Search PubMed⌕ Search

Biomedical subjects

Rangan Mallik

Publications and source records attributed to Rangan Mallik.

5 recordsLinked to original sources

Chromatographic analysis of carbamazepine binding to human serum albumin. II. Comparison of the Schiff base and N-hydroxysuccinimide immobilization methods.

Recent studies with carbamazepine on human serum albumin (HSA) columns have noted an appreciable degree of non-specific binding on supports prepared by the Schiff base immobilization method. This work examines an alternative immobilization method for HSA based on N-hydroxysuccinimide (NHS)-activated silica. This support was prepared by reacting HPLC-grade silica directly with disuccinimidyl carbonate. The resulting material was compared to an HSA support prepared by the Schiff base method in terms of its activity for carbamazepine and non-specific interactions with this drug. When examined by frontal analysis, both supports gave comparable association equilibrium constants for carbamazepine interactions with HSA ((0.53-0.55) x 10(4)M(-1) at 37 degrees C). However, columns prepared by the Schiff base method gave greater non-specific binding. These columns, as well as control columns prepared using the carbonyldiimidazole (CDI) immobilization method, were also evaluated for their non-specific binding to a variety of other solutes known to interact with HSA. From these results it was concluded that the NHS method was an attractive alternative to the Schiff base technique in the preparation of immobilized HSA for HPLC-based binding studies for carbamazepine. However, it was also noted that non-specific binding varies from one drug to the next in these immobilization methods, indicating that such properties should be evaluated on a case-by-case basis in the use and development of HSA columns for binding studies.

Carbamazepine↗

Applications of silica supports in affinity chromatography.

The combined use of silica-based chromatographic supports with immobilized affinity ligands can be used in many preparative and analytical applications. One example is the use of silica-based affinity columns in HPLC, giving rise to a method known as high-performance affinity chromatography (HPAC). This review discusses the role that silica has played in the development of affinity chromatography and HPAC and the applications of silica in these methods. This includes a discussion of the types of ligands that have been employed with silica and the methods by which these ligands have been immobilized. Various formats have also been presented for the use of silica in affinity chromatographic methods, including assays involving direct or indirect analyte detection, on-line or off-line affinity extraction, and chiral separations. The use of silica-based affinity columns in studies of biological systems based on zonal elution and frontal analysis methods will also be considered.

Adsorption↗

Affinity monolith chromatography.

The combined use of monolithic supports with selective affinity ligands as stationary phases has recently given rise to a new method known as affinity monolith chromatography (AMC). This review will discuss the basic principles behind AMC and examine the types of supports and ligands that have been employed in this method. Approaches for placing affinity ligands in monoliths will be considered, including methods based on covalent immobilization, biospecific adsorption, entrapment, and the formation of coordination complexes. Several reported applications will then be presented, such as the use of AMC for bioaffinity chromatography, immunoaffinity chromatography, immobilized metal-ion affinity chromatography, dye-ligand affinity chromatography, and biomimetic chromatography. Other applications that will be discussed are chiral separations and studies of biological interactions based on AMC.

Chromatography, Affinity↗

Affinity monoliths for ultrafast immunoextraction.

Affinity monoliths based on a copolymer of glycidyl methacrylate and ethylene dimethacrylate were developed for ultrafast immunoextractions. Rabbit immunoglobulin G (IgG) and anti-FITC antibodies were used as model ligands for this work. The antibody content of the monoliths was optimized by varying both the polymerization and immobilization conditions for preparing such supports. The temperature and porogen composition used during polymerization showed significant effects on monolith morphology and on the amount of antibodies that could be coupled to these materials. The effects of various immobilization procedures and coupling conditions were also evaluated, including the coupling temperature, pH, protein concentration, and use of high buffer concentrations. The maximum ligand density obtained for rabbit IgG was approximately 60 mg/g. When a 4.5 mm i.d. x 0.95 mm monolith disk containing anti-FITC antibodies was used, 95% extraction of fluorescein was achieved in 100 ms. These properties make such monoliths attractive for work in the rapid isolation of analytes from biological samples. Similar columns can be developed for other targets by varying the types of antibodies or binding agents placed within the monoliths.

Animals↗

High-performance affinity monolith chromatography: development and evaluation of human serum albumin columns.

Several immobilization methods were explored for the preparation of high-performance affinity monolithic columns containing human serum albumin (HSA). These monoliths were based on a copolymer of glycidyl methacrylate and ethylene dimethacrylate. In one method, the epoxy groups of this copolymer were used directly for the immobilization of HSA through its amine residues (i.e., the epoxy method); in other approaches, these epoxy groups were converted to diols for later use in the carbonyldiimidazole, disuccinimidyl carbonate, and Schiff base methods. Each HSA monolith was evaluated in terms of its total protein content and its retention of several model compounds, including (R/S)-warfarin and D/L-tryptophan. The greatest amount of immobilized HSA was obtained by the Schiff base method, whereas the epoxy method gave the lowest protein content. The Schiff base method also gave the best resolution in chiral separations of (R/S)-warfarin and D/L-tryptophan. All of the immobilization methods gave similar relative activities for HSA in its binding to (R)- and (S)-warfarin, but some differences were noted in the activity of the immobilized HSA for D- and L-tryptophan. The efficiency of these monoliths was found to be greater than that of silica-based HSA columns for (R/S)-warfarin (i.e., analytes with high retention), but little or no difference was seen for D- and L-tryptophan (analytes with weak retention).

Carbonates↗