained in nine healthy adult subjects are presented.

Adult↗