Capillary electrophoresis and fluorescence anisotropy for quantitative analysis of peptide-protein interactions using JAK2 and SH2-Bbeta as a model system.

Fluorescence anisotropy capillary electrophoresis (FACE) and affinity probe capillary electrophoresis (APCE) with laser-induced fluorescence detection were evaluated for analysis of peptide-protein interactions with rapid binding kinetics. The Src homology 2 domain of protein SH2-Bbeta (SH2-Bbeta (525-670)) and a tyrosine-phosphorylated peptide corresponding to the binding sequence of JAK2 were used as a model system. For peptide labeled with fluorescein, the K(d) = 82 +/- 7 nM as measured by fluorescence anisotropy (FA). APCE assays had a limit of detection (LOD) of 100 nM or 12 amol injected for SH2-Bbeta (525-670). The separation time of 4 s, achieved using an electric field of 2860 V/cm on 7-cm-long capillaries, was on the same time scale as complex dissociation allowing K(d) (101 +/- 12 nM in good agreement with FA measurements) and dissociation rate (k(off) = 0.95 +/- 0.02 s(-)(1) corresponding to a half-life of 0.73 s) to be determined. This measurement represents a 30-fold higher rate of complex dissociation than what had previously been measurable by nonequilibrium CE analysis of equilibrium mixtures. Using FACE, the protein was detected with an LOD of 300 nM or 7.5 fmol injected. FACE was not used for determining K(d) or k(off); however, this method provided better separation resolution for multiple forms of the protein than APCE. Both methods were found suitable for analysis of cell lysate. These results demonstrate that FACE and APCE may be useful complements to existing techniques for exploring binding interactions with rapid kinetics.

Adaptor Proteins, Signal Transducing↗

Affinity assays using fluorescence anisotropy with capillary electrophoresis separation.

A novel approach to detecting affinity interactions that combines fluorescence anisotropy with capillary electrophoresis (FACE) was developed. In the method, sample is injected into a capillary filled with buffer that contains a fluorescent probe that possesses low fluorescence anisotropy. If proteins or other large molecules in the sample bind the fluorescent probe, their migration through the capillary can be detected as a positive anisotropy shift. Thus, the method provides both separation and confirmation of binding to the probe. Calculations based on combining the Perrin equation and dissociation constant were used to predict the effect of conditions on aniostropy detection. These calculations predict that low probe concentrations yield the best sensitivity while higher concentrations increase the dynamic range for detection of binding partner. The assay was applied to detection of G proteins using BODIPY FL GTPgammaS as the fluorescent probe. Experimental measurements exhibited trends in anisotropy with varying probe and protein concentrations that were consistent with the calculations. The limit of detection for G(alphai1) was 3 nM when the electrophoresis buffer contained 250 nM BODIPY FL GTPgammaS. FACE affinity assay is envisioned as a method that can quantify selected binding partners and screen complex samples for compounds that possess affinity for a particular small molecule that is used as a probe.

Electrophoresis, Capillary↗

Single-cell immunosensors for protein detection.

A single-cell detector is described that combines the natural signal amplification of whole-cell biosensors with the flexibility and specificity of immunological recognition. An immune cell that expresses receptors for the constant region of immunoglobulin G (IgG) is loaded with a Ca(2+)-indicating dye and with antibodies directed against the protein of interest. Introduction of a multivalent protein antigen causes cross-linking of the receptors, which results in a detectable increase in the concentration of cytosolic Ca(2+). Some immune cell lines respond to stimulation with oscillations in their cytosolic Ca(2+) levels that complicate their use as detectors. The human monocytic cell line U-937, when treated with the cytokine interferon-gamma, produces a large, short-lived Ca(2+) signal in response to cross-linking of its high-affinity IgG receptors. U-937 was therefore chosen for development as an immunity-based detector. Human and rabbit antibodies are found to effectively stimulate the cell, causing a prompt and transient response. The cell is able to respond to repeated stimulation, though the response diminishes during rapid stimulation. Ovalbumin can be detected in micromolar concentrations. Possible fundamental constraints on the size of a detectable analyte are discussed.

Biosensing Techniques↗

Microfluidic device for single-cell analysis.

We have developed a novel microfluidic device constructed from poly(dimethylsiloxane) using multilayer soft lithography technology for the analysis of single cells. The microfluidic network enables the passive and gentle separation of a single cell from the bulk cell suspension, and integrated valves and pumps enable the precise delivery of nanoliter volumes of reagents to that cell. Various applications are demonstrated, including cell viability assays, ionophore-mediated intracellular Ca2+ flux measurements, and multistep receptor-mediated Ca2+ measurements. These assays, and others, are achieved with significant improvements in reagent consumption, analysis time, and temporal resolution over macroscale alternatives.

Calcium↗

Surface plasmon resonance detection for capillary electrophoresis separations.

A miniaturized surface plasmon resonance sensor has been used as an on-line detector for capillary electrophoresis separations. The capillary was modified slightly to shield the sensor electronics from the high voltages applied during the separation. A three-component mixture of high refractive index materials was separated and detected at the millimolar level by an untreated gold-sensing surface. A simple protein immobilization procedure was used to functionalize the surface for selective protein detection. A hybrid buffer system was developed, in which both the deposition of immobilized protein layers and the electrophoretic delivery of protein analytes were optimized. The detection system has a reproducibility of 15%, a dynamic range of 3 orders of magnitude, and a detection limit for IgG of 2 fmol.

Journal Article↗

Functional immobilization of a ligand-activated G-protein-coupled receptor.

G-protein-coupled receptors (GPCRs) mediate the majority of cellular responses to hormones and neurotransmitters. They are the largest family of receptors in the human genome and constitute the largest class of targets for drug discovery. To facilitate studies of GPCR activation and interactions with other proteins, we developed a simple method to immobilize a functional, detergent-solubilized GPCR on gold and glass surfaces. The beta(2) adrenergic receptor (beta(2)AR), a prototypical GPCR, was purified and labeled with a reporter fluorophore at a conformationally sensitive site. The detergent-soluble fluorescent beta(2)AR was immobilized through its amino-terminal FLAG epitope on a surface layered with biotinylated bovine serum albumin, avidin, and biotinylated M1 antibody. Agonist activation of the beta(2)AR was monitored in real time by fluorescence microscopy. This approach will make it possible to study conformational dynamics of single immobilized receptors and to generate arrays of functional GPCRs for novel high-throughput screening strategies.

Animals↗

Analysis of biomolecular interactions using a miniaturized surface plasmon resonance sensor.

A commercially available miniaturized surface plasmon resonance sensor has been investigated for its applicability to biological interaction analysis. The sensor was found to exhibit excellent repeatability and linearity for high-refractive index solutions and good reproducibility for the binding of proteins. Its detection limit for the monoclonal antibody M1 was found to be 2.1 fmol, which corresponds to a surface concentration of 21 pg/mm2. Simple surface immobilization procedures relying on biotin/avidin or glycoprotein/lectin chemistry have been explored. Equilibrium dissociation constants for the binding of the FLAG peptide to its monoclonal antibody (M1) and for the binding of concanavalin A to a glycoprotein have been determined. The close agreement of these measurements with values obtained by surface fluorescence microscopy and fluorescence correlation spectroscopy helps to validate the use of this device. Thus, this sensor shows promise as an inexpensive, portable, and accurate tool for bioanalytical applications in laboratory and clinical settings.

Animals↗