Search PubMed⌕ Search

Biomedical subjects

R W Redington

Publications and source records attributed to R W Redington.

29 records · Page 2Linked to original sources

Detection and quantitation of myocardial infarction in vivo using transmission computed tomography.

In vivo studies were performed on 28 dogs to evaluate the usefulness of transmission computed tomography (CT) in the detection and quantitation of experimentally induced myocardial infarction. Intravenously administered contrast material was required to define the internal structure of the heart and to differentiate normal from infarcted tissue. Transmural infarcts with homogeneous central regions were visualized as areas of diminished contrast enhancement compared with the normal myocardium. All transmural infarcts of at least 24 hours' duration showed a surrounding border zone of patchy necrosis that was variable in size and had high CT numbers due to slow washout of the contrast material from this region. Infarct area determined from the images for individual slices correlated well (r = 0.976) with that calculated using pathology. The technique is very sensitive and can detect infarction within a papillary muscle. Nontransmural or patchy infarcts show up as areas of diffuse contrast enhancement without a central core of diminished enhancement. The distribution of the contrast material is similar to that of technetium-99m pyrophosphate in the border zone of the infarct in infusion studies, but in bolus studies it behaves more like thallium-201.

Animals↗

Myocardial infarction in dogs, demonstrated by non-enhanced computed tomography.

The capability of non-enhanced and enhanced CT scanning of the heart without ECG gating to detect myocardial infarction in living dogs was explored. CT findings were correlated with those at post mortem. In large transmural infarctions, areas of lower attenuation were detected without contrast medium enhancement and appeared as defects when intravenous contrast medium was administered. The infarct size as estimated on each CT scan correlated closely with post mortem values.

Animals↗

Dynamic computed tomography of the brain: techniques, data analysis, and applications.

Rapid sequence computed tomography (CT) scanning has many potential applications in studying intracranial physiologic events. However, visual inspection of these rapid sequence scans fails to extract the large amount of information inherent in the digital data. The concept of corrected mean transit time applied to rapid sequence scans after intravenous bolus injection of contrast material provides quantitative data on relative hemispheric flow. Use of histogram-based areas of interest permits accurate and reproducible identification of anatomic structures including arteries and gray and white matter. Gamma variate curve fit techniques reduce statistical noise. The concept of transit time can be expanded to the creation of functional CT images.

Blood Flow Velocity↗

Detection of patent coronary bypass grafts by computed tomography. A preliminary report.

Twenty-three coronary bypass graft patients were evaluated by a contrast-enhanced computed tomography (CT) technique to determine graft patency. Four to six 4.8-second sequenced scans with a 1-second interscan interval were obtained in each patient during the hand injection of 25-30 ml of contrast medium in a peripheral vein. Patency of grafts was determined by a characteristic contrast enhancement. The CT technique correlated with angiographic assessment of graft patency in 59 of 62 grafts (95%). We conclude that this relatively noninvasive technique shows promise as a method for determining coronary bypass graft patency.

Adult↗

[Experience with computed transmission tomography of the heart in vivo].

Cardiac computed tomography in its present form provides useful information about the heart for clinical use in patients with heart disease and for investigative work in such patients and living animals. Its great reconstructive power and unmatched density resolution are particularly advantageous in the study of ischemic heart disease. Because of its non-invasive character cardiac computed tomography has the potential of becoming an effective screening tool for large numbers of patients with suspected or known coronary heart disease. Other cardiac conditions such as valve disease and congenital lesions can also be examined with high diagnostic yield. However presently available scanners suffer from low repetion rate, long scan times and the fact that only one transverse cardiac level at a time can be obtained. The development which must be accomplished in order to eliminate these weaknesses is technically feasible. The availability of a dynamic cardiac scanner would greatly benefit the treatment of patients with heart disease and facilitate the inquiry into the pathophysiology of such diseases.

Angina Pectoris↗

Gated cardiac scanning: canine studies.

Retrospective electrocardiograph gating of data from a rotating detector fan beam computed tomography system was employed to produce end systolic and end diastolic images of the beating heart in a series of normal and experimentally infarcted canines. The gating window was typically less than 20% of the cardiac cycle, and the gated images showed superior spatial resolution compared with ungated images of the same cross section. Comparison of the scans of the normal and of the infarcted animals shows abnormal contrast enhancement of the myocardium in the region of the infarct, and the gating studies demonstrate dyskinetic behavior of the infarct zone.

Animals↗

Human exposure to 4.0-Tesla magnetic fields in a whole-body scanner.

Details are given for the design, construction, properties, and performance of a large, highly homogeneous magnet designed to permit whole-body magnetic resonance imaging and spectroscopy at 4 T. The magnet has an inductance of 1289 H and a stored energy of 33.4 MJ at rated field. The health of a group of 11 volunteers who had varying degrees of exposure to this field was followed over a 12-month period and no change that could be associated with this exposure was detected. A mild level of sensory experiences, apparently associated with motion within the field of the magnet, was reported by some of the volunteers during some of their exposures. A questionnaire regarding sensory effects associated with magnetic resonance scanners and possibly caused by the static magnetic field of these instruments, was given to nine respondents who had experience within both 1.5-T scanners and this 4-T scanner and to another group of 24 respondents who had experience only within 1.5-T scanners. For the sensations of vertigo, nausea, and metallic taste there was statistically significant (p less than 0.05) evidence for a field-dependent effect that was greater at 4 T. In addition, there was evidence for motion-induced magnetophosphenes caused by motion of the eyes within the static field. These results indicate the practicality of experimental whole-body body scanners operating at 4 T and the possibility of mild sensory effects in humans associated with motion within a static magnetic field. The results also indicate the likelihood of a wide margin of safety for the exposure of noncompromised patients to the static fields of conventional magnetic resonance scanners operated at 1.5 to 2 T and below.

Adult↗