Evaluation of mechanical and thermal properties of commonly used denture base resins.

PURPOSE: The purpose of this investigation was to evaluate and compare the mechanical and thermal properties of 6 commonly used polymethyl methacrylate denture base resins. MATERIALS AND METHODS: Sorption, solubility, color stability, adaptation, flexural stiffness, and hardness were assessed to determine compliance with ADA Specification No. 12. Thermal assessments were performed using differential scanning calorimetry and dynamic mechanical analysis. Results were assessed using statistical and observational analyses. RESULTS: All materials satisfied ADA requirements for sorption, solubility, and color stability. Adaptation testing indicated that microwave-activated systems provided better adaptation to associated casts than conventional heat-activated resins. According to flexural testing results, microwaveable resins were relatively stiff, while rubber-modified resins were more flexible. Differential scanning calorimetry indicated that microwave-activated systems were more completely polymerized than conventional heat-activated materials. CONCLUSION: The microwaveable resins displayed better adaptation, greater stiffness, and greater surface hardness than other denture base resins included in this investigation. Elastomeric toughening agents yielded decreased stiffness, decreased surface hardness, and decreased glass transition temperatures.

Adsorption↗

Casting titanium partial denture frameworks: a radiographic evaluation.

STATEMENT OF PROBLEM: Titanium is the most biocompatible metal available for dental castings. However, there is some concern about the castability of titanium used on a daily basis. PURPOSE: A radiographic evaluation of titanium partial denture frameworks was undertaken to ascertain whether these castings were technically acceptable for clinical use. MATERIAL AND METHODS: Three hundred Grade II titanium removable partial denture frameworks were cast in a Titec 205M casting machine. All materials were used as directed by the manufacturer, and all castings were made by an experienced titanium specialist. Each casting was evaluated by radiograph. Based on the number, location, and size of argon inclusions, the frameworks were rated as follows: technically acceptable for clinical use as cast; technically acceptable after laser welding modifications; or unacceptable as cast, with remake necessary. RESULTS: Of the 300 titanium frameworks cast, 97% were rated technically acceptable for clinical use in terms of castability. SUMMARY: Within the limitations of this radiographic evaluation, it was determined that the castability of titanium was such that technically acceptable castings could be made on a daily basis.

Argon↗