Search PubMed⌕ Search

Biomedical subjects

R V Shannon

Publications and source records attributed to R V Shannon.

At least 37 records · Page 2Linked to original sources

Accessing the tonotopic organization of the ventral cochlear nucleus by intranuclear microstimulation.

This study is part of a program to develop an auditory prosthesis for the profoundly deaf, based on multichannel microstimulation in the cochlear nucleus. The functionality of such a device is dependent on its ability to access the tonotopic axis of the human ventral cochlear nucleus in an orderly fashion. In these studies, we utilized the homologies between the human and feline ventral cochlear nuclei and the known tonotopic organization of the central nucleus of the inferior colliculus (IC). In anesthetized cats, stimuli were delivered to three or four locations along the dorsal-to-ventral axis of the posteroventral cochlear nucleus (PVCN), and for each stimulus location, we recorded the multiunit neuronal activity and the field potentials at 20 or more locations along the dorsolateral-ventromedial (tonotopic) axis of the IC. The current source-sink density (CSD), which delimits regions of neuronal activity, was computed from the sequence of field potentials recorded along this axis. The multiunit activity and the CSD analysis both showed that the tonotopic organization of the PVCN can be accessed in an orderly manner by intranuclear microstimulation in several regions of the PVCN, using the range of stimulus pulse amplitudes that have been shown in previous studies to be noninjurious during prolonged intranuclear microstimulation via chronically implanted microelectrodes. We discuss the applicability of these findings to the design of clinical auditory prostheses for implantation into the human cochlear nucleus.

Action Potentials↗

Within-channel gap detection using dissimilar markers in cochlear implant listeners.

Temporal gap detection thresholds were measured between perceptually dissimilar electrical markers in cochlear implant listeners. Both markers were presented to the same electrode pair. The amplitude and pulse rate of the first marker were fixed, and gap thresholds were measured as a function of either the pulse rate or the amplitude of the second marker. In either case, U-shaped functions were obtained, with lowest gap thresholds occurring when the two markers were similar in both amplitude and pulse rate. Because the two markers were presented to the same electrode pair, the data cannot be accounted for on the basis of across-channel interactions. It is hypothesized that when different markers are used, the perceptual discontinuity from the first marker to the second is similar to the sensation of a brief gap, and dominates the gap detection process. Thus, gap threshold functions with electrically dissimilar markers serve more as indicators of perceptual distance between the markers and less as measures of temporal resolution.

Auditory Threshold↗

Forward masked excitation patterns in multielectrode electrical stimulation.

Across-channel interactions in multi-electrode cochlear implant patients may be critical to their performance in the natural auditory environment. One measure of channel interaction can be obtained using forward masking. The patterns of threshold shift were obtained as a function of the separation between masker and probe electrode pairs in four Nucleus-implanted patients with varying levels of speech recognition. In the three subjects with better speech recognition (N4, N7, and N13), the masking patterns showed the least parameter dependence. In the subject with the lowest speech scores (N3), the masking patterns showed the greatest dependence on masker level and on probe delay. Masking as a function of masker level also reflected these differences: N3's functions showed the greatest changes for different probe delays. Similar rates of recovery were observed in the three good performers (time constant approximately 70 ms). In contrast, subject N3's recovery function shows a more rapid recovery. These data indicate that channel interaction is individually variable and parameter dependent, both of which may play a role in the perception of dynamic stimuli in the natural auditory environment.

Auditory Threshold↗

Importance of tonal envelope cues in Chinese speech recognition.

Recent studies have shown that temporal waveform envelope cues can provide significant information for English speech recognition. This study investigated the use of temporal envelope cues in a tonal language: Mandarin Chinese. In this study, the speech was divided into several frequency analysis bands; the amplitude envelope was extracted from each band by half-wave rectification and low-pass filtering and was used to modulate a noise of the same bandwidth as the analysis band. These manipulations preserved temporal and amplitude cues in each frequency band, but removed the spectral detail within each band. Chinese vowels, consonants, tones and sentences were identified by 12 native Chinese-speaking listeners with 1, 2, 3, and 4 noise bands. The results showed that the recognition score of vowels, consonants, and sentences increased monotonically with the number of bands, a pattern similar to that observed in English speech recognition. In contrast, tones were consistently recognized at about 80% correct level, independent of the number of bands. This high level of tone recognition produced a significant difference in the open-set sentence recognition between Chinese (11.0%) and English (2.9%) for the one-band condition where no spectral information was available. The data also revealed that, with primarily temporal cues, the falling-rising tone (tone 3) and the falling tone (tone 4) were more easily recognized than the flat tone (tone 1) and the rising tone (tone 2). This differential pattern in tone recognition resulted in a similar pattern in word recognition: words having either tone 3 or 4 were more likely to be recognized while words having tone 1 and 2 were not. The quantitative role of tones in Chinese speech recognition was further explored using a power-function model and found to play a significant role in relating phoneme recognition to sentence recognition.

Adult↗

Gap detection as a measure of electrode interaction in cochlear implants.

Gap detection thresholds were measured as an indication of the amount of interaction between electrodes in a cochlear implant. The hypothesis in this study was as follows: when the two stimuli that bound the gap stimulate the same electrode, and thus the same neural population, the gap detection threshold will be short. As two stimuli are presented to two electrodes that are more widely separated, the amount of neural overlap of the two stimuli decreases, the stimuli sound more dissimilar, and the gap thresholds increase. Gap detection thresholds can thus be used to infer the amount of overlap in neural populations stimulated by two electrodes. Three users of the Nucleus cochlear implant participated in this study. Gap detection thresholds were measured as a function of the distance between the two electrode pairs and as a function of the spacing between the two electrodes of a bipolar pair (i.e., using different modes of stimulation). The results indicate that measuring gap detection thresholds may provide an estimate of the amount of electrode interaction. Gap detection thresholds were a function of the physical separation of the electrode pairs used for the two stimuli that bound the gap. Lower gap thresholds were observed when the two electrode pairs were closely spaced, and gap thresholds increased as the separation increased, resulting in a "psychophysical tuning curve" as a function of electrode separation. The sharpness of tuning varied across subjects, and for the three subjects in this study, the tuning was generally sharper for the subjects with better speech recognition. The data also indicate that increasing the separation between active and reference electrodes has limited effect on spatial selectivity (or tuning) as measured perceptually.

Acoustic Stimulation↗

Speech recognition with altered spectral distribution of envelope cues.

Recognition of consonants, vowels, and sentences was measured in conditions of reduced spectral resolution and distorted spectral distribution of temporal envelope cues. Speech materials were processed through four bandpass filters (analysis bands), half-wave rectified, and low-pass filtered to extract the temporal envelope from each band. The envelope from each speech band modulated a band-limited noise (carrier bands). Analysis and carrier bands were manipulated independently to alter the spectral distribution of envelope cues. Experiment I demonstrated that the location of the cutoff frequencies defining the bands was not a critical parameter for speech recognition, as long as the analysis and carrier bands were matched in frequency extent. Experiment II demonstrated a dramatic decrease in performance when the analysis and carrier bands did not match in frequency extent, which resulted in a warping of the spectral distribution of envelope cues. Experiment III demonstrated a large decrease in performance when the carrier bands were shifted in frequency, mimicking the basal position of electrodes in a cochlear implant. And experiment IV showed a relatively minor effect of the overlap in the noise carrier bands, simulating the overlap in neural populations responding to adjacent electrodes in a cochlear implant. Overall, these results show that, for four bands, the frequency alignment of the analysis bands and carrier bands is critical for good performance, while the exact frequency divisions and overlap in carrier bands are not as critical.

Adult↗

Effects of amplitude nonlinearity on phoneme recognition by cochlear implant users and normal-hearing listeners.

It is widely assumed that the proper transformation of acoustic amplitude to electric amplitude is a critical factor affecting speech recognition in cochlear implant users and normal-hearing listeners. A four-channel noise-band speech processor was implemented, reducing spectral information to four bands. A power-law transformation was applied to the amplitude mapping stage in the speech processor design, and the exponent of the power function varied from a strongly compressive (p = 0.05) to a weakly compressive (p = 0.75) for implant listeners and from 0.3 to 3.0 for acoustic listeners. Results for implants showed that the best performance was achieved with an exponent of about 0.2, and performance gradually deteriorated when either more compressive or less compressive exponents were applied. The loudness growth functions of the four activated electrodes in each subject were measured and those data were well fit by a power function with a mean exponent of 2.72. The results indicated that the best performance was achieved when the normal loudness growth was restored. For acoustic listeners, results were similar to those observed with cochlear implant listeners, except that best performance was achieved with no amplitude nonlinearity (p = 1.0). The similarity of results in both acoustic and electric stimulation indicated that the performance deterioration observed for extreme nonlinearity was due to similar perceptual effects. The function relating amplitude mapping exponent and performance was relatively flat, indicating that phoneme recognition was only mildly affected by amplitude nonlinearity.

Adult↗

Effects of noise and spectral resolution on vowel and consonant recognition: acoustic and electric hearing.

Current multichannel cochlear implant devices provide high levels of speech performance in quiet. However, performance deteriorates rapidly with increasing levels of background noise. The goal of this study was to investigate whether the noise susceptibility of cochlear implant users is primarily due to the loss of fine spectral information. Recognition of vowels and consonants was measured as a function of signal-to-noise ratio in four normal-hearing listeners in conditions simulating cochlear implants with both CIS and SPEAK-like strategies. Six conditions were evaluated: 3-, 4-, 8-, and 16-band processors (CIS-like), a 6/20 band processor (SPEAK-like), and unprocessed speech. Recognition scores for vowels and consonants decreased as the S/N level worsened in all conditions, as expected. Phoneme recognition threshold (PRT) was defined as the S/N at which the recognition score fell to 50% of its level in quiet. The unprocessed speech had the best PRT, which worsened as the number of bands decreased. Recognition of vowels and consonants was further measured in three Nucleus-22 cochlear implant users using either their normal SPEAK speech processor or a custom processor with a four-channel CIS strategy. The best cochlear implant user showed similar performance with the CIS strategy in quiet and in noise to that of normal-hearing listeners when listening to correspondingly spectrally degraded speech. These findings suggest that the noise susceptibility of cochlear implant users is at least partly due to the loss of spectral resolution. Efforts to improve the effective number of spectral information channels should improve implant performance in noise.

Adult↗

Multi-unit mapping of acoustic stimuli in gerbil inferior colliculus.

Multi-unit peristimulus time (MU-PST) histograms were recorded in the gerbil inferior colliculus (IC) in response to tone burst stimuli. Histograms were collected every 100 microns as the recording electrode was advanced along the tonotopic axis of the central nucleus of the IC. Space/time maps of neural activity were constructed from these data. In most of our sample the pattern of response changed systematically as the stimulating frequency was increased in octave steps. At low frequencies (< 500 Hz) the pattern of response was broadly distributed spatially and phase-locked to the stimulus frequency. At higher frequencies (> 1 kHz) the pattern of response was more localized and showed no evidence of phase locking. The location of the maximum response to tones from 1 to 32 kHz moved ventrally along the tonotopic axis at an approximate rate of 230 microns/stimulus octave. The patterns of response were localized near stimulus threshold and spread over a larger region as level increased. This method of collecting and displaying multi-unit response maps provides an overview of ensemble activity that allows concurrent observation of spatial and temporal variations in activity patterns. The quantitative analysis of components of MU-PST Maps are consistent with trends illustrated with single-unit tuning and level functions. This perspective of IC activity suggests potential processing mechanisms that are congruent with single-unit reconstructions.

Acoustic Stimulation↗

Speech recognition as a function of the number of electrodes used in the SPEAK cochlear implant speech processor.

Speech recognition was measured in listeners with the Nucleus-22 SPEAK speech processing strategy as a function of the number of electrodes. Speech stimuli were analyzed into 20 frequency bands and processed according to the usual SPEAK processing strategy. In the normal clinical processor each electrode is assigned to represent the output of one filter. To create reduced-electrode processors the output of several adjacent filters were directed to a single electrode, resulting in processors with 1, 2, 4, 7, 10, and 20 electrodes. The overall spectral bandwidth was preserved, but the number of active electrodes was progressively reduced. After a 2-day period of adjustment to each processor, speech recognition performance was measured on medial consonants, vowels, monosyllabic words, and sentences. Performance with a single electrode processor was poor in all listeners, and average performance increased dramatically on all test materials as the number of electrodes was increased from 1 to 4. No differences in average performance were observed on any test in the 7-, 10-, and 20-electrode conditions. On sentence and consonant tests there was no difference between average performance with the 4-electrode and 20-electrode processors. This pattern of results suggests that cochlear implant listeners are not able to make full use of the spectral information on all 20 electrodes. Further research is necessary to understand the reasons for this limitation and to understand how to increase the amount of spectral information in speech received by implanted listeners.

Adolescent↗

Threshold-distance measures from electrical stimulation of human brainstem.

Threshold current levels for electrical stimulation of a single human brainstem via an auditory prosthesis are compared with postmortem measures of the distance between the electrode and stimulated structures. The results compare well with the summary of threshold-distance measures from animal experiments compiled by Ranck. The correspondence between the human and animal data gives confidence that the extent of current spread (distance to stimulable neural units) can be well estimated from the current level at threshold for 200 microseconds/phase biphasic pulses. This is of particular interest in electrical stimulation of the human central nervous system, where localization of stimulation is of paramount importance.

Animals↗

Place pitch discrimination and speech recognition in cochlear implant users.

The considerable variability in speech perception performance among cochlear implant patients makes it difficult to compare the effectiveness of different speech processing strategies. One result is that optimal individualized processor parameter setting is not always achieved. This paper investigates the relationship between place pitch discrimination ability and speech perception to establish whether pitch ranking could be used as an aid in better patient-specific fitting of processors. Three subjects participated in this study. Place pitch discrimination ability was measured and this information was used to design new channel to electrode allocations for each subject. Several allocations were evaluated with speech tests with consonant, vowel and sentence material. It is shown that there is correlation between the perceptual pitch distance between electrodes and speech perception performance. The results indicate that pitch ranking ability might be used both as an indicator of the speech perception potential of an implant user and in the choice of better electrode configurations.

Adult↗

Speech recognition with primarily temporal cues.

Nearly perfect speech recognition was observed under conditions of greatly reduced spectral information. Temporal envelopes of speech were extracted from broad frequency bands and were used to modulate noises of the same bandwidths. This manipulation preserved temporal envelope cues in each band but restricted the listener to severely degraded information on the distribution of spectral energy. The identification of consonants, vowels, and words in simple sentences improved markedly as the number of bands increased; high speech recognition performance was obtained with only three bands of modulated noise. Thus, the presentation of a dynamic temporal pattern in only a few broad spectral regions is sufficient for the recognition of speech.

Auditory Threshold↗

Possible origins of the non-monotonic intensity discrimination function in forward masking.

A non-monotonic intensity discrimination function in forward masking has been recently reported [Zeng et al. (1991) Hear. Res. 55, 223-230; Zeng and Turner (1992) J. Acoust Soc. Am. 92, 782-787] in which just-noticeable-differences (jnds) in intensity are largest for midlevel tones and smaller for soft and loud tones following an intense narrow-band noise. One hypothesis was that this midlevel hump reflects the contribution of low-spontaneous rate (SR) neurons to intensity coding, based on the differential recovery from forward masking of low-SR and high-SR neurons [Relkin and Doucet (1991) Hear. Res. 55, 215-222]. The present study conducted three experiments stimulating different stages of the auditory system in an attempt to determine the peripheral and central origins of the midlevel hump. First, in two cochlear implant (CI) listeners, the forward masker produced a midlevel hump on the intensity discrimination function, suggesting that the synapses between the hair cell and the eighth nerve are probably not responsible for the hump, as they are bypassed and the eighth nerve is stimulated directly. Second, in auditory brainstem implant (ABI) listeners, the forward masker produced no midlevel hump, but the masked jnds were larger than those without a masker. The absence of the midlevel hump in the ABI listeners suggests that the occurrence of the hump requires physiological mechanisms in the auditory nerve transmission, or the intrinsic processing circuits of the cochlear nuclei, or both. Third, in normal-hearing listeners, an ipsilateral, 90 dB SPL, pure-tone forward masker produced a midlevel hump, which is similar to that using a narrow-band noise masker; whereas a contralateral forward masker produced essentially no midlevel hump, suggesting that binaural interactions at superior olivary complex and more central sites are probably not responsible.

Acoustic Stimulation↗

Loudness of simple and complex stimuli in electric hearing.

In a earlier study we showed that loudness function depends on stimulus frequency for simple sinusoidal and pulsatile stimuli in cochlear implants. Loudness is an exponential function of stimulus amplitude for high frequencies (> 300 Hz) and a power function for low frequencies (< 300 Hz). Two experiments were conducted to extend our previous work in eight Ineraid cochlear implant subjects. First, loudness functions were measured by means of a magnitude estimation technique for simple sinusoidal stimuli. Stimuli were 100- and 1,000-Hz sinusoids. Stimuli had a duration of 300 milliseconds and were presented at amplitudes representing 10%, 30%, 50%, 70%, and 90% of the dynamic range. Loudness estimates were best fit by an exponential function for the 1,000-Hz sinusoid and by a power function for the 100-Hz sinusoid. The estimation result is consistent with previous results that were obtained with a loudness balance technique. In a second experiment, loudness functions were studied for modulated stimuli, in which a 1,000-Hz sinusoid was modulated by a 100-Hz sinusoid at either 50% or 100% modulation depth. A linear loudness-balance function was obtained between the modulated stimuli and a 1,000-Hz sinusoidal standard, indicating that the modulated stimuli have the same exponential loudness function as the 1,000-Hz carrier despite the 100-Hz modulator. This result has important implications for speech processor design, because many devices use low-frequency speech envelopes to modulate a high-frequency carrier. This result also provides a psychophysical basis for the logarithmic amplitude transformation in commonly used speech processors to compress the wide acoustic dynamic range into a narrow electric dynamic range while preserving normal loudness function.

Adult↗

Loudness-coding mechanisms inferred from electric stimulation of the human auditory system.

Two distinct physiological mechanisms underlying loudness sensation were inferred from electric stimulation of the human auditory nerve and brainstem. In contrast to a power function relating loudness and stimulus intensity in acoustic hearing, loudness in electric stimulation of the auditory nerve depends on stimulus frequency. Loudness is an exponential function of electric amplitude for high frequencies and is a power function for low frequencies. A frequency-dependent, two-stage model is suggested to explain the loudness function, in which the first stage of processing is performed by a mechanical mechanism in the cochlea for high-frequency stimuli and by a neural mechanism in the cochlear nucleus for low-frequency stimuli.

Acoustic Stimulation↗

Quantitative comparison of electrically and acoustically evoked auditory perception: implications for the location of perceptual mechanisms.

Electrical stimulation of the human auditory system produces different patterns of spatial and temporal neural activity than those that occur in the normal, acoustically stimulated system. Quantitative comparison of psychophysical performance measured with acoustic and electrical stimulation may allow us to infer the physiological locus of perceptual mechanisms. In this paper we compare psychophysical data on temporal resolution from normal-hearing listeners, cochlear implant listeners, and patients electrically stimulated on the cochlear nucleus. Measures of gap detection, forward masking, and modulation detection will be compared. These comparisons demonstrate that temporal processing is relatively similar across these three groups once the obvious differences in dynamic range are taken into consideration. In addition, preliminary results with speech processors indicate that implant patients can utilize all temporal information in speech. Thus, implant patients have relatively normal temporal resolution and can integrate temporal cues normally for the recognition of complex acoustic patterns such as speech. These results imply that the central auditory systems of implant patients are able to fully utilize the non-natural patterns of temporal neural information produced by electrical stimulation. The differences in the microstructure of the neural pattern (phase locking, stochastic independence of fibers, spatial distribution of activity, etc.) between electrical and acoustic stimulation are apparently not necessary for temporal processing. Thus, the physiological locus of temporal processing mechanisms must be more central in the auditory system than the cochlea and cochlear nucleus.

Acoustic Stimulation↗