Search PubMed⌕ Search

Biomedical subjects

Rolf Clackdoyle

Publications and source records attributed to Rolf Clackdoyle.

4 recordsLinked to original sources

Cone-beam reconstruction using the backprojection of locally filtered projections.

This paper describes a flexible new methodology for accurate cone beam reconstruction with source positions on a curve (or set of curves). The inversion formulas employed by this methodology are based on first backprojecting a simple derivative in the projection space and then applying a Hilbert transform inversion in the image space. The local nature of the projection space filtering distinguishes this approach from conventional filtered-backprojection methods. This characteristic together with a degree of flexibility in choosing the direction of the Hilbert transform used for inversion offers two important features for the design of data acquisition geometries and reconstruction algorithms. First, the size of the detector necessary to acquire sufficient data for accurate reconstruction of a given region is often smaller than that required by previously documented approaches. In other words, more data truncation is allowed. Second, redundant data can be incorporated for the purpose of noise reduction. The validity of the inversion formulas along with the application of these two properties are illustrated with reconstructions from computer simulated data. In particular, in the helical cone beam geometry, it is shown that 1) intermittent transaxial truncation has no effect on the reconstruction in a central region which means that wider patients can be accommodated on existing scanners, and more importantly that radiation exposure can be reduced for region of interest imaging and 2) at maximum pitch the data outside the Tam-Danielsson window can be used to reduce image noise and thereby improve dose utilization. Furthermore, the degree of axial truncation tolerated by our approach for saddle trajectories is shown to be larger than that of previous methods.

Algorithms↗

A two-step Hilbert transform method for 2D image reconstruction.

The paper describes a new accurate two-dimensional (2D) image reconstruction method consisting of two steps. In the first step, the backprojected image is formed after taking the derivative of the parallel projection data. In the second step, a Hilbert filtering is applied along certain lines in the differentiated backprojection (DBP) image. Formulae for performing the DBP step in fanbeam geometry are also presented. The advantage of this two-step Hilbert transform approach is that in certain situations, regions of interest (ROIs) can be reconstructed from truncated projection data. Simulation results are presented that illustrate very similar reconstructed image quality using the new method compared to standard filtered backprojection, and that show the capability to correctly handle truncated projections. In particular, a simulation is presented of a wide patient whose projections are truncated laterally yet for which highly accurate ROI reconstruction is obtained.

Algorithms↗

Inversion of the 3D exponential x-ray transform for a half equatorial band and other semi-circular geometries.

This work presents new mathematical results on the inversion of the exponential x-ray transform. It is shown that a reconstruction formula can be obtained for any dataset whose projection directions consist of a union of half great circles on the unit sphere. A basic example of such a dataset is the semi-equatorial band. The discussion in the paper is mostly focused on this example. The reconstruction formula takes the form of a Neumann (geometric) series and is both exact and stable. The exponential x-ray transform has been mainly studied in SPECT imaging. In this context, our results demonstrate mathematically that fully 3D image reconstruction in SPECT with non-zero attenuation does not always require symmetric datasets (opposing views).

Algorithms↗

Image reconstruction from fan-beam projections on less than a short scan.

This work is concerned with 2D image reconstruction from fan-beam projections. It is shown that exact and stable reconstruction of a given region-of-interest in the object does not require all lines passing through the object to be measured. Complete (non-truncated) fan-beam projections provide sufficient information for reconstruction when 'every line passing through the region-of-interest intersects the vertex path in a non-tangential way'. The practical implications of this condition are discussed and a new filtered-backprojection algorithm is derived for reconstruction. Experiments with computer-simulated data are performed to support the mathematical results.

Algorithms↗