Search PubMed⌕ Search

Biomedical subjects

Richard C Pais

Publications and source records attributed to Richard C Pais.

2 recordsLinked to original sources

Database design and implementation for quantitative image analysis research.

Quantitative image analysis (QIA) goes beyond subjective visual assessment to provide computer measurements of the image content, typically following image segmentation to identify anatomical regions of interest (ROIs). Commercially available picture archiving and communication systems focus on storage of image data. They are not well suited to efficient storage and mining of new types of quantitative data. In this paper, we present a system that integrates image segmentation, quantitation, and characterization with database and data mining facilities. The paper includes generic process and data models for QIA in medicine and describes their practical use. The data model is based upon the Digital Imaging and Communications in Medicine (DICOM) data hierarchy, which is augmented with tables to store segmentation results (ROIs) and quantitative data from multiple experiments. Data mining for statistical analysis of the quantitative data is described along with example queries. The database is implemented in PostgreSQL on a UNIX server. Database requirements and capabilities are illustrated through two quantitative imaging experiments related to lung cancer screening and assessment of emphysema lung disease. The system can manage the large amounts of quantitative data necessary for research, development, and deployment of computer-aided diagnosis tools.

Algorithms↗

Comparison of treatment response classifications between unidimensional, bidimensional, and volumetric measurements of metastatic lung lesions on chest computed tomography.

RATIONALE AND OBJECTIVES: To study the agreement in treatment response classifications between unidimensional (1D), bidimensional (2D), and volumetric (3D) methods of measuring metastatic lung nodules on chest computed tomography (CT). MATERIALS AND METHODS: Chest CT scans of 15 patients undergoing treatment for metastatic colorectal, renal cell, or breast carcinoma to the lungs were analyzed. CT images were acquired with 3 mm collimation and contiguous reconstruction. Two or three lung lesions were selected for each patient. Lesions were analyzed at baseline and two follow-up intervals of 1-4 months. 1D and 2D measurements were made with electronic calipers, while nodule volume was measured using a semiautomated segmentation system. Following the World Health Organization and RECIST (Response Evaluation Criteria in Solid Tumors) criteria, patients were categorized into four treatment response classifications. Volumetric criteria were used to classify response based on 3D measurements. RESULTS: Thirty-two lesions from 15 patients were analyzed. Because each patient had a baseline and two follow-up scans, this yielded 30 response classifications for each measurement technique. The 1D, 2D, and 3D measurements were concordant in 21 of 30 classifications. The 1D and 3D measurements were concordant in 29 of 30 classifications, while the 2D and 3D measurements were concordant in 23 of 30 classifications. Level of agreement among the three methods was measured using a kappa statistic (K). For 1D compared with 3D, K = 0.739 +/- 0.345 (visits 1, 2) and 0.273 +/- 0.323 (visits 2, 3). For 2D compared with 3D, K = 0.655 +/- 0.325 (visits 1, 2) and 0.200 +/- 0.208 (visits 2, 3). Agreement among the methods for round and ovoid nodules was also fair to poor. CONCLUSION: The three methods of tumor measurement show fair to poor agreement in treatment response classification. These findings have negative implications for the accuracy in which patients are classified under the World Health Organization or RECIST criteria and managed under cancer treatment protocols.

Breast Neoplasms↗