Interaction between aberrations to improve or reduce visual performance.

PURPOSE: To investigate how pairs of Zernike modes interact to increase or decrease visual acuity. SETTING: Visual Optics Institute, College of Optometry, University of Houston, Houston, Texas, USA. METHODS: Subjects read aberrated and unaberrated visual acuity charts 3 times. Each aberrated chart was produced by convolving an aberrated point-spread function with an unaberrated acuity chart. Point-spread functions were defined by 4 pairs of Zernike modes. For each pair, 9 combinations were used, ranging from all aberration being loaded into the first mode to all aberration being loaded into the second mode. The root mean square (RMS) wavefront error always totaled 0.25 microm (6.0 mm pupil), a level similar to the aberration induced by traditional flying small-spot laser refractive surgeries. RESULTS: For all conditions (except the unaberrated charts), visual acuity decreased. Acuity varied significantly depending on which modes were mixed and the relative contribution of each mode. Modes 2 radial orders apart and having the same sign and angular frequency tended to combine to increase visual acuity. Modes within the same radial order tended to combine to decrease acuity. CONCLUSIONS: For low levels of aberration, the RMS wavefront error is not a good predictor of visual acuity. Clinically, it is important to define how aberrations interact to optimize visual performance. New metrics of optical/neural performance that correlate better with clinical measures of visual performance need to be adopted or developed, as well as new clinically viable measures of visual performance that are sensitive to subtle changes in optical performance.

Adult↗

Comparison of monochromatic ocular aberrations measured with an objective cross-cylinder aberroscope and a Shack-Hartmann aberrometer.

Repeated measures of wavefront aberrations were taken along the line-of-sight of seven eyes using two instruments: an objective, cross-cylinder aberroscope (OA) and a Shack-Hartmann (SH) aberrometer. Both instruments were implemented on the same optical table to facilitate interleaved measurements on the same eyes under similar experimental conditions. Variability of repeated measures of individual coefficients tended to be much greater for OA data than for SH data. Although Zernike coefficients obtained from a single measurement were generally larger when measured with the OA than with the SH, the averages across five trials were often smaller for the OA. The Zernike coefficients obtained from the two instruments were not significantly correlated. Radial modulation-transfer functions and point-spread functions derived from the two sets of measurements were similar for some subjects, but not all. When average Zernike coefficients were used to determine optical quality, the OA indicated superior optics in some eyes, but the reverse trend was true if Zernike coefficients from individual trials were used. Possible reasons for discrepancies between the OA and SH measurements include difference in sampling density, quality of data images, alignment errors, and temporal fluctuations. Multivariate statistical analysis indicated that the SH aberrometer discriminated between subjects much better than did the objective aberroscope.

Diagnostic Techniques, Ophthalmological↗

Visual acuity as a function of Zernike mode and level of root mean square error.

BACKGROUND: The coefficients of normalized Zernike expansion are orthogonal and reflect the relative contribution of each mode to the total root mean square (RMS) wavefront error. The relationship between the level of RMS wavefront error within a mode and its effect on visual performance is unknown. PURPOSE: To determine for various levels of RMS wavefront error how each mode of the normalized Zernike expansion for the second, third, and fourth orders affect high- and low-contrast acuity. METHODS: Three healthy optimally corrected cyclopleged subjects read aberrated and unaberrated high- and low-contrast logarithm of the minimum angle of resolution acuity charts monocularly through a 3-mm artificial pupil. Acuity was defined by the total number of letters read correctly up to the fifth miss. Aberrated and unaberrated charts were generated using a program called CTView. Six levels of RMS wavefront error were used (0.00, 0.05, 0.10, 0.15, 0.20, and 0.25 microm). Each level of RMS error was loaded into each mode of the second, third, and fourth radial orders individually for a total of 72 charts. Data were normalized by subject, and the normalized data were averaged across subjects. RESULTS: Across modes and within each mode as the level of RMS wavefront error increased above 0.05 microm of RMS wavefront error, visual acuity decreased in a linear fashion. Slopes of the linear fits varied depending on the mode. Modes near the center of the Zernike pyramid had steeper slopes than those near the edge. CONCLUSIONS: Increasing the RMS error within any single mode of the normalized Zernike expansion decreases visual acuity in a linear fashion. The slope of the best fitting linear equation varies with Zernike mode. Slopes near the center of the Zernike pyramid are steeper than those near the edge. Although the normalized Zernike expansion parcels RMS error orthogonally, the resulting effects on visual performance as measured by visual acuity are not orthogonal. New metrics of the combined effects of the optical and the neural transfer functions that are predictive of visual performance need to be developed.

Adult↗

Are all aberrations equal?

PURPOSE: To determine for a fixed RMS error (25 microm, over a 6-mm pupil) how each mode of the normalized Zernike polynomial (second through the fourth radial order) affects high and low contrast logMAR visual acuity. METHODS: Three healthy volunteers served as subjects. CTView was used to generate optically aberrated logMAR charts. Accommodation was paralyzed and pupils dilated. The foveal achromatic axis of the eye was aligned to a 3-mm pupil and the eye was optimally refracted. Aberrated acuity charts were read until five letters were missed. Data were normalized for each subject to the acuity obtained by reading unaberrated charts and plotted as letters lost as a function of Zernike mode. RESULTS: Defocus (Z2(0)) decreased letter acuity more than astigmatism (Z2(2), Z2(-2)). Coma (Z3(1), Z3(-1)) decreased acuity more than trefoil (Z3(3), Z3(-3)). Spherical aberration (Z4(0)) and secondary astigmatism (Z2(2), Z4(-2)) decreased acuity much more than quadrafoil (Z4(4), Z4(-4)). CONCLUSIONS: 1. For an equal amount of RMS error not all coefficients of the Zernike polynomial induce equivalent losses in high and low contrast logMAR acuity. 2. Wavefront error concentrated near the center of the pyramid adversely affects visual acuity more than modes near the edge of the pyramid. 3. Large changes in chart appearance are not reflected in equally large decreases in visual performance (ie, subjects could correctly identify highly aberrated letters). 4. Interactions between modes complicate weighting each Zernike mode for visual impact.

Adult↗

Standards for reporting the optical aberrations of eyes.

In response to a perceived need in the vision community, an OSA taskforce was formed at the 1999 topical meeting on vision science and its applications (VSIA-99) and charged with developing consensus recommendations on definitions, conventions, and standards for reporting of optical aberrations of human eyes. Progress reports were presented at the 1999 OSA annual meeting and at VSIA-2000 by the chairs of three taskforce subcommittees on (1) reference axes, (2) describing functions, and (3) model eyes.

Corneal Topography↗