Search PubMed⌕ Search

Biomedical subjects

Roger M Enoka

Publications and source records attributed to Roger M Enoka.

At least 19 recordsLinked to original sources

Accessory muscle activity contributes to the variation in time to task failure for different arm postures and loads.

Time to failure and electromyogram activity were measured during two types of sustained submaximal contractions with the elbow flexors that required each subject to exert the same net muscle torque with the forearm in two different postures. Twenty men performed the tasks, either by maintaining a constant force while pushing against a force transducer (force task), or by supporting an equivalent load while maintaining a constant elbow angle (position task). The time to failure for the position task with the elbow flexed at 1.57 rad and the forearm horizontal was less than that for the force task (5.2 +/- 2.6 and 8.8 +/- 3.6 min, P = 0.003), whereas it was similar when the forearm was vertical (7.9 +/- 4.1 and 7.8 +/- 4.5 min, P = 0.995). The activity of the rotator cuff muscles was greater during the position tasks (25.1 +/- 10.1% maximal voluntary contraction) compared with the force tasks (15.2 +/- 5.4% maximal voluntary contraction, P < 0.001) in both forearm postures. However, the rates of increase in electromyogram of the accessory muscles and mean arterial pressure were greater for the position task only when the forearm was horizontal (P < 0.05), whereas it was similar for the elbow flexors. These findings indicate that forearm posture influences the difference in the time to failure for the two fatiguing contractions. When there was a difference between the two tasks, the task with the briefer time to failure involved greater rates of increase in accessory muscle activity and mean arterial pressure.

Acceleration↗

Discharge rate during low-force isometric contractions influences motor unit coherence below 15 Hz but not motor unit synchronization.

The purpose of the study was to determine whether pairs of motor units that discharge action potentials at different rates during isometric contractions exhibit different levels of motor unit synchronization or coherence. Twelve subjects (28.6 +/- 6.1 years) performed isometric contractions at target forces slightly above the recruitment threshold (1.02-20.9%) of an isolated motor unit. Based on audio feedback, subjects maintained a relatively constant discharge rate of the isolated unit for about 80 s. Intramuscular electrodes were used to record the discharge of 47 pairs of motor units at rates that ranged from 8.07 to 13.6 pps. Correlated discharge between pairs of motor units was quantified with the common input strength (CIS) index, k' index, and coherence spectrum. Greater discharge rates across pairs of motor units were predicted (R2 = 0.36, P < 0.001) by higher coherence from 8 to 13 Hz (r = -0.52) and lower coherence from 0 to 4 Hz (r = 0.37). Indexes of motor unit synchronization (CIS and k') were strongly associated with motor unit coherence from 16 to 32 Hz (CIS: R2 = 0.63; k': R2 = 0.4; P = 0.001). The CIS index of motor unit synchronization and the motor unit coherence from 16 to 32 Hz did not vary with discharge rate. In contrast, the k' index of motor unit synchronization declined with discharge rate (r2 = 0.20, P = 0.001). Furthermore, greater discharge rates across pairs of motor units were accompanied by higher motor unit coherence in the 8-13 Hz band and lower motor unit coherence in the 0-4 Hz band. These results demonstrate that differences in discharge rate between pairs of motor units in first dorsal interosseus during low-force, isometric contractions were associated with modulation of the correlation in the discharge times of the two motor units at frequencies less than 15 Hz.

Acoustic Stimulation↗

Sensitivity of the cross-correlation between simulated surface EMGs for two muscles to detect motor unit synchronization.

The purpose of the study was to evaluate the use of cross-correlation analysis between simulated surface electromyograms (EMGs) of two muscles to quantify motor unit synchronization. The volume conductor simulated a cylindrical limb with two muscles and bone, fat, and skin tissues. Models of two motor neuron pools were used to simulate 120 s of surface EMG that were detected over both muscles. Short-term synchrony was established using a phenomenological model that aligned the discharge times of selected motor units within and across muscles to simulate physiological levels of motor unit synchrony. The correlation between pairs of surface EMGs was estimated as the maximum of the normalized cross-correlation function. After imposing four levels of motor unit synchrony across muscles, five parameters were varied concurrently in the two muscles to examine their influence on the correlation between the surface EMGs: 1) excitation level (5, 10, 15, and 50% of maximum); 2) muscle size (350 and 500 motor units); 3) fat thickness (1 and 4 mm); 4) skin conductivity (0.1 and 1 S/m); and 5) mean motor unit conduction velocity (2.5 and 4 m/s). Despite a constant and high level of motor unit synchronization among pairs of motor units across the two muscles, the cross-correlation index ranged from 0.08 to 0.56, with variation in the five parameters. For example, cross-correlation of EMGs from pairs of hand muscles, each having thin layers of subcutaneous fat and mean motor unit conduction velocities of 4 m/s, may be relatively insensitive to the level of synchronization across muscles. In contrast, cross-correlation of EMGs from pairs of leg muscles, with larger fat thickness, may exhibit a different sensitivity. These results indicate that cross correlation of the surface EMGs from two muscles provides a limited measure of the level of synchronization between motor units in the two muscles.

Computer Simulation↗

Training adaptations in the behavior of human motor units.

The purpose of this brief review is to examine the neural adaptations associated with training, by focusing on the behavior of single motor units. The review synthesizes current understanding on motor unit recruitment and rate coding during voluntary contractions, briefly describes the techniques used to record motor unit activity, and then evaluates the adaptations that have been observed in motor unit activity during maximal and submaximal contractions. Relatively few studies have directly compared motor unit behavior before and after training. Although some studies suggest that the voluntary activation of muscle can increase slightly with strength training, it is not known how the discharge of motor units changes to produce this increase in activation. The evidence indicates that the increase is not attributable to changes in motor unit synchronization. It has been demonstrated, however, that training can increase both the rate of torque development and the discharge rate of motor units. Furthermore, both strength training and practice of a force-matching task can evoke adaptations in the discharge characteristics of motor units. Because the variability in discharge rate has a significant influence on the fluctuations in force during submaximal contractions, the changes produced with training can influence motor performance during activities of daily living. Little is known, however, about the relative contributions of the descending drive, afferent feedback, spinal circuitry, and motor neuron properties to the observed adaptations in motor unit activity.

Action Potentials↗

Time to task failure varies with the gain of the feedback signal for women, but not for men.

Varying the gain of the feedback signal during a target-matching task alters the synaptic input onto the motor neuron pool. The purpose was to determine the influence of the gain of the feedback signal on the time to failure for men and women when maintaining arm position while supporting a submaximal inertial load with the elbow flexor muscles. While seated with the upper arm vertical, 15 women and 14 men maintained a constant elbow angle (1.57 rad) and supported a load equal to 15% of maximal voluntary contraction (MVC) force until failure. The task was performed on separate days with either a low gain or a high gain for the joint-angle signal. The percent decline in MVC force after the fatiguing contraction was similar for the low- and high-gain conditions (P = 0.24), and did not differ for men and women (P = 0.11). The discharge of motor units in biceps brachii declined at a greater rate during the high-gain condition for men and women, but only the women experienced a briefer time to failure for the high-gain session (8.7 +/- 2.3 min) compared with the low-gain session (11.9 +/- 4.8; P = 0.003). The men had similar times to failure for the low- (6.0 +/- 2.2 min) and high-gain conditions (5.9 +/- 2.1 min; P = 0.35). Linear and stepwise, multiple-regression analyses revealed that the time to failure for the men was associated with the absolute target force, the standard deviation (SD) for the resultant wrist acceleration, and the brachialis aEMG (P <or= 0.02), whereas the time to failure for the women was associated with the rate of decline in motor unit discharge, the SD for the resultant wrist acceleration, and the changes in mean arterial pressure and heart rate (P <or= 0.001). Despite each subject exerting the same net muscle torque during the two gain conditions and a similar effect of feedback gain on the discharge rate of motor units for all subjects, the time to failure for the fatiguing contractions was limited by different mechanisms for the men and women.

Adolescent↗

Diminished task-related adjustments of common inputs to hand muscle motor neurons in older adults.

The purpose of this study was to quantify correlated motor unit activity during isometric, shortening and lengthening contractions of a hand muscle in older adults. Thirteen old subjects (69.6+/-5.9 years, six women) lifted and lowered a light load with abduction-adduction movements of the index finger over 10 degrees using 6-s shortening and lengthening contractions of the first dorsal interosseus muscle. The task was repeated 10-20 times while activity in 23 pairs of motor units was recorded with intramuscular electrodes. The data were compared with 23 motor-unit pairs in 15 young (25.9+/-4.6 years, five women) subjects obtained using a similar protocol in a previous study. Correlated motor unit activity was quantified using time-domain (synchronization index; Common Input Strength) and frequency-domain (coherence) analyses for the same motor-unit pairs. For all contractions, there was no difference with age for the strength of motor-unit synchronization, although age-related differences were observed for synchronous peak widths (young, 17.6+/-7.4 ms; old, 13.7+/-4.9 ms) and motor-unit coherence at 6-9 Hz (z score for young, 3.0+/-1.8; old, 2.2+/-1.5). Despite increased synchrony during lengthening contractions and narrower peak widths for shortening contractions in young subjects, there was no difference in the strength of motor unit synchronization (CIS approximately 0.8 imp/s), or the width of the synchronous peak (approximately 14 ms) during the three tasks in old subjects. Furthermore, no significant differences in motor-unit coherence were observed between tasks at any frequency for old adults. These data suggest that the strategy used by the central nervous system to control isometric, shortening, and lengthening contractions varies in young adults, but not old adults. The diminished task-related adjustments of common inputs to motor neurons are a likely consequence of the neural adaptations that occur with advancing age.

Adult↗

Amplitude cancellation reduces the size of motor unit potentials averaged from the surface EMG.

The purpose of the study was to evaluate the influence of selected physiological parameters on amplitude cancellation in the simulated surface electromyogram (EMG) and the consequences for spike-triggered averages of motor unit potentials derived from the interference and rectified EMG signals. The surface EMG was simulated from prescribed recruitment and rate coding characteristics of a motor unit population. The potentials of the motor units were detected on the skin over a hand muscle with a bipolar electrode configuration. Averages derived from the EMG signal were generated using the discharge times for each of the 24 motor units with lowest recruitment thresholds from a population of 120 across three conditions: 1) excitation level; 2) motor unit conduction velocity; and 3) motor unit synchronization. The area of the surface-detected potential was compared with potentials averaged from the interference, rectified, and no-cancellation EMGs. The no-cancellation EMG comprised motor unit potentials that were rectified before they were summed, thereby preventing cancellation between the opposite phases of the potentials. The percent decrease in area of potentials extracted from the rectified EMG was linearly related to the amount of amplitude cancellation in the interference EMG signal, with the amount of cancellation influenced by variation in excitation level and motor unit conduction velocity. Motor unit synchronization increased potentials derived from both the rectified and interference EMG signals, although cancellation limited the increase in area for both potentials. These findings document the influence of amplitude cancellation on motor unit potentials averaged from the surface EMG and the consequences for using the procedure to characterize motor unit properties.

Action Potentials↗

Steadiness training with light loads in the knee extensors of elderly adults.

PURPOSE: This study was conducted to determine the effect of steadiness training with light loads in the knee extensors of elderly adults. METHODS: Twenty-one elderly adults (72 +/- 4.6 yr) performed 16 wk of closely supervised knee extensor training that consisted of lifting and lowering 30% of the one-repetition maximum (1-RM) load as steadily as possible (10 reps per set, three sets per session, three sessions per week). Nine subjects served in a control group. Unilateral and bilateral maximal voluntary contraction (MVC) force; 1-RM load; force fluctuations during submaximal isometric, concentric, and eccentric contractions; timed functional performance (gait, chair rise, stair ascent and descent); muscle volume via magnetic resonance imaging (MRI); and the electromyogram (EMG) were measured. RESULTS: The training group exhibited modest average gains in MVC force and 1-RM load; muscle volume and EMG were unaltered. Although isometric steadiness was unchanged on average, training elicited the greatest improvements in the least steady subjects. Force fluctuations during concentric and eccentric contractions were significantly reduced. Of 21 subjects, 14 responded to training with gains in 1-RM load greater than the typical change (6%) in the control group. Before training, these responders exhibited greater force during bilateral compared with unilateral contractions. The small changes in physical functional performance were similar for the training and control groups. The training group could lift the pretraining 1-RM load 4.6 times after training (5.6 times for responders). CONCLUSIONS: Steadiness training with the knee extensors thus produced neural adaptations that increased strength in elderly adults who exhibited bilateral facilitation, improved isometric steadiness in unsteady subjects, improved steadiness during concentric and eccentric contractions, and enhanced the ability to lift heavy loads repeatedly.

Aged↗

Muscle activation and time to task failure differ with load type and contraction intensity for a human hand muscle.

Time to failure for sustained isometric contractions of the elbow flexors is briefer when maintaining a constant elbow angle while supporting an inertial load (position task) compared with exerting an equivalent torque against a rigid restraint (force task). Our primary purpose was to determine whether the effects of load type on time to task failure exist when motor unit recruitment cannot be enhanced during a sustained submaximal contraction of an intrinsic hand muscle. A second purpose was to determine whether a greater reserve remains in the muscle after early failure of the position task. Two groups of 10 strength-matched men performed the force and position tasks at either 20% or 60% of maximal force (MVC) with the first dorsal interosseus, followed by a second force task at the same relative intensity. The rate of increase in surface EMG was greater (P = 0.002) and time to failure was briefer (P = 0.005) for the position task (593 +/- 212 s) compared with the force task (983 +/- 328 s) at 20% MVC, whereas there were no task differences in these variables at 60% MVC (P >or= 0.200). Time to failure for the second force tasks did not differ at either contraction intensity (P>or=0.743). These results demonstrate that previously observed effects of load type generalize to a hand muscle, although only for low-intensity contractions. For the position task at low forces, muscle activity increased more rapidly and no additional reserve remained in the muscle at failure compared with the force task. We propose that the briefer time to failure for the position task during sustained, low-intensity contractions is due to earlier recruitment of the motor unit pool.

Adult↗

Prolonged vibration of the biceps brachii tendon reduces time to failure when maintaining arm position with a submaximal load.

Vibration reduces the amplitudes of the tendon jerk response and the Hoffmann and stretch reflexes in the muscle exposed to the vibration, yet does not alter the time to task failure when the task involves exerting a submaximal force against a rigid restraint. Because the amplitude of the stretch reflex is greater when a limb acts against a compliant load than a rigid restraint, the purpose was to determine the influence of prolonged tendon vibration on the time to failure when maintaining limb position with the elbow flexor muscles. Twenty-five healthy men performed the fatiguing contraction by maintaining elbow angle at 1.57 rad until failure while supporting a load equal to 20% of maximal voluntary contraction (MVC) force. The fatiguing contraction was performed on 3 separate days with different levels of vibration applied to the biceps brachii tendon: no vibration, subthreshold for a tonic vibration reflex (TVR), and suprathreshold for a TVR. MVC force before the fatiguing contraction was similar across the three sessions (mean of 3 sessions: 313 +/- 54 N, P = 0.83). Despite a similar decline in MVC force after the fatiguing contraction across conditions (-18.0 +/- 8.0%, P > 0.05), the time to task failure was 3.7 +/- 1.4 min for the suprathreshold TVR condition, 4.3 +/- 2.1 min for the subthreshold TVR condition, and 5.0 +/- 2.2 min for the no-vibration condition (P < 0 0.001). The average EMG of the elbow flexor muscles was similar (P = 0.22) during the fatiguing contractions. However, the fluctuations in limb acceleration at task onset were greater for the suprathreshold TVR condition (P < 0.01), but were not different between the subthreshold TVR and no-vibration conditions (P > or = 0.22). Furthermore, the difference in the SD of limb acceleration between the no-vibration and vibration conditions was correlated with the difference in time to failure for the no-vibration and subthreshold TVR conditions (P = 0.03; r2 = 0.22), but not for the no-vibration and suprathreshold TVR conditions (P = 0.90; r2 = 0.001). These findings indicate that prolonged vibration reduced the time to failure of a sustained contraction when subjects maintained limb position, suggesting that peripheral inputs to the motor neuron pool play a significant role in sustaining a contraction during tasks that require active control of limb position.

Adaptation, Physiological↗

Influence of motor unit properties on the size of the simulated evoked surface EMG potential.

The purpose of the study was to quantify the influence of selected motor unit properties on the simulated amplitude and area of evoked muscle potentials detected at the skin surface. The study was restricted to a motor unit population simulating a hand muscle whose potentials were recorded on the skin over the muscle. Peak-to-peak amplitude and area of the evoked potential were calculated from the summed motor unit potentials and compared across conditions that simulated variation in different motor unit properties. The simulations involved varying the number of activated motor units, muscle fiber conduction velocities, axonal conduction velocities, neuronal activation times, the shape of the intracellular action potential, and recording configurations commonly used over hand muscles. The results obtained for the default condition simulated in this study indicated that ~7% of the motor unit potentials were responsible for 50% of the size of the evoked potential. Variation in the amplitude and area of the evoked muscle potential was directly related to the number of active motor units only when the stimulus activated motor units randomly, and not when activation was based on a parameter such as motor unit size. Independent adjustments in motor unit properties had variable effects on the size of the evoked muscle potential, including when the stimulus activated only a subpopulation of motor units. These results provide reference information that can be used to assist in the interpretation of experimentally observed changes in the size of evoked muscle potentials.

Action Potentials↗

Prolonged muscle vibration increases stretch reflex amplitude, motor unit discharge rate, and force fluctuations in a hand muscle.

The purpose of this study was to compare the influence of prolonged vibration of a hand muscle on the amplitude of the stretch reflex, motor unit discharge rate, and force fluctuations during steady, submaximal contractions. Thirty-two young adults performed 10 isometric contractions at a constant force (5.0 +/- 2.3% of maximal force) with the first dorsal interosseus muscle. Each contraction was held steady for 10 s, and then stretch reflexes were evoked. Subsequently, 20 subjects had vibration applied to the relaxed muscle for 30 min, and 12 subjects received no vibration. The muscle vibration induced a tonic vibration reflex. The intervention (vibration or no vibration) was followed by 2 sets of 10 constant-force contractions with applied stretches (After and Recovery trials). The mean electromyogram amplitude of the short-latency component of the stretch reflex increased by 33% during the After trials (P < 0.01) and by 38% during the Recovery trials (P < 0.01). The standard deviation of force during the steady contractions increased by 21% during the After trials (P < 0.05) and by 28% during the Recovery trials (P < 0.01). The discharge rate of motor units increased from 10.3 +/- 2.7 pulses/s (pps) before vibration to 12.2 +/- 3.1 pps (P < 0.01) during the After trials and to 11.9 +/- 2.6 pps during the Recovery trials (P < 0.01). There was no change in force fluctuations or stretch reflex magnitude for the subjects in the Control group. The results indicate that prolonged vibration increased the short-latency component of the stretch reflex, the discharge rate of motor units, and the fluctuations in force during contractions by a hand muscle. These adjustments were necessary to achieve the target force due to the vibration-induced decrease in the force capacity of the muscle.

Adolescent↗

Muscle endurance is greater for old men compared with strength-matched young men.

The purpose was to compare the time to task failure for a sustained isometric contraction performed at a submaximal intensity with the elbow flexor muscles by young and old men who were matched for strength. Eight young men (18-31 yr) and eight old men (67-76 yr) sustained an isometric contraction at 20% of maximal voluntary contraction (MVC) torque until the target torque could no longer be achieved for at least 5 s. The maximal torque exerted at the wrist was similar for the young and old men before the fatiguing task (65.9 +/- 8.0 vs. 65.4 +/- 8.7 N x m; P > 0.05), and they experienced similar reductions in MVC torque after the fatiguing contraction (31.4 +/- 10.6%; P < 0.05). The time to task failure was longer for the old men (22.6 +/- 7.4 min) compared with the strength-matched young men (13.0 +/- 5.2 min; P < 0.05), despite each group sustaining a similar torque during the fatiguing contraction (P > 0.05). The increases in torque fluctuations, electromyographic (EMG) bursting activity, and heart rate were greater for young men compared with the old men, and they were less at task failure for the old men (P < 0.05). Mean arterial pressure increased at a similar rate for both groups of men (P > 0.05), whereas the averaged EMG activity and rating of perceived exertion reached similar values at task failure for the young and old men (P > 0.05). These findings indicate that the longer time to task failure for the old men when performing the submaximal contraction was not due the absolute target torque exerted during the contraction.

Adolescent↗

Coherence at 16-32 Hz can be caused by short-term synchrony of motor units.

Time- and frequency-domain measures of discharge times for pairs of motor units are used to infer the proportion of common synaptic input received by motor neurons. The physiological mechanisms that can produce the experimentally observed peaks in the cross-correlation histogram and the coherence spectrum are uncertain. The present study used a computational model to impose synchronization on the discharge times of motor units. Randomly selected discharge times of a unit that was being synchronized to a reference unit were aligned with some of the discharge times of the reference unit, provided the original discharge time was within 30 ms of the discharge by the reference unit. All time-domain measures (indexes CIS, E, and k') were sensitive to changes in the level of imposed motor-unit synchronization (P < 0.01). In addition, synchronization caused a peak between 16 and 32 Hz in the coherence spectrum. The shape of the cross-correlogram determined the frequency at which the peak occurred in the coherence spectrum. Further, the magnitude of the coherence peak was highly correlated with the time-domain measures of motor-unit synchronization (r2 > 0.80), with the highest correlation occurring for index E (r2 = 0.98). Thus the peak in the 16- to 32-Hz band of the coherence spectrum can be caused by the time that individual discharges are advanced or delayed to produce synchrony. Although the in vivo processes that adjust the timing of motor-unit discharges are not fully understood, these results suggest that they may not depend entirely on an oscillatory drive by the CNS.

Humans↗

Practice reduces motor unit discharge variability in a hand muscle and improves manual dexterity in old adults.

A steadiness-improving intervention was used to determine the contribution of variability in motor unit discharge rate to the fluctuations in index finger acceleration and manual dexterity in older adults. Ten healthy and sedentary old adults (age 72.9 +/- 5.8 yr; 5 men) participated in the study involving abduction of the left index finger. Single motor unit activity was recorded in the first dorsal interosseus muscle before, after 2 wk of light-load training (10% maximal load), and after 4 wk of heavy-load training (70% maximal load). As expected, the light-load training was effective in reducing the fluctuations in index finger acceleration during slow shortening (0.25 +/- 0.12 to 0.13 +/- 0.08 m/s(2)) and lengthening contractions (0.29 +/- 0.10 to 0.14 +/- 0.06 m/s(2)). Along with the decline in the magnitude of the fluctuations, there was a parallel decrease in the coefficient of variation for discharge rate during both contraction types (33.8 +/- 6.8 to 25.0 +/- 5.9%). The heavy-load training did not further improve either the fluctuations in acceleration or discharge rate variability. Furthermore, the manual dexterity of the left hand improved significantly with training (Purdue pegboard test: 11 +/- 3 to 14 +/- 1 pegs). Bivariate correlations indicated that the reduction in fluctuations in motor output during shortening (r(2) = 0.24) and lengthening (r(2) = 0.14) contractions and improvement in manual dexterity (r(2) = 0.26) was directly associated with a decline in motor unit discharge rate variability. There was a strong association between the fluctuations in motor output and manual dexterity (r(2) = 0.56). These results indicate that practice of a simple finger task was accompanied by a reduction in the discharge rate variability of motor units, a decrease in the fluctuations in motor output of a hand muscle, and an improvement in the manual dexterity of older adults.

Action Potentials↗

Net excitation of the motor unit pool varies with load type during fatiguing contractions.

To identify the underlying physiological mechanisms for the difference in the time to failure for two types of fatiguing contractions, 20 subjects performed force and position tasks with the elbow flexor muscles at a comparable net muscle torque for a similar duration. Prior to terminating each task, blood flow was occluded to estimate the relative amount of feedback transmitted by small-diameter afferents to the spinal cord. Mean arterial pressure at the conclusion of the fatiguing contraction increased similarly for the two tasks (force: 119% +/- 14%; position: 114% +/- 15%). However, the final values for the electromyographic activity for the elbow flexor muscles (26% +/- 14% and 21% +/- 11%, respectively; P < 0.05), and the increase in the fluctuations in acceleration and force (225% +/- 152% and 154% +/- 53%, respectively; P < 0.05) in the sagittal plane, were significantly greater during the position task compared with the force task. These results suggest a different balance in the excitatory and inhibitory inputs to the spinal motor neurons for the two tasks, which has implications for the design of work tasks and exercise prescription in rehabilitation.

Acceleration↗

Time to task failure differs with load type when old adults perform a submaximal fatiguing contraction.

Young adults exhibit a longer time to task failure when performing a submaximal isometric contraction by pushing against a force transducer (force task) than when supporting an equivalent inertial load (position task). The purpose of this study was to compare the time to failure for old adults when they performed a force task and a position task with the elbow flexor muscles. Eighteen old adults (72 +/- 4 years) performed the force and position tasks at 20% maximal voluntary contraction (MVC) force until task failure. The time to task failure was briefer for the position task (10.6 +/- 6.1 min) than the force task (22.8 +/- 9.1 min, P < 0.05). The rate of increase in electromyographic (EMG) bursting activity, ratings of perceived exertion, mean arterial pressure, heart rate, and fluctuations in motor output during the fatiguing contraction were greater for the position task. However, the increase in averaged EMG for the elbow flexor muscles was greater at termination of the force task. The difference in time to failure for the two tasks was due to a higher level of central neural activity during the position task and was similar to that observed for young adults. These findings indicate that the type of load supported influences the mechanisms and time to task failure for sustained contractions in old adults, and have implications for the design of tasks for rehabilitation and for tasks that minimize fatigue.

Aged↗