Search PubMed⌕ Search

Biomedical subjects

Robert P Carlyon

Publications and source records attributed to Robert P Carlyon.

At least 19 recordsLinked to original sources

A dual-process integrator-resonator model of the electrically stimulated human auditory nerve.

A phenomenological dual-process model of the electrically stimulated human auditory nerve is presented and compared to threshold and loudness data from cochlear implant users. The auditory nerve is modeled as two parallel processes derived from linearized equations of conductance-based models. The first process is an integrator, which dominates stimulation for short-phase duration biphasic pulses and high-frequency sinusoidal stimuli. It has a relatively short time constant (0.094 ms) arising from the passive properties of the membrane. The second process is a resonator, which induces nonmonotonic functions of threshold vs frequency with minima around 80 Hz. The ion channel responsible for this trend has a relatively large relaxation time constant of about 1 ms. Membrane noise is modeled as a Gaussian noise, and loudness sensation is assumed to relate to the probability of firing of a neuron during a 20-ms rectangular window. Experimental psychophysical results obtained in seven previously published studies can be interpreted with this model. The model also provides a physiologically based account of the nonmonotonic threshold vs frequency functions observed in biphasic and sinusoidal stimulation, the large threshold decrease obtained with biphasic pulses having a relatively long inter-phase gap and the effects of asymmetric pulses.

Auditory Threshold↗

Concurrent sound segregation in electric and acoustic hearing.

We investigated potential cues to sound segregation by cochlear implant (CI) and normal-hearing (NH) listeners. In each presentation interval of experiment 1a, CI listeners heard a mixture of four pulse trains applied concurrently to separate electrodes, preceded by a "probe" applied to a single electrode. In one of these two intervals, which the subject had to identify, the probe electrode was the same as a "target" electrode in the mixture. The pulse train on the target electrode had a higher level than the others in the mixture. Additionally, it could be presented either with a 200-ms onset delay, at a lower rate, or with an asynchrony produced by delaying each pulse by about 5 ms re those on the nontarget electrodes. Neither the rate difference nor the asynchrony aided performance over and above the level difference alone, but the onset delay produced a modest improvement. Experiment 1b showed that two subjects could perform the task using the onset delay alone, with no level difference. Experiment 2 used a method similar to that of experiment 1, but investigated the onset cue using NH listeners. In one condition, the mixture consisted of harmonics 5 to 40 of a 100-Hz fundamental, with the onset of either harmonics 13 to 17 or 26 to 30 delayed re the rest. Performance was modest in this condition, but could be improved markedly by using stimuli containing a spectral gap between the target and nontarget harmonics. The results suggest that (a) CI users are unlikely to use temporal pitch differences between adjacent channels to separate concurrent sounds, and that (b) they can use onset differences between channels, but the usefulness of this cue will be compromised by the spread of excitation along the nerve-fiber array. This deleterious effect of spread-of-excitation can also impair the use of onset cues by NH listeners.

Acoustic Stimulation↗

Binaural unmasking with bilateral cochlear implants.

Nearly 100,000 deaf patients worldwide have had their hearing restored by a cochlear implant (CI) fitted to one ear. However, although many patients understand speech well in quiet, even the most successful experience difficulty in noisy situations. In contrast, normal-hearing (NH) listeners achieve improved speech understanding in noise by processing the differences between the waveforms reaching the two ears. Here we show that a form of binaural processing can be achieved by patients fitted with an implant in each ear, leading to substantial improvements in signal detection in the presence of competing sounds. The stimulus in each ear consisted of a narrowband noise masker, to which a tonal signal was sometimes added; this mixture was half-wave rectified, lowpass-filtered, and then used to modulate a 1000-pps biphasic pulse train. All four CI users tested showed significantly better signal detection when the signal was presented out of phase at the two ears than when it was in phase. This advantage occurred even though subjects only received information about the slowly varying sound envelope to be presented, contrary to previous reports that waveform fine structure dominates binaural processing. If this advantage generalizes to multichannel situations, it would demonstrate that envelope-based CI speech-processing strategies may allow patients to exploit binaural unmasking in order to improve speech understanding in noise. Furthermore, because the tested patients had been deprived of binaural hearing for eight or more years, our results show that some sensitivity to time-varying interaural cues can persist over extended periods of binaural deprivation.

Adult↗

Effects of pulse rate on thresholds and loudness of biphasic and alternating monophasic pulse trains in electrical hearing.

Detection thresholds and most comfortable loudnesses (MCLs) were determined as a function of pulse rate for standard biphasic pulse trains (BP) and for anodic and cathodic monophasic phases alternating at fixed intervals (ALT-m). Three different phase durations were examined. With a 100-micros phase duration, thresholds for the ALT-m stimulus were substantially (up to 12 dB) lower than for the BP stimuli at relatively low rates (200 pps), but were similar to the BP thresholds at high rates (1000 pps). Thresholds for BP pulse trains decreased monotonically with increasing rate, whereas the function for ALT-m waveforms was non-monotonic with a maximum between 400 and 1000 pps. These trends occurred for three different cochlear implant devices, different electrode configurations, and, generally, for different phase durations (10.8, 25, and 100 micros/phase). However, at the shorter phase durations, thresholds remained lower for the ALT-m stimulus, even at 5000 pps, the highest rate studied. Dynamic ranges of the BP pulse trains increased with increasing rate, irrespective of the phase duration under test, but for the ALT-m stimuli this was only true at the shorter phase durations tested. At a 100-mus phase duration, dynamic ranges for the ALT-m waveforms did not differ significantly as a function of rate. The results confirm previous reports that delaying charge recovery, in this case by switching from a BP to an ALT-m wave shape, can substantially reduce thresholds [Van Wieringen, A., Carlyon, R.P., Laneau, J., Wouters, J., 2005. Effects of waveform shape on human sensitivity to electrical stimulation of the inner ear. Hear. Res. 200, 73-86; Carlyon, R.P., van Wieringen, A., Deeks, J.M., Long, C.J., Lyzenga, J, Wouters, J., 2005. Effect of inter-phase gap on the sensitivity of cochlear implant users to electrical stimulation. Hear. Res. 205, 210-224]. However, at high pulse rates, this advantage only occurs at short phase durations. In addition, we show that the complex interaction between the effects of pulse shape, rate, and phase duration on thresholds can be captured by the simple linear model described by Carlyon et al.

Adult↗

Asymmetric pulses in cochlear implants: effects of pulse shape, polarity, and rate.

Existing cochlear implants stimulate the auditory nerve with trains of symmetric biphasic (BP) pulses. Recent data have shown that modifying the pulse shape, while maintaining charge balance, may be beneficial in terms of reducing power consumption, increasing dynamic range, and limiting channel interactions. We measured thresholds and most comfortable levels (MCLs) for various 99-pulses-per-second (pps) stimuli. "Pseudomonophasic (PS)" pulses consist of a brief phase of one polarity followed immediately by a longer and lower-amplitude phase of the opposite polarity. We focused on a novel variant of PS pulses, termed the "delayed pseudomonophasic (DPS)" stimulus, in which the longer phase is presented midway between the short phases of two consecutive pulses. DPS pulse trains produced thresholds that were more than 10 dB lower than those obtained with BP pulses. This reduction was much greater than the 0- to 3-dB drop obtained with PS pulses and was still more than 6 dB when a pulse rate of 892 pps was used. A study of the relative contributions of the two phases of DPS suggested that the short, high-amplitude phase dominated the perceived loudness. This study showed major threshold and MCL reductions using a DPS stimulus compared to the widely used BP stimulus. These reductions, which were predicted by a simple linear filter model, might lead to considerable power savings if implemented in a cochlear implant speech processor.

Adult↗

Effect of noise on the detectability and fundamental frequency discrimination of complex tones.

Percent correct performance for discrimination of the fundamental frequency (0) of a complex tone was measured as a function of the level of a background pink noise (using fixed values of the difference in F0, deltaF0) and compared with percent correct performance for detection of the complex tone in noise, again as a function of noise level. The tone included some low, resolvable components, but not the fundamental component. The results were used to test the hypothesis that the worsening in F0 discrimination with increasing noise level was caused by the reduced detectability of the tone rather than by reduced precision of the internal representation of F0. For small values of deltaF0, the hypothesis was rejected because measured performance fell below that predicted by the hypothesis. However, this was true only for high noise levels, within 2-4.5 dB of the level required for masked threshold. The results indicate that the mechanism for extracting the F0 of a complex tone with resolved harmonics is remarkably robust. They also indicate that adding a background noise to a complex tone containing resolved harmonics is not a good means for equating its pitch salience with that of a complex tone containing only unresolved harmonics.

Acoustic Stimulation↗

Perceptual organization of tone sequences in the auditory cortex of awake macaques.

Acoustic sequences such as speech and music are generally perceived as coherent auditory "streams," which can be individually attended to and followed over time. Although the psychophysical stimulus parameters governing this "auditory streaming" are well established, the brain mechanisms underlying the formation of auditory streams remain largely unknown. In particular, an essential feature of the phenomenon, which corresponds to the fact that the segregation of sounds into streams typically takes several seconds to build up, remains unexplained. Here, we show that this and other major features of auditory-stream formation measured in humans using alternating-tone sequences can be quantitatively accounted for based on single-unit responses recorded in the primary auditory cortex (A1) of awake rhesus monkeys listening to the same sound sequences.

Acoustic Stimulation↗

Effects of waveform shape on human sensitivity to electrical stimulation of the inner ear.

Psychophysical measures of the electrically stimulated human auditory system were obtained for different types of symmetric and asymmetric charge-balanced waveforms. Absolute detection thresholds of biphasic, pseudomonophasic, and 'alternating monophasic' current waveforms delivered by a bipolar intra-cochlear electrode pair were determined for four subjects implanted with the LAURA device. Thresholds for alternating monophasic stimuli, in which anodic and cathodic phases alternated every 5 ms, were 5-8 dB lower than for the biphasic waveforms for all four subjects. For two of the four subjects, thresholds for the pseudomonophasic waveforms were also significantly lower than for the biphasic waveforms. These pseudomonophasic thresholds were greatly affected neither by a 500-micros gap inserted between the two phases, nor by whether the shorter phase preceded or followed the longer one. Loudness balancing measures performed at the most comfortable levels also showed that, for equal loudness, alternating monophasic stimuli required a lower level than biphasic and pseudomonophasic waveforms. For three of the four subjects, the dynamic ranges of the pseudomonophasic (but not alternating monophasic) waveforms were greater than those of the biphasic waveforms. The results demonstrate that thresholds and dynamic ranges of human cochlear implant users can be controlled by manipulating the way in which the charge produced by the initial phase of an electrical pulse is recovered.

Adult↗

Effect of inter-phase gap on the sensitivity of cochlear implant users to electrical stimulation.

Human behavioral thresholds for trains of biphasic pulses applied to a single channel of Nucleus CI24 and LAURA cochlear implants were measured as a function of inter-phase gap (IPG). Experiment 1 used bipolar stimulation, a 100-pps pulse rate, and a 400-ms stimulus duration. In one condition, the two phases of each pulse had opposite polarity. Thresholds continued to drop by 9-10 dB as IPG was increased from near zero to the longest value tested (2900 micros for CI24, 4900 micros for LAURA). This time course is much longer than reported for single-cell recordings from animals. In a second condition, the two phases of each pulse had the same polarity, which alternated from pulse to pulse. Thresholds were independent of IPG, and similar to those in condition 1 at IPG=4900 micros. Experiment 2 used monopolar stimulation. One condition was similar to condition 1 of experiment 1, and thresholds also dropped up to the longest IPG studied (2900 micros). This also happened when the pulse rate was reduced to 20 pps, and when only a single pulse was presented on each trial. Keeping IPG constant at 8 micros and adding an extra biphasic pulse x ms into each period produced thresholds that were roughly independent of x, indicating that the effect of IPG in the other conditions was not due to a release from refractoriness at sites central to the auditory nerve. Experiment 3 measured thresholds at three IPGs, which were less than, equal to, and more than one half of the interval between successive pulses. Thresholds were lowest at the intermediate IPG. The results of all experiments could be fit by a linear model consisting of a lowpass filter based on the function relating threshold to the frequency of sinusoidal electrical stimulation. The data and model have implications for reducing the power consumption of cochlear implants.

Action Potentials↗

Optimizing the clinical fit of auditory brain stem implants.

OBJECTIVE: To develop and implement a new audiological fitting procedure for auditory brain stem implants (ABIs), based on an efficient algorithm, and to compare it with two procedures presently used in clinical practice. DESIGN: First, the different procedures were compared by using computer models and simulations with normal-hearing subjects (N = 4). This allows for an analysis of the accuracy of the procedures in a way that is not possible when testing ABI users. The root-mean-square error between the order estimated by the procedure and the true order was calculated. In addition, ABI users (N = 2) were tested with the new procedure to see if it could be successfully applied in clinic. The degree of variability of their results across runs and sessions was analyzed. RESULTS: The tests of the normal-hearing subjects showed that our proposed procedure required significantly fewer trials (22 on average) than procedures presently used in clinic (with 76 and 234 trials on average for the two other procedures tested) to produce the same degree of accuracy. Computer modeling also demonstrated this advantage. Additional testing showed this advantage was maintained under a variety of conditions relevant to the clinic. The two patients tested were able to use this procedure with success, even though they were poor at discriminating the pitch of electrodes. The patients showed results consistent with having about 4 to 5 discriminable groups of electrodes with the 12 to 14 electrodes tested. CONCLUSIONS: The proposed procedure requires fewer trials to produce a clinically useful result and is well tolerated in the clinic. An additional advantage is that it allows testing to be broken down into several "blocks," each containing a small number of trials. If the variability between blocks is small, information can be combined across blocks to increase the accuracy of the result. If the variability is large, perhaps between blocks on different days, this may reflect a significant change in the percepts generated by the implant, and signal to the clinician that a significant alteration in the fitting is required. We recommend its use in ABI user fitting and in cochlear implant fitting when pitch ranking is problematic.

Adult↗

Dominance region for pitch: effects of duration and dichotic presentation.

The dominance region (DR) for pitch was determined for 16- and 200-ms complex tones containing the first seven harmonics of a fundamental frequency (F0) of 250 Hz. A tone was presented with one of the harmonics mistuned upwards or downwards by 3%, followed 500 ms later by a perfectly harmonic tone of the same duration. Listeners adjusted the F0 of the harmonic tone so that its pitch matched that of the mistuned complex. In experiment 1, stimuli were presented monaurally. The DR was significantly higher in harmonic number for the short than for the long duration. The overall sum of the pitch shifts produced by all harmonics was significantly larger for the short than for the long duration, presumably due to stronger perceptual fusion for the former. In experiment 2, the mistuned harmonic was presented only contralaterally to the remainder of the complex. A similar shift in the DR with duration was observed, although the pitch shifts were smaller than for monaural presentation. There was no significant effect of duration on the overall pitch shifts. The results are discussed in terms of pattern recognition and autocorrelation models of pitch perception, and a role of attention in pitch matching is suggested.

Acoustic Stimulation↗

Pitch discrimination interference: the role of pitch pulse asynchrony.

Gockel, Carlyon, and Plack [J. Acoust. Soc. Am. 116, 1092-1104 (2004)] showed that discrimination of the fundamental frequency (F0) of a target tone containing only unresolved harmonics was impaired when an interfering complex tone with fixed F0 was added to the target, but filtered into a lower frequency region. This pitch discrimination interference (PDI) was greater when the interferer contained resolved harmonics than when it contained only unresolved harmonics. Here, it is examined whether this occurred because, when the interferer contained unresolved harmonics, "pitch pulse asynchrony (PPA)" between the target and interferer provided a cue that enhanced performance; this was possible in the earlier experiment because both target and interferer had components added in sine phase. In experiment 1, it was shown that subjects were moderately sensitive to the direction of PPA across frequency regions. In experiments 2 and 3, PPA cues were eliminated by adding the components of the target only, or of both target and interferer, in random phase. For both experiments, an interferer containing resolved harmonics produced more PDI than an interferer containing unresolved harmonics. These results show that PDI is smaller for an interferer with unresolved harmonics even when cues related to PPA are eliminated.

Acoustic Stimulation↗

Can dichotic pitches form two streams?

The phenomenon of auditory streaming reflects the perceptual organization of sounds over time. A series of "A" and "B" tones, presented in a repeating "ABA-ABA" sequence, may be perceived as one "galloping" stream or as two separate streams, depending on the presentation rate and the A-B frequency separation. The present experiment examined whether streaming occurs for sequences of "Huggins pitches," for which the percepts of pitch are derived from the binaural processing of a sharp transition in interaural phase in an otherwise diotic noise. Ten-second "ABA" sequences were presented to eight normal-hearing listeners for two types of stimuli: Huggins-pitch stimuli with interaural phase transitions centered on frequencies between 400 and 800 Hz, or partially-masked diotic tones-in-noise, acting as controls. Listeners indicated, throughout the sequence, the number of streams perceived. The results showed that, for both Huggins-pitch stimuli and tones-in-noise, two streams were often reported. In both cases, the amount of streaming built up over time, and depended on the frequency separation between the A and B tones. These results provide evidence that streaming can occur between stimuli whose pitch percept is derived binaurally. They are inconsistent with models of streaming based solely on differences in the monaural excitation pattern.

Acoustic Stimulation↗

Reduced contribution of a nonsimultaneous mistuned harmonic to residue pitch.

Ciocca and Darwin [V. Ciocca and C. J. Darwin, J. Acoust. Soc. Am. 105, 2421-2430 (1999)] reported that the shift in residue pitch caused by mistuning a single harmonic (the fourth out of the first 12) was the same when the mistuned harmonic was presented after the remainder of the complex as when it was simultaneous, even though subjects were asked to ignore the pure-tone percept. The present study tried to replicate this result, and investigated the role of the presence of the nominally mistuned harmonic in the matching sound. Subjects adjusted a "matching" sound so that its pitch equaled that of a subsequent 90-ms complex tone (12 harmonics of a 155-Hz F0), whose mistuned (+/-3%) third harmonic was presented either simultaneously with or after the remaining harmonics. In experiment 1, the matching sound was a harmonic complex whose third harmonic was either present or absent. In experiments 2A and 2B, the target and matching sound had nonoverlapping spectra. Pitch shifts were reduced both when the mistuned component was nonsimultaneous, and when the third harmonic was absent in the matching sound. The results indicate a shorter than originally estimated time window for obligatory integration of nonsimultaneous components into a virtual pitch.

Acoustic Stimulation↗

How the brain separates sounds.

In everyday life we often listen to one sound, such as someone's voice, in a background of competing sounds. To do this, we must assign simultaneously occurring frequency components to the correct source, and organize sounds appropriately over time. The physical cues that we exploit to do so are well-established; more recent research has focussed on the underlying neural bases, where most progress has been made in the study of a form of sequential organization known as "auditory streaming". Listeners' sensitivity to streaming cues can be captured in the responses of neurons in the primary auditory cortex, and in EEG wave components with a short latency (< 200ms). However, streaming can be strongly affected by attention, suggesting that this early processing either receives input from non-auditory areas, or feeds into processes that do.

Attention↗

Effects of location, frequency region, and time course of selective attention on auditory scene analysis.

Often, the sound arriving at the ears is a mixture from many different sources, but only 1 is of interest. To assist with selection, the auditory system structures the incoming input into streams, each of which ideally corresponds to a single source. Some authors have argued that this process of streaming is automatic and invariant, but recent evidence suggests it is affected by attention. In Experiments 1 and 2, it is shown that the effect of attention is not a general suppression of streaming on an unattended side of the ascending auditory pathway or in unattended frequency regions. Experiments 3 and 4 investigate the effect on streaming of physical gaps in the sequence and of brief switches in attention away from a sequence. The results demonstrate that after even short gaps or brief switches in attention, streaming is reset. The implications are discussed, and a hierarchical decomposition model is proposed.

Attention↗

Simulations of cochlear implant hearing using filtered harmonic complexes: implications for concurrent sound segregation.

Two experiments used simulations of cochlear implant hearing to investigate the use of temporal codes in speech segregation. Sentences were filtered into six bands, and their envelopes used to modulate filtered alternating-phase harmonic complexes with rates of 80 or 140 pps. Experiment 1 showed that identification of single sentences was better for the higher rate. In experiment 2, maskers (time-reversed concatenated sentences) were scaled by -9 dB relative to a target sentence, which was added with an offset of 1.2 s. When the target and masker were each processed on all six channels, and then summed, processing the masker on a different rate to the target improved performance only when the target rate was 140 pps. When the target sentence was processed on the odd-numbered channels and the masker on the even-numbered channels, or vice versa, performance was worse overall, but showed similar effects of pulse rate. The results, combined with recent psychophysical evidence, suggest that differences in pulse rate are unlikely to prove useful for concurrent sound segregation.

Adolescent↗

Across-frequency interference effects in fundamental frequency discrimination: questioning evidence for two pitch mechanisms.

Carlyon and Shackleton [J. Acoust. Soc. Am. 95, 3541-3554 (1994)] presented an influential study supporting the existence of two pitch mechanisms, one for complex tones containing resolved and one for complex tones containing only unresolved components. The current experiments provide an alternative explanation for their finding, namely the existence of across-frequency interference in fundamental frequency (F0) discrimination. Sensitivity (d') was measured for F0 discrimination between two sequentially presented 400 ms complex (target) tones containing only unresolved components. In experiment 1, the target was filtered between 1375 and 15,000 Hz, had a nominal F0 of 88 Hz, and was presented either alone or with an additional complex tone ("interferer"). The interferer was filtered between 125-625 Hz, and its F0 varied between 88 and 114.4 Hz across blocks. Sensitivity was significantly reduced in the presence of the interferer, and this effect decreased as its F0 was moved progressively further from that of the target. Experiment 2 showed that increasing the level of a synchronously gated lowpass noise that spectrally overlapped with the interferer reduced this "pitch discrimination interference (PDI)". In experiment 3A, the target was filtered between 3900 and 5400 Hz and had an F0 of either 88 or 250 Hz. It was presented either alone or with an interferer, filtered between 1375 and 1875 Hz with an F0 corresponding to the nominal target F0. PDI was larger in the presence of the resolved (250 Hz F0) than in the presence of the unresolved (88 Hz F0) interferer, presumably because the pitch of the former was more salient than that of the latter. Experiments 4A and 4B showed that PDI was reduced but not eliminated when the interferer was gated on 200 ms before and off 200 ms after the target, and that some PDI was observed with a continuous interferer. The current findings provide an alternative interpretation of a study supposedly providing strong evidence for the existence of two pitch mechanisms.

Adult↗