Search PubMed⌕ Search

Biomedical subjects

Richard Winkelmann

Publications and source records attributed to Richard Winkelmann.

3 recordsLinked to original sources

Dual-contrast single breath-hold 3D abdominal MR imaging.

OBJECT: Multiple contrasts are often helpful for a comprehensive diagnosis. In 3D abdominal MRI, breath-hold techniques are preferred for single contrast acquisitions to avoid respiratory artifacts. In this paper, highly accelerated parallel MRI is used to acquire large 3D abdominal volumes with two different contrasts within a single breath-hold. MATERIAL AND METHODS: In vivo studies have been performed on six healthy volunteers, combining T (1)- and T (2)-weighted, gradient- or spin-echo based scans, as well as water/fat resolved imaging in a single breath-hold. These 3D scans were acquired with an acceleration factor of six, using a prototype 32-element receive array. RESULTS: The presented approach was tested successfully on all volunteers. The whole liver area was covered by a FOV of 350 x 250 x 200 mm(3) for all scans with reasonable spatial resolution. Arbitrary scan protocols generating different contrasts have been shown to be combinable in this single breath-hold approach. Good spatial correspondence with negligible spatial offset was achieved for all different scan combinations acquired in overall breath-hold times between 15 and 25 s. CONCLUSION: Enabled by highly parallel imaging technology, this study demonstrates the technical feasibility and the promising image quality of single breath-hold dual contrast MRI.

Abdomen↗

Free-breathing whole-heart coronary MR angiography on a clinical scanner in four minutes.

PURPOSE: To set up a robust and patient-friendly whole-heart protocol based on 32-receive-channel technology that will potentially allow a large part of the patient population to be addressed. MATERIALS AND METHODS: Ten volunteers were examined on a clinical 1.5 T scanner equipped with a 32-channel data acquisition system using an experimental 32-element coil array. A magnetization-prepared, navigator-gated and -tracked 3D Cartesian balanced FFE sequence was used for whole-heart coronary MR angiography (MRA). With the use of sensitivity encoding (SENSE) and partial Fourier encoding for scan acceleration, nearly isotropic high-resolution data sets were acquired during free breathing in four minutes. RESULTS: A high contrast and sufficient signal-to-noise ratio (SNR) were obtained, which allowed visualization of the major vessels up to the distal regions and detection of major branches. Phase encoding in the anterior-posterior (AP) direction was the most favorable SENSE configuration and allowed a reasonable scan time reduction with moderate SENSE factors. CONCLUSION: The employed 32-receive channel technology enabled a robust trade-off among SNR, spatial resolution, and scan time. In this study the most robust results were obtained using the smallest possible SENSE factors for a given voxel size and scan time.

Adult↗

Ghost artifact removal using a parallel imaging approach.

Parallel imaging techniques, which use several receive coils simultaneously, have been shown to enable a significant scan time reduction by subsampling k-space. Nevertheless, the data acquired with multiple coils in parallel exhibit some redundancy if the number of receive coils exceeds the subsampling factor. This redundancy leads to an overdetermination of the reconstruction problem, which is generally used to optimize the signal-to-noise ratio (SNR). However, it can yield further information about the quality of the reconstructed image, and can thus be used to identify and correct image artifacts. While some known approaches try to solve this problem in k-space, this study addresses it in the spatial domain and uses a modified SENSE reconstruction to reduce or completely remove ghost-type artifacts arising from processes such as motion or flow during data acquisition. Phantom and in vivo studies show significant improvements in image quality after correction, and serve as a basis for the discussion of the performance and limitations of this new approach.

Algorithms↗