Search PubMed⌕ Search

Biomedical subjects

Richard G Compton

Publications and source records attributed to Richard G Compton.

At least 19 recordsLinked to original sources

An electrochemical study of PCl3 and POCl3 in the room temperature ionic liquid [C4mpyrr][N(Tf)2].

Voltammetric studies of PCl3 and POCl3 have not been reported in the literature to date, probably due to the instability of these molecules in conventional aprotic solvents giving unstable and irreproducible results. From a previous study [Amigues et al. Chem. Commun. 2005, 1-4], it was found that ionic liquids have the ability to offer a uniquely stable solution phase environment for the study of these phosphorus compounds. Consequently, the electrochemistry of PCl3 and POCl3 has been studied by cyclic voltammetry on a gold microelectrode in the ionic liquid [C4mpyrr][N(Tf)2] (1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide). For both compounds, reduction and oxidation waves were observed and a tentative assignment of the waves is given. For PCl3, the reduction was thought to proceed via the following mechanism: PCl3 + e- <=> PCl3-, PCl3- <=> Cl- + P*Cl2, and Cl- + PCl3 <=> PCl4-. For POCl3, the suggested reduction mechanism was analogous to that of PCl3: POCl3 + e- <=> POCl3-, POCl3- <=> Cl- + P*OCl2, and Cl- + POCl3 <=> POCl4-. In both cases P*Cl2 and P*OCl2 are likely to engage in further reactions. Potential step microdisk chronoamperometry was carried out on the reductive waves of PCl3 and POCl3 to measure diffusion coefficients and number of electrons transferred. It was found that the diffusion of PCl3 was unusually slow (3.1 x 10(-12) m2 s(-1)): approximately 1 order of magnitude less than that for POCl3 (2.2 x 10(-11) m2 s(-1)). For both PCl3 and POCl3, a "split wave" was observed, with an overall electron count of 1. This observation is shown to be consistent with and to "fingerprint" the mechanisms proposed above.

Journal Article↗

Voltammetric sizing of a sphere.

The size of a glass sphere positioned in the center of a microdisk electrode is determined by using a simple electrochemical procedure and is confirmed, additionally, by a microscopical measurement of the sphere at the time of the electrochemical measurement. The cyclic voltammetric response of the naked electrode and of the electrode with the sphere positioned in its center is recorded over a wide range of scan rates (0.002-1.5 V s(-1)). The size of the sphere is then determined by comparison of the experimental voltammogram with simulations for each individual scan rate.

Journal Article↗

Fickian diffusion constrained on spherical surfaces: voltammetry.

A model is developed for the voltammetric response due to surface charge injection at a single point on the surface of a sphere on whose surface the electroactive material is confined. Accordingly, charge diffusion is constrained to the spherical surface and thus mimicks the voltammetric response of immobilised microparticles derivatised with electroactive material. The full cyclic voltammetric response is investigated, and the peak currents, the peak-to-peak separation and the symmetry of the voltammetric wave are shown to be indicative of the heterogeneous kinetics and the geometry of the adsorbed microparticle. The results show strong deviations from the responses expected for planar diffusion.

Journal Article↗

Microwave induced jet boiling investigated via voltammetry at ring-disk microelectrodes.

High intensity microwave radiation is (self-)focused at metal electrodes immersed in aqueous electrolyte solutions to generate highly localized superheating and convection effects. It is shown that, for an electrode pointing downward, low intensity microwave radiation causes density driven convective flow (upward), which at the onset of boiling abruptly switches to a fast jet of liquid moving away from the electrode surface (downward). This "jet-boiling" phenomenon allows extremely high rates of mass transport and mixing to be realized at the electrode surface. Cyclic voltammograms obtained at electrodes placed into a microwave field show very strong mass transport enhancement effects. Cyclic voltammograms recorded at a Pt/Pt ring-disk electrode system (r(1) = 25 microm, r(2) = 32 microm, r(3) = 32.4 microm) in the presence of microwave radiation are employed to further explore mass transport effects under microwave conditions. Mass transport coefficients, collection efficiencies, and temperatures are determined as a function of microwave intensity.

Chemistry, Physical↗

Designer electrode interfaces simultaneously comprising three different metal nanoparticle (Au, Ag, Pd)/carbon microsphere/carbon nanotube composites: progress towards combinatorial electrochemistry.

In this report gold, silver and palladium metal nanoparticles are separately supported on glassy carbon microspheres (GCM) using bulk electroless deposition techniques to produce three different materials labelled as GCM-Au, GCM-Ag and GCM-Pd respectively. These three materials are then combined together into a composite film on a glassy carbon (GC) electrode surface using multiwalled carbon nanotubes (MWCNTs). The MWCNTs serve to not only mechanically support this composite film as a "binder" but they also help to "wire up" each modified GCM to the underlying substrate. The intelligently designed structure of this electrode interface allows this single modified electrode to simultaneously behave as if it were a macrodisc electrode constructed of gold, silver or palladium, whilst using only a fraction of the equivalent amount of these precious metals. Furthermore this unique structure allows the possibility of combinatorial electrochemistry to be realised using a relatively facile electrode construction which avoids the problems of alloy formation, co-deposition and the formation of bimetallic species. For instance a mixture of several different analytes, which can each only be detected on a different specific substrate, can simultaneously be determined using one electrode in a single voltammetric experiment! Alternatively a substrate could undergo electrocatalytic reactions on one substrate, whilst the products, and hence the progress of this reaction, can be studied at a different substrate simultaneously at the same electrode surface. Proof-of-concept examples are presented herein and the designer electrode interface is shown to produce analytical responses to model target analytes such as hydrazine, bromide and thallium(I) ions that are comparable, if not better, than those obtained at metal macrodisc electrodes and even at other state-of-the-art nanoparticle modified electrodes.

Journal Article↗

Electroanalysis using macro-, micro-, and nanochemical architectures on electrode surfaces. Bulk surface modification of glassy carbon microspheres with gold nanoparticles and their electrical wiring using carbon nanotubes.

Gold nanoparticles (approximately 30-60 nm in diameter) were deposited onto the surface of glassy carbon microspheres (10-20 microm) through electroless plating to produce bulk (i.e., gram) quantities of nanoparticle surface-modified microspheres. The gold nanoparticle-modified powder was then characterized by means of scanning electron microscopy and cyclic voltammetry. The voltammetric response of a macroelectrode consisting of a film of gold nanoparticle-modified glassy carbon microspheres, bound together and "wired-up" using multiwalled carbon nanotubes (MWCNTs), was investigated. We demonstrate that by intelligently exploiting both nano- and microchemical architectures and wiring up the electroactive centers using MWCNTs in this way, we can obtain macroelectrode voltammetric behavior while only using approximately 1% by mass of the expensive gold material that would be required to construct the equivalent gold film macrodisk electrode. The potential utility of electrodes constructed using chemical architectures such as this was demonstrated by applying them to the analytical determination of arsenic(III) concentration. An optimized limit of detection of 2.5 ppb was obtained.

Electrochemistry↗

At point of use sono-electrochemical generation of hydrogen peroxide for chemical synthesis: the green oxidation of benzonitrile to benzamide.

At point of use generation of synthetically useful quantities of hydrogen peroxide in a non-optimized sono-electrochemical cell is reported. Proof-of-concept of the use of this procedure for green synthesis is given through the oxidation of benzonitrile to benzamide with yields similar to those obtained via bulk chemical synthesis.

Journal Article↗

Apparent 'electrocatalytic' activity of multiwalled carbon nanotubes in the detection of the anaesthetic halothane: occluded copper nanoparticles.

The electrocatalytic detection of the anaesthetic halothane on a multiwalled carbon nanotube modified glassy carbon electrode is reported with a low limit of detection of 4.6 microM. A thorough investigation of the underlying cause of this apparent catalytic effect is undertaken by comparing the response of various carbon electrodes including glassy carbon, basal- and edge-plane pyrolytic graphite electrodes (bppg and eppg respectively) to increasing additions of halothane. The reduction of halothane is shifted by 250-300 mV to more negative potentials at an eppg electrode than that observed at the GC-CNT electrode. Therefore the results of this investigation show that, surprisingly, the electrocatalysis is not solely due to the introduction of edge-plane-like defect sites on the carbon nanotubes as is commonly found for many other substrates showing favourable voltammetry at nanotube modified electrodes. Instead, we reveal that in this unusual case the electroactive sites for the reduction of halothane are due to the presence of copper nanoparticles occluded within the carbon nanotubes during their production, which are never completely removed by standard purification techniques such as acid washing. This is only the third known case where apparent electrocatalysis by carbon nanotube modified electrodes is due to occluded metal-related nanoparticles within the nanotube structure, rather than the active sites being the edge-plane-like defect sites on the nanotubes. Furthermore this is the first case where the active sites are nanoparticles of copper metal, rather than metal oxide nanoparticles (namely oxides of iron(II)/(III)) as was found to be the case in the previous examples.

Anesthetics↗

The theory of non-Cottrellian diffusion on the surface of a sphere or truncated sphere.

A method is developed whereby spherical and other particles can be derivatised with electroactive species on their surface and then immobilised on the surface of an electrode. The chronoamperometric and voltammetric responses in the limit of reversible electrode kinetics are modelled using a theory of charge movement over the surface of the spheres where this movement is considered as a diffusional process. The model is extended to include different distributions of sphere radii and to model the scenario of truncated spheres resting on the electrode surface. It is found that a good estimation of the truncation angle can be found by fitting the experimental data with theoretical predictions.

Journal Article↗

Oxygenated edge plane sites slow the electron transfer of the ferro-/ferricyanide redox couple at graphite electrodes.

The electron transfer kinetics of ferrocyanide, potassium hexachloroiridate(III), hexaammineruthenium(III) chloride, and N,N,N',N'-tetramethyl-p-phenylenediamine (TMPD) have been examined at basal plane and edge plane pyrolytic graphite electrodes which have been allowed to oxidise in air for various periods of time. It is demonstrated via voltammetric and X-ray photoelectron spectroscopy (XPS) analysis that oxygenated species formed at edge plane sites/defects decrease the electron transfer kinetics of ferrocyanide but that the rates for potassium hexachloroiridate(III), hexaammineruthenium(III) chloride and TMPD are insensitive to the oxygenated species. The behaviour of the ferro-/ferricyanide couple contrasts with that seen on single-walled carbon nanotubes where oxygenation of the tube ends is known to speed up the electron transfer kinetics (A. Chou, T. Bocking, N. K. Singh, J. J. Gooding, Chem. Commun. 2005, 842); the possible reasons for this contrasting behaviour are discussed.

Journal Article↗

Nano-electrochemical detection of hydrogen or protons using palladium nanoparticles: distinguishing surface and bulk hydrogen.

The benefits of using nanoparticle-modified electrodes are exemplified through the electrochemical detection of protons and/or hydrogen. It is shown that a palladium-nanoparticle-modified boron-doped diamond allows voltammetric information relating to the relative roles played by the surface and the bulk metal to be obtained for the proton-hydrogen system at palladium surfaces which is not accessible using palladium macroelectrodes or microelectrodes.

Journal Article↗

Electrochemically polymerised composites of multi-walled carbon nanotubes and poly(vinylferrocene) and their use as modified electrodes: application to glucose sensing.

We report electrochemical composites of multi-walled carbon nanotubes (MWCNTs) with poly(vinylferrocene) (PVF). The polymeric architecture is prepared by first immobilising the MWCNTs onto a glassy carbon substrate, which acts to introduce electrical current into the composite, with the MWCNTs acting as 'molecular wires'. PVF films of varying surface coverages can be obtained by simply controlling the time a constant potential of +0.7 V (vs. Ag) wire is applied; with the characteristics of the derivatised MWCNTs examined by cyclic voltammetry and scanning electron microscopy. The application of the composite for glucose determination in aqueous solutions was investigated using linear sweep voltammetry, where it was found that the composites supported on glassy carbon substrates are superior to bare glassy carbon electrodes polymerised with PVF, likely due to the comparatively higher number of electrocatalytic centres in the former. This protocol was successfully transferred to prepare a PVF-MWCNT-paste electrode which was applied to glucose detection in diluted laked horse blood. The obtained results show potential and promising practical application for the polymer-derivatised MWCNT-modified electrodes in amperometric sensors for glucose determination.

Biomarkers↗

Mathematical modelling and simulation of adsorption processes at spherical microparticles.

A model for the adsorption process at spherical microparticles under transient diffusion conditions has been developed and solved using numerical simulation. This model allowed us to demonstrate that the system is controlled by two main dimensionless parameters: the adsorption rate constant ka' and the saturation parameter beta. Analytical models for the adsorption process at spherical microparticles under steady-state mass transport conditions have been derived. These models use previously developed empirical relationships for the calculation of the mass transfer coefficient (kc). The properties of the system were studied for both the case where mass transport is described by diffusion only and the case where it is the result of a coupled diffusion/convection process. These mathematical tools were then used to analyse the results obtained for the uptake of CuII by glassy carbon powder modified with the monomer L-cysteine methyl ester and to extract a minimum value for the adsorption rate constant which was found to be of the order of 10(-4) cm s(-1).

Journal Article↗