Search PubMed⌕ Search

Biomedical subjects

Roland Felix

Publications and source records attributed to Roland Felix.

At least 19 recordsLinked to original sources

Clinical results of CsI-detector-based dual-exposure dual energy in chest radiography.

The aim of this study was to compare the sensitivity and specificity of digital chest radiography alone with digital chest radiography combined with dual-energy chest radiography in the detection of small non-calcified pulmonary nodules. Standard and dual-energy radiographs were obtained with a flat-panel digital chest system. Four radiologists reviewed digital posteroanterior chest radiographs in random order either alone or in conjunction with dual-energy soft tissue and bone images. Twenty patients with a total of 59 pulmonary nodules (median 0.5 cm, range 0.3-2.5 cm) confirmed by computed tomography (HU < or =100) were included. A level of confidence for each diagnosis was documented using a rating scale of 1-5. Brunner and Langer's test was performed for statistical analysis. Subgroup analysis was performed for nodules greater than 1 cm, 1-0.5 cm, and <0.5 cm. For posteroanterior chest radiography, sensitivity was 33%, positive predictive value 83%, specificity 81%, and negative predictive value 30%. Review in conjunction with dual-energy images resulted in a sensitivity of 42%, positive predictive value 88%, specificity 85%, and negative predictive value 34%. The increase of nodule detection overall as well as for different size categories was significant (p<0.05). The increase of the confidence level rating was also significant (p<0.001). Dual energy added to standard posteroanterior chest radiography significantly improves the sensitivity, specificity, and confidence in detection of small non-calcified pulmonary nodules.

Humans↗

Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness.

The purpose of this study was to find out if the use of 1.25-mm collimated thin-slice technique helps to detect more small pulmonary lung nodules than the use of 5 mm. A total of 100 patient examinations that allowed a reconstruction of 1.25-mm slice thickness in addition to the standard of 5-mm slices were included in a prospective study. Acquisition technique included four rows of 1-mm slices. Two sets of contiguous images were reconstructed and compared with 1.25- and 5-mm slice thickness, respectively. Two radiologists performed a film-based analysis of the images. The size and the confidence of the seen nodules were reported. We did not perform a histological verification, according to the normal clinical procedure, although it would be optimal regarding research. Statistical analysis was performed by using longitudinal analysis described by Brunner and Langer. In addition, sensitivity, specificity, negative predictive value and positive predictive value were calculated for each reader using the 1.25-mm sections as the gold standard. As an index for concordance the kappa value was used. A value of p<0.05 was regarded as significant. In 37 patients pulmonary nodules were detected. Twenty-four patients showed more than one nodule; among these, 7 patients had disseminated disease and were excluded from the study. Pulmonary nodules larger than 10 mm in size were equally well depicted with both modalities, whereas lesions smaller than 5 mm in size were significantly better depicted with 1.25 mm (p<0.05). Using 1.25 mm as the gold standard, sensitivity for 5-mm reconstruction interval was 88 and 86% for observers A and B, respectively. No false-positive results were reported for 5-mm sections. Interobserver agreement for nodule detection determined for 1.25-mm reconstruction intervals showed a k value of 0.753, indicating a good agreement, and 0.562 for 5-mm reconstruction intervals, indicating a moderate agreement. Brunner and Langer analysis showed significant differences for slice thickness and no significant difference between the observers. Reduced slice thickness demonstrated an improvement of small nodule detection, confidence levels, and interobserver agreement. Application of thin-slice multidetector-row CT may raise the sensitivity for lung nodule detection, although the higher detection rate of smaller nodules has to be evaluated from a clinical perspective and remains problematic about how the detection of small nodules will effect patient outcome.

Adult↗

Clinical use of the hyperthermia treatment planning system HyperPlan to predict effectiveness and toxicity.

PURPOSE: The main aim is to prove the clinical practicability of the hyperthermia treatment planning system HyperPlan on a beta-test level. Data and observations obtained from clinical hyperthermia are compared with the numeric methods FE (finite element) and FDTD (finite difference time domain), respectively. METHODS AND MATERIALS: The planning system HyperPlan is built on top of the modular, object-oriented platform for visualization and model generation AMIRA. This system already contains powerful algorithms for image processing, geometric modeling, and three-dimensional graphics display. A number of hyperthermia-specific modules are provided, enabling the creation of three-dimensional tetrahedral patient models suitable for treatment planning. Two numeric methods, FE and FDTD, are implemented in HyperPlan for solving Maxwell's equations. Both methods base their calculations on segmented (contour based) CT or MR image data. A tetrahedral grid is generated from the segmented tissue boundaries, consisting of approximately 80,000 tetrahedrons per patient. The FE method necessitates, primarily, this tetrahedral grid for the calculation of the E-field. The FDTD method, on the other hand, calculates the E-field on a cubical grid, but also requires a tetrahedral grid for correction at electrical interfaces. In both methods, temperature distributions are calculated on the tetrahedral grid by solving the bioheat transfer equation with the FE method. Segmentation, grid generation, E-field, and temperature calculation can be carried out in clinical practice at an acceptable time expenditure of about 1-2 days. RESULTS: All 30 patients we analyzed with cervical, rectal, and prostate carcinoma exhibit a good correlation between the model calculations and the attained clinical data regarding acute toxicity (hot spots), prediction of easy-to-heat or difficult-to-heat patients, and the dependency on various other individual parameters. We could show sufficient agreement between the calculations and measurements for power density (specific absorption rate) within the range of assessed precision. Tumor temperatures can only be estimated, because of the rather variable perfusion conditions. The results of the FE and FDTD methods are comparable, although slight differences exist resulting from the differences in the underlying models. There are also statistically provable differences among the tumor entities regarding the attained specific absorption rate, temperatures, and volume loads in normal tissue. However, gross fluctuations exist from patient to patient. CONCLUSION: The hyperthermia planning system HyperPlan could be validated for a number of the 30 patients. Further improvements in the implemented models, FE and FDTD, are required. Even at its present state of development, hyperthermia planning for regional hyperthermia delivers valuable information, not only for clinical practice, but also for further technologic improvements.

Algorithms↗

Laser-induced thermotherapy (LITT) of liver metastases: MR-guided percutaneous insertion of an MRI-compatible irrigated microcatheter system using a closed high-field unit.

PURPOSE: To evaluate the efficacy and safety of a new MRI-compatible irrigated laser microcatheter system for thermal ablation of liver metastases. MATERIAL AND METHODS: The new microcatheter system consists of a titanium needle with a diameter of 1.5 mm and a surrounding Teflon catheter with an outer diameter of 1.8 mm (5.5 F). In vitro laser-induced coagulation of bovine liver tissue was performed to determine the optimal perfusion rate of cooling saline flow, maximum laser energy, and ablation time. Laser-induced thermotherapy using the new microcatheter system, an Nd:YAG laser (Dornier), and a flexible laser light guide (Somatex GmbH, Berlin, Germany) was performed in 28 patients with liver metastases. Percutaneous insertion and positioning of multiple microcatheters in the lesion and monitoring of therapy was performed with a closed high-field MRI scanner using T1-weighted gradient-echo sequences during breath-hold. RESULTS: A perfusion rate of 0.75 mL/minute, a laser energy of 15 W, and an ablation time of 20 minutes were found suitable to achieve safe and sufficient ablation of metastatic tissue. The mean volume of induced coagulation in vitro was 23.9 mL. Ablation of liver metastases in patients was technically and clinically successful. CONCLUSION: The new microcatheter system allows for both catheter placement and monitoring of therapy using a single imaging modality. This shortens the procedure and enables more precise puncture and therapy of liver metastases. Due to the miniaturized design of the catheter and the real-time monitoring, the procedure is minimally invasive and very well tolerated by patients. This new technique seems to be a safe and feasible alternative in treating liver metastases.

Aged↗

[Pre- and post-interventional follow-up of stent graphs with single and multi-slice spiral computerized tomography].

PURPOSE: Could contrast enhanced computed tomography replace conventional catheter angiography in the preoperative evaluation of aortic aneurysms before stentgraft implantation? Does multi slice computed tomography have advantages comparing to single slice computed tomography? METHODS: We compared 15 single slice with 13 multi slice computed tomography studies and reconstructions according to there ability to replace conventional catheter angiography in the preoperative evaluation. In the postoperative follow-up 60 single slice computed tomography studies were compared to 60 multi slice studies. RESULTS: By using appropriate reconstructions the spiral computed tomography studies could deliver all information necessary for implantation. In our study no advantage of multi slice computed tomography could be detected. In the postoperative evaluation of stentgrafts our computed tomography scan protocol could detect all relevant complications in single and multi slice computed tomography. No significant advantage of multi slice computed tomography could be detected. CONCLUSION: Contrast enhanced computed tomography is equal to conventional catheter angiography in the pre- and postoperative evaluation of stengrafts. No significant advantage of multi slice versus single slice could be detected.

Aortic Aneurysm, Abdominal↗

CSF flow imaging in the management of third ventriculostomy with a reversed fast imaging with steady-state precession sequence.

The aim of this study was evaluation of a fast and slow-flow sensitive 2D steady-state free-precession sequence for its capability to prove the patency of endoscopic third ventriculostomy (TVS) in obstructive hydrocephalus, and to exclude communicating third ventricle prior to TVS. We compared gated and ungated variants of this sequence for this purpose. Twenty-three patients with obstructive hydrocephalus underwent 36 MR examinations with a 2D reversed fast imaging with steady-state precession (PSIF) sequence in a retrospectively cardiac gated (cine) and a faster but ungated version beside T1- and T2-weighted sequences in three planes. Thirteen patients were examined both before and after TVS, 4 patients solely before, and 6 patients solely after TVS. Imaging diagnoses were compared with intraoperative findings and clinical findings after TVS. Preoperative diagnosis of non-communicating third ventricle and cisterns was intraoperatively confirmed in 16 of 17 cases. Preoperative MRI was inconclusive in 1 case. Postoperative MRI revealed sufficient TVS in 16 of 19 cases and obstructed TVS in 3 of 19 cases due to several reasons. Findings at MRI were consistent in 19 of 19 cases with the clinical course and intraoperative results. The faster but ungated PSIF sequence was found to be diagnostically equivalent to the cardiac gated cine sequence. The CSF flow imaging with a 2D reversed fast imaging with steady-state precession sequence in conjunction with conventional T1- and T2-weighted images is a fast and reliable tool for pre- and postoperative functional evaluation in third ventriculostomy.

Adult↗

Prospective evaluation of contrast-enhanced MRI in the depiction of peritoneal spread in primary or recurrent ovarian cancer.

The purpose of this study was to assess the accuracy of MRI in the staging of intra-abdominal tumor seeding of ovarian carcinoma. Fifty-seven patients with suspected primary or recurrent ovarian carcinoma were included in this study. All patients received laparotomy within 8 weeks after MRI. The MRI protocol included fat-saturated T1-weighted spin-echo (SE) sequences pre- and post i.v. application of gadopentetate dimeglumine. The criteria for tumor manifestation was contrast enhancement of intra-abdominal soft tissue lesions or peritoneum. The image review was performed by a blinded radiologist, a specialist in gynecological and abdominal MR imaging. Results were compared with findings during laparotomy. Sensitivity, specificity, positive and negative predictive values, and corresponding 95% confidence intervals were calculated for single intra-abdominal locations and for groups of locations defined according to surgical strategies for intra-abdominal cytoreduction. Laparotomy and histopathology confirmed 251 abdominal tumor locations. Sensitivity was high in lower pelvis locations (73-83%) except for ureter or bladder infiltration (40%). Bowel or mesentery locations displayed sensitivity values from 73 to 77%. Sensitivity was very low for pelvic lymph nodes (28%), greater omentum (38%), and lesser sac (43%). Magnetic resonance imaging based on contrast-enhanced fat-saturated T1 SE sequences improves planning of cytoreduction preceding chemotherapy in advanced primary or relapsed ovarian carcinoma.

Abdominal Neoplasms↗

Preoperative evaluation of malignant liver tumors: comparison of unenhanced and SPIO (Resovist)-enhanced MR imaging with biphasic CTAP and intraoperative US.

The purpose of this study was to evaluate the diagnostic efficacy of iron-oxide-enhanced MRI vs CT during arterial portography (CTAP) and intraoperative ultrasound (IOUS) in detection of liver neoplasms. Seventeen patients with malignant focal liver lesions (liver metastases, n=7), hepatocellular carcinomas (HCC, n=9), and cholangiocellular carcinoma (CCC, n=1) underwent presurgical Resovist-enhanced MRI and CTAP. Two independent observers (A and B) assessed the blinded images of unenhanced and iron-oxide-enhanced MRI vs CTAP for the presence, number, and location of the liver lesions. These results were compared lesion by lesion and segment by segment with the results of intraoperative ultrasound ( n=17) serving as the reference standard. Eighty lesions were detected by intraoperative ultrasound in 17 patients. In comparison with IOUS (lesion-by-lesion analysis) the sensitivity was 86.8% for CTAP, 65% for combined unenhanced MR imaging, and 86.8% for combined Resovist-enhanced MRI as well as 86.8% for the combination of unenhanced and Resovist-enhanced MRI. Compared with the sensitivity of combined unenhanced MRI the sensitivity of CTAP as well as the sensitivity of combined Resovist-enhanced MRI was significantly higher (p<0.05). False-positive results were much higher in CTAP as compared with combined unenhanced and SPIO-enhanced MRI. Using the segment-by-segment analysis the specificity of combined unenhanced MRI with 100% (96.7-100%) as well as combined Resovist-enhanced MRI with 100% (96.7-100%) was significantly higher (p<0.05) in comparison with the specificity of CTAP with 91.1% (83.2-96.1%). The accuracy of combined unenhanced MRI was 100% (93.2-100%), combined Resovist-enhanced MRI 100% (93.6-100%) and of CTAP 85.2% (72.9-93.4%). In the detection of focal liver lesions iron-oxide-enhanced MR imaging is superior to unenhanced MRI and similar to CTAP.

Adult↗

Role of power Doppler techniques and ultrasound contrast enhancement in the differential diagnosis of focal breast lesions.

The purpose of this article is to demonstrate the diagnostic impact of ultrasound in differentiating focal breast lesions with special regard on power Doppler and US contrast agents. The sonographic evaluation of breast lesions has become a standard procedure during the past 15 years. Especially the improvement of B-mode resolution and the use of high-frequency probes increased the diagnostic value of US. Assuming that the neoangiogenetic vascular architecture of solid breast lesions can be depicted reliably by color Doppler, many authors tried to differentiate between benignity and malignancy using Doppler criteria such as flow and morphologic aspects. Additionally, adjuvant techniques, such as harmonic imaging and new US contrast agents, are meant to be success-promising tools. Whereas the sensitivity and specificity of color Doppler have varied in different studies, prognostic prediction and treatment monitoring seem to be the future areas of application. To evaluate sufficiently flow signals of very small vessels with low flow velocity, the use of contrast-enhancing agents may be necessary. Nevertheless, an indispensable condition for successful Doppler-based assessment of the entity of breast lesions is the standardization of techniques, evaluation, analysis and weighting of the parameters.

Blood Flow Velocity↗

Giant fibroma in the left ventricle of an infant: imaging findings in magnetic resonance imaging, echocardiography and angiography.

The diagnosis of a rare case of giant intraventricular fibroma in an infant by MRI in comparison with other imaging modalities, such as echocardiography and angiography, is discussed. For preoperative planning only MRI showed the myocardial infiltration. The myocardial blood supply of the tumor could be evaluated qualitatively by contrast-enhanced MRI, but the direct visualization of the distally located branches could only be assessed by coronary angiography. Magnetic resonance coronary angiography using the navigator technique failed to depict the distal part of the coronaries. The obstruction of the left ventricle outflow tract could be assessed and quantified by all imaging modalities.

Coronary Angiography↗

Magnetic resonance imaging of inflammatory bowel disease: evaluation in a rabbit model.

PURPOSE: To correlate intestinal contrast enhancement and wall thickening with the degree of inflammation in an experimental model of inflammatory bowel disease. MATERIALS AND METHODS: Inflammatory bowel disease was elicited in 39 New Zealand White rabbits by rectal instillation of 2,4,6-trinitrobenzene sulphonic acid (TNBA). Magnetic resonance imaging (MRI) was used to determine bowel wall thickness and intestinal contrast enhancement after the administration of 0.1 mmol/kg of gadodiamide intravenously. MR measurements were compared with the complete histopathologic analysis. RESULTS: MR measurements of bowel wall thickness correlated well with histopathologic measurements in vitro (r = 0.85, P < 0.0001) and with histopathologic evidence of chronic inflammatory bowel disease (P < 0.02). Chronic inflammation was characterized by increased intestinal contrast enhancement (137 +/- 25%) when compared to normal bowel (86 +/- 7%, P = 0.04). CONCLUSION: Contrast-enhanced MRI accurately reflects inflammatory bowel disease in the rabbit model.

Animals↗

Restaging of locally advanced carcinoma of the rectum with MR imaging after preoperative radio-chemotherapy plus regional hyperthermia.

BACKGROUND: The restaging accuracy of MR imaging in advanced primary rectal carcinoma after preoperative radiochemotherapy and regional hyperthermia was evaluated and compared with the histopathologically verified degree of tumor remission after a course of radio-chemo-thermotherapy. PATIENTS AND METHODS: 35 patients with primary rectal carcinoma (uT3/uT4) underwent MRI using a surface coil 4-6 weeks after radiochemotherapy (n = 35), regional hyperthermia (n = 23), and before curative surgery. We defined as gold standard for the remission status the comparison of pretherapeutic endosonography with the histopathology of the resected specimen. RESULTS: T category was correctly restaged after preoperative treatment in only 19 (54%) of 35 patients. Nine of 20 responders were overstaged and seven of 15 non-responders were understaged. Concurrently, the N category was correctly restaged in 19 (54%) of 35 patients (twelve responders and seven non-responders). Overstaging occurred in four responders and two non-responders, understaging occurred in four responders and six non-responders. CONCLUSIONS: MRI proved independent of the response status as not suitable to restage locally advanced rectal carcinoma after preoperative radiochemotherapy despite optimized imaging technique and spatial resolution. Basically, imaging the morphology of a tumor cannot clearly differentiate between vital and devitalized tissue after a treatment. Functional imaging such as PET (positron emission tomography) appears more feasible for restaging after radio-chemo-thermotherapy.

Adult↗

Tumour of the diaphragm mimicking liver lesion.

Tumours of the diaphragm bordering the liver may impose diagnostic difficulties. We report the case of a 46-year-old patient diagnosed with a tumour of the liver based on ultrasound and CT. MRI of the liver depicted a tumour growing from the chest wall towards the liver. Surgery revealed the rare entity of a malignant fibrous histiocytoma of the diaphragm.

Abdominal Abscess↗

The cellular and molecular basis of hyperthermia.

In oncology, the term 'hyperthermia' refers to the treatment of malignant diseases by administering heat in various ways. Hyperthermia is usually applied as an adjunct to an already established treatment modality (especially radiotherapy and chemotherapy), where tumor temperatures in the range of 40-43 degrees C are aspired. In several clinical phase-III trials, an improvement of both local control and survival rates have been demonstrated by adding local/regional hyperthermia to radiotherapy in patients with locally advanced or recurrent superficial and pelvic tumors. In addition, interstitial hyperthermia, hyperthermic chemoperfusion, and whole-body hyperthermia (WBH) are under clinical investigation, and some positive comparative trials have already been completed. In parallel to clinical research, several aspects of heat action have been examined in numerous pre-clinical studies since the 1970s. However, an unequivocal identification of the mechanisms leading to favorable clinical results of hyperthermia have not yet been identified for various reasons. This manuscript deals with discussions concerning the direct cytotoxic effect of heat, heat-induced alterations of the tumor microenvironment, synergism of heat in conjunction with radiation and drugs, as well as, the presumed cellular effects of hyperthermia including the expression of heat-shock proteins (HSP), induction and regulation of apoptosis, signal transduction, and modulation of drug resistance by hyperthermia.

Cell Death↗

Flat panel digital radiography compared with storage phosphor computed radiography: assessment of dose versus image quality in phantom studies.

RATIONALE AND OBJECTIVE: To assess and quantify the dose reduction by use of a CsI-flat panel digital radiography (DR)-system compared with digital computed radiography (CR). MATERIALS AND METHODS: A TCDD-test using the CDRAD-phantom was performed at mAs-values of 5, 4, 2.5, 2, 1, and 0.5 mAs for both digital systems. Entrance surface doses were recorded for all images. Images were presented to four independent observers. For quantitative comparison the image quality figure (IQF) was calculated. Statistical analysis was performed using the Pearson correlation and the Wilcoxon test. A ROC analysis was performed using the TRG-phantom. Settings of 4, 2.5, 2 mAs for both systems were used. In addition, 1 and 0.5 mAs were used for the DR system only. Statistical significance was evaluated using Student test. RESULTS: The DR system provided equivalent results compared with CR with respect to high frequency information and superior results with respect to low contrast details. Compared with computed radiography, the flat panel detector demonstrated significantly lower IQFs, ensuring a better image quality with respect to contrast and detail detectability. IQFs for DR and CR were equal at a surface dose reduction of 87% for DR. ROC analysis revealed significantly higher values under the curve for DR up to a surface dose reduction of 70%. CONCLUSIONS: Image quality of DR proved to be far superior to CR in particular for low contrast details. The image quality of CR is similar to that of DR only at high dose levels.

Phantoms, Imaging↗

Prospective evaluation of pancreatic tumors: accuracy of MR imaging with MR cholangiopancreatography and MR angiography.

PURPOSE: To prospectively assess accuracy of magnetic resonance (MR) imaging, MR cholangiopancreatography (MRCP), and MR angiography in patients suspected of having pancreatic tumors. MATERIALS AND METHODS: Sixty-six patients suspected of having pancreatic tumors underwent MR imaging (unenhanced and contrast material-enhanced MR, MRCP, and contrast-enhanced MR angiography). Two blinded readers prospectively analyzed the images by consensus, and results were correlated with surgery, biopsy, or follow-up findings. Results were tabulated in two-by-two tables. RESULTS: MR assessment of pancreatic lesion status (differentiation of benign vs malignant) resulted in 60 correct diagnoses (accuracy, 91%), and six (10%) false diagnoses. Among histologically proved malignant tumors, MR imaging yielded correct diagnoses in 42 of 44 patients (sensitivity, 95%; 95% CI: 85%, 99%), whereas 18 of 22 patients with benign findings were classified correctly. At MR imaging, findings in four patients with chronic pancreatitis were wrongly categorized as malignant tumors (specificity, 82%; 95% CI: 60%, 95%), and in one patient, a distal common bile duct carcinoma was not detected. In no patient with pancreatic adenocarcinoma was this tumor misdiagnosed as benign. In patients with malignant tumors who underwent resection, local-regional tumor growth and vascular infiltration were accurately classified in 89% and 94%, respectively. MR imaging depicted histologically proved synchronous hepatic metastases in 82%. The positive and negative predictive values for cancer nonresectability were 90% and 83%, respectively, and the accuracy, sensitivity, and specificity were 85%, 69%, and 95%, respectively. CONCLUSION: Unenhanced and contrast-enhanced MR imaging with MRCP and MR angiography offers potential as a noninvasive tool for assessment of patients suspected of having pancreatic tumors.

Adult↗

Bronchiolitis obliterans syndrome in lung transplant recipients: use of spirometrically gated CT.

PURPOSE: To assess the potential use of spirometrically gated lung computed tomographic (CT) findings in the diagnosis of bronchiolitis obliterans syndrome after lung transplantation. MATERIALS AND METHODS: Forty-nine lung transplant recipients were examined at least 8 months after surgery with spirometrically gated thin-section CT of the lung. In addition to visual signs of small-airway disease at CT, mean lung attenuation and the SD were numerically determined and compared with the results of lung function testing at the time of the CT examination and 1 year later by using factorial analysis of variance. RESULTS: Mean lung attenuation was significantly lower in patients who developed bronchiolitis obliterans syndrome within 1 year after the CT study (-837 HU +/- 3) than in patients with persistent normal lung function (-812 HU +/- 3, P <.001). With an optimal threshold, sensitivity was 69%, specificity was 71%, and accuracy was 84%. Visual analysis did not significantly contribute to the prognostic power of CT. CONCLUSION: Spirometrically gated CT measurements of lung attenuation can be used to predict the onset of bronchiolitis obliterans syndrome after lung transplantation.

Adult↗

Percutaneous transluminal laser angioplasty versus balloon dilation for treatment of popliteal artery occlusions.

PURPOSE: To compare the immediate results, complication rates, and long-term outcomes of percutaneous transluminal laser angioplasty (PTLA) versus balloon dilation alone in the treatment of popliteal artery occlusions. METHODS: In a prospective nonrandomized study conducted between December 1994 and June 2000, 215 symptomatic patients with unilateral popliteal occlusions were treated with either dilation alone (88 patients: 52 men; mean age 62 years, range 48-83) or PTLA (127 patients: 70 men; mean age 64 years, range 49-86) using a 308-nm excimer laser followed by dilation. The average occlusion length was 10.4 cm (range 3-14). RESULTS: PTLA was successful in recanalizing 105 (82.7%) arteries, while the recanalization rate for dilation alone was only 70.4% (62/88; p=0.045). After a mean follow-up of 36 months (range 6-52), the primary and secondary patency rates were 21.7% and 50.8%, respectively, in patients with PTLA and 16.3% and 35.2% in the angioplasty group (p=0.762). The complication rates associated with both techniques were similar. CONCLUSIONS: Although initial recanalization may be better with PTLA, it does not appear to add any long-term benefit over balloon dilation alone.

Aged↗