Search PubMed⌕ Search

Biomedical subjects

Richard M Aspden

Publications and source records attributed to Richard M Aspden.

11 recordsLinked to original sources

Stress transfer in collagen fibrils reinforcing connective tissues: effects of collagen fibril slenderness and relative stiffness.

Unlike engineering fibre composite materials which comprise of fibres that are uniform cylindrical in shape, collagen fibrils reinforcing the proteoglycan-rich (PG) gel in the extra-cellular matrices (ECMs) of connective tissues are taper-ended (paraboloidal in shape). In an earlier paper we have discussed how taper of a fibril leads to an axial stress up-take which differs from that of a uniform cylindrical fibre and implications for fibril fracture. The present paper focuses on the influence of fibre aspect ratio, q (slenderness), and Young's modulus (stiffness), relative to that of the gel phase, E(R), on the magnitude of the axial tensile stresses generated within a fibril and wider implications on failure at tissue level. Fibre composite models were evaluated using finite element (FE) and mathematical analyses. When the applied force is low, there is elastic stress transfer between the PG gel and a fibril. FE modelling shows that the stress in a fibril increases with E(R) and q. At higher applied forces, there is plastic stress transfer. Mathematical modelling predicts that the stress in a fibril increases linearly with q. For small q values, fibrils may be regarded as fillers with little ability to provide tensile reinforcement. Large q values lead to high stress in a fibril. Such high stresses are beneficial provided they do not exceed the fracture stress of collagen. Modulus difference regulates the strain energy release density, u, for interfacial rupture; large E(R) not only leads to high stress in a fibril but also insures against interfacial rupture by raising the value of u.

Animals↗

A drop tower for controlled impact testing of biological tissues.

Impact damage, in particular to tissues such as articular cartilage, is a recognised source of morbidity. To understand better the clinical outcomes, it is important to know the mechanics of the damage sustained and the biological response of cells to rapidly applied forces and subsequent tissue disruption. An instrumented drop tower has been designed to enable controlled impact loads to be applied to small samples of biological materials. Impact severity can be controlled by using impactors of different masses and various drop heights. Force and deceleration at impact are recorded at 50,000 samples s(-1) by a force transducer under the sample and an accelerometer on the impactor. Repeatability was tested on rubber washers and coefficients of variation were found to be better than 8% for dynamic stiffness, 3.4% for stress and 4.3% for strain. Initial tests on isolated biopsies of articular cartilage showed that at an initial strain rate of 916 s(-1), the peak dynamic modulus of human femoral head cartilage was 59 MPa, and for a bovine biopsy the initial strain rate and corresponding peak dynamic modulus were 3380 s(-1) and 130 MPa, respectively. The equipment described is capable of applying an impact load to small biopsies of tissue with a defined energy and velocity and measuring deformation and load at high rates of loading.

Aged, 80 and over↗

Competing regulation of matrix biosynthesis by mechanical and IGF-1 signalling in elderly human articular cartilage in vitro.

This study investigates the separate and combined effects of IGF-1 and mechanical loads on chondrocytes in elderly human femoral head articular cartilage. Full depth biopsies of articular cartilage were subjected to either no load, static or cyclic (2 s on/2 s off) loading in unconfined compression at a stress of 1 MPa for 48 h with or without IGF-1 (300 ng ml(-1)). Chondrocyte biosynthetic activity was measured using 35S-sulphate and 3H-leucine during the last 24 h of loading. IGF-1 alone increased the rates of isotope incorporation, by 80% for 35S-SO4 and 40% for 3H-leucine, whereas loading alone reduced matrix biosynthesis. Applying load (cyclic or static) in the presence of IGF-1 returned the incorporation rates to their unstimulated levels. This study suggests elderly human articular cartilage is responsive to stimulation by IGF-1 but mechanical factors seem to act sufficiently strongly in the opposite direction to cancel this response.

Aged↗

Bone shape, structure, and density as determinants of osteoporotic hip fracture: a pilot study investigating the combination of risk factors.

OBJECTIVES: This article compares and combines methods for examining the external shape and the internal structure of the proximal femur with bone mineral density (BMD) to provide a classifier for hip fracture. MATERIALS AND METHODS: Fifty standard pelvic radiographs were available from age-matched fracture and control groups of postmenopausal women. Femoral shape was measured using an active shape model, the trabecular structure by means of a Fourier transform. RESULTS: Both the shape and various structure measures were independent of BMD (P=0.16 and >0.50, respectively). Calculating the area under the receiver operator characteristic (ROC) curve (Az), each of shape (Az=0.81), the best structure measure (Az=0.79-0.93), and BMD (Az=0.79), could partially classify the fracture and control groups. However, the combination achieved almost perfect separation (Az=0.99). CONCLUSIONS: This pilot study shows how bone shape and structure can complement BMD measurements for investigations of fracture risk.

Absorptiometry, Photon↗

Identification of hip fracture patients from radiographs using Fourier analysis of the trabecular structure: a cross-sectional study.

BACKGROUND: This study presents an analysis of trabecular bone structure in standard radiographs using Fourier transforms and principal components analysis (PCA) to identify contributions to hip fracture risk. METHODS: Radiographs were obtained from 26 hip fracture patients and 24 controls. They were digitised and five regions of interest (ROI) were identified from the femoral head and neck for analysis. The power spectrum was obtained from the Fourier transform of each region and three profiles were produced; a circular profile and profiles parallel and perpendicular to the preferred orientation of the trabeculae. PCA was used to generate a score from each profile, which we hypothesised could be used to discriminate between the fracture and control groups. The fractal dimension was also calculated for comparison. The area under the receiver operating characteristic curve (Az) discriminating the hip fracture cases from controls was calculated for each analysis. RESULTS: Texture analysis of standard radiographs using the fast Fourier transform yielded variables that were significantly associated with fracture and not significantly correlated with age, body mass index or femoral neck bone mineral density. The anisotropy of the trabecular structure was important; both the perpendicular and circular profiles were significantly better than the parallel-profile (P < 0.05). No significant differences resulted from using the various ROI within the proximal femur. For the best three groupings of profile (circular, parallel or perpendicular), method (PCA or fractal) and ROI (Az = 0.84 - 0.93), there were no significant correlations with femoral neck bone mineral density, age, or body mass index. PCA analysis was found to perform better than fractal analysis (P = 0.019). CONCLUSIONS: Both PCA and fractal analysis of the FFT data could discriminate successfully between the fracture and control groups, although PCA was significantly stronger than fractal dimension. This method appears to provide a powerful tool for the assessment of bone structure in vivo with advantages over standard fractal methods.

Journal Article↗

High levels of fat and (n-6) fatty acids in cancellous bone in osteoarthritis.

BACKGROUND: Osteoarthritis (OA) is strongly linked with obesity and patients with osteoporosis (OP) have a low body mass index. Anecdotal evidence, clinical and laboratory, suggests that OA bone contains more fat. However, conversion of osteoblasts to adipocytes is reported in OP and this would suggest that the more porous OP cancellous bone would have a high fat content. OBJECTIVES: To test the hypothesis that OA bone contains more fat than OP bone. METHODS: Cores of cancellous bone were obtained from femoral heads of patients undergoing surgery for either OA or OP. Lipids were extracted using chloroform-methanol, weighed and expressed as a fraction of core mass and volume. A fatty acid analysis was performed using gas chromatography. RESULTS: OA bone contained twice as much fat per unit volume of tissue as OP. Levels of n-6 fatty acids were elevated in OA, especially arachidonic acid (C20:4 n-6) which was almost double that found in OP. CONCLUSIONS: These data support the hypothesis that lipids may play a significant role in the pathogenesis of OA and may provide part of the key to understanding why OA and OP lie at opposite ends of the spectrum of bone masses.

Journal Article↗

Statistical methods in finite element analysis.

Finite element analysis (FEA) is a commonly used tool within many areas of engineering and can provide useful information in structural analysis of mechanical systems. However, most analyses within the field of biomechanics usually take no account either of the wide variation in material properties and geometry that may occur in natural tissues or manufacturing imperfections in synthetic materials. This paper discusses two different methods of incorporating uncertainty in FE models. The first, Taguchi's robust parameter design, uses orthogonal matrices to determine how to vary the parameters in a series of FE models, and provides information on the sensitivity of a model to input parameters. The second, probabilistic analysis, enables the distribution of a response variable to be determined from the distributions of the input variables. The methods are demonstrated using a simple example of an FE model of a beam that is assigned material properties and geometry over a range similar to an orthopaedic fixation plate. In addition to showing how each method may be used on its own, we also show how computational effort may be minimised by first identifying the most important input variables before determining the effects of imprecision.

Cervical Vertebrae↗