Search PubMed⌕ Search

Biomedical subjects

R W Mann

Publications and source records attributed to R W Mann.

At least 73 records · Page 4Linked to original sources

Positive identification based on radiographic examination of the leg and foot. A case report.

The authors have presented a forensic anthropology case that established positive identification by comparison of antemortem and postmortem x-rays of the legs and feet. This case illustrates one method of ascertaining the identity of a burned and skeletonized victim. By careful reconstruction and examination of the skeleton, the investigators were able to determine not only age, race, and sex, but also trauma sustained to the head and left arm at the time of death. This case highlights the importance and application of clinical radiography in a legal context.

Anthropology, Physical↗

Calcaneus secundarius. Variation of a common accessory ossicle.

The calcaneus secundarius is an accessory ossicle of the anterior calcaneal facet. Dry bone examination of 1,367 calcanei revealed this trait 47 times (3.4%). Familiarity with the calcaneus secondarius may prove to be of clinical and radiographic value in distinguishing pathologic from normal variants in the calcaneus.

Adolescent↗

Contact pressures from an instrumented hip endoprosthesis.

A pressure-measuring Moore-type endoprosthesis was implanted in a seventy-three-year-old patient who had sustained a displaced fracture of the femoral neck. The measurement and telemetry of contact pressures in the hip began in the operating room, and data were acquired periodically for more than thirty-six months. Unexpectedly high localized contact pressures between the acetabular cartilage and the prosthesis were recorded. Early in the period of recovery, activities such as using a bedpan or performing isometric exercise produced pressures that were close to those recorded during normal walking. The highest pressure, eighteen megapascals, was recorded one year postoperatively, while the patient was rising from a chair. High pressures occurred in the superior and posterior aspects of the acetabulum.

Acetabulum↗

Limitations of the continuum assumption in cancellous bone.

Most existing stress analyses of the skeleton which consider cancellous bone assume that it can be modelled as a continuum. In this paper we develop a criterion for the validity of this assumption. The limitations of the continuum assumption appear in two areas: near biologic interfaces, and in areas of large stress gradients. These limitations are explored using a probabilistic line scanning model for density measurement, resulting in an estimate of density accuracy as a function of line length which is experimentally verified. Within three to five trabeculae of an interface, a continuum model is suspect. When results as predicted using continuum analyses vary by more than 20-30% over a distance spanning three to five trabeculae, the results are suspect.

Biomechanical Phenomena↗

Demography and pathology of an urban slave population from New Orleans.

Twenty-nine skeletons from the first cemetery in New Orleans provide significant new information about urban slavery in America. Dating as early as 1720 and used perhaps as late as 1810, the cemetery provided an identifiable sample of two whites, 13 blacks, one individual of possible Indian-white ancestry, and two possibly mulatto individuals. Numerous skeletal and dental lesions were noted in the series, and historical information was used in conjunction with the physical data to draw conclusions about rates and patterns of mortality. Pathological changes indicate that the cemetery contained individuals representing two slave occupational groups, house servants and laborers. This research provides information in the expanding area of Afro-American biohistorical research.

Black or African American↗

Variation of lumbar spine stiffness with load.

Mechanical studies of the Functional Spinal Unit (FSU) in-vitro have shown that the slopes of the load-displacement curves increase with load. This nonlinearity implies that the stiffness of the FSU is not constant over the range of physiologic loads, and that measurements obtained for FSU specimens through the application of individual loads cannot be summed to predict the response of the specimens to combined loads. Both experimental and analytical methods were developed in the present study to better quantify the nonlinear FSU load-displacement response and to calculate the coupled stiffness of FSU specimens at combined states of load reflecting in-vivo conditions. Results referenced to the center of the vertebral body indicate that lumbar FSU specimens are stiffer in flexion than in extension, and that FSU specimens loaded in flexion are stiffer at high loads than at low loads. The importance of combined load testing and a nonlinear interpretation of load-displacement data is demonstrated.

Biomechanical Phenomena↗

Contact pressures in the human hip joint measured in vivo.

The pressures on human articular cartilage have been measured in vivo. An instrumented femoral head prosthesis that telemeters interarticular pressure at 10 discrete locations 253 times per second was implanted in apposition to natural acetabular cartilage. Data were acquired during surgery, recovery, rehabilitation, and normal activity, for longer than 1 year after surgery. Pressure magnitudes were synchronized with body-segment kinematic data and foot-floor force measurements so as to locate transduced pressure areas on the natural acetabulum and correlate movement kinematics and dynamics with local cartilage pressures. The data reveal very high local (up to 18 MPa) and nonuniform pressures, with abrupt spatial and temporal gradients, that correlate well both in magnitude and distribution with in vitro data and computer simulations of synovial joint mechanics. Peak pressures in vivo are, however, considerably higher than pressures measured in vitro under the putative forces experienced by the joint in life, particularly in normal movements where cocontraction occurs in agonist and antagonist muscles across the hip joint. Thus, extant gait-analysis studies which apply inverse Newtonian calculations to infer joint forces establish the lower limit on such forces, since such analyses include only the net muscular torques about the joint and cannot account for the contribution of the increment in joint force due to muscular cocontraction. Our data also contribute to the understanding of normal synovial joint tribology and the possible role of mechanical factors in the deterioration evident in osteoarthritis. Further, design criteria for both partial and total hip replacement prostheses and specific aspects of rehabilitation protocols following hip surgery (e.g., the extent to which crutches and canes unload the hip joint) warrant reconsideration in light of the extraordinary high pressures measured during the activities of daily living.

Biomechanical Phenomena↗

Induction of heat-shock protein synthesis in chondrocytes at physiological temperatures.

Induction of heat-shock protein (HSP) synthesis is demonstrated in cultured calf-chondrocytes at temperatures shown to occur in normal human cartilage during experiments subjecting intact cadaverous hip joints to the parameters of level walking. A 70,000 MW heat-shock protein (HSP-70) is synthesized by chondrocytes at temperatures above 39 degrees C, while induction of synthesis of a 110,000 MW HSP only occurs at temperatures of 45 degrees C or greater. These differences in critical temperatures for induction, and data showing differences in kinetics of induction and repression of synthesis, suggest that there are differences in the mechanism of induction of the two HSPs. The duration of HSP synthesis and inhibition of synthesis of normal cellular proteins is directly proportional to the duration and magnitude of the temperature rise. Possible relationships between these new findings and the initiation and progression of degenerative joint disease are discussed.

Animals↗

Experimental temperature rise in human hip joint in vitro in simulated walking.

Although reported frictional coefficients in synovial joints are very low, a computer model of the human hip joint in simulated walking predicted a temperature rise of several degrees Celsius. To confirm this prediction, physical experiments were conducted in vitro on intact human hip joints dynamically loaded and articulated as in walking. Thermisters were placed in subchondral bone in both the acetabulum and femoral head, just below the cartilage layers. The surrounding saline bath was maintained at 37 degrees C. Measured temperatures as high as 2.5 degrees C above the 37 degrees C were recorded in the subchondral bone. Loading that simulated the stance/swing phases of gait but without articulation produced no significant increase in temperature; thus fluid flow per se is not significantly energy dissipative; the prime source is friction at the articulating surfaces.

Hip Joint↗

The frequency content of gait.

We address amplification of noise in double differentiation of position histories for dynamic analysis of gait. Measurements of the frequency domain characteristics of signal and noise are required to quantitatively assess errors in raw, filtered, and dynamic gait data. The results of a simple technique to determine the frequency content of gait using a population of 12 subjects and a total of 30 gait records is presented.

Biomechanical Phenomena↗

Mechanical properties of articular cartilage elucidated by osmotic loading and ultrasound.

The time response of surface displacement and acoustic impedance of in situ layers of articular cartilage were measured by using pulse-echo ultrasound. Disturbances were introduced by altering the osmotic pressure. Strongly nonlinear behavior was observed near physiological equilibrium. A model of articular cartilage is proposed which relates our results to cartilage microstructure.

Cartilage, Articular↗

Gait analysis--precise, rapid, automatic, 3-D position and orientation kinematics and dynamics.

A fully automatic optoelectronic photogrammetric technique is presented for measuring the spatial kinematics of human motion (both position and orientation) and estimating the inertial (net) dynamics. Calibration and verification showed that in a two-meter cube viewing volume, the system achieves one millimeter of accuracy and resolution in translation and 20 milliradians in rotation. Since double differentiation of generalized position data to determine accelerations amplifies noise, the frequency domain characteristics of the system were investigated. It was found that the noise and all other errors in the kinematic data contribute less than five percent error to the resulting dynamics.

Gait↗