Search PubMed⌕ Search

Biomedical subjects

R Vanderby

Publications and source records attributed to R Vanderby.

82 records · Page 5Linked to original sources

An evaluation of six synthetic casting materials: strength of cylinders in bending.

Six fiberglass casting tapes were evaluated in bending, using an unstable fracture model. Cylindrical casts were constructed and evaluated in bending at 2, 3, and 24 hours after application. Scotchcast Plus (3M, St. Paul, MN), Vet Cast II (3M), and Zim-Flex (Zimmer, Warsaw, IN) were significantly stronger than other materials at 2 hours; however, by 24 hours, casts constructed from Delta-Lite (Johnson & Johnson Products, New Brunswick, NJ) were strongest. Delta-Lite Conformable casts were significantly weaker at all times.

Casts, Surgical↗

An evaluation of fiberglass cast application techniques.

Cylindrical casts constructed from 2, 3, 4, and 5 inch widths of fiberglass casting material were evaluated for strength in bending using an unstable fracture model. Five-inch casting material produced the strongest casts. The effect of longitudinal splinting with 2-inch fiberglass tape was evaluated in cylindrical casts constructed from 4-inch tape. Casts with splints on the compression side or with splints on both the tension and compression sides were stronger in bending than casts with a single splint on the tension side or casts without splints.

Animals↗

Structural properties of interlocking nails, canine femora, and femur-interlocking nail constructs.

Using standard material testing techniques (bending stiffness, torsional stiffness, and maximum torque to failure or yield torque), the structural properties of interlocking nails (IN), canine femora, and IN/femur constructs were determined. Specimens that were tested included: 6 and 8 mm diameter IN with 5 to 10 screw holes (n = 18), and intact canine femora (n = 10), which also, with an IN inserted, formed the intact construct (IC) group, (n = 10). Specimens in the IC group were first tested with an 8 mm diameter IN with zero screws, followed by one and two screws (4.5 mm diameter) in the proximal and distal femur. A fracture model construct (FMC), (n = 14), consisting of a transverse femoral osteotomy with a 3 mm gap, was used with either 6 mm or 8 mm IN. In the 6 mm FMC, one and two 3.5 mm screws were used sequentially in the proximal and distal femoral segment. In the 8 mm FMC, one and two 3.5 mm screws and one and two 4.5 diameter screws were used similarly. When bending forces were applied parallel to IN screw holes, mean IN stiffness was 20% less than with forces perpendicular to the holes (n = 18), (P < .05). Eight-millimeter IN were 220% stiffer in torsion and 270% stiffer in bending than 6 mm IN (P < .05). Six-millimeter IN had approximately 32% of the bending stiffness and torsional stiffness of intact femurs (P < .05). Eight-millimeter IN had 93% and 79% of the bending stiffness and torsional stiffness, respectively, of intact femurs. Intact femur constructs (8 mm IN with four, 4.5 mm screws) had 147% of the bending stiffness (P < .05), and similar torsional stiffness and maximum torque, as intact femora (P > .05). The mean values of 6 mm FMC with four screws (3.5 mm) were 21% and 33% in torsional stiffness and bending stiffness, respectively, of intact femora values. When tested in torsion, 8 mm FMC failed by bone fracture; 6 mm FMC, in contrast, underwent plastic deformation. In comparing FMC stabilized with an 8 mm IN with two screws (4.5 mm diameter) in each bone segment, to intact femurs, the maximum torque was similar, FMC torsional stiffness was 40% (P < .05), and FMC bending stiffness was 65% (P < .05). These 8 mm FMC percentages are comparable to human IN fracture model construct values, indicating that the 8 mm IN/four screw construct should provide adequate stabilization for many canine diaphyseal femoral fractures.

Animals↗

An in vitro biomechanical comparison of an interlocking nail system and dynamic compression plate fixation of ostectomized equine third metacarpal bones.

OBJECTIVE: To compare the mechanical properties of two stabilization methods for ostectomized equine third metacarpi (MC3): (1) an interlocking nail system and (2) two dynamic compression plates. Animal or Sample Population-Ten pairs of adult equine forelimbs intact from the midradius distally. METHODS: Ten pairs of equine MC3 were divided into two test groups (five pairs each): caudocranial four-point bending and torsion. Interlocking nails (6 hole, 13-mm diameter, 230-mm length) were placed in one randomly selected bone from each pair. Two dynamic compression plates one dorsally (12 hole, 4.5-mm broad) and one laterally (10 hole, 4.5-mm broad) were attached to the contralateral bone from each pair. All bones had 1 cm mid-diaphyseal ostectomies. Five construct pairs were tested in caudocranial four-point bending to determine stiffness and failure properties. The remaining five construct pairs were tested in torsion to determine torsional stiffness and yield load. Mean values for each fixation method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: Mean (+/-SEM) values for the MC3-interlocking nail composite and the MC3-double plate composite, respectively, in four-point bending were: composite rigidity, 3,454+/-407.6 Nm/rad and 3,831+/-436.5 Nm/rad; yield bending moment, 276.4+/-40.17 Nm and 433.75+/-83.99 Nm; failure bending moment, 526.3+/-105.9 Nm and 636.2+/-27.77 Nm. There was no significant difference in the biomechanical values for bending between the two fixation methods. In torsion, mean (+/-SEM) values for the MC3-interlocking nail composite and the MC3-double plate composite were: composite rigidity, 124.1+/-16.61 Nm/rad and 262.4+/-30.51 Nm/rad; gap stiffness, 222.3+/-47.32 Nm/rad and 1,557+/-320.9 Nm/rad; yield load, 94.77+/-7.822 Nm and 130.66+/-20.27 Nm, respectively. Composite rigidity, gap stiffness, and yield load for double plate fixation were significantly higher compared with interlocking nail fixation in torsion. CONCLUSIONS: No significant differences in biomechanical properties were identified between an interlocking nail and double plating techniques for stabilization of ostectomized equine MC3 in caudocranial four-point bending. Double plating fixation was superior to interlocking nail fixation in torsion.

Animals↗

The effect of in situ freezing on rabbit patellar tendon. A histologic, biochemical, and biomechanical analysis.

Cell necrosis has been well documented as one of the many changes that occur in autogenous tendon when it is used to reconstruct the anterior cruciate ligament. The purpose of this experiment was to isolate cell necrosis as a variable and study its effect on the patellar tendon. To accomplish this, both knees of 25 New Zealand White rabbits were operated on. In one knee, a 5-mm wide band of patellar tendon was subjected to two rapid freeze-thaw cycles, while the other knee underwent sham surgery. Histologic evaluation showed a zone of necrosis at 2 and 4 weeks with cellular repopulation complete at 8 weeks. patellar tendon cross-sectional area was 0.118 cm2 at 8 weeks for the frozen specimens compared to 0.102 cm2 for the sham-operated controls. This difference was significant at the P = 0.025 level. Mechanical testing at 4 and 8 weeks revealed no significant changes in tendon length, maximum load, or stiffness. The collagen content was also unchanged at both 4 and 8 weeks.

Animals↗

Anterior cruciate ligament reconstruction with patellar tendon. An ex vivo study of wear-related damage and failure at the femoral tunnel.

Patellar tendon grafts used in the reconstruction of the anterior cruciate ligament may be subjected to thousands of knee flexion-extension cycles during the early postoperative period. The purpose of this study was to model experimentally the patellar tendon graft wear-related damage and failure at the femoral tunnel during simulated knee motion of 0 degrees to 112 degrees of flexion at 1 cycle/sec. To evaluate the effects of 2 different femoral tunnel orientations, tunnel chamfering, and 3 different graft loads on graft survival, 25 calf femurs and patellar tendons were used. All 5 specimens with a "straight-line" femoral tunnel and an applied load of 5 pounds (22.3 N) survived greater than 125,000 cycles. All 5 of the 5-pound unchamfered transverse tunnel grafts failed at an average of 19,869 cycles, but chamfering transverse tunnels resulted in the survival of 4 of 5 specimens. Decreasing the load to 2 pounds (8.9 N) for transverse unchamfered tunnels increased survival to 1 of 5, and cycles to failure to 75,132. If patellar tendon grafts used to reconstruct the anterior cruciate ligament are subjected to large numbers of flexion-extension cycles, the risk of wear-related damage and early failure may be decreased by straight-line femoral tunnel orientation, by chamfering of more transverse tunnels, or by avoiding large graft preloads.

Animals↗

Hyperbaric oxygen in the treatment of acute muscle stretch injuries. Results in an animal model.

Hyperbaric oxygen therapy is an established therapy in several areas of clinical medicine. However, studies have produced conflicting results regarding its efficacy for sports-related soft tissue injuries. This study examines the use of hyperbaric oxygen therapy after an acute muscle stretch injury in an animal model. Two groups of rabbits (nine in each group) were subjected to a partial stretch injury to the tibialis anterior muscle-tendon unit. For all 18 animals, the injuries were induced in the left limb, and the uninjured right limb served as a sham-operated control. In group 1, the animals were exposed to hyperbaric oxygen (> 95% O2 at 2.5 atm) for 60 minutes daily for 5 days. Treatment began 24 hours after injury. Group 2 animals were not exposed to hyperbaric oxygen. Evaluation 7 days after injury demonstrated a functional deficit (percent ankle isometric torque; injured side versus uninjured side) of 14.9% +/- 5.5% (mean +/- SD) for the treated group and 47.5% +/- 5.4% for the untreated group, representing a statistical difference using the Behrens-Fisher version of the t test (P = 0.001). Morphologic studies revealed more complete healing in the treated group. This study suggests that hyperbaric oxygen therapy may play a role in accelerating recovery after acute muscle stretch injury. Further studies are needed before definitive conclusions and treatment recommendations can be made.

Animals↗

Monopolar radiofrequency energy effects on joint capsular tissue: potential treatment for joint instability. An in vivo mechanical, morphological, and biochemical study using an ovine model.

The purpose of this study was to evaluate the thermal effect of monopolar radiofrequency energy, a potential treatment means for joint instability, on the mechanical, morphologic, and biochemical properties of joint capsular tissue in an in vivo ovine model. The energy was applied arthroscopically to the synovial surface of the femoropatellar joint capsule of 24 sheep. The sheep were sacrificed at 0, 2, 6, and 12 weeks after surgery (6 per group). Monopolar radiofrequency energy initially caused a significant decrease in tissue stiffness and an increase in tissue relaxation properties, followed by gradual improvement in the tissue's mechanical properties by 6 weeks after surgery. Microscopic examination illustrated that radiofrequency energy initially caused collagen hyalinization and cell necrosis, followed by active tissue repair. Biochemical analysis revealed that treated collagen was significantly more trypsin-susceptibile than untreated collagen at 0 and 2 weeks after surgery, indicating early collagen denaturation. This study demonstrated that this treatment initially caused a significantly deleterious effect on the mechanical properties of the joint capsule, which was associated with partial denaturation of joint capsular tissue. This was followed by gradual improvement of the mechanical, morphologic, and biochemical properties of the tissue over time.

Animals↗

Temperature-dependent versus constant-rate blood perfusion modelling in ferromagnetic thermoseed hyperthermia: results with a model of the human prostate.

Finite-element solutions to the Pennes bioheat equation are obtained with a model of a tumour-containing, human prostate and surrounding normal tissues. Simulations of ferromagnetic hyperthermia treatments are conducted on the tissue model in which the prostate is implanted with an irregularly spaced array of thermoseeds. Several combinations of thermoseed temperatures with different Curie points are investigated. Non-uniform, constant-rate blood perfusion models are studied and compared with temperature-dependent descriptions of blood perfusion. Blood perfusions in the temperature-dependent models initially increase with tissue temperature and then decrease at higher temperatures. Simulations with temperature-dependent versus constant-rate blood perfusion models reveal significant differences in temperature distributions in and surrounding the tumour-containing prostate. Results from the simulations include differences (between temperature-dependent and constant-rate models) in (1) the percentage of normal tissue volume and tumour volume at temperatures > 42 degrees C, and (2) temperature descriptors in the tumour (subscript t) and normal (subscript n) tissues including Tmax.t, Tmin.t and Tmax.n. Isotherms and grey-scale contours in the tumour and surrounding normal tissues are presented for four simulations that model a combination of high-temperature thermoseeds. Several simulations show that Tmin.t is between 1.7 and 2.6 degrees C higher and Tmax.n is between 2.1 and 3.3 degrees C higher with a temperature-dependent versus a comparable constant-rate blood perfusion model. The same simulations reveal that the percentages of tumour volume at temperatures > 42 degrees C are between 0 and 68% higher with the temperature-dependent versus the constant-rate perfusion model over all seed combinations studied. In summary, a numerical method is presented which makes it possible to investigate temperature-dependent, continuous functions of blood perfusion in simulations of hyperthermia treatments. Simulations with this numerical method reveal that the use of constant-rate instead of temperature-dependent blood perfusion models can be a conservative approach in treatment planning of ferromagnetic hyperthermia.

Body Temperature Regulation↗

Cortical elasticity in aging rats with and without growth hormone treatments.

This study quantified the orthotropic elastic changes in cortical bone due to aging as well as determined any elastic changes after acute treatments of growth hormone (GH). Three groups of twenty rats represented three age groups of young adult (9 months), middle age (20 months), and old (31 months) rats. During a ten day period, half of the rats in each age group were given twice-daily doses of recombinant human GH while the remaining half were injected with a vehicle control (saline). The effects of aging and GH on the elastic characteristics of cortical bone were quantified via ultrasonic wave propagation. Propagation velocities of longitudinal and shear waves were measured through cubic cortical specimens from the posterior femoral diaphysis. Density was measured by Archimedes' technique. The normalized, orthotropic elastic properties of Young's moduli (Eii), shear moduli (Gij), and Poisson's ratios (Vij) were calculated and used to compare the groups (where i and j = 1, 2, or 3 reference the radial, circumferential, and longitudinal axes, respectively). Cortical elastic moduli consistently increased with age with the strongest effects demonstrated in radial dependent properties such as E11 (+ 25.3% from 9 to 31 months, p = 0.0004) and G12 (+ 12.6% from 20 to 31 months, p = 0.0419). The ratio of transverse to axial displacement (Poisson's ratio) typically decreased with age (9 to 31 months) as seen in V31 (-24.95%, p = 0.0134) and V32 (-20.7%, p = 0.0015). Overall, a ten day treatment with GH produced no global statistical change in elastic properties (p > 0.05). However, GH did minimize the age related differences that were measured for E22, E33, and V32 between the 9 and 31 month old groups essentially returning old bone to its youthful elastic state. These finding add orthotropic detail to the current understanding of changing cortical elastic properties during aging as well as providing a reference for further studies of GH.

Aging↗