Search PubMed⌕ Search

Biomedical subjects

Roland Bammer

Publications and source records attributed to Roland Bammer.

At least 37 records · Page 2Linked to original sources

Foundations of advanced magnetic resonance imaging.

During the past decade, major breakthroughs in magnetic resonance imaging (MRI) quality were made by means of quantum leaps in scanner hardware and pulse sequences. Some advanced MRI techniques have truly revolutionized the detection of disease states and MRI can now-within a few minutes-acquire important quantitative information noninvasively from an individual in any plane or volume at comparatively high resolution. This article provides an overview of the most common advanced MRI methods including diffusion MRI, perfusion MRI, functional MRI, and the strengths and weaknesses of MRI at high magnetic field strengths.

Animals↗

Characterizing non-Gaussian diffusion by using generalized diffusion tensors.

Diffusion tensor imaging (DTI) is known to have a limited capability of resolving multiple fiber orientations within one voxel. This is mainly because the probability density function (PDF) for random spin displacement is non-Gaussian in the confining environment of biological tissues and, thus, the modeling of self-diffusion by a second-order tensor breaks down. The statistical property of a non-Gaussian diffusion process is characterized via the higher-order tensor (HOT) coefficients by reconstructing the PDF of the random spin displacement. Those HOT coefficients can be determined by combining a series of complex diffusion-weighted measurements. The signal equation for an MR diffusion experiment was investigated theoretically by generalizing Fick's law to a higher-order partial differential equation (PDE) obtained via Kramers-Moyal expansion. A relationship has been derived between the HOT coefficients of the PDE and the higher-order cumulants of the random spin displacement. Monte-Carlo simulations of diffusion in a restricted environment with different geometrical shapes were performed, and the strengths and weaknesses of both HOT and established diffusion analysis techniques were investigated. The generalized diffusion tensor formalism is capable of accurately resolving the underlying spin displacement for complex geometrical structures, of which neither conventional DTI nor diffusion-weighted imaging at high angular resolution (HARD) is capable. The HOT method helps illuminate some of the restrictions that are characteristic of these other methods. Furthermore, a direct relationship between HOT and q-space is also established.

Anisotropy↗

Self-navigated interleaved spiral (SNAILS): application to high-resolution diffusion tensor imaging.

A fat-saturated twice-refocused spin echo sequence was implemented on a GE Signa 1.5-T whole-body system for diffusion-weighted imaging. Data were acquired using an analytically designed interleaved variable-density (VD) spiral readout trajectory. This flexible design algorithm allowed real-time prescription on the scanner. Each interleaf of the VD spiral oversampled the center of k-space. The oversampling provided an inherent motion compensation capability. The resultant diffusion-weighted images showed good quality without any retrospective motion correction. An iterated motion correction algorithm was developed to further reduce the signal cancellation artifact caused by motion-induced phase error. In this algorithm, a low-resolution phase map was estimated using the oversampled data in the center of k-space in order to correct for phase error in image space. In vivo diffusion tensor imaging (DTI) studies were performed on the brains of healthy volunteers. High-quality isotropic diffusion-weighted images, trace maps, and FA maps from axial, sagittal, and coronal slices were obtained using a VD spiral readout trajectory with matrix size 256 x 256. To our knowledge, this was also the first time in vivo 512 x 512 DTI results were reported.

Algorithms↗

Fast patient workup in acute stroke using parallel imaging.

Treatment of ischemic stroke is a very frustrating topic for neurologists. Presently, the most promising therapy seems to be thrombolysis of the clot. However, this intervention is associated with complication risks, most significantly the risk of post-treatment hemorrhage. This risk of bleeding increases not only with the size of the ischemic brain tissue but also with the time-to-treatment interval. Studies suggest a time window of 3 hours for most effective treatment. Hence, there is demand for a rapid imaging workup, which thus far has been accomplished with computed tomography. Because of the risks associated with thrombolytic therapy, more detailed information is desirable. The distinction between patients with viable ischemically challenged neural tissue and those with complete infarcts is of great importance, and computed tomography is insufficient for this task. This is also true for outlining the etiology of stroke, which may impact treatment. For these tasks, magnetic resonance imaging has been proposed. However, comprehensive imaging protocols take time, which is limited in stroke treatment. Therefore, new imaging techniques are required that provide both in-depth information and short scanning times. Parallel imaging is uniquely suited for this purpose.

Acute Disease↗

Parallel imaging of the abdomen.

Parallel imaging holds great potential for improving the quality of diagnostic abdominal MRI. The increased imaging speed afforded by parallel imaging can be translated into the obvious benefits of reduced scan time with set resolution and coverage, improved spatial resolution with set imaging time and coverage, increased anatomic coverage for a set imaging time and resolution, or some combination of the above. Additionally, the reduction in scan time can also allow some sequences that normally require multiple breath-holds to be performed with only one, or simply make breath-hold imaging possible for more patients. The decreased echo-train length allows for truer T2-weighting, less magnetic susceptibility artifact, and less blurring with echo-train imaging. Dynamic contrast-enhanced sequences can be acquired with improved temporal or spatial resolution. All of these potential advantages come with the trade-off of decreased signal-to-noise ratio, but for many patients, the benefits far outweigh the drawbacks and can vastly improve the diagnostic quality of abdominal MRI.

Artifacts↗

Current concepts and advances in clinical parallel magnetic resonance imaging.

Parallel imaging (PI) is one of the most promising recent advances in MRI technology and has, similar to the introduction of multidetector helical scanning in CT, revolutionized MR imaging. The speed of all conventional MRI methods has been limited by either gradient strength or their switching times. The basic idea in PI is to use some of the spatial information contained in the individual elements of a radiofrequency (RF) receiver coil array to increase imaging speed. These PI techniques are removing some of the previous limitations in speed of MRI scanners and set the basis for accelerated image formation. Initially, PI was motivated by the wish to accelerate image acquisition without reducing the spatial resolution of the image. However, depending on the application, it turned out that PI harbors several other advantages. Among those is the possibility for higher spatial resolution, shorter breath-holds or multiple averaging to diminish motion artifacts, reduced image blurring and geometric distortions, better temporal resolution, and means for navigator correction. This overview focuses on technical aspects, clinical applications, and ongoing research in different areas of the human body. The critical review demonstrates PI's great versatility as well as the current trends to use this unique technique in the majority of clinical scan protocols.

Humans↗

Influence of arterial input function on hypoperfusion volumes measured with perfusion-weighted imaging.

BACKGROUND AND PURPOSE: The arterial input function (AIF) is critical in determining hemodynamic parameters quantitatively with bolus-tracking MRI. We studied the effect of varying the location of measurement of AIF on the volume of hypoperfusion. We compared the volumes of hypoperfusion obtained with different AIFs with the final ischemic lesion volume. METHODS: We included 13 patients with acute cerebral ischemia in the anterior circulation who underwent diffusion- (DWI) and perfusion (PWI)-weighted imaging within 8 hours after symptom onset and exhibited DWI lesion expansion between baseline and follow-up. AIF was measured at 4 locations: near both middle cerebral arteries (MCAs), in MCA branches adjacent to the largest DWI abnormality, and at the same level on the opposite hemisphere. Hypoperfusion lesion volumes were compared with the DWI volume at follow-up. RESULTS: Large variations in PWI lesion size were found with different AIF locations. The largest PWI lesions were found when AIF was measured at the contralateral MCA. Smaller PWI lesions were found when AIF was measured in the other locations. There was no significant difference between PWI lesion area at baseline and follow-up DWI lesion when AIF was measured at the contralateral MCA. The other PWI lesions significantly underestimated follow-up DWI lesion size. CONCLUSIONS: AIF is an important determinant of the size of hypoperfusion lesions measured with PWI. PWI lesion volumes determined with AIF from the contralateral MCA are associated with follow-up lesion volume.

Acute Disease↗

Single breath-hold diffusion-weighted imaging of the abdomen.

PURPOSE: To generate high quality diffusion-weighted images (DWI) and corresponding isotropic ADC maps of the abdomen with full organ (kidneys) coverage in a single breath-hold. MATERIALS AND METHODS: DWI was performed in 12 healthy subjects with an asymmetric, spin-echo, single-shot EPI readout on a system with high performance gradients (40 mT/minute). The isotropic diffusion coefficient was measured from maps and SNR was determined for both diffusion-weighted and reference images in the liver, spleen, pancreas, and kidneys. In six patients, single-axis diffusion encoding along three orthogonal axes (12 NEX) was employed to assess anisotropic diffusion in kidneys. RESULTS: This technique yielded images of quality and resolution which compares favorably to that of prior work. SNR ranged from 27.0 in liver to 44.1 in kidneys for the diffusion-weighted images, and from 19.6 in liver to 39.0 in kidneys in reference images. ADCs obtained in the renal medulla, renal cortex, liver, spleen, and pancreas were (2091 +/- 55) x 10(-6), (2580 +/- 53) x 10(-6), (1697 +/- 52) x 10(-6), (1047 +/- 82) x 10(-6), and (2605 +/- 168) x 10(-6) mm(2)/second, respectively (mean +/- SE). Apparent diffusion coefficient (ADC) in the renal medulla and cortex were significantly different by paired t-test (P = 4.22 x 10(-10)). Renal medulla and cortex yielded anisotropy indices (AI) of 0.129 and 0.067, respectively. CONCLUSIONS: 1) Single-shot SE EPI DWI in the abdomen with this technique provides high quality images and maps with full organ coverage in a single breath-hold; 2) ADCs obtained in the renal medulla and cortex are significantly different; and 3) diffusion within the renal medulla is moderately anisotropic.

Abdomen↗

Basic principles of diffusion-weighted imaging.

In diffusion-weighted MRI (DWI), image contrast is determined by the random microscopic motion of water protons. During the last years, DWI has become an important modality in the diagnostic work-up of acute ischemia in the CNS. There are also a few promising reports about the application of DWI to other regions in the human body, such as the vertebral column or the abdomen. This manuscript provides an introduction into the basics of DWI and Diffusion Tensor imaging. The potential of various MR sequences in concert with diffusion preparation are discussed with respect to acquisition speed, spatial resolution, and sensitivity to bulk physiologic motion. More advanced diffusion measurement techniques, such as high angular resolution diffusion imaging, are also addressed.

Artifacts↗

In vivo MR tractography using diffusion imaging.

Diffusion in structured tissue, such as white matter or muscle, is anisotropic. MR diffusion tensor imaging (DTI) measures anisotropy per pixel and provides the directional information relevant for MR tractography or fiber tracking in vivo. MR tractography is non-invasive, relatively fast, and can be repeated multiple times without destructing important tissue. Moreover, the combination with other MR images is relatively simple. In this paper, the basic principles of tractography are presented. Different tracking methods with varying degrees of complexity are introduced and their potential strengths and weaknesses are discussed. Clinical applications and different strategies for evaluating the fidelity of tracking results are reviewed.

Anisotropy↗

Diffusion imaging of the human spinal cord and the vertebral column.

During the last decade, diffusion-weighted imaging (DWI) has matured from an experimental tool to a clinically useful modality that has not only significantly impacted the diagnosis of (acute) cerebral stroke but has also shown utility in other abnormalities of the brain. Although DWI should be equally sensitive to changes in the spine, it has been used far less frequently in this region of the body. This is mainly because of the inhomogeneous magnetic environment, the small size of the spinal cord, and increased motion in and around the spine. However, once these limitations are overcome, a whole range of applications can be envisioned. Already now, DWI promises to be able to differentiate between benign and malignant vertebral compression fractures. As in the brain, the immediate reduction of diffusivity following ischemic damage in the spinal cord may provide an early identification of patients with infarction. The study of diffusion anisotropy may open new avenues for the detection and better understanding of damage to the long fiber tracts with important clinical implications for disorders like multiple sclerosis and amyotrophic lateral sclerosis. It may also be possible to address, in a more refined manner, mechanisms of damage such as occur with spondylotic myelopathy. To lay the basis for future research in these areas, we will discuss the most appropriate DWI methods for the spine. Following an overview of the basic principles of DWI and associated pitfalls, the most commonly used imaging methods are addressed. Finally, experimental and clinical applications in the spinal cord and the vertebral column and their clinical relevance thus far are reviewed.

Diffusion Magnetic Resonance Imaging↗

Line scan diffusion imaging of the spine.

BACKGROUND AND PURPOSE: Recent findings suggest that diffusion-weighted imaging might be an important adjunct to the diagnostic workup of disease processes in the spine, but physiological motion and the challenging magnetic environment make it difficult to perform reliable quantitative diffusion measurements. Multi-section line scan diffusion imaging of the spine was implemented and evaluated to provide quantitative diffusion measurements of vertebral bodies and intervertebral disks. METHODS: Line scan diffusion imaging of 12 healthy study participants and three patients with benign vertebral compression fractures was performed to assess the potential of line scan diffusion imaging of the spinal column. In a subgroup of six participants, multiple b-value (5-3005 s/mm(2)) images were obtained to test for multi-exponential signal decay. RESULTS: All images were diagnostic and of high quality. Mean diffusion values were (230 +/- 83) x 10(-6) mm(2)/s in the vertebral bodies, (1645 +/- 213) x 10(-6) mm(2)/s in the nuclei pulposi, (837 +/- 318) x 10(-6) mm(2)/s in the annuli fibrosi and ranged from 1019 x 10(-6) mm(2)/s to 1972 x 10(-6) mm(2)/s in benign compression fractures. The mean relative intra-participant variation of mean diffusivity among different vertebral segments (T10-L5) was 2.97%, whereas the relative difference in mean diffusivity among participants was 7.41% (P <.0001). The estimated measurement precision was <2%. A bi-exponential diffusion attenuation was found only in vertebral bodies. CONCLUSION: Line scan diffusion imaging is a robust and reliable method for imaging the spinal column. It does not suffer as strongly from susceptibility artifacts as does echo-planar imaging and is less susceptible to patient motion than are other multi-shot techniques. The different contributions from the water and fat fractions need to be considered in diffusion-weighted imaging of the vertebral bodies.

Adult↗

Inter-sequence and inter-imaging unit variability of diffusion tensor MR imaging histogram-derived metrics of the brain in healthy volunteers.

BACKGROUND AND PURPOSE: Diffusion tensor MR imaging has the potential to improve our ability to monitor several neurologic conditions. As a preliminary step to the assessment of the role of diffusion tensor MR imaging in the context of longitudinal and multicenter studies, we evaluated the effect of sequence-, imaging unit-, and imaging-reimaging-induced variations on diffusion tensor MR imaging quantities derived from histogram analysis of a large portion of the central brain of healthy volunteers. METHODS: Each of eight healthy volunteers underwent imaging on two MR imaging units using three different pulsed gradient spin-echo single shot echo-planar pulse sequences (each of them having a different diffusion gradient scheme). Four additional healthy participants underwent imaging twice on the same imaging unit to assess imaging-reimaging variability. RESULTS: For mean diffusivity histograms, the differences between inter-sequence and inter-imaging unit coefficients of variation were significant for all the considered quantities with P values ranging from.003 to <.001. Also, the inter-imaging unit coefficient of variation for average fractional anisotropy was significantly higher than the corresponding inter-sequence coefficient of variation (P =.002). In general, inter-sequence mean diffusivity histogram-derived metrics (coefficients of variation ranging from 1.72% to 5.56%) were more reproducible than were fractional anisotropy histogram-derived metrics (coefficients of variation ranging from 5.45% to 7.34%). Imaging-reimaging variability was found to fall in the range of inter-sequence coefficients of variation for all the considered quantities. CONCLUSION: This study shows that inter-sequence, imaging-reimaging, and inter-imaging unit variabilities of diffusion tensor MR imaging-derived measurements are relatively low, suggesting that diffusion tensor MR imaging might provide additional measures of outcome with which to assess the evolution of brain structural damage in large scale studies of various neurologic conditions.

Analysis of Variance↗

Diffusion-weighted imaging of the spinal cord: interleaved echo-planar imaging is superior to fast spin-echo.

PURPOSE: To compare and evaluate two novel diffusion-weighted sequences, based either on fast spin-echo (FSE) or interleaved echo-planar imaging (EPI) methods, as potential tools for investing spinal cord abnormalities. MATERIALS AND METHODS: Following recent improvements, both interleaved EPI (IEPI) and FSE techniques could be alternative approaches for rapid diffusion-weighted imaging (DWI). Therefore, a navigated diffusion-weighted multishot FSE sequence and a fat-suppressed navigated diffusion-weighted IEPI sequence with local shimming capabilities were tested. Both methods were compared in a consecutive series of five healthy volunteers and five patients with suspected intramedullary lesions. The sequences were graded qualitatively as either superior, inferior, or equal in quality, and also quantitatively by measuring the amount of ghosting artifacts in the background. Quantitative measurements of the diffusion coefficients within the spine were included. RESULTS: The overall image quality of IEPI was superior to FSE. Two out of five FSE scans were rated with poor image quality, whereas all IEPI scans were of sufficient quality. The ghosting levels ranged from approximately 3.3% to 6.2% for IEPI and from approximately 7.5% to 18.9% for FSE. Diffusion coefficients measured in healthy volunteers were similar for both IEPI and FSE, but showed higher fluctuations with the FSE technique. CONCLUSION: Despite potential advantages of FSE, the IEPI technique is preferable for DWI applications in the spinal cord.

Diffusion↗

Diffusion tensor imaging using single-shot SENSE-EPI.

SENSitivity Encoding (SENSE) greatly enhances the quality of diffusion-weighted echo-planar imaging (EPI) by reducing blurring and off-resonance artifacts. Such improvement would also be desirable for diffusion tensor imaging (DTI), but measures derived from the diffusion tensor can be extremely sensitive to any kind of image distortion. Whether DTI is feasible in combination with SENSE has not yet been explored, and is the focus of this study. Using a SENSE-reduction factor of 2, DTI scans in eight healthy volunteers were carried out with regular- and high-resolution acquisition matrices. To further improve the stability of the SENSE reconstruction, a new coil-sensitivity estimation technique based on variational calculus and the principles of matrix regularization was applied. With SENSE, maps of the trace of the diffusion tensor and of fractional anisotropy (FA) had improved spatial resolution and less geometric distortion. Overall, the geometric distortions were substantially removed and a significant resolution enhancement was achieved with almost the same scan time as regular EPI. DTI was even possible without the use of quadrature body coil (QBC) reference scans. Geometry-factor-related noise enhancement was only discernible in maps generated with higher-resolution matrices. Error boundaries for residual fluctuations in SENSE reconstructions are discussed. Our results suggest that SENSE can be combined with DTI and may present an important adjunct for future neuroimaging applications of this technique.

Brain↗

Diffusion-tensor imaging of cognitive performance.

MR methods have for some years been used to assess cognitive performance. Recently, studies have shown that diffusion-tensor imaging (DTI), which provides noninvasive maps of microscopic structural information of oriented tissue in vivo, is finding utility in studies of cognition in the normal and abnormal aging population. These studies suggest that water proton nonrandom, anisotropic diffusion measured by DTI is highly sensitive to otherwise subtle disease processes not easily seen with conventional MRI tissue contrast mechanisms and raises new issues of the role of MR in assessing cognitive potential.

Alzheimer Disease↗