Search PubMed⌕ Search

Biomedical subjects

R Turner

Publications and source records attributed to R Turner.

At least 37 records · Page 2Linked to original sources

Exhaled breath condensate pH is a robust and reproducible assay of airway acidity.

Exhaled breath condensate (EBC) pH is low in several lung diseases and it normalises with therapy. The current study examined factors relevant to EBC pH monitoring. Intraday and intraweek variability were studied in 76 subjects. The pH of EBC collected orally and from isolated lower airways was compared in an additional 32 subjects. Effects of ventilatory pattern (hyperventilation/hypoventilation), airway obstruction after methacholine, temperature (-44 to +13 degrees C) and duration of collection (2-7 min), and duration of sample storage (up to 2 yrs) were examined. All samples were collected with a disposable condensing device, and de-aerated with argon until pH measurement stabilised. Mean EBC pH (n=76 subjects, total samples=741) was 7.7+/-0.49 (mean+/-SD). Mean intraweek and intraday coefficients of variation were 4.5% and 3.5%. Control of EBC pH appears to be at the level of the lower airway. Temperature of collection, duration of collection and storage, acute airway obstruction, subject age, saliva pH, and profound hyperventilation and hypoventilation had no effect on EBC pH. The current authors conclude that in health, exhaled breath condensate pH is slightly alkaline, held in a narrow range, and is controlled by lower airway source fluid. Measurement of exhaled breath condensate pH is a simple, robust, reproducible and relevant marker of disease.

Acid-Base Equilibrium↗

High resolution MRI of the brain at 4.7 Tesla using fast spin echo imaging.

Over recent years, high field MR scanners (3 T and above) have become increasingly widespread due to potential advantages such as higher signal-to-noise ratio. However, few examples of high resolution images covering the whole brain in reasonable acquisition times have been published to date and none have used fast spin echo (FSE), a sequence commonly employed for the acquisition of T(2) weighted images at 1.5 T. This is mostly due to the increased technical challenges associated with uniform signal generation and the increasingly restrictive constraints of current safety guidelines at high field. We investigated 10 volunteers using an FSE sequence optimized to the 4.7 T environment. This sequence allows the acquisition of 17- and 34-slice data sets with an in-plane resolution of approximately 500 microm x 500 microm and a slice thickness of 2 mm, in 5 min 40 s and 11 min 20 s, respectively. The images appear T(2) weighted, although the contrast is due to the combined effects of chosen echo time, magnetization transfer, direct radio frequency saturation and diffusion as well as the T(1) and T(2) relaxation times of the tissue. The result is an excellent detailed visualization of anatomical structures, demonstrating the great potential of 4.7 T MRI for clinical applications. This paper shows that, with careful optimization of sequence parameters, FSE imaging can be used at high field to generate images with high spatial resolution and uniform contrast across the whole brain within the prescribed power deposition limits.

Adult↗

Impingement syndrome associated with whiplash injury.

We examined 524 patients with whiplash injuries for delayed onset of shoulder pain in order to establish whether this was due to impingement syndrome. A total of 476 patients (91%) responded to a questionnaire of which 102 (22%) were entered into the study; 43 had both a positive impingement sign and Neer test. The incidence of impingement-type pain was 9%. After treatment 23 patients (5%) had a significant improvement in their symptoms, ten (2%) had a moderate improvement and nine had no improvement. Impingement-type pain can occur after whiplash injuries and can be successfully treated.

Humans↗

Support needs of veterinary surgeons during the first few years of practice: perceptions of recent graduates and senior partners.

Postal surveys or personal interviews of 76 recent veterinary graduates and their 49 employers were undertaken to establish their perceptions of good practice when integrating a new graduate into a business and their preferred methods of assessment and development. Practice type and location were the main influences on graduates looking for their first job. Interviews were mostly informal. Employers expected basic veterinary competence and candidates expected good quality support. Most graduates (93 per cent) had their own consultations on the first day. During early consultations 2 per cent of senior vets accompanied the new graduate, 95 per cent of practices provided senior back-up either in person or by telephone but in 3 per cent no back-up was available. Most new graduates (90 per cent) were satisfied with their workload. Three-fifths were on-call within the first week, and 95 per cent within a month. Graduates received calls directly in 45 per cent of practices, in 9 per cent seniors screened the calls, and the remainder used a third party. Assistance from experienced lay staff varied greatly. Discussion of problems was mainly informal. There was little spontaneous feedback and problems resulted from inadequate communication. One in three new graduates left their first job within two years, and one in six identified lack of support, heavy workload, stress or clashes with staff as a primary reason. This high turnover was a problem for employers. From the new graduates' perspectives, initial problems included: being on call (59 per cent), financial aspects (47 per cent) and surgery (43 per cent). Communicating with clients and learning to prioritise jobs were also difficult. New graduates took longer over procedures (79 per cent of employers commented) and required extra back-up (91 per cent) both of which reduced income (59 per cent). Nearly all the seniors felt that their current new graduates had coped 'quite well', although it was claimed that new graduates lacked the ability to talk to clients at the appropriate level, wanted to bring all their scientific knowledge to bear on every case, and often failed to consider the obvious or to appreciate clients' needs. Only 18 per cent of practices had formal and regular review procedures but all monitored the response of clients and watched the new graduate perform. Feedback to their new colleague was considered 'adequate' by 85 per cent of seniors, although 45 per cent of graduates felt they had not received enough. Eighty-three per cent of new graduates felt 'moderately prepared' by their undergraduate course, and 76 per cent of senior vets were 'generally satisfied' Both wanted improvements in extramural studies and increased exposure to routine cases. Senior partners sought greater commitment in the undergraduate curriculum to financial/legal issues and communication skills. Over a third of employers (38 per cent) had a 'great influence' on the choice of continuing professional development courses for their recent graduates. New graduates chose courses to deal with a perceived weakness, or to specialise, and welcomed opportunities to meet other new graduates and share early experiences. It was concluded that turnover and staff problems would be reduced if practices became more effective in coping with new arrivals, especially by supporting their development.

Attitude of Health Personnel↗

RF inhomogeneity compensation in structural brain imaging.

Three-dimensional T(1)-weighted magnetization-prepared rapid gradient-echo (MP-RAGE) sequences with centric phase encoding (PE) in the inner loop provide structural brain images with a high spatial resolution and high tissue contrast. A disadvantage of this sequence type is the susceptibility to inhomogeneities of the radiofrequency (RF) coil, which may result in poor image contrast in some peripheral regions. A special excitation pulse is presented which compensates for these effects in both the head/foot and anterior/posterior directions. This pulse has a duration of only 1.3 ms and is thus compatible with the short repetition times (TRs) required for MP-RAGE imaging. It is shown experimentally that images acquired with the compensation pulse may be segmented without using intensity correction algorithms during data postprocessing.

Artifacts↗

Detecting latency differences in event-related BOLD responses: application to words versus nonwords and initial versus repeated face presentations.

We introduce a new method for detecting differences in the latency of blood oxygenation level-dependent (BOLD) responses to brief events within the context of the General Linear Model. Using a first-order Taylor approximation in terms of the temporal derivative of a canonical hemodynamic response function, statistical parametric maps of differential latencies were estimated via the ratio of derivative to canonical parameter estimates. This method was applied to two example datasets: comparison of words versus nonwords in a lexical decision task and initial versus repeated presentations of faces in a fame-judgment task. Tests across subjects revealed both magnitude and latency differences within several brain regions. This approach offers a computationally efficient means of detecting BOLD latency differences over the whole brain. Precise characterization of the hemodynamic latency and its interpretation in terms of underlying neural differences remain problematic, however.

Adult↗

Compensation of susceptibility-induced BOLD sensitivity losses in echo-planar fMRI imaging.

Gradient-echo echo-planar imaging is a standard technique in functional magnetic resonance imaging (fMRI) experiments based on the blood oxygenation level-dependent (BOLD) effect. A major problem is the occurrence of susceptibility gradients near air/tissue interfaces. As a consequence, the detection of neuronal activation may be greatly compromised in certain brain areas, especially in the temporal lobes and in the orbitofrontal cortex. Common approaches to overcome this problem, such as z-shimming or the use of tailored radio frequency pulses, usually compensate only for susceptibility gradients in the slice selection direction. In the present study, the influence of susceptibility gradients in the phase encoding direction is investigated both theoretically and experimentally. It is shown that these gradients influence the effective echo time TE and may reduce considerably the local BOLD sensitivity, even in the case of acceptable image intensities. A compensation method is proposed and tested in an fMRI experiment based on a hypercapnic challenge. The results suggest that the compensation method allows for the detection of activation in brain areas which are usually unavailable for BOLD studies.

Brain↗

Ultrastaging of early colon cancer using lymphatic mapping and molecular analysis.

Approximately one-third of node-negative colon cancers will recur, possibly due to understaging and inadequate pathological examination of lymph nodes (LNs). We evaluated the sensitivity, accuracy and feasibility of staging based on lymphatic mapping, focused examination, and molecular analysis of the sentinel node (SN) in patients with primary colorectal carcinoma. Between 1996 and 2000, 100 patients with colon carcinoma (CRC) underwent lymphatic mapping immediately after peritumoral injection of 1.0 cc of isosulphan blue dye. All LNs in the CRC specimen were examined by routine haematoxylin and eosin (H&E) staining. Sentinel nodes were examined by step serial sectioning, cytokeratin immunohistochemistry (CK-IHC) and/or reverse transcriptase-polymerase chain reaction (RT-PCR) analysis in an attempt to identify occult micrometastatic disease. Lymphatic mapping was successful in 97% of the cases. There were 5 false-negative cases, predominately associated with T3/T4 tumours. Aberrant lymphatic drainage was identified in 8 patients (8%) altering the operative approach. 26 patients had H&E-positive LNs. In 74 patients who were node-negative by routine H&E, 18 (24%) had occult nodal micrometastases missed on routine H&E examination, but detected by focused analysis of the SN. RT-PCR analysis of the SN was performed in 40 patients, 26 of which were negative by H&E and CK-IHC. In 12/26 (46%) of these patients, there was additional evidence of micrometastatic disease. In this study, focused examination of the SN in conjunction with RT-PCR analysis identified micrometastatic disease in a significant number of node-negative patients. This may have important implications when selecting patients for adjuvant treatment protocols.

Adult↗

No smoke without fire--simple recommendations to avoid arthroscopic burns.

Despite anecdotal stories, the potential of the arthroscope tip or the light cable end to cause thermal burns to the surgical drapes and to patients has not been investigated in orthopaedic surgery. This study shows that the arthroscopic tip registering a temperature of 41.9 degrees C, is unlikely to cause skin burns but causes singeing of drapes without combustion. The light cable end registers a temperature of 101 degrees C with the potential for causing skin burns. It has been demonstrated to cause combustion of disposable arthroscopic drapes within seconds at a distance of 0.5 cm. It is recommended that the light source should be switched on only after the light cable has been connected to the arthroscope. The light cable end must not rest on the drapes once the light source has been switched on, as thermal burns will occur within seconds. A retractable shield of 2.5 cm fitted to the light cable end may virtually avoid the potential for combustion.

Arthroscopy↗

Laparoscopic ultrasonography is a complement to cholangiography for the detection of choledocholithiasis at laparoscopic cholecystectomy.

BACKGROUND: Intraoperative cholangiography and laparoscopic ultrasonography are both used in the detection of common bile duct stones at laparoscopic cholecystectomy. The aim of this prospective study was to determine whether laparoscopic ultrasonography has an alternative or a complementary role with respect to cholangiography in achieving this end. METHODS: The biliary trees of 900 patients undergoing laparoscopic cholecystectomy were examined routinely by the two methods. The diagnostic power of each investigation and of the two techniques in combination was evaluated. The statistical non-random concordance between the two methods was also determined. RESULTS: Laparoscopic ultrasonography was performed in all 900 patients. Cholangiography was performed in 762 (85 per cent). The mean (range) duration was 9.8 (4-21) min for laparoscopic ultrasonography and 17.6 (7-42) min for cholangiography. For the detection of common bile duct stones, with a kappa coefficient of 0.57 (95 per cent confidence interval (c.i.) 0.43 to 0.71), the non-random concordance between the two methods was considered to be fair to good. The sensitivity of laparoscopic ultrasonography was 0.80 (95 per cent c.i. 0.65 to 0.91) and its specificity was 0.99 (95 per cent c.i. 0.98 to 1.00). The respective values for cholangiography were 0.75 (95 per cent c.i. 0.59 to 0.87) and 0.99 (95 per cent c.i. 0.98 to 1.00). The examinations combined had a sensitivity of 0.95 (95 per cent c.i. 0.86 to 0.99) and a specificity of 0.98 (95 per cent c.i. 0.96 to 1.00). CONCLUSION: Laparoscopic ultrasonography and intraoperative cholangiography are complementary, as the combination of both methods maximizes the intraoperative detection of choledocholithiasis.

Adult↗

Detection of MAGE-A3 in breast cancer patients' sentinel lymph nodes.

The detection of occult metastatic breast cancer cells by RT-PCR is limited by the poor specificity of most tumour mRNA markers. MAGE-A3 is a highly specific tumour mRNA marker that is not expressed in non-cancer cells. This study assesses MAGE-A3 mRNA as a molecular marker for the detection of tumour cells in the sentinel lymph nodes (SLN) of breast cancer patients. Serial frozen sections of SLN (n = 121) were obtained from 77 AJCC (American Joint Committee on Cancer) Stage I-IIIA breast cancer patients. MAGE-A3 mRNA analysis of SLN was performed by RT-PCR and Southern blot analysis. Tumour cells were detected in 48 of 121 (40%) SLN from 77 patients by H&E or IHC staining, and 35 of 77 (45%) patients, overall, had histopathologically (H&E and/or IHC) positive SLN. Among histopathologically negative SLN, 28 of 73 (38%) SLN were MAGE-A3 mRNA positive by RT-PCR. Overall, 41 of 77 (53%) patients and 50 of 121 (41%) SLN were positive for MAGE-A3. MAGE-A3 mRNA expression in the SLN occurred more frequently with infiltrating lobular carcinoma (P < 0.001) than with infiltrating ductal carcinoma, adding further evidence of possible phenotypic differences between these 2 subtypes of breast cancer. Due to its high specificity, MAGE-A3 mRNA is a potentially useful marker for detecting breast cancer cells in the SLN. One half of breast tumours expressed MAGE-A3 mRNA, which has important potential implications for antigen-specific targeted immunotherapy.

Adult↗

Cluster randomised controlled trial to compare three methods of promoting secondary prevention of coronary heart disease in primary care.

OBJECTIVE: To assess the effectiveness of three different methods of promoting secondary prevention of coronary heart disease in primary care. DESIGN: Pragmatic, unblinded, cluster randomised controlled trial. SETTING: Warwickshire. SUBJECTS: 21 general practices received intervention; outcome measured in 1906 patients aged 55-75 years with established coronary heart disease. INTERVENTIONS: Audit of notes with summary feedback to primary health care team (audit group); assistance with setting up a disease register and systematic recall of patients to general practitioner (GP recall group); assistance with setting up a disease register and systematic recall of patients to a nurse led clinic (nurse recall group). MAIN OUTCOME MEASURES: At 18 months' follow up: adequate assessment (defined) of 3 risk factors (blood pressure, cholesterol, and smoking status); prescribing of hypotensive agents, lipid lowering drugs, and antiplatelet drugs; blood pressure, serum cholesterol level, and plasma cotinine levels. RESULTS: Adequate assessment of all 3 risk factors was much more common in the nurse and GP recall groups (85%, 76%) than the audit group (52%). The advantage in the nurse recall compared with the audit group was 33% (95% confidence interval 19% to 46%); in the GP recall group compared with the audit group 23% (10% to 36%), and in the nurse recall group compared with the GP recall group 9% (-3% to 22%). However, these differences in assessment were not reflected in clinical outcomes. Mean blood pressure (148/80, 147/81, 148/81 mm Hg), total cholesterol (5.4, 5.5, 5.5 mmol/l), and cotinine levels (% probable smokers 17%, 16%, 19%) varied little between the nurse recall, GP recall, and audit groups respectively, as did prescribing of hypotensive and lipid lowering agents. Prescribing of antiplatelet drugs was higher in the nurse recall group (85%) than the GP recall or audit groups (80%, 74%). After adjustment for baseline levels, the advantage in the nurse recall group compared with the audit group was 10% (3% to 17%), in the nurse recall group compared with the GP recall group 8% (1% to 15%) and in the GP recall group compared with the audit group 2% (-6% to 10%). CONCLUSIONS: Setting up a register and recall system improved patient assessment at 18 months' follow up but was not consistently better than audit alone in improving treatment or risk factor levels. Understanding the reasons for this is the key next step in improving the quality of care of patients with coronary heart disease.

Aged↗

Assessing study-specific regional variations in fMRI signal.

In this paper, we present a post hoc method for identifying regions where functional MRI data are subject to signal reduction that may compromise sensitivity to activations. The motivation for developing this technique derives from recent language studies that showed responses in the inferior temporal lobe that could be detected by PET but not by fMRI. Reduced signal is due mostly to susceptibility artifacts and can be identified by comparing the T2* images (which are subject to susceptibility artifacts) with T2 images (which are not). However, T2 images are not usually acquired in fMRI studies. Therefore, we propose that areas with reduced signal can be identified by comparing T2* images that are corrected for nonuniformity with the original uncorrected images. The technique provides a voxel-wise characterization of signal reduction that pertains to the particular data that enter into a statistical model. It requires only the functional data and can thus be applied post hoc and without any additional scans.

Artifacts↗

Modeling geometric deformations in EPI time series.

Even after realignment there is residual movement-related variance present in fMRI time-series, causing loss of sensitivity and, potentially, also specificity. One cause is the differential deformation of the sampling matrix, by field inhomogeneities, at different object positions, i.e., a movement-by-inhomogeneity interaction. This has been addressed previously by using empirical field measurements. In the present paper we suggest a forward model of how data is affected by an inhomogeneous field at different object positions. From this model we derive a method to solve the inverse problem of estimating the field inhomogeneities and their derivatives with respect to object position, directly from the EPI data and estimated realignment parameters. The field is modeled as a linear combination of cosine basis fields, which facilitates a fast way of implementing the necessary matrix operations. Simulations suggest that the solution is tractable and that the fields are estimable given the deformed images and knowledge of the relative positions at which they have been acquired. An experiment on a subject performing voluntary movements in the scanner yielded plausible estimates of the deformation fields and their application to "unwarp" the time series significantly reduced movement-related variance.

Adult↗

Does hypercapnia-induced cerebral vasodilation modulate the hemodynamic response to neural activation?

Increases in cerebral blood flow produced by vasoactive agents will increase blood oxygen level-dependent (BOLD) MRI signal intensity. The effects of such vasodilation on activation-related signal changes are incompletely characterized. The two signal changes may be simply additive or there may be more a complex interaction. To investigate this, BOLD MRI was performed in four normal male subjects using T2*-weighted echo planar imaging; brain volumes were acquired every 6.2 s, using a Siemens VISION scanner operating at 2 Tesla; each volume consisted of 64 sequential transverse slices (64 x 64 pixels per slice, 3 x 3 x 3 mm). Sixteen periods of visual stimulation were produced using a flickering checkerboard (8 Hz, 31 s On/31 s Off); this was coupled with five periods of hypercapnia (4% inspired CO(2), 62 s On/124 s Off). Data were analyzed using SPM96. Mean signal intensity, calculated globally for the whole brain, closely mirrored changes in the partial pressure of end-tidal CO(2) (PCO(2)), and hypercapnia was associated with widespread significant signal increases (P < 0.001), predominantly within grey matter. As expected, the visual stimulation produced significant signal changes within the occipital cortex (P < 0.001). Within the occipital cortex, no significant interactions (P > 0.001) between the effects of the visual stimulation and PCO(2) were present. The increases in PCO(2) imposed dynamically in the present study would increase cerebral blood flow by between 25 and 40%, an increase within the physiological range and comparable to that induced by neural activation. With this flow change the effects of vasodilation, on an activation-related signal change, are simply additive.

Adult↗

Event-related fMRI with simultaneous and continuous EEG: description of the method and initial case report.

We report on the initial imaging findings with a new technique for the simultaneous and continuous acquisition of functional MRI data and EEG recording. Thirty-seven stereotyped interictal epileptiform discharges (spikes) were identified on EEG recorded continuously during the fMRI acquisition on a patient with epilepsy. Localization of the BOLD activation associated with the EEG events was consistent with previous findings and EEG source modeling. The time course of activation was comparable with the physiological hemodynamic response function (HRF). The new methodology could lead to novel and important applications in many areas of neuroscience.

Cerebrovascular Circulation↗

Molecular clonality of in-transit melanoma metastasis.

In-transit melanoma is characterized by an aggressive pattern of recurrence that is associated with a poorer prognosis. Because in-transit melanoma is considered to result from the intralymphatic trapping of melanoma cells between the primary tumor and regional lymph nodes, it provides an excellent model to assess genetic events associated with early metastasis. The hypothesis of this study was to determine whether in-transit metastases are clonal in origin and therefore, may have specific genetic alterations uniquely associated with this disease and the development of early metastasis. This was assessed using loss of heterozygosity (LOH) analysis for specific DNA microsatellite loci. Seventy-nine paraffin-embedded in-transit melanoma lesions from 25 patients (range, 2 to 9 lesions per patient; average, 3.4 lesions per patient) were assessed for LOH using eight microsatellite DNA markers on six chromosomes. In 19 of 25 patients (76%) LOH was demonstrated for at least one marker. The most frequent microsatellite marker demonstrating LOH was D9S157 (56%). Using LOH microsatellite markers to assess intertumor heterogeneity, six of 79 tumors (7.6%) demonstrated different profiles when compared to other lesions from the same patient. In-transit metastases from those patients demonstrating intertumor heterogeneity were further assessed using laser capture microdissection and DNA analysis, and revealed no significant intratumor heterogeneity. In conclusion, LOH was frequently observed in in-transit melanoma metastasis. Based on LOH analysis, in-transit metastases are clonal in origin. The establishment of clinically successful in-transit melanoma metastasis requires specific genetic events that seem to be unique and homogeneous for each patient.

Clone Cells↗

Epoetin alfa in cancer patients: evidence-based guidelines.

Anemia is a common cause of cancer-related fatigue. A systematic review of the literature was performed to establish guidelines on the use of epoetin alfa for the treatment of anemia. The evidence in support of these guidelines was selected, reviewed, and summarized by the members of the Canadian Cancer and Anemia Guidelines Development Group. The effects of epoetin alfa on quality of life (QOL) in patients with cancer were examined in 5 randomized, placebo-controlled trials and 2 large, open-label, nonrandomized, community-based studies. The effects of epoetin alfa on red blood cell transfusion requirements were examined in 19 randomized controlled trials (RCTs) with 21 comparisons. All trials compared epoetin alfa to a suitable control group, examined specified outcome measures that could be analyzed, and studied patients with cancer who were receiving chemotherapy. Trials involving patients with hematologic malignancies originating in the bone marrow were excluded. Outcome measures included 1) quality of life (QOL) (as measured by scales including the Linear Analogue Self-Assessment [LASA] and the Functional Assessment of Cancer Therapy [FACT] subscales), and 2) transfusion requirements (as measured by the proportion of patients requiring transfusion and amount of transfusion). The analysis confirmed that epoetin alfa produced statistically significant and clinically relevant improvements in QOL in patients with cancer. The overall relative risk ratio for transfusion among patients receiving epoetin alfa was calculated to be 0.60 (95% Cl, 0.53-0.69; P < 0.00001), representing a 40% reduction in the proportion of patients requiring transfusion. These results support recommendations for the use of epoetin alfa in patients with cancer-related anemia.

Anemia↗