Search PubMed⌕ Search

Biomedical subjects

Roland Felix

Publications and source records attributed to Roland Felix.

At least 55 records · Page 3Linked to original sources

A clinical water-coated antenna applicator for MR-controlled deep-body hyperthermia: a comparison of calculated and measured 3-D temperature data sets.

A magnetic resonance (MR)-compatible three-dimensional (3-D) hyperthermia applicator was developed and evaluated in the magnetic resonance (MR) tomograph Siemens MAGNETOM Symphony 1.5 T. Radiating elements of this applicator are 12 so-called water coated antenna (WACOA) modules, which are designed as specially shaped and adjustable dipole structures in hermetically closed cassettes that are filled by deionized water. The WACOA modules are arranged in the applicator frame in two transversal antenna subarrays, six antennas per subarray. As a standard load for the applicator an inhomogeneous phantom was fabricated. Details of applicator's realization are presented and a 3-D comparison of calculated and measured temperature data sets is made. A fair agreement is achieved that demonstrates the numerically supported applicator's ability of phase-defined 3-D pattern steering. Further refinement of numerical models and measuring methods is necessary. The applicator's design and the E-field calculations were performed using the finite-difference time-domain (FDTD) method. The calculation and optimization of temperature patterns was obtained using the finite element method (FEM). For MR temperature measurements the proton resonance frequency (PRF) method was used.

Computer Simulation↗

CT-guided interstitial single-fraction brachytherapy of lung tumors: phase I results of a novel technique.

PURPOSES: To assess the safety of CT-guided brachytherapy of lung malignancies and to evaluate the initial therapeutic response. PATIENTS AND METHODS: Fifteen patients with 30 lung malignancies were included in this prospective phase I trial (metastases, 28; non-small cell lung cancers, 2). Pre-interventionally two patients had a vital capacity of < 80% (39% and 63%). These two patients, and one other, had FEV1 values of < 80% predicted (17%, 48%, and 64%). Tumors with a maximum diameter of 4 cm were treated with a single brachytherapy catheter that was positioned under CT-fluoroscopy. In two tumors with tumor diameters of 5.5 and 6.5 cm, two applicators were used. In one patient with an 11-cm irregularly shaped tumor, nine catheters were inserted. Treatment planning for 192Ir brachytherapy was performed using three-dimensional CT data that were acquired after percutaneous applicator positioning. All procedures were performed under local anesthesia. A follow-up CT was performed 6 weeks later and every 3 months pos-tintervention. RESULTS: The mean diameter of the 30 lung tumors was 2 cm (range, 0.6 to 11 cm; median diameter, 1.5 cm). The minimal dose within the tumor margin was 20 Gy in all 30 tumors treated. Except for nausea in one patient and focal hemorrhage detected on CT in two patients, no acute adverse events were recorded. One patient developed an abscess at the previous tumor location 9 months after treatment, which proved to be a local tumor recurrence. The median follow-up period was 5+ months with a local tumor control of 97%. CONCLUSION: The novel technique of CT-guided interstitial brachytherapy was safe for the treatment of lung tumors and yielded a very low complication rate. The initial data on therapeutic response are promising.

Adult↗

MRI of prostate cancer at 1.5 and 3.0 T: comparison of image quality in tumor detection and staging.

OBJECTIVE: This prospective study was performed to compare the image quality, tumor delineation, and depiction of staging criteria on MRI of prostate cancer at 1.5 and 3.0 T. SUBJECTS AND METHODS: Twenty-four patients with prostate cancer underwent MRI at 1.5 T using the combined endorectal-body phased-array coil and at 3.0 T using the torso phased-array coil, among them 22 before undergoing radical prostatectomy. The prostate was imaged with T2-weighted sequences in axial and coronal orientations at both field strengths and, in addition, with an axial T1-weighted sequence at 1.5 T. Preoperative analysis of all MR images taken together was compared with the histologic findings to determine the accuracy of MRI for the local staging of prostate cancer. In a retroanalysis, the image quality, tumor delineation, and conspicuity of staging criteria were determined separately for both field strengths and compared. Statistical analysis was performed using Wilcoxon's and the McNemar tests. RESULTS: In the preoperative analysis, MRI (at both 1.5 and 3.0 T) had an accuracy of 73% for the local staging of prostate cancer. The retroanalysis yielded significantly better results for 1.5-T MRI with the endorectal-body phased-array coil in terms of image quality (p < 0.001) and tumor delineation (p = 0.012) than for 3.0-T MRI with the torso phased-array coil. Analysis of the individual staging criteria for extracapsular disease did not reveal a superiority of either of the two field strengths in the depiction of any of the criteria. CONCLUSION: Intraindividual comparison shows that image quality and delineation of prostate cancer at 1.5 T with the use of an endorectal coil in a pelvic phased-array is superior to the higher field strength of 3.0 T with a torso phased-array coil alone. As long as no endorectal coil is available for 3-T imaging, imaging at 1.5 T using the combined endorectal-body phased-array coil will continue to be the gold standard for prostate imaging.

Aged↗

Assessment of coronary artery stent patency by electron-beam CT.

Following coronary angioplasty and stent implantation, restenosis remains common and its outcome difficult to predict. We set out to determine the diagnostic accuracy of electron-beam computed tomography (EBCT) for the non-invasive detection of stent obstruction. In a prospective, blinded investigation, we included 152 coronary artery segments in 117 patients treated with a stent implant. All segments were evaluated by a dynamic EBCT study that depicted contrast bolus passage distal to the stent and a CT angiographic study of the entire coronary arteries. It was found that delayed contrast enhancement in the distal segment correlated with angiographic stent obstruction (Spearman's rank correlation, P=0.008), while all other indicators of stent occlusion did not correlate with angiographic diagnosis. However, direct comparison of patients with obstruction of less vs. more than 75% of luminal diameter did not yield any statistically significant differences of distal enhancement delay, and for the detection of >90% occlusion, the sensitivity was 72% at a specificity of 60%. Although delayed contrast enhancement distal to the stent upon EBCT did correlate with angiographical obstruction, the correlation did not suffice to appear clinically satisfactory.

Adult↗

CT-guided interstitial brachytherapy of liver malignancies alone or in combination with thermal ablation: phase I-II results of a novel technique.

PURPOSE: To assess the safety and efficacy of CT-guided brachytherapy alone or in combination with laser-induced thermotherapy (LITT) in patients with liver malignancies. METHODS AND MATERIALS: Thirty-seven patients presented with 36 liver metastases and two primary liver carcinomas. Twenty-one patients were treated with CT-guided high-dose-rate brachytherapy alone using a 192Ir source. Sixteen patients received brachytherapy directly after MRI-guided LITT. The indications for brachytherapy alone were a tumor size >5 cm, adjacent central bile duct or adjacent major vessels causing unfavorable cooling effects for thermal ablation, and technical failures of LITT. The dosimetry for brachytherapy was performed using three-dimensional CT data acquired after percutaneous applicator positioning. On average, a minimal dose of 17 Gy inside the tumor margin was applied (range, 10-20 Gy). RESULTS: The mean tumor size was 4.6 cm (range, 2.5-11 cm). The mean liver volume receiving > or =5 Gy was 16% (range, 2-40%) of the total liver. Severe complications were recorded in 2 patients (5%). One patient developed acute liver failure possibly related to accidental continuation of oral capecitabine treatment. Another patient demonstrated obstructive jaundice owing to tumor edema after irradiation of a metastasis adjacent to the bile duct bifurcation. A commonly encountered moderate increase of liver enzymes was greatest in patients with combined treatment. The local control rate after 6 months was 73% and 87% for combined treatment and brachytherapy alone, respectively. CONCLUSION: CT-guided brachytherapy using three-dimensional CT data for dosimetry is safe and effective alone or in combination with LITT. Brachytherapy as a stand-alone treatment displayed genuine advantages over thermal tumor ablation.

Adult↗

Response prediction by FDG-PET after neoadjuvant radiochemotherapy and combined regional hyperthermia of rectal cancer: correlation with endorectal ultrasound and histopathology.

Accurate response assessment after neoadjuvant therapy is essential in patients with rectal cancer. The aim of this study was to assess the value of fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) in predicting response of locally advanced rectal cancer to preoperative multimodal treatment. Twenty-two consecutive patients with locally advanced (uT3/4) primary rectal cancer were entered in this prospective pilot study. FDG-PET was performed before and after neoadjuvant radiochemotherapy (RCT) with combined regional hyperthermia (RHT). Treatment consisted of external-beam radiotherapy (45 Gy), chemotherapy (folinic acid and 5-fluorouracil) and regional pelvic hyperthermia followed by curative tumour resection 6-8 weeks later. Semi-quantitative measurements (SUV) of tumour FDG uptake were made before and 2-4 weeks after completion of neoadjuvant treatment. Two patients who did not receive post-therapeutic restaging by FDG-PET were excluded from the analysis. Results were correlated with findings on endorectal ultrasound (EUS, n=17 patients) and histopathology. Histopathological evaluation of the resected tumour revealed complete response in one patient, partial response in 12 and stable disease in seven. SUV reduction in tumours was significantly greater in responders than in non-responders [60% (+/-15%) vs 30% (+/-18%), P=0.003, CI=95%). Using a minimum post-therapeutic SUV reduction of 36% to define response, FDG-PET revealed a sensitivity of 100% (EUS: 33%) and a specificity of 86% (EUS: 80%) in response prediction; the corresponding positive and negative predictive values were 93% (EUS: 80%) and 100% (EUS: 33%), respectively. FDG-PET results were statistically significant (P<0.001, CI=95%). FDG-PET has great potential in the assessment of tumour response to neoadjuvant RCT in combination with RHT and is superior to EUS for this purpose.

Adolescent↗

[CT-Guided brachytherapy. A novel percutaneous technique for interstitial ablation of liver metastases].

PURPOSE: To assess safety and efficacy of CT-guided brachytherapy of liver malignancies. PATIENTS AND METHODS: 21 patients with 21 liver malignancies (19 metastases, two primary liver tumors) were treated with interstitial CT-guided brachytherapy applying a (192)Ir source. In all patients, the use of image-guided thermal tumor ablation such as by radiofrequency or laser-induced thermotherapy (LITT) was impeded either by tumor size > or = 5 cm in seven, adjacent portal or hepatic vein in ten, or adjacent bile duct bifurcation in four patients. Dosimetry was performed using three-dimensional CT data sets acquired after CT-guided positioning of the brachytherapy catheters. RESULTS: The mean tumor diameter was 4.6 cm (2.5-11 cm). The mean minimal tumor dose inside the tumor margin amounted to 17 Gy (12-20 Gy). The proportion of the liver parenchyma exposed to > 5 Gy was 18% (5-39%) of total liver parenchyma minus tumor volume. Nausea and vomiting were observed in six patients after brachytherapy (28%). One patient demonstrated obstructive jaundice due to tumor edema after irradiation of a metastasis adjacent to the bile duct bifurcation. We commonly encountered asymptomatic increases of liver enzymes. Local control rates after 6 and 12 months were 87% and 70%, respectively. CONCLUSION: CT-guided brachytherapy is safe and effective. This technique displays broader indications compared to image-guided thermal ablation by radiofrequency or LITT with respect to tumor size or localization.

Aged↗

Factors excercising an influence on recovery of hibernating myocardium after coronary artery bypass grafting.

OBJECTIVE: Coronary artery bypass grafting (CABG) in patients with endstage coronary disease (CAD) significantly improves symptoms and prolongs life expectancy. Left ventricular function is also improved in some patients, but not in others. Factors which influence functional recovery of hibernating myocardium after revascularization are at present under investigation. METHODS: From 3/2000 to 8/2002, we analyzed 41 patients with an ejection fraction (EF) of < or =30%, who underwent CABG, prospectively. All patients received low-dose dobutamine echocardiography (DE), dobutamine myocardial scintigraphy with SPECT, dobutamine magnetic resonance tomography (MRI), contrast-enhanced MRI and, when necessary, positron emission tomography (PET). Hibernating myocardium (area of interest) was identified with these diagnostic tools preoperatively and biopsy samples were taken intraoperatively. RESULTS: All patients received complete coronary revascularization. Early mortality was 2.4%. Three patients died during follow-up. Six months after the operation DE, MRI and SPECT were repeated. EF increased in 23 patients (group I) by at least >or =5%, and in 14 patients (group II) it did not improve. The wall motion score in the area of interest had increased during preoperative DE in group I significantly. The score did not change in group II. In addition the diastolic-systolic wall thickness increase in the area of interest rose >15% during DE in group I preoperatively; the increase was < or =15% in group II. MRI hyperenhancement of the left ventricle was significantly lower in group I compared to group II preoperatively. SPECT showed myocardial viability in the area of interest in all 37 patients. There were no significant differences between group I and II seen in SPECT. When the area of interest was located in the anterior wall the patients more frequently showed ventricular improvement postoperatively than patients with an area of interest located in the inferior, lateral or posterior wall. Light microscopy showed more severe myocardial cell hypertrophy (>19 microm) and less severe destruction of myocardial cell architecture in biopsies of group I compared to group II (myocardial cell hypertrophy < or =17 microm). Electron microscopy showed mitochondrial abnormalities in size and shape, lack of contractile material and large areas containing nonspecified cytoplasm, lipid droplets, and large glycogen-filled regions, but no significant differences between the two groups. Gene expresssion of the pro-apoptotic genes BAK and BAX was lowered compared to expression in 'normal' myocardium. The anti-apoptotic gene BCL-XL was significantly more expressed in the 'area of interest' of group II patients than in group I patients. CONCLUSIONS: We conclude that in patients with endstage CAD myocardial recovery after coronary revascularization can be predicted using DE and MRI preoperatively. Myocardial regions without any potential of functional recovery show less adaptation (less pronounced myocardial cell hypertrophy), a more severe degree of myocardial architecture destruction and a higher degree of anti-apoptotic gene expression. We recommend a myocardial biopsy when DE and MRI are not favorable in a patient with end stage coronary artery disease referred to us with the option of heart transplantation or coronary bypass.

Adult↗

Repetitive transarterial chemoembolization (rTACE) of hepatocellular carcinoma: comparisons between an arterial port system and conventional angiographic technique.

PURPOSE: To compare the cost and radiation exposure of repetitive transarterial chemoembolization (rTACE) using percutaneously implantable port system with rTACE using conventional catheterization technique. MATERIALS AND METHODS: In five patients with unresectable hepatocellular carcinoma, three cycles of TACE were performed using conventional technique and six cycles using port. The cumulative cost of material and contrast agent and dose area product (DAP) were compared with the cost and DAP that would be expected if the rTACE was performed conventionally. RESULTS: The cost of material and contrast agent was 1002.6 Euro after three cycles of TACE using conventional technique and six cycles using port, but would be 1111.8 Euro if the nine cycles were performed using conventional technique alone. The rTACE with three cycles using conventional technique and six cycles using port led to approximately 63% of the cumulative DAP that would be expected in rTACE using conventional technique alone. CONCLUSION: In rTACE, the use of percutaneously implantable port system might enable a reduction of cost and radiation exposure.

Aged↗

Clinical and physical determinants for toxicity of 125-I seed prostate brachytherapy.

BACKGROUND AND PURPOSE: To assess acute as well as long-term toxicity after permanent prostate seed implantation. To find predictive clinical or dosimetric factors for side effects in order to work out strategies for improvement. PATIENTS AND METHODS: A group of 174 patients with localised prostate cancer was treated with permanent seed implantation between 1999 and 2001, either alone (140 patients) or in combination with external radiotherapy (34 patients). For the majority (114/174, i.e. 66%) a CT was performed four weeks after implantation and analysed in the planning system VariSeed. In the postimplant analysis, dosimetric descriptors (doses, volumes) were determined for the prostate and rectum and compared with the intraoperative values. In addition, a questionnaire was sent to all patients to assess and quantify acute and chronic toxicity (urinary, rectal, sexual) and the impact on subjective acceptance and quality of life (return rate of questionnaires 83%). The derived score changes were correlated with clinical and dosimetric factors. RESULTS: In the mono-brachytherapy group 14% (16/140) required a bladder catheter, of them 8% (9/140) with a manifest urinary obstruction. Long-term rectal toxicity (<5%) and impairment of potency (<30%) are moderate and obviously below other treatment options. Urinary toxicity is dominant with an overall long-term dysuria up to 30% (at a mean observation interval of ten months), and a significant trend to decline with follow-up time. Conversely, the erectile function tends to deteriorate with follow-up time. Nevertheless, quality of life is not significantly reduced and acceptance is high. Our analysis suggests that the main factor for urinary toxicity and impaired erectile function is the dose load to larger portions of the prostate (D(50)>240 Gy), which appears to be attributed to unnecessarily high numbers of seeds (for a fixed activity per seed) and needles. The rectal toxicity is correlated with the high dose regions in the rectum (>/=145 Gy). Urinary toxicity is lower for combined-brachytherapy, while rectal toxicity and impairment of potency are slightly higher. CONCLUSIONS: Toxicity spectrum and quality of life after permanent seed implantation for early prostate cancer are acceptable for nearly all patients (98%). To further improve tolerance we should attempt to achieve a better dose homogeneity, i.e. by reducing D(50). Therefore, special attention should be given to D(50) during the real-time planning process. The necessity of more homogeneous dose distributions might imply a reduction of the activity per seed, e.g. from 0.7 mCi down to 0.6 mCi.

Aged↗

123I-IMT SPECT and 1H MR-spectroscopy at 3.0 T in the differential diagnosis of recurrent or residual gliomas: a comparative study.

The aim of this investigation was to compare two current non-invasive modalities, single photon emission tomography (SPECT) using 123-iodine-alpha-methyl tyrosine (123I-IMT) and single-voxel proton magnetic resonance spectroscopy (1H-MRS) at 3.0 T, with regard to their ability to differentiate between residual/ recurrent tumors and treatment-related changes in patients pretreated for glioma. The patient population comprised 25 patients in whom recurrent glioma was suspected based on MR imaging. SPECT imaging started 10 min after iv. injection of 300-370 MBq 123I-IMT and was performed using a triple-head system. The IMT uptake was calculated semiquantitatively using regions-of-interest. 1H-MRS was performed at 3.0 T using the single-volume point-resolved spectroscopy (PRESS) technique. Guided by MR imaging volumes-of-interest for spectroscopy were placed into the suspected lesions. Signal intensities of choline-containing compounds (Cho), creatine and phosphocreatine (Cr), and N-acetylaspartate (NAA) were obtained. When using the cut-off of 1.62 for 123I-IMT uptake, the sensitivity, specificity, and accuracy of the 123I-IMT SPECT were 95, 100 and 96%, respectively. For 1H-MRS, the sensitivity, specificity and accuracy were 89, 83 and 88%, respectively, based both on the metabolic ratios of Cho/Cr and Cho/NAA as tumor criterion with cut-off values of 1.11 and 1.17, respectively. In conclusion, 123I-IMT SPECT yielded more favorable results compared to 1H-MRS at distinguishing recurrent and/or residual glioma from post-therapeutic changes and may be particularly valuable when the evaluation of tumor extent is necessary.

Adult↗

Impact of SPECT and integrated low-dose CT after radioiodine therapy on the management of patients with thyroid carcinoma.

AIM: To determine the value of single photon emission computed tomography (SPECT) with integrated low-dose computed tomography (CT) for the interpretation of inconclusive foci in planar I whole-body scans after radioiodine therapy. METHODS: Twenty-five patients with inconclusive findings in planar scanning after ablative radioiodine therapy (3.7 GBq I) due to differentiated thyroid cancer were included. SPECT/CT of the region in question was performed with the Millennium VG Hawkeye (GE Medical Systems). SPECT with and without CT fusion were evaluated by two blinded independent nuclear medicine physicians in a consensus reading (including visual plausibility control). Each focus was judged according to its topographical assignment and clinical interpretation. With regard to therapeutic relevance, this information was evaluated in a focus based and patient based analysis. All evaluations used a binary ranking system. Focus assignments were compared to clinical and imaging follow-up. RESULTS: Forty-one lesions were observed in 25 patients. According to follow-up, 17/41 (41%) foci were caused by thyroid residue, 13/41 (32%) were caused by metastases, and 11/41 (27%) were not malignant. Of these foci, a SPECT/CT consensus reading assigned 39 (95%) correctly, as fused images of two foci did not pass the visual plausibility control (excluding one patient due to misregistration). For the remaining 39 foci, improved anatomical assignment by SPECT/CT was seen in 17/39 (44%) cases. CONCLUSIONS: The changed interpretation of 15/39 (38%) foci would have been relevant for therapy in the focus based analysis. In the patient based analysis the information was still therapeutically relevant in 6/24 (25%) patients. Furthermore, plausibility control is also crucial in SPECT/CT image fusion in order to rule out artifacts.

Adult↗

Gauging effective spatial resolution in multirow helical cardiac computed tomography with a dynamic phantom.

PURPOSE: To devise a numerical indicator of image quality for multirow helical cardiac computed tomography (CT) and its relation to temporal resolution. MATERIALS AND METHODS: A pulsatile cardiac assist device was used to simulate cardiac wall motion by mechanically transmitting the device dynamics to a piece of tungsten wire. Wire motion induced by different device rates was captured with an 8-row subsecond helical CT scanner operating with various scanning parameters. Image artifacts were visually assessed and compared with the image point spread function (PSF) using the full width at half maximum (FWHM) area as a numerical estimate of spatial accuracy. RESULTS: At rest, the FWHM area was determined as 1.3 mm2. At a device rate of 60 bpm, the FWHM area ranged from 1.51 mm2 to 21.62 mm2, depending on the time of image reconstruction. Mean reproducibility of the FWHM area measurements was determined as 0.05, whereas visual estimates of motion artifact were highly variable between different readers (kappa = 0.19). Visually determined image quality correlated closely with the FWHM area metric (Spearman's rank correlation, P = 0.0001, rho = 0.841). At a device rate of 100 bpm, the minimum FWHM area was 2.00 mm2 using a single-sector algorithm, 1.41 mm2 using a 2-segment algorithm, and 1.37 mm2 using a 4-segment algorithm. CONCLUSIONS: Use of a pulsatile cardiac assist device could serve as an in vitro test bed for cardiac CT imaging methods. Area FWHM of the PSF correlates well with visually determined image quality of a dynamic phantom, but provides better reproducibility than visual analysis.

Algorithms↗

Hepatic arterial port systems for treatment of liver metastases: factors affecting patency and adverse events.

PURPOSE: To assess the outcome of interventional hepatic arterial port placement in a prospective phase II trial. MATERIALS AND METHODS: One-hundred five consecutive patients were included in this study. Primary endpoint was port patency; secondary endpoints were complications, toxicity, response, and progression free and overall survival. Seventy-eight patients presented with liver metastasis only, 6 patients had additional minor extrahepatic disease, and 21 patients had no evidence of disease after liver resection, laser-induced thermotherapy, or computed tomography (CT)-guided interstitial brachytherapy of liver metastasis. Exclusive access route was the femoral artery. Subgroup analysis compared either 4-F catheters (n = 58) to 2.2-F (n = 33) and 2.7-F (n = 20) microcatheters or different strategies in anatomic variants of the celiac branch: neglect (n = 10) or embolization of minor hepatic feeders (n = 11), splenic arterial port (n = 8), double port (n = 7). RESULTS: Technical success was 99%. Assisted port patency after 6 months was 93%. Complications demanding port revisions were significantly lower in patients receiving 4-F versus 2.2-F and 2.7-F systems (P <.001), with disconnection as the major problem with use of microcatheters. Hepatic artery thrombosis occurred in 10 patients (9%), with successful lysis in two patients. With use of 4-F and 2.2-F catheters, there was no difference with respect to catheter occlusion or hepatic thrombosis. No differences were noted in complications or outcome applying four different strategies in celiac branch variants. In a subgroup of patients receiving folinic acid/5-fluorouracil (170 mg/600 mg; 10% dose escalation per cycle) for 5 days every 4 weeks only 15% experienced Grade 3 toxicity. Patients with liver metastasis and salvage therapy demonstrated progression-free survival of 63% after 6 months and a median survival of 16 months. CONCLUSION: Interventional placement of hepatic arterial port systems may overcome frequent hepatic arterial chemotherapy failures as encountered in all published major trials on hepatic arterial infusion.

Adult↗

Liver malignancies: CT-guided interstitial brachytherapy in patients with unfavorable lesions for thermal ablation.

PURPOSE: To evaluate computed tomography (CT)-guided brachytherapy in patients with very large liver malignancies or with liver tumors located adjacent to the liver hilum. MATERIALS AND METHODS: In this prospective nonrandomized phase II trial, we treated 20 patients (19 liver metastases and one cholangiocarcinoma) with CT-guided high-dose-rate (HDR) brachytherapy using a (192) Iridium source. All patients demonstrated no functional liver degradation prior to irradiation. Entry criteria were liver tumors > 5 cm (group A, n = 11, no upper limit) or liver tumors < or = 5 cm adjacent to the liver hilum (group B, n = 9). Dose planning for brachytherapy was performed with three dimensional (3D) CT data acquired after percutaneous applicator positioning. Magnetic resonance (MR) imaging follow-up was performed 6 weeks and every 3 months post intervention. Primary endpoints were complications, local tumor control (absence of tumor growth after treatment followed by shrinkage of the lesion starting at 6 months) and progression-free survival. RESULTS: The mean tumor diameter was 7.7 cm (range, 5.5-10.8 cm) in group A, 3.6 cm (range, 2.2-4.9 cm) in group B. On average, a minimal dose of 17 Gy in the target volume was applied (range, 12-25 Gy). Severe side effects were recorded in two patients (10%). One patient demonstrated an obstructive jaundice caused by tumor edema after irradiation of a metastasis adjacent to the bile duct bifurcation. One patient developed intra-abdominal hemorrhage that was treated by a single blood transfusion and has ceased. We frequently encountered moderate increases of liver enzymes (70% of patients) and bilirubin (50% of patients) without clinical symptoms and thus considered to be insignificant. The median follow-up was 13 months. In group A (tumors > 5 cm), primary local tumor control after 6 and 12 months was 74% and 40%, respectively; in group B, it was 100% and 71%, respectively. All but one local recurrence (in a patient with diffuse tumor progression) were successfully treated during another CT-guided brachytherapy leading to a primary assisted local control of 93% after 12 months. CONCLUSION: CT-guided brachytherapy based on individual dose plans and 3D CT data sets generated encouraging results in large liver malignancies as well as in tumors located adjacent to the liver hilum.

Adult↗

Dynamic high-resolution electron-beam CT scanning for the diagnosis of bronchiolitis obliterans syndrome after lung transplantation.

PURPOSES: To determine the diagnostic capabilities of dynamic high-resolution electron-beam (HREB) CT scanning for diagnosing bronchiolitis obliterans syndrome (BOS) in lung transplant recipients. MATERIALS AND METHODS: At the time of follow-up examinations after lung transplantation, 52 patients were examined by dynamic HREB CT scan. Visual signs of small airway disease were assessed and compared with lung function. For numerical analysis, the mean lung attenuation and its SD were determined and compared with the course of lung function tests. RESULTS: On visual analysis, significant parenchymal attenuation inhomogeneities were present in eight of nine patients with manifest BOS, and in two of four patients who developed BOS during follow-up. Thirteen of 20 patients with persistent normal lung function displayed homogeneous lung attenuation. On numerical analysis, mean lung attenuation was significantly lower in patients who developed BOS during follow-up than in patients with persistent normal lung function (both in expiration and inspiration, p < 0.0001). With an optimal threshold, the sensitivity was 100% (4 of 4 patients) and the specificity was 90% (19 of 20 patients). In patients with BOS at the time of the CT scan examination, parenchymal attenuation was less homogeneous than in patients with persistent normal lung function (p < 0.0001). With an optimal threshold, the sensitivity was 78% (7 of 9 patients) and the specificity was 85% (17 of 20 patients). CONCLUSIONS: Dynamic HREB CT of lung transplant recipients correlates well with lung function criteria of BOS at the time of the CT examination and with the subsequent progression to BOS.

Adolescent↗

Retrospective digital image fusion of multidetector CT and 18F-FDG PET: clinical value in pancreatic lesions--a prospective study with 104 patients.

UNLABELLED: Differential diagnosis of pancreatic lesions still remains a problem. Whereas CT provides high spatial resolution, PET detects malignant lesions with high sensitivity. The objective of this study was to evaluate the clinical benefit of PET/CT image fusion in the diagnostic workup of pancreatic cancer. METHODS: One hundred four patients with suspected pancreatic lesion underwent triple-phase multidetector CT and (18)F-FDG PET scanning. Voxel-based retrospective registration and fusion of CT and PET were performed with recently developed software. CT, PET, and fused images were assessed by 2 radiologists with regard to the detection of malignancies, possible infiltration of adjacent tissue or lymph nodes, or distant metastases. RESULTS: Fusion of CT and PET images was technically successful in 96.2%. In 2 cases, paraaortic lymph node infiltration was detected only by image fusion; in a further 8 cases, lymph node metastases were confirmed with improved localization. In 5 patients, additional pancreatic tumors or distant metastases only suspected during PET scanning were confirmed. Image fusion improved the sensitivity of malignancy detection from 76.6% (CT) and 84.4% (PET) to 89.1% (image fusion). Compared with CT alone, image fusion increased the sensitivity of detecting tissue infiltration to 68.2%, but at the cost of decreased specificity. CONCLUSION: The most important supplementary finding supplied by image fusion is a more precise correlation with focal tracer hot spots in PET. Image fusion improved the sensitivity of differentiating between benign and malignant pancreatic lesions with no significant change in specificity. All image modalities failed to stage lymph node involvement.

Adult↗

[Differential diagnosis of intra- and perilienal tumors by use of a RES-specific MRI contrast agent].

PURPOSE: To describe the additional benefit in detection and differential diagnosis of peri- and intrasplenic tumors by use of an superparamagnetic iron oxide contrast agent (SPIO). MATERIALS AND METHODS: We represent 7 patients with known malignant tumors. Aim of the examination was the detection and characterisation of intra- or perisplenic tumors. We performed T2w TSE breath triggered sequences before and 10 min after application of SPIO and T1w Flash 2D GRE sequences before and after SPIO and Gadopentetate dimeglumin application. All images were presented to two radiologists, who were asked to asses the presence and characterisation of tumors by using a five-point confidence scale. RESULTS: In two patient intrasplenic hemangiomas were detected, intrasplenic lymphoma, metastasis was excluded, respectively. In two patients perisplenic tumors were diagnosed as gastrointestinal stroma tumors, confirmed by biopsy. In two patients accessory spleens were identified and lymph node metastasis excluded. In one patient an intrasplenic cyst was diagnosed. SPIO enhanced T2w images and Gadopentetate dimeglumin enhanced T1w sequences were evaluated as superior. CONCLUSION: The examination of the spleen by use of superparamagnetic iron oxides offers additional abilities in depiction and charaterisation of intra- and perisplenic tumors in first experiences. First clinical observations indicate that a combination of SPIO enhanced T2w sequences and Gadopentetate dimeglumin enhanced T1w dynamic sequences might be superior to other sequences in detection and characterisation of splenic tumors.

Adult↗