Search PubMed⌕ Search

Biomedical subjects

Richard Bibb

Publications and source records attributed to Richard Bibb.

6 recordsLinked to original sources

The 3-dimensional construction of the average 11-year-old child face: a clinical evaluation and application.

PURPOSE: This article describes construction of the average face and its application in the clinical environment. SUBJECTS AND METHODS: A total of 72 children, mean age 11.8 years, were selected for the study. Laser-scanned images of the subjects were obtained under a reproducible and controlled environment with 2 Minolta Vivid 900 (Minolta, Osaka, Japan) optical laser-scanning devices assembled as a stereo pair. A set of left and right scanned images was taken for each subject and each scan took an average of 2.5 seconds. These scanned images were processed and merged to form a composite 3-dimensional soft tissue reproduction of the subjects using commercially-available reverse modeling software. The differences in facial morphology were measured using shell deviation color maps. The average face was used to compare differences between male and female groups and 3 subjects with craniofacial anomalies. RESULTS: The difference between the average male and female face was 0.460 +/- 0.353 mm. The areas of greatest deviation were at the zygomatic area and lower jaw line, with the males being more prominent. The results of the surface deviation between the subjects with craniofacial anomalies were significant. CONCLUSIONS: The construction of the average face provides an interesting perspective into measuring changes in groups of patients and also acts as a useful template for the comparison of craniofacial anomalies.

Cephalometry↗

Use of CAD/CAM technology to fabricate a removable partial denture framework.

This article reports on the first patient-fitted chromium cobalt removable partial denture framework produced by computer-assisted design, computer-assisted manufacture and rapid prototype technologies. Once the dental cast was scanned, virtual surveying and design of the framework on a 3-dimensional computer model was accomplished. A rapid prototype machine was used for direct fabrication of the alloy framework. Traditional finishing techniques were applied, the framework was assessed by a clinician in a conventional manner, fitted to the patient, and judged to be satisfactory by both the patient and clinician.

Aged↗

Medical rapid prototyping technologies: state of the art and current limitations for application in oral and maxillofacial surgery.

PURPOSE: We describe state-of-the-art software and hardware requirements for the manufacture of high quality medical models manufactured using medical rapid prototyping. The limitations of medical models, the source of artefacts, and their physical appearance are illustrated along with remedies for their removal. MATERIALS AND METHODS: Medical models were built using predominantly stereolithography and fused deposition modeling at both institutions over a period of 6 years. A combined total of 350 models have been produced for a range of maxillofacial, neurosurgical, and orthopedic applications. Stereolithography, fused deposition modeling, computerized numerical milling, and other technologies are described along with computer software requirements. RESULTS: A range of unwanted artefacts that create distortions on medical models have been identified. These include data import, computed tomography gantry distortion, metal, motion, surface roughness due to support structure removal or surface modeling, and image data thresholding. The source of the artefact has been related to the patient, imaging modality performance, or the modeling technology. Discussion as to the significance of the artefacts on clinical use is provided. CONCLUSIONS: It is recommended that models of human anatomy generated by medical rapid prototyping are subject to rigorous quality assurance at all stages of the manufacturing process. Clinicians should be aware of potential areas for inaccuracies within models and review the source images in cases where model integrity is in doubt.

Artifacts↗

The development of a collaborative medical modelling service: organisational and technical considerations.

We describe the steps, problems, pitfalls and modifications in the development of a collaborative medical modelling service for a general hospital in the United Kingdom. We emphasise the value of having as much control as possible in the hands of clinicians so that the maximum relevant information can be obtained at minimum cost. Three-dimensional imaging, modelling and planning are now essential parts of any reconstructive surgery unit and must be adapted to make them as user friendly as possible for clinicians.

Computer-Aided Design↗

A technique for fabricating patterns for removable partial denture frameworks using digitized casts and electronic surveying.

Although computer-aided design and manufacture techniques have shown some promising applications in the fabrication of crowns, inlays, and maxillofacial and oral surgery, the field of removable prosthodontics has not embraced these technologies so far. This article describes the development and investigation of computer-aided techniques that may eventually enable prosthodontic procedures such as surveying and the production of sacrificial patterns to be performed digitally. A 3-dimensional computer model of a conventional cast from a patient was obtained using an optical surface capture device (a scanner). The shape of a number of components of a removable partial denture framework was modeled on the 3-dimensional scan electronically, using computer-aided design software. A physical plastic shape of the components was produced using a Rapid Prototyping machine and used as a sacrificial pattern. Techniques to allow digital cast surveying before the production of sacrificial patterns were also developed. The results show that digital dental surveying and machine-produced sacrificial patterns can be accomplished. This article forms a basis for further developments leading to a fully integrated approach to the computer-aided design and fabrication of removable partial denture frameworks.

Computer Simulation↗

Toward identifying specification requirements for digital bone-anchored prosthesis design incorporating substructure fabrication: a pilot study.

PURPOSE: This paper is the first in a series that aims to identify the specification requirements for advanced digital technologies that may be used to design and fabricate complex, soft tissue facial prostheses. MATERIALS AND METHODS: Following a review of previously reported techniques, appropriate and currently available technologies were selected and applied in a pilot study. This study uses a range of optical surface scanning, computerized tomography, computer-aided design, and rapid prototyping technologies to capture, design, and fabricate a bone-anchored auricular prosthesis, including the retentive components. The techniques are assessed in terms of their effectiveness, and the results are used to identify future research and specification requirements to direct developments. RESULTS: The case study identifies that while digital technologies may be used to design implant-retained facial prostheses, many limitations need to be addressed to make the techniques clinically viable. It also identifies the need to develop a more robust specification that covers areas such as resolution, accuracy, materials, and design, against which potential technologies may be assessed. CONCLUSION: There is a need to develop a specification against which potential technologies may be assessed for their suitability in soft tissue facial prosthetics. The specification will be developed using further experimental research studies.

Biocompatible Materials↗