Search PubMed⌕ Search

Biomedical subjects

Robert O Crapo

Publications and source records attributed to Robert O Crapo.

11 recordsLinked to original sources

A statistical rationale for the use of forced expired volume in 6 s.

The purpose of the study was to determine the best surrogate for FVC when performing spirometry to detect obstruction or restriction. Volume-time curves from 3,539 participants in the Family Heart Study with acceptable quality test sessions were analyzed. An index of the variability of each timed volume (FEVx) from 1 to 12 s was determined for each subject. The least within-test session variability was seen for forced expired volume in 6 s (FEV(6)) and forced expired volume in 7 s (for both, mean range was 95 mL). The sensitivity and specificity for detecting obstruction and restriction when substituting the FEV(6) for the FVC were then determined before and after allowing for measurement errors of 50 mL (approximately the lower limit of spirometers ability to detect volume). Sensitivity was 76% before the 50-mL error analysis and 95% after. Specificity was 98% before the 50-mL error analysis and 99.5% after. We conclude that use of FEV(6) to replace the FVC for spirometry testing will result in improved reproducibility, with no significant loss of sensitivity or specificity, after allowing a 50-mL measurement error, for detecting obstruction or restriction.

Airway Obstruction↗

Periodontitis and airway obstruction.

BACKGROUND: The objective of this study was to examine the relationship between airway obstruction and periodontal disease. METHODS: Participants were a subset of 860 community- dwelling, well functioning elderly (aged 70 to 79, blacks and whites, males and females) selected from 2,732 participants enrolled in the Health, Aging, and Body Composition Study (Health ABC). The periodontal evaluations occurred over years 2 and 3 of the study and included four indices of periodontal health: plaque index (PI), gingival index (GI), probing depth (PD), and loss of attachment (LOA). The pulmonary evaluation took place in year 1: conducted according to American Thoracic Society criteria, based on the forced expiratory volume/forced vital capacity (FEV1/FVC) ratio and then using the percent of predicted FEV1 to categorize severity. RESULTS: GI (P = 0.023) and LOA (P = 0.009) were significantly better in participants with normal pulmonary function compared to those with airway obstruction after adjusting for age, race, gender, and field center. When stratified by smoking status and after adjusting for age, race, gender, center, and pack-years, there was a significant association between periodontal health and airway obstruction in former smokers. Within this group, those with normal pulmonary function had significantly better GI (P = 0.036) and LOA (P = 0.0003) scores than those with airway obstruction. All periodontal indices were elevated in smokers regardless of pulmonary status; however, the current smoker group was too small to detect a periodontitis effect. CONCLUSION: While the present cross-sectional study cannot provide direct inference of cause and effect, it does reveal a significant association between periodontal disease and airway obstruction, particularly in former smokers.

Aged↗

The Burden of Obstructive Lung Disease Initiative (BOLD): rationale and design.

Quantifying COPD prevalence worldwide is needed to document COPD's effect on disability, health care costs, and impaired quality of life and to inform governments and health planners. As an adjunct to data obtained from population-based studies, and for countries where a fully powered prevalence survey cannot be done, modeling of COPD prevalence and its economic burdens can help estimate potential health care needs and costs. For comparability, standardized methods for prevalence surveys are needed that can be used in countries at all levels of economic development. The Burden of Obstructive Lung Disease (BOLD) Initiative has developed a set of methods for estimating COPD prevalence and a model for assessing its economic impact, and piloted these methods in China and Turkey. The methods were revised to reflect the findings in the pilot studies, and BOLD is now making the standardized methods available worldwide. The BOLD Operations Center provides training, materials, quality control, and data analysis. BOLD emphasizes data quality control at every stage of the process. Data from paper forms completed in the field are entered electronically to a specially designed secure Web platform. Pre- and post-bronchodilator spirometry testing is done on all participants, and all spirometry data are reviewed for quality. Questionnaires are used to obtain information about respiratory symptoms, health status, exposure to risk factors, and economic data about the burden of COPD. BOLD's standardized methods will provide a uniform way to compare COPD burden within and between countries, and where differences are found, to explore explanations for these differences.

Cost of Illness↗

Validity of the American Thoracic Society and other spirometric algorithms using FVC and forced expiratory volume at 6 s for predicting a reduced total lung capacity.

OBJECTIVES: (1) To compare the performance of three spirometric algorithms developed to predict whether the total lung capacity (TLC) is reduced vs normal or increased, (2) to determine if forced expiratory volume at 6 s (FEV(6)) can be substituted for FVC in these algorithms, and (3) to determine if ascertainment bias was present in patients referred for the measurement of spirometry and TLC compared to patients referred for spirometry only. METHODS: We analyzed the results of 219 consenting consecutive patients referred to a New Zealand tertiary hospital respiratory laboratory for spirometry and TLC measurements. Spirometry results from 370 patients referred for spirometry but not lung volumes were used to test for potential ascertainment bias. Spirometry results were analyzed using the lower limit of normal (LLN) values from the third National Health and Nutrition Examination Study reference equations. The equations of Goldman and Becklake, and Crapo were used to classify TLC as normal or abnormal. Receiver operator characteristic curves were used to produce an algorithm using the LLN for FVC and FEV(6). The performances of previous algorithms and our own algorithms were analyzed for predicting a reduced lung volume against the "gold standard," plethysmographic TLC. RESULTS: All three algorithms predicted a reduced TLC with an accuracy of approximately 50%. In contrast, all algorithms predicted TLC was either normal or increased with an accuracy of > or = 99% regardless of the reference set used. The algorithms based on FEV(6) performed equally as well as the FVC algorithms. No ascertainment bias was found. CONCLUSIONS: This study provides evidence that spirometry-based algorithms can accurately predict when TLC is either normal or increased, and can also increase the a priori probability that TLC is reduced to approximately 50%. FEV(6) is equivalent to FVC in these predictions.

Adult↗

A genome-wide scan of pulmonary function measures in the National Heart, Lung, and Blood Institute Family Heart Study.

Spirometric measures of pulmonary function exhibited high heritability in the National Heart, Lung, and Blood Institute Family Heart Study. A genome scan of FEV1, FVC, and the ratio of FEV1/FVC was performed to identify chromosomal regions influencing these measures. The pulmonary traits were adjusted through multiple linear regression techniques for the effects of age, age2, body mass index, height, smoking status, and pack-years of smoking. The distribution of FEV1/FVC was transformed to account for nonnormality, and standardized residuals were used as the quantitative trait for variance component linkage analysis in GENEHUNTER (Whitehead Institute, Cambridge, MA). The genome scan identified regions on chromosomes 4 and 18 with logarithm of the odds favoring linkage (LOD) scores above 2.5, and these two chromosomes were further evaluated by incorporating additional marker genotyping. The FEV1/FVC ratio was linked to chromosome 4 around 28 centimorgans (cM; D4S1511) with a LOD score of 3.5, and the transformed ratio was linked to the same region with a LOD of 2.0. FEV1 and FVC were suggestively linked to regions on chromosome 18 with multipoint LOD scores of 2.4 for FEV1 and 1.5 for FVC at 31 cM (D18S843) and a LOD of 2.9 for FVC at 79 cM (D18S858).

Chromosomes, Human, Pair 18↗

Spirometric reference values for the 6-s FVC maneuver.

STUDY OBJECTIVES: The guidelines of the National Lung Health Education Program for COPD screening proposed a shorter FVC maneuver (forced expiratory volume at 6 s of exhalation [FEV(6)]). Although reference values for FEV(6) are available from the third National Health and Nutrition Examination Survey, forced expiratory flow between 25% and 75% of FVC (FEF(25-75%)) reference values for the shorter 6-s maneuver are not available and are needed. In particular, calculation of largest observed volume during the first 6 s of an FVC maneuver (FVC(6)), from a shortened FVC maneuver, is necessary because the FEF(25-75%) measurement is based on a percentage of FVC or, for a shorter maneuver, FVC(6). DESIGN: We reanalyzed the raw volume-time curves from the third National Health and Nutrition Examination Survey to calculate FVC(6), forced expiratory volume at 0.5 s of exhalation, forced expiratory volume at 3 s of exhalation, ratio of the FEV(1) to largest observed volume during the first 6 s of an FVC maneuver expressed as a percentage (FEV(1)/FEV(6)%), and forced expiratory flow between 25% and 75% of the largest observed volume during the first 6 s of an FVC maneuver (FEF(25-75%6)) in addition to the previously reported values for FEV(1), FEV(6), and FEV(1)/FEV(6)%. PATIENTS OR PARTICIPANTS: Using the same normal, asymptomatic, nonsmoking reference population from a previous study, reference values for these parameters were derived from best values. RESULTS: A total of 2,261 white, 2,564 African-American, and 2,666 Mexican-American subjects aged 8 to 80 years were included in the analysis. Fifty-four subjects from the previous study were not included due to missing raw volume-time curves. CONCLUSIONS: These reference values, utilizing the FVC(6), provide investigators with the means of evaluating the relative merits of using the shorter FVC maneuver as a surrogate for the traditional FVC. They are needed particularly for calculating FEF(25-75%), as statistically significant differences were observed between the FEF(25-75%) and FEF(25-75%6).

Adolescent↗

Standards and interpretive issues in lung function testing.

Pulmonary function tests are most useful when performed with good technique and with an accurate system. Using standard techniques in performing the tests minimizes diagnostic and therapeutic errors. This report discusses the rationale and limits of standardization and offers practical suggestions for using available standards to increase confidence in test results.

Humans↗

Diffusing capacity: how to get it right.

The carbon monoxide diffusing capacity test (D(LCO)) is a commonly performed pulmonary function test that requires technical expertise and attention to detail to get acceptable results. With the advent of automated devices and powerful computer programs, D(LCO) measurement has rapidly gained wide clinical acceptance. But there are many subtle aspects to performing the test that can diminish its accuracy and repeatability. The clinician must ensure: that the D(LCO) instrument is correctly calibrated; that inhalation is least 90% of the largest previously measured vital capacity; that the patient executes a quick, smooth inhalation within 2 seconds; that the breath-hold is 9-11 seconds; that the breath-hold is without straining (no Valsalva or Müller maneuvers); that exhalation is quick and smooth; that a representative gas sample is obtained from the correct portion of the exhalation; and that at least 5 minutes elapse between D(LCO) tests. At least 2 but no more than 5 D(LCO) tests should be conducted, and testing is complete when 2 tests are within 10% or 3 D(LCO) units (mL CO/min/mm Hg) of each other. The reported D(LCO) value is the average of the first 2 tests that meet the reproducibility criteria, but if 5 tests are performed and no 2 meet the reproducibility criteria, the reported value is the average of the 2 tests with the highest inspiratory volumes. These quality controls will help laboratories achieve consistent high D(LCO) accuracy.

Humans↗

Pulmonary function and health-related quality of life in survivors of acute respiratory distress syndrome.

Although survival rates for acute respiratory distress syndrome have increased, there is only limited information regarding the quality of life and the relationship between quality of life and pulmonary function after survival. We prospectively measured pulmonary function, emotional function, and health-related quality of life in a cohort of acute respiratory distress syndrome survivors recruited from patients who were enrolled in a randomized clinical trial of high versus low tidal volume mechanical ventilation at 1 year after their recovery. No significant differences were found between the patients treated with high and low tidal volumes on any pulmonary function measure. Approximately 80% of the patients in both groups demonstrated reduced diffusing capacity; 20% had airflow obstruction, and 20% had chest restriction. Scores on measures of depression and anxiety were within the normal ranges, suggesting that they did not have significant affective symptoms. However, both groups reported decreased health-related quality of life in physical functioning, physical ability to maintain their roles (role-physical), bodily pain, general health, and vitality (energy) on the Medical Outcome Study Short Form Health Survey with similar physical limitations reported on the Sickness Impact Profile questionnaire. The pulmonary function abnormalities correlated with decreased health-related quality of life for domains reflecting physical function. Acute respiratory distress syndrome survivors treated with high and low tidal volumes have abnormal pulmonary function that was related to decreased health-related quality of life 1 year after hospital discharge.

APACHE↗