Proceedings: Small airways disease in rheumatoid arthritis.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to R Turner.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
PURPOSE: To investigate the causal connections between ischemia and the hyperintensity in diffusion-weighted MR images that has been associated with it. METHODS: Diffusion-weighted and T2-weighted MR imaging were used in a feline global cerebral ischemia/reperfusion model. Single 30-minute vascular occlusions followed by reperfusion were studied. Global occlusions were used to avoid interpretive complications associated with the temporally unstable hemodynamics of the penumbral zones around focal occlusions and the possible growth of the ischemic and penumbral regions with time. RESULTS: Diffusion-weighted hyperintensity and the associated diffusional slowing were not attributable exclusively to the cessation of blood flow because: 1) it does not appear abruptly at the onset of ischemia; 2) it resolves slowly early in reperfusion; and 3) it reappears after prolonged reperfusion. CONCLUSION: The times during which diffusion-weighted hyperintensity is manifested during ischemia, and recovers with reperfusion, point to a role for energy metabolism failure.
The widespread use of long-term intravenous catheters has produced some concern on the part of the clinician with respect to morbidity and occasional mortality associated with their use. Fourteen polymer surfaces were evaluated in experimental animals in this study. Several of the materials are commercially available; the others are experimental. In all, 160 catheters were placed in the femoral and jugular veins through side branches. The catheters were evaluated in terms of thrombosis, phlebitis, and periphlebitis, using an arbitary grading system. Scanning electron microscopy and light microscopy were employed to document the results. The most successful catheter materials were next evaluated in man, using the same experimental parameters. It is our belief that the observed thrombosis associated with morbidity is largely due to the surface characteristics of the catheter materials. These characteristics are largely surface phenomena related to the interactions between the tissue and catheter material. In this study, we have attempted to determine whether there are any significant differences in thrombogenicity and/or long-term function between the several currently available catheters. Based on this study, ethylene acrylic acid appears to be the most nonthrombogenic surface of the material tested.