Search PubMed⌕ Search

Biomedical subjects

Richard A Montagna

Publications and source records attributed to Richard A Montagna.

6 recordsLinked to original sources

Microfluidic biosensor for the serotype-specific detection of dengue virus RNA.

The development of a microfluidic biosensor with fluorescence detection for the rapid, sensitive, and serotype-specific detection of Dengue virus is presented. The biosensor chip consists of poly(dimethylsiloxane) (PDMS) substrate with fabricated microchannels and a glass substrate used to seal the microchannels. These two substrates are packaged within a pressure-closed Plexiglas housing to provide a watertight reversible sealing at the PDMS-glass interface. The ability to reversibly seal the device permits easy disassembly and quick interchange of the device parts, which is ideal for developmental purposes. The biosensor employs a magnetic bead-based sandwich hybridization system in conjugation with liposome amplification for the specific detection of nucleic acids. The concentrations of the various biosensor components were optimized using a synthesized fragment of Dengue virus RNA. To evaluate the sensitivity of the assay, two detection systems, based on fluorescence measurements of intact and lysed liposomes, were analyzed. The entire analysis was complete within 20 min (including incubation time) with RNA detection limits of 0.125 nM and 50 pM for intact and lysed liposome detection systems, respectively. Subsequently, the biosensor was applied to the analysis of actual RNA obtained from Dengue virus serotypes 1-4. The resulting signals were compared to those obtained using standard electrochemiluminescence detection and shown to correspond perfectly with respect to serotype identification.

Base Sequence↗

Development of a microfluidic biosensor module for pathogen detection.

The development of a microfluidic biosensor module with fluorescence detection for the identification of pathogenic organisms and viruses is presented in this article. The microfluidic biosensor consists of a network of microchannels fabricated in polydimethylsiloxane (PDMS) substrate. The microchannels are sealed with a glass substrate and packed in a Plexiglas housing to provide connection to the macro-world and ensure leakage-free flow operation. Reversible sealing permits easy disassembly for cleaning and replacing the microfluidic channels. The fluidic flow is generated by an applied positive pressure gradient, and the module can be operated under continuous solution flow of up to 80 microL min(-1). The biosensor recognition principle is based on DNA/RNA hybridization and liposome signal amplification. Superparamagnetic beads are incorporated into the system as a mobile solid support and are an essential part of the analysis scheme. In this study, the design, fabrication and the optimization of concentrations and amounts of the different biosensor components are carried out. The total time required for an assay is only 15 min including sample incubation time. The biosensor module is designed so that it can be easily integrated with a micro total analysis system, which will combine sample preparation and detection steps onto a single chip.

Bacteria↗

Development of an immunomagnetic bead-immunoliposome fluorescence assay for rapid detection of Escherichia coli O157:H7 in aqueous samples and comparison of the assay with a standard microbiological method.

The objective of this study was to develop and optimize a protocol for the rapid detection of Escherichia coli O157:H7 in aqueous samples by a combined immunomagnetic bead-immunoliposome (IMB/IL) fluorescence assay. The protocol consisted of the filtration or centrifugation of 30- to 100-ml samples followed by incubation of the filter membranes or pellet with anti-E. coli O157:H7 immunomagnetic beads in growth medium specific for E. coli O157:H7. The resulting E. coli O157:H7-immunomagnetic bead complexes were isolated by magnetic separation, washed, and incubated with sulforhodamine B-containing immunoliposomes specific for E. coli O157:H7; the final immunomagnetic bead-E. coli O157:H7-immunoliposome complexes were again isolated by magnetic separation, washed, and lysed with a n-octyl-beta-d-glucopyranoside to release sulforhodamine B. The final protocol took less than 8 h to complete and had a detection limit of less than 1 CFU of E. coli O157:H7 per ml in various aqueous matrices, including apple juice and cider. To validate the protocol at an independent facility, 100-ml samples of groundwater with and without E. coli O157:H7 (15 CFU) were analyzed by a public health laboratory using the optimized protocol and a standard microbiological method. While the IMB/IL fluorescence assay was able to identify E. coli O157:H7-containing samples with 100% accuracy, the standard microbiological method was unable to distinguish E. coli O157:H7-spiked samples from negative controls without further extensive workup. These results demonstrate the feasibility of using immunomagnetic beads in combination with sulforhodamine B-encapsulating immunoliposomes for the rapid detection of E. coli O157:H7 in aqueous samples.

Beverages↗

A rapid biosensor for viable B. anthracis spores.

A simple membrane-strip-based biosensor assay has been combined with a nucleic acid sequence-based amplification (NASBA) reaction for rapid (4 h) detection of a small number (ten) of viable B. anthracis spores. The biosensor is based on identification of a unique mRNA sequence from one of the anthrax toxin genes, the protective antigen ( pag), encoded on the toxin plasmid, pXO1, and thus provides high specificity toward B. anthracis. Previously, the anthrax toxins activator ( atxA) mRNA had been used in our laboratory for the development of a biosensor for the detection of a single B. anthracis spore within 12 h. Changing the target sequence to the pag mRNA provided the ability to shorten the overall assay time significantly. The vaccine strain of B. anthracis (Sterne strain) was used in all experiments. A 500-microL sample containing as few as ten spores was mixed with 500 microL growth medium and incubated for 30 min for spore germination and mRNA production. Thus, only spores that are viable were detected. Subsequently, RNA was extracted from lysed cells, selectively amplified using NASBA, and rapidly identified by the biosensor. While the biosensor assay requires only 15 min assay time, the overall process takes 4 h for detection of ten viable B. anthracis spores, and is shortened significantly if more spores are present. The biosensor is based on an oligonucleotide sandwich-hybridization assay format. It uses a membrane flow-through system with an immobilized DNA probe that hybridizes with the target sequence. Signal amplification is provided when the target sequence hybridizes to a second DNA probe that has been coupled to liposomes encapsulating the dye sulforhodamine B. The amount of liposomes captured in the detection zone can be read visually or quantified with a hand-held reflectometer. The biosensor can detect as little as 1 fmol target mRNA (1 nmol L(-1)). Specificity analysis revealed no cross-reactivity with 11 organisms tested, among them closely related species such as B. cereus, B. megaterium, B. subtilis, B. thuringiensis, Lactococcus lactis, Lactobacillus plantarum, and Chlostridium butyricum. Also, no false positive signals were obtained from nonviable spores. We suggest that this inexpensive biosensor is a viable option for rapid, on-site analysis providing highly specific data on the presence of viable B. anthracis spores.

Bacillus anthracis↗

Multi-analyte single-membrane biosensor for the serotype-specific detection of Dengue virus.

A multi-analyte biosensor based on nucleic acid hybridization and liposome signal amplification was developed for the rapid serotype-specific detection of Dengue virus. After RNA amplification, detection of Dengue virus specific serotypes can be accomplished using a single analysis within 25 min. The multi-analyte biosensor is based on single-analyte assays (see Baeumner et al (2002) Anal Chem 74:1442-1448) developed earlier in which four analyses were required for specific serotype identification of Dengue virus samples. The multi-analyte biosensor employs generic and serotype-specific DNA probes, which hybridize with Dengue RNA that is amplified by the isothermal nucleic acid sequence based amplification (NASBA) reaction. The generic probe (reporter probe) is coupled to dye-entrapping liposomes and can hybridize to all four Dengue serotypes, while the serotype-specific probes (capture probes) are immobilized through biotin-streptavidin interaction on the surface of a polyethersulfone membrane strip in separate locations. A mixture of amplified Dengue virus RNA sequences and liposomes is applied to the membrane and allowed to migrate up along the test strip. After the liposome-target sequence complexes hybridize to the specific probes immobilized in the capture zones of the membrane strip, the Dengue serotype present in the sample can be determined. The amount of liposomes immobilized in the various capture zones directly correlates to the amount of viral RNA in the sample and can be quantified by a portable reflectometer. The specific arrangement of the capture zones and the use of unlabeled oligonucleotides (cold probes) enabled us to dramatically reduce the cross-reactivity of Dengue virus serotypes. Therefore, a single biosensor can be used to detect the exact Dengue serotype present in the sample. In addition, the biosensor can simultaneously detect two serotypes and so it is useful for the identification of possible concurrent infections found in clinical samples. The various biosensor components have been optimized with respect to specificity and sensitivity, and the system has been ultimately tested using blind coded samples. The biosensor demonstrated 92% reliability in Dengue serotype determination. Following isothermal amplification of the target sequences, the biosensor had a detection limit of 50 RNA molecules for serotype 2, 500 RNA molecules for serotypes 3 and 4, and 50,000 molecules for serotype 1. The multi-analyte biosensor is portable, inexpensive, and very easy to use and represents an alternative to current detection methods coupled with nucleic acid amplification reactions such as electrochemiluminescence, or those based on more expensive and time consuming methods such as ELISA or tissue culture.

Biosensing Techniques↗

Biosensor for dengue virus detection: sensitive, rapid, and serotype specific.

A serotype-specific RNA biosensor was developed for the rapid detection of Dengue virus (serotypes 1-4) in blood samples. After RNA amplification, the biosensor allows the rapid detection of Dengue virus RNA in only 15 min. In addition, the biosensor is portable, inexpensive, and very easy to use, making it an ideal detection system for point-of-care and field applications. The biosensor is coupled to the isothermal nucleic acid sequence-based amplification (NASBA) technique with which small amounts of virus RNA are amplified using a simple water bath. During the NASBA reaction, a generic sequence is attached to all RNA molecules as described earlier (Wu, S. J.; Lee, E. M.; Putvatana, R.; Shurtliff, R. N.; Porter, K R.; Suharyono, W.; Watt, D. M.; King, C. C.; Murphy, G. S.; Hayes, C. G.; Romano, J. W. J. Clin. Microbiol. 2001, 39, 2794-2798.). It has been shown earlier that Dengue virus can be detected specifically using two DNA probes: a first probe hybridized with the attached generic sequence and, therefore, bound to every amplified RNA molecule; and a second probe either bound to all four Dengue virus serotypes or chosen to be specific for only one serotype. These probes were utilized in the biosensor described in this publication. For a generic Dengue virus biosensor, the second probe is complementary to a conserved region found in all Dengue serotypes. For identification of the individual Dengue virus serotypes, four serotype-specific probes were developed (Wu, S. J.; Lee, E. M.; Putvatana, R.; Shurtiff, R. N.; Porter, K. R.; Suharyono, W.; Watt, D. M.; King, C. C.; Murphy, G. S.; Hayes, C. G.; Romano, J. W. J. Clin. Microbiol. 2001, 39, 2794-2798.). The biosensor is a membrane-based DNA/RNA hybridization system using liposome amplification. The generic DNA probe (reporter probe) is coupled to the outside of dye-encapsulating liposomes. The conserved or Dengue serotype specific probes (capture probes) are immobilized on a polyethersulfone membrane strip. Liposomes are mixed with amplified target sequence and are then applied to the membrane. The mixture is allowed to migrate along the test strip, and the liposome-target sequence complexes are immobilized in the capture zone via hybridization of the capture probe with target sequence. The amount of liposomes present in the immobilized complex is directly proportional to the amount of target sequence present in the sample and can be quantified using a portable reflectometer. The different biosensor components have been optimized with respect to sensitivity and, foremost, specificity toward the different serotypes. An excellent correlation to a laboratory-based detection system was demonstrated. Finally, the assay was tested using a limited number of clinical human serum samples. Although Dengue serotypes 1, 2 and 4 were identified correctly, serotype 3 displayed low cross-reactivity with biosensors designed for detection of serotypes 1 and 4.

Animals↗