Search PubMed⌕ Search

Biomedical subjects

R V Mulkern

Publications and source records attributed to R V Mulkern.

At least 37 records · Page 2Linked to original sources

Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP).

A new parallel imaging technique was implemented which can result in reduced image acquisition times in MRI. MR data is acquired in parallel using an array of receiver coils and then reconstructed simultaneously with multiple processors. The method requires the initial estimation of the 2D sensitivity profile of each coil used in the receiver array. These sensitivity profiles are then used to partially encode the images of interest. A fraction of the total number of k-space lines is consequently acquired and used in a parallel reconstruction scheme, allowing for a substantial reduction in scanning and display times. This technique is in the family of parallel acquisition schemes such as simultaneous acquisition of spatial harmonics (SMASH) and sensitivity encoding (SENSE). It extends the use of the SMASH method to allow the placement of the receiver coil array around the object of interest, enabling imaging of any plane within the volume of interest. In addition, this technique permits the arbitrary choice of the set of k-space lines used in the reconstruction and lends itself to parallel reconstruction, hence allowing for real-time rendering. Simulated results with a 16-fold increase in temporal resolution are shown, as are experimental results with a 4-fold increase in temporal resolution. Magn Reson Med 44:301-308, 2000.

Brain↗

Line scan echo planar spectroscopic imaging.

A line scan echo planar spectroscopic imaging (LSEPSI) sequence is presented which can rapidly produce 2D chemical shift imaging (CSI) data with minimal relaxation weighting and motion-related artifacts. The technique is based on successive "snapshot" 1D CSI acquisitions of individual tissue columns, and avoids T(1) saturation problems associated with the short TR periods needed for very rapid scanning with either conventional or echo planar-based 2D CSI methods. Potential applications include rapid fat/water spectral quantitation in the abdomen and internally referenced temperature monitoring for interventional procedures.

Adult↗

Simultaneous measurements of temperature and pH in vivo using NMR in conjunction with TmDOTP5-.

NMR techniques for temperature and pH measurements have attracted increasing interest in recent years, motivated in part by the growing importance of medical hyperthermia for the treatment of cancer. The chemical shifts of thulium 1, 4, 7, 10-tetraazacyclododecane-1, 4, 7, 10-tetrakis(methylene phosphonate) (TmDOTP5-) have been studied as a function of temperature and pH. The results demonstrate that TmDOTP5- resonance shifts are highly sensitive to temperature (approximately 1.0 ppm/degrees C) and pH (approximately 3.2 ppm/pH unit) at clinically relevant field strengths. A new method is presented which utilizes two magnetically non-equivalent protons in TmDOTP5- for simultaneous NMR measurements of both temperature and pH. The difference in the chemical shift values of pairs of 1H resonances provides a temperature sensitivity of about 1.6 ppm/ degrees C. The technique is demonstrated in live rats undergoing ultrasound-induced hyperthermia therapy.

Animals↗

Magnetic resonance imaging measurements of bone density and cross-sectional geometry.

Magnetic resonance imaging (MRI) is commonly used in the assessment of the musculoskeletal system and associated pathology. The ability of MRI to measure the signals from water and lipid protons enables quantitative measurements of bone porosity. The goal of this investigation was to demonstrate that the density and cross-sectional geometry of whole bones can be noninvasively measured using MRI. Ten trabecular specimens cored from whale vertebrae were used to compare apparent bone density measured directly, and using a quantitative MRI algorithm. Bone density and several cross-sectional geometric properties were also measured using MRI in the distal tibia of 14 volunteers. The MRI measurements were compared with measurements made using quantitative-computed tomography (QCT). A proton density sequence was used for all MRI studies. A porosity phantom was included in the MRI examinations and used to convert the MRI signal intensity to bone volume fraction. Bone density and cross-sectional bone geometry were calculated from the bone volume fractions by assuming constant tissue properties. The apparent density of trabecular bone cores measured directly and using quantitative MRI were linearly related (r(2) = 0.959; P < 0. 01). A strong linear relation also existed between MRI and QCT measurements of ash density (r(2) = 0.923; P < 0.01) and cross-sectional geometric properties (r(2) = 0.976-0.992; P < 0.01). MRI data can be used to measure bone density and cross-sectional geometry of whole bones if a proton density sequence is used to homogenize differences in marrow composition and a porosity phantom is used for slice-specific volume fraction calibration.

Adult↗

Optimized single-slab three-dimensional spin-echo MR imaging of the brain.

The development and optimization of spin-echo-based, single-slab, three-dimensional techniques for magnetic resonance imaging of the whole brain are described. T1-weighted and T2-weighted image sets with a volume resolution of 1 mm(3) and fluid-attenuated inversion-recovery image sets with a volume resolution of 3 mm(3) were obtained in acquisition times of less than 10 minutes per image set.

Artifacts↗

Effect of chronic, low-pressure, sterile vesicoureteral reflux on renal growth and function in a porcine model: a radiologic and pathologic study.

PURPOSE: To study the effects of chronic, low-pressure, sterile vesicoureteral reflux (VUR) on renal growth and function in a porcine model. MATERIALS AND METHODS: Unilateral VUR was created in five pigs, with the contralateral kidney serving as a control. Preoperatively, and 1 year later, ultrasonography, technetium 99m-dimercaptosuccinic acid (DMSA) scintigraphy, contrast material-enhanced computed tomography (CT), and contrast-enhanced magnetic resonance (MR) imaging were performed. Morphologic abnormalities and relative uptake of (99m)Tc-DMSA were recorded. The postcontrast enhancement ratios for parenchymal regions of interest at CT and MR imaging were determined. Ruthenium 103-labeled microspheres were used to determine regional blood flow. After the pigs were sacrificed, the kidneys were excised, weighed, and analyzed pathologically. RESULTS: Two of five refluxing kidneys had less than 45% function at scintigraphy. One of these two kidneys was small at postmortem examination. There were no other imaging or gross pathologic abnormalities. There was no significant difference in regional blood flow between the refluxing and nonrefluxing kidneys. In all of the operated on kidneys, histologic examination showed focal chronic inflammation and fibrosis. CONCLUSION: Low-pressure sterile reflux into previously normal kidneys led to mild, focal, chronic interstitial inflammation and fibrosis after 1 year. Imaging findings were normal apart from a subtle decrease in tubular function in two refluxing kidneys.

Animals↗

MR line-scan diffusion imaging of the spinal cord in children.

Diffusion imaging has been widely used in the brain, but its application in the spinal cord has been limited. Using line-scan diffusion imaging (LSDI), a technique that is less sensitive to magnetic susceptibility and motion artifacts than are other diffusion techniques, we have successfully imaged the spinal cord in children. The apparent diffusion coefficient and relative diffusion anisotropy of the normal spinal cord were measured. LSDI was compared with echo-planar diffusion imaging of the spine in three patients.

Adolescent↗

Multi-component apparent diffusion coefficients in human brain.

The signal decay with increasing b-factor at fixed echo time from brain tissue in vivo has been measured using a line scan Stejskal-Tanner spin echo diffusion approach in eight healthy adult volunteers. The use of a 175 ms echo time and maximum gradient strengths of 10 mT/m allowed 64 b-factors to be sampled, ranging from 5 to 6000 s/ mm2, a maximum some three times larger than that typically used for diffusion imaging. The signal decay with b-factor over this extended range showed a decidedly non-exponential behavior well-suited to biexponential modeling. Statistical analyses of the fitted biexponential parameters from over 125 brain voxels (15 x 15 x 1 mm3 volume) per volunteer yielded a mean volume fraction of 0.74 which decayed with a typical apparent diffusion coefficient around 1.4 microm2/ms. The remaining fraction had an apparent diffusion coefficient of approximately 0.25 microm2/ms. Simple models which might explain the non-exponential behavior, such as intra- and extracellular water compartmentation with slow exchange, appear inadequate for a complete description. For typical diffusion imaging with b-factors below 2000 s/mm2, the standard model of monoexponential signal decay with b-factor, apparent diffusion coefficient values around 0.7 microm2/ms, and a sensitivity to diffusion gradient direction may appear appropriate. Over a more extended but readily accessible b-factor range, however, the complexity of brain signal decay with b-factor increases, offering a greater parametrization of the water diffusion process for tissue characterization.

Adult↗

Partial wavelet encoding: a new approach for accelerating temporal resolution in contrast-enhanced MR imaging.

We propose a new approach using wavelet encoding to improve temporal resolution in contrast-enhanced magnetic resonance (MR) imaging. Exploiting the unique property of wavelets localized in space and frequency, we construct an efficient encoding scheme to capture signal changes due to contrast agent uptake, which in general is spatially localized with low- and mid-range frequency components. On the basis of space-frequency analysis, we describe mathematical formulations of our method and discuss its theoretical advantages over Fourier-based phase-encoding methods (the keyhole and reduced-encoding imaging by generalized-series reconstruction [RIGR] techniques). The results obtained in computer simulations and a phantom study demonstrate the feasibility and practical advantages of our approach.

Computer Simulation↗

Spin-Echo planar spectroscopic imaging for fast lipid characterization in bone marrow.

Lipid characterization of bone marrow in vivo with proton magnetic resonance spectroscopy was performed using Spin-Echo Planar Spectroscopic Imaging sequences. The methods are shown capable of rapidly generating two-dimensional chemical shift imaging data sets suitable for measuring lipid indices that reflect unsaturation levels among triglycerides, as demonstrated in oil phantoms and bone marrow from a healthy volunteer. The volume coverage, spatial resolution, acquisition speed, and spectral characteristics of Spin-Echo Planar Spectroscopic Imaging should make it attractive for clinical studies of diseases affecting normal lipid chemical composition.

Adult↗

Legg-Calvé-Perthes disease: MR imaging evaluation during manual positioning of the hip--comparison with conventional arthrography.

PURPOSE: To evaluate the use of magnetic resonance (MR) imaging during manual positioning of the hip, or multipositional MR imaging, in an open-magnet configuration to study femoral head containment, articular congruency, and femoral head deformity in Legg-Calvé-Perthes disease. MATERIALS AND METHODS: In 12 children with advanced Legg-Calvé-Perthes disease, multipositional MR imaging and conventional arthrography were compared in the assessment of containment, femoroacetabular congruency, and femoral head deformity. Images of the hips in several positions were compared subjectively and objectively. RESULTS: MR imging correlated well with arthrography for overall subjective assessment of severity of disease (r = 0.71, P = .01), with good interobserver agreement (kappa = 0.65, P < .001). MR images demonstrated all cases of hinge abduction shown arthrographically. However, MR imaging failed to depict one case of femoral head flattening. MR imaging correlated well with arthrography in the objective evaluation of joint fluid and lateral subluxation (r = 0.80, P < .01). MR imaging correlated poorly with arthrography in the measurement of sphericity of the femoral head. CONCLUSION: Multipositional MR imaging with an open-magnet configuration was comparable to arthrography for demonstration of femoral head containment and congruency of the articular surfaces of the hip. In the evaluation of deformity, it performed less well.

Arthrography↗

MR line scan diffusion imaging of the brain in children.

BACKGROUND AND PURPOSE: MR imaging of the self-diffusion of water has become increasingly popular for the early detection of cerebral infarction in adults. The purpose of this study was to evaluate MR line scan diffusion imaging (LSDI) of the brain in children. METHODS: LSDI was performed in four volunteers and 12 patients by using an effective TR/TE of 2736/89.4 and a maximum b value of 450 to 600 s/mm2 applied in the x, y, and z directions. In the volunteers, single-shot echo planar imaging of diffusion (EPID) was also performed. The patients (10 boys and two girls) ranged in age from 2 days to 16 years (average age, 6.6 years). Diagnoses included acute cerebral infarction, seizure disorder, posttraumatic confusion syndrome, complicated migraine, residual astrocytoma, encephalitis, hypoxia without cerebral infarction, cerebral contusion, and conversion disorder. In all patients, routine spin-echo images were also acquired. Trace images and apparent diffusion coefficient maps were produced for each location scanned with LSDI. RESULTS: In the volunteers, LSDI showed less chemical-shift and magnetic-susceptibility artifact and less geometric distortion than did EPID. LSDI was of diagnostic quality in all studies. Diffusion abnormalities were present in five patients. Restricted diffusion was present in the lesions of the three patients with acute cerebral infarction. Mildly increased diffusion was present in the lesions of encephalitis and residual cerebellar astrocytoma. No diffusion abnormalities were seen in the remaining seven children. CONCLUSION: LSDI is feasible in children, provides high-quality diffusion images with less chemical-shift and magnetic-susceptibility artifact and less geometric distortion than does EPID, and complements the routine MR examination.

Acute Disease↗

MR line-scan diffusion-weighted imaging of term neonates with perinatal brain ischemia.

BACKGROUND AND PURPOSE: MR diffusion-weighted imaging provides early demonstration of neonatal brain infarction. The evolution and limitations of diffusion-weighted imaging findings in newborns, however, have not been evaluated. Using line-scan diffusion imaging (LSDI), we investigated perinatal ischemic brain injury. METHODS: Nineteen term newborns (age, 9 hours to 8 days; mean age, 2.6 days) with perinatal brain ischemia were evaluated using LSDI (1520/62.5/1 [TR/TE/excitations]) (b maximum = 750 s/mm2) and T1- and T2-weighted spin-echo (conventional) MR imaging. Follow-up examinations were performed in seven patients and autopsy in one. Apparent diffusion coefficients (ADCs) were measured in deep gray matter, white matter, the cortex, and focal lesions. RESULTS: Based on conventional MR imaging or pathologic findings, patients were divided into two groups. Group 1 (n = 12) had symmetric/diffuse injury consistent with global hypoperfusion. Group 2 (n = 7) had focal/multifocal injury suggesting cerebrovascular occlusion. ADCs were abnormal at initial examination in 10 newborns in group 1 and in all newborns in group 2. The results of LSDI were abnormal before conventional MR imaging was performed in three newborns in group 1. ADCs were maximally decreased between days 1 and 3 in deep gray matter, perirolandic white matter, and focal lesions. Delayed decreases in ADCs were observed in subcortical white matter from days 4 through 10 in three patients in group 1. CONCLUSION: After global hypoperfusion, LSDI showed deep gray matter and perirolandic white matter lesions before conventional MR imaging. LSDI may underestimate the extent of injury, however, possibly because of variations in the compartmentalization of edema, selective vulnerability, and delayed cell death. Differences in LSDI of symmetric/diffuse and focal/multifocal lesions may reflect differences in pathophysiology or timing of the injury. These findings may have implications for acute interventions.

Asphyxia Neonatorum↗

Optimization of chemical shift selective suppression of fat.

Strategies to optimize flip angles for chemical shift selective fat suppression are discussed. Mathematical models for fat suppression in spoiled gradient recalled acquisition, spin echo, and RARE, which incorporate steady state conditions and multiple spectral components of fat, are developed. The optimal suppression flip angle is found to be larger than that determined with a single fat component model by more than 10 degrees due to contributions from unflipped components such as olefinic and glycerol protons that lie outside the suppression band.

Adipose Tissue↗

Developing epiphysis: MR imaging characteristics and histologic correlation in the newborn lamb.

PURPOSE: To correlate magnetic resonance (MR) signal characteristics of developing regions at the ends of bones with the histologic findings. MATERIALS AND METHODS: In 36 newborn lamb epiphyses (including cartilage of the epiphysis and physis, and bone of the secondary ossification center and juxtaphyseal metaphysis), signal intensity and thickness of cartilaginous regions seen on MR images were correlated with architecture and thickness of zones shown in corresponding histologic sections. Possible effects of T2, magnetization transfer, fat or water content, chemical shift, and anisotropy on differences in regional signal intensity were evaluated. RESULTS: MR imaging depicted five regions between the secondary ossification center and the metaphysis corresponding histologically to (a) zone of provisional calcification of the secondary ossification center, (b) physis of the secondary ossification center, (c) epiphyseal cartilage, (d) physis, and (e) zone of provisional calcification. The thickness of regions shown on T1- and T2-weighted images correlated with that of histologic zones (r = .9). T2 signal intensity and relaxation time were greater in physeal than in epiphyseal cartilage (P < .01). No regional differences due to fat or water content, magnetization transfer, chemical shift, or anisotropy were found. CONCLUSION: MR imaging findings differentiate epiphyseal and physeal regions and correlate with histologic findings. T2 is slower in physeal than in epiphyseal cartilage, probably reflecting differences in water binding.

Animals↗

MR imaging of pelvic floor continence mechanisms in the supine and sitting positions.

OBJECTIVE: Our goal was to determine the anatomic differences in pelvic floor anatomy for continent women and women with stress incontinence using MR imaging and to assess whether these anatomic differences depend on the position of the subject during imaging. SUBJECTS AND METHODS: Eight continent volunteers and eight women with stress incontinence underwent MR imaging in the supine and sitting positions. For imaging, we used an open-configuration 0.5-T magnet. T2-weighted images were obtained in the midline sagittal plane with subjects at rest and at maximal pelvic floor strain in 5 sec using a modified fast spin-echo sequence. In the axial plane, thin-section T2-weighted images were obtained with subjects at rest using a standard fast spin-echo technique. Images were evaluated for mobility of the urethra and bladder neck and for integrity of the vagina, levator ani, and supporting fascia. RESULTS: Pelvic floor laxity and abnormalities of the supporting fascia were more common in incontinent women than in continent women. Both descent of the bladder neck when subjects strained and the posterior urethrovesical angle were not significantly greater when subjects were measured in the sitting position (p < .1). CONCLUSION: Changes of pelvic floor laxity related to incontinence can be seen with subjects in both the supine and the sitting positions but are increased in the sitting position.

Adult↗

Diffusion-weighted MR imaging in hypertensive encephalopathy: clues to pathogenesis.

PURPOSE: Hypertensive encephalopathy, a complex of cerebral disorders, including headache, seizures, visual disturbances, and other neurologic manifestations, is associated with a variety of conditions in which blood pressure rises acutely. It has been ascribed to either exuberant vasospasm with ischemia/infarction or breakthrough of autoregulation with interstitial edema. Diffusion-weighted MR imaging may be used to determine whether the edema in hypertensive encephalopathy is cytotoxic or vasogenic in origin. METHODS: Diffusion-weighted imaging was performed using the double line scan diffusion imaging technique on a 1.5-T MR system. Seven patients with hypertensive encephalopathy were imaged within 1 day of the onset of their symptoms. Apparent diffusion coefficient maps as well as low and high b-factor images were acquired. The two-tailed paired Student's t-test was used to compare the apparent diffusion coefficients in edematous brain regions with those of normal white matter. RESULTS: In all cases the apparent diffusion coefficient maps of the patients with hypertensive encephalopathy showed increased signal in regions corresponding to increased T2 signal on standard T2-weighted (low b-factor) images. Quantitative apparent diffusion coefficients in regions of abnormal T2 signal were 1.36 +/- 0.14 microm2/ms, compared with 0.80 +/- 0.05 microm2/ms in normal white matter. Diffusion-weighted (high b-factor) T2-weighted images did not show abnormal signal. CONCLUSION: Diffusion-weighted MR imaging shows that the edema in hypertensive encephalopathy is of vasogenic origin and does not represent ischemia or infarction. This finding may have therapeutic implications.

Adult↗

Multiecho approaches to spectroscopic imaging of the brain.

Spectroscopic imaging (SI) with nuclear magnetic resonance (NMR) is one of the most powerful tools available for studying brain chemistry in vivo. Both proton (1H) and phosphorus (31P) NMR offer valuable biochemical information that can in principle be mapped throughout the entire brain, thereby enhancing our understanding of brain function. With the exception of protons from tissue water and the triglycerides of adipose tissue, however, nuclei contributing to the NMR signals of living tissue are in relatively small (millimolar) concentrations. The low concentration of metabolite nuclei reduces the overall sensitivity of conventional SI techniques, making high-quality metabolite mapping a lengthy procedure. This problem has led to the development and testing of nonconventional methods for reducing SI scan times, including techniques based on the collection of multiple spin-echoes. The extent to which multiecho methods can be used to decrease SI scan times and maintain high-quality metabolite mapping depends on several factors. These include the spectral transverse relaxation times, the spectral resolution required, and J-coupling interactions. We have discussed these various technical aspects of multiecho SI methods as applied to 1H and 31P spectroscopic imaging of the living brain.

Animals↗