Search PubMed⌕ Search

Biomedical subjects

R V Patel

Publications and source records attributed to R V Patel.

At least 37 records · Page 2Linked to original sources

Estimation of total body and extracellular water in post-coronary artery bypass graft surgical patients using single and multiple frequency bioimpedance.

OBJECTIVE: To assess the value of bioimpedance as a clinical tool by determining the accuracy and bias of single and multiple frequency bioimpedance estimates of total body and extracellular water in comparison with values established by criterion reference techniques. DESIGN: Controlled, prospective, single-blind investigation. SETTING: Private, not-for-profit, university-affiliated, acute care hospital. PATIENTS: Eight male, post-elective coronary artery bypass graft surgical patients. INTERVENTIONS: Within 6 hrs after surgery, estimates of total body and extracellular water volumes were determined using single and multiple frequency bioimpedance techniques. These estimates were then compared with the gold standard volumes measured by deuterium oxide and bromine dilutional space determination, respectively. MEASUREMENTS AND MAIN RESULTS: The mean multiple frequency bioimpedance estimate of total body water of 47.7 +/- 9.4 L was statistically different from the single frequency bioimpedance and deuterium values of 52.5 +/- 9.4 (p < .006) and 53.3 +/- 11.6 L (p < .002), respectively. In comparison, the mean multiple and single frequency bioimpedance estimates of extracellular water, 26.3 +/- 5.4 and 29.2 +/- 5.4 L, respectively, were not statistically different from the bromine value of 27.5 +/- 6.9 L. In addition, the mean errors for multiple and single frequency bioimpedance determinations of extracellular water, -1.2 +/- 2.0 and 1.7 +/- 2.7 L, respectively, were statistically different (p = .001). CONCLUSIONS: In male, post-elective coronary artery bypass graft surgical patients, single frequency bioimpedance was a more accurate and less biased predictor of total body water than multiple frequency bioimpedance. The accuracy and bias of multiple frequency bioimpedance was superior to single frequency bioimpedance for the prediction of extracellular water. Whether this observation remains true for other populations of critically ill patients remains to be investigated.

Aged↗

Effects of ramipril and enalapril on cerebral blood flow in elderly patients with asymptomatic carotid artery occlusive disease.

We wished to determine in asymptomatic hypertensive patients with > or = 70% stenosis of an internal carotid artery the change in regional cerebral blood flow (rCBF) produced by ramipril and enalapril and to evaluate the influence of age on drug-induced changes in rCBF. In a prospective, randomized, single-blind, placebo-controlled investigation, using the 133Xenon inhalation technique, we assessed baseline rCBF in 15 patients (9 men and 6 women aged 60-79 years) after a 24-h antihypertensive drug-free period. All patients then received a single 5-mg oral dose of ramipril, enalapril, or placebo. rCBF was reassessed 2 h postdose. There was no significant change in the median rCBF in any of the three treatment groups. Neither did we observe any lateralization of BF to any specific cerebral region in any of the three groups. There were no observed or patient-reported adverse events (AE). Single 5-mg oral doses of either ramipril or enalapril did not decrease CBF significantly in asymptomatic hypertensive patients with > or = 70% stenosis of an internal carotid artery and are probably safe starting doses in such patients. In addition, this effect was not modified by age.

Age Factors↗

Vancomycin removal by high-flux polysulfone hemodialysis membranes in critically ill patients with end-stage renal disease.

To define the pharmacokinetics of vancomycin in patients undergoing maintenance hemodialysis in an acute care setting and to characterize the rebound phenomenon occurring after hemodialysis, vancomycin t1/2 during the interdialytic and intradialytic phases and intradialytic clearance were measured in eight critically ill patients undergoing high-flux hemodialysis using F-80 or F-60 polysulfone dialyzers. Intradialytic clearance was determined using the recovery method. In patients dialyzed with F-80 dialyzers, interdialytic and intradialytic t1/2 for vancomycin were 162 +/- 69.8 hours and 4.7 +/- 1.3 hours, respectively. Intradialytic clearance was 108.5 +/- 16.3 mL/min, and 238 +/- 55 mg of vancomycin was recovered in the dialysate. In patients dialyzed with F-60 dialyzers, interdialytic and intradialytic t1/2 were 211.0 +/- 166.8 and 4.6 +/- 0.4 hours, respectively. Intradialytic clearance was 100.6 +/- 18.3 mL/min and the amount of vancomycin recovered was 252 +/- 79 mg. Vancomycin concentrations rebounded by 16% to 37% between 3 and 6 hours in patients dialyzed with the F-80 dialyzer and 15% to 38% between 2 and 3 hours in patient dialyzed with F-60 dialyzers. Hemodialysis with high-flux polysulfone dialyzers removes significant amounts of vancomycin in patients dialyzed in an acute care setting. A suggested scheme for vancomycin dosage adjustments in these patients is presented.

Adult↗

Proarrhythmic effects of intravenous vasopressors.

OBJECTIVE: To review the electrophysiologic properties and the in vitro, ex vivo, animal, and human data regarding proarrhythmic effects of intravenous vasopressors. DATA SOURCES: A comprehensive (MEDLINE) search (1960-1994) was conducted for dopamine, epinephrine, norepinephrine, phenylephrine, and methoxamine. STUDY SELECTION: In vitro and ex vivo studies and investigations performed in animals or humans reporting electrophysiologic and/or proarrhythmic effects of the above intravenous vasopressors were selected. A comprehensive search of all human studies involving these agents was conducted to reveal any proarrhythmic effects that may have been reported. In addition, case reports of proarrhythmic effects associated with these agents were reviewed. DATA EXTRACTION: Data regarding electrophysiologic and proarrhythmic effects of these agents were extracted from in vitro, ex vivo, animal, and human studies. Because few studies with the specific purpose of investigating proarrhythmic effects of vasopressors have been performed in humans, all studies involving these drugs for evaluation of hemodynamic effects, clinical efficacy, or other endpoints in humans were reviewed. In addition, data were extracted from case reports of proarrhythmic effects associated with these agents. DATA SYNTHESIS: Dopamine increases automaticity in Purkinje fibers and has a biphasic effect on action-potential duration. Dopamine has caused both atrial and ventricular tachyarrhythmias in animals. Human data have revealed dose-related sinus tachycardia, with few reports of clinically significant ventricular arrhythmias. Epinephrine shortens sinus cycle length, increases atrial and ventricular automaticity, promotes atrioventricular nodal conduction, and decreases ventricular effective refractory period (ERP). It is well known to induce ventricular fibrillation and decrease the ventricular fibrillation threshold (VFT) in ex vivo models as well as intact animals. In humans, epinephrine may cause dose-related sinus tachycardia, supraventricular arrhythmias, or, more commonly, ventricular arrhythmias. Norepinephrine increases automaticity of the sinoatrial node, atria, and ventricles; promotes atrioventricular nodal conduction; and decreases ventricular ERP. In vitro/ex vivo and animal data have shown that norepinephrine significantly decreases VFT. Although electrophysiologic studies suggest that norepinephrine may be proarrhythmic, few supporting data exist in humans. Phenylephrine demonstrates differential electrophysiologic effects in atrial and ventricular tissue. Most data suggest that phenylephrine causes prolongation of the ventricular ERP. Rather than being proarrhythmic, phenylephrine may be protective against arrhythmias. The drug elevates VFT in dogs. In humans, phenylephrine effectively terminates supraventricular tachycardias and may be protective against ventricular arrhythmias. Like phenylephrine, methoxamine elevates the repetitive extrasystolic, atrial, and ventricular fibrillatory thresholds. Methoxamine also may have antiarrhythmic effects because of alpha-receptor stimulation and reflex vagal activity. Despite the relatively low risk of arrhythmogenicity associated with intravenous vasopressors, patients should be monitored for potential proarrhythmic effects and appropriate action taken as necessary. Critically ill patients often have concurrent conditions, electrolyte disturbances, and underlying arrhythmias that predispose them to a higher risk of vasopressor proarrhythmic effects. CONCLUSIONS: Controlled data supporting the proarrhythmic potential of intravenous vasopressors in humans are lacking. Sinus tachycardia, asymptomatic ventricular ectopic activity, and other ventricular or supraventricular arrhythmias have been reported in association with dopamine and epinephrine. Phenylephrine and methoxamine have been associated with sinus bradycardia, but otherwise may be antiarrhythmic. Intravenous vasopressors appear relatively safe w

Animals↗

Prophylaxis for stress-related gastric hemorrhage in the medical intensive care unit. A randomized, controlled, single-blind study.

OBJECTIVE: To determine the efficacy and safety of cimetidine and sucralfate prophylaxis for stress-related gastrointestinal hemorrhage in patients admitted to a medical intensive care unit. SETTING: Medical intensive care unit of a nonprofit, university-affiliated teaching hospital. PATIENTS: 300 patients admitted to the medical intensive care unit during a 10-month period. DESIGN: Randomized, controlled, single-blind clinical trial. INTERVENTION: Patients were assigned to receive no prophylaxis (control), 1 g sucralfate given orally every 6 hours, or continuous intravenous cimetidine titrated to maintain gastric pH at 4.0, intervention was maintained until the occurrence of clinically severe hemorrhage, onset of drug-related complications, death, or discharge from the medical intensive care unit. OUTCOME MEASURES: The primary outcome measure was the incidence of clinically severe hemorrhage from endoscopically verified stress-related gastritis. Other outcome measures were transfusion requirements, duration of medical intensive care unit stay, incidence of nosocomial pneumonia, adverse drug reactions, and death. RESULTS: 100 patients were randomly assigned to each treatment. The three groups were similar with regard to demographic characteristics, intensive care unit admission diagnoses, and APACHE II scores. Stress-related hemorrhage was seen in 6% of control participants and in 5% of those receiving sucralfate or cimetidine (relative risk compared with control, 0.83 for each group; 95% CI, 0.26 to 2.64; P = 0.75). No statistically significant differences were found for transfusion requirements, duration of medical intensive care unit stay, and mortality rates among the three groups. Nosocomial pneumonia was diagnosed in 6%, 12%, and 13% of controls, sucralfate recipients, and cimetidine recipients, respectively (sucralfate: relative risk, 2.0 [CI, 0.79 to 5.01], P = 0.14; cimetidine: relative risk, 2.2 [CI, 0.88 to 5.33], P = 0.09). Prophylaxis caused no definite adverse drug reactions. CONCLUSIONS: The observed effects of cimetidine and sucralfate on the incidence and severity of hemorrhage from stress-related gastritis were not significant when compared with no treatment. Routine prophylaxis with these agents for patients entering the medical intensive care unit does not seem warranted.

Adult↗

Estimation of total body and extracellular water using single- and multiple-frequency bioimpedance.

OBJECTIVE: To determine the precision and bias of single- and multiple-frequency bioimpedance estimates of total body water (TBW) and extracellular water (ECW) volumes in comparison with the true values for these volumes established by gold standard dilution techniques. DESIGN: Controlled, prospective, open-label investigation. SETTING: Private, not-for-profit university-affiliated, acute care hospital. PARTICIPANTS: Normal, healthy men (n = 8) and women (n = 6) volunteers, 25-46 years of age. INTERVENTIONS: A single oral dose of a mixture of deuterium oxide 10 g and bromine 30 mmol; bioimpedance analysis pre- and three hours postmixture administration. MAIN OUTCOME PARAMETERS: TBW and ECW volumes established by deuterium oxide and bromine dilutional spaces (gold standards), respectively, and single- and multiple-frequency bioimpedance estimates of those same volumes. RESULTS: The mean multiple-frequency bioimpedance (MFB) and single frequency bioimpedance (SFB) estimates of TBW, 41.2 and 42.1 L, respectively, were not statistically different (NS) from the 41.2 L deuterium oxide value. Although the two methods had similar precision (NS), MFB was less biased. For ECW, the mean MFB and SFB values of 19.5 and 24.8 L, respectively, were significantly different from the bromine value of 18.8 L (p = 0.013 and p = 0.001, respectively). MFB was the more precise and less biased predictor of ECW. CONCLUSIONS: Compared with SFB, the MFB approach is a more precise and less biased predictor of TBW and ECW volumes in young, healthy adults, and may offer more accurate assessment in subjects with aberrant physiology.

Adult↗

Labetalol: response and safety in critically ill hemorrhagic stroke patients.

OBJECTIVE: To observe and characterize the blood pressure (BP)-lowering and adverse hemodynamic and/or central nervous system effects of intravenous bolus doses of labetalol in hemorrhagic stroke patients. DESIGN: Observational, prospective, pilot survey conducted over an eight-week period. SETTING: Surgical intensive care unit. PARTICIPANTS: Patients admitted with an intracerebral or subarachnoid hemorrhage. MAIN OUTCOME PARAMETERS: Absolute decline in systolic BP (SBP) and diastolic BP (DBP), time to peak reduction in SBP and DBP, and adverse hemodynamic and mental status changes. RESULTS: Labetalol at doses between 5 and 25 mg lowered SBP by 6-19 percent (baseline 152-184 mm Hg) and DBP by 3-26 percent (baseline 50-99 mm Hg). Adverse hemodynamic or mental status changes were not detected following labetalol administration. CONCLUSIONS: Small (< or = 25 mg) intravenous bolus doses of labetalol produce mild decreases in BP in hemorrhagic stroke patients.

Adult↗