Search PubMed⌕ Search

Biomedical subjects

Richard Mackool

Publications and source records attributed to Richard Mackool.

3 recordsLinked to original sources

Intraocular lens power calculation after laser in situ keratomileusis: Aphakic refraction technique.

PURPOSE: To evaluate the accuracy of a new method of intraocular lens (IOL) power calculation for eyes having cataract extraction after previous laser in situ keratomileusis (LASIK). SETTING: Clinical private practice and ambulatory surgical center, Astoria, New York, USA. METHODS: This retrospective study was of 12 eyes of 9 patients who presented for cataract extraction after previous LASIK. Cataract removal was performed under topical anesthesia without IOL implantation. Approximately 30 minutes later, a manifest aphakic refraction was performed. The calculation of the IOL power was obtained by using an algorithm derived from previous experience with secondary IOL implantation (Mackool algorithm). The patient then returned to the operating room for lens implantation (aphakic refraction technique). RESULTS: The refractive error 2 weeks postoperatively, defined as the difference between the intended and actual refractive outcome, ranged from 0.50 diopter (D) of unintended hyperopia to 0.75 (D) of unintended myopia. CONCLUSIONS: The aphakic refraction technique provided an extremely accurate postoperative refraction in eyes having cataract with IOL implantation surgery after previous LASIK. Although the pool sample was small (12 eyes) and the range of the aphakic refraction was limited (+8.50 to 12.375 D), the technique was found to be remarkably accurate.

Algorithms↗

Delayed degradation in a resorbable plating system.

Resorbable plating systems are used extensively for craniofacial reconstruction, particularly in children. The systems provide rigid fixation while potentially minimizing the long-term drawbacks of permanent plating systems such as plate "migration," bone growth restriction, and imaging artifact. However, the need for active plate resorption represents both the strength and weakness of these fixation systems. We present four patients who underwent cranial vault remodeling using a resorbable plating system, following which the plates were palpable and observable for at least 2 years postoperatively. All required surgical removal. On gross inspection, the plates had been replaced by an encapsulated spongy material containing yellow, grainy, cloudy liquid. The bone underlying the plates was depressed and irregular in contour when compared with the adjacent bone. Microscopic studies showed a giant cell foreign-body reaction with crystalline material present in the cell vacuoles.

Absorbable Implants↗