Search PubMed⌕ Search

Biomedical subjects

R Turner

Publications and source records attributed to R Turner.

At least 235 records · Page 13Linked to original sources

Purification and partial amino acid sequence of human urine protein 1. Evidence for homology with rabbit uteroglobin.

We describe the purification of Urine Protein 1 (UP1), a 14-16 kDa protein which occurs in the urine of patients with renal failure, and therefore may originate from the plasma or kidney. Amino acid sequencing shows that UP1 has significant homology with rabbit uteroglobin, a secretory protein of the uterus (during pregnancy) and lungs (both sexes), and previously identified only in lagomorphs (rabbits, hares, pikas). The finding of a human uteroglobin-like protein, which can be purified from a readily available source, may provide further opportunities to elucidate the, as yet, uncertain physiological functions of uteroglobin.

Amino Acid Sequence↗

Snapshot head imaging at 0.5 T using the echo planar technique.

The echo planar imaging (EPI) method and related variants of this technique can produce complete two-dimensional images from the data collected in a single experiment lasting a fraction of a second. EPI methods are used at 0.5 T to produce snapshot images of the human head with a spatial resolution of less than 2 mm.

Head↗

Hepatic and renal tolerability of long-term naproxen treatment in patients with rheumatoid arthritis.

Clinical and laboratory assessments of hepatic and renal function in rheumatoid arthritis (RA) patients who received naproxen for up to 6 months during two randomized, double-blind studies comparing naproxen 375 mg twice daily (n = 286) with naproxen 750 mg twice daily (n = 300) were analyzed. Patient groups were segregated by dosage, duration of treatment, and age at entry (less than 65 years v greater than or equal to 65 years), and laboratory measurements of SGOT, SGPT, serum creatinine (Scr), and BUN were examined. Records of individual patients with clinically meaningful abnormalities in laboratory tests or adverse events of hepatic or renal origin were examined in detail. Over the duration of these studies, there were no clinically meaningful changes in mean laboratory values or differences in occurrences of abnormal values among the different patient groups. In both dosage groups, pretreatment incidences of clinically meaningful abnormalities in laboratory tests were similar to those in serial observations during treatment. Six patients who received naproxen 375 mg twice daily and four patients who received naproxen 750 mg twice daily had a hepatic or renal clinical event or distinctly abnormal laboratory value, but only three of these withdrew because of these problems. Occasional transient abnormalities of conventional laboratory tests of hepatic and renal function occurred in some patients during naproxen treatment. Such abnormalities called for careful patient monitoring but generally did not warrant immediate drug withdrawal.

Adult↗

Improvements in snap-shot nuclear magnetic resonance imaging.

New variants of the ultra-high-speed echo-planar imaging technique have been used to obtain snap-shot images of adult patients and volunteers at 0.1 T. Modified pulsed-gradient sequences together with non-linear signal sampling and activity screened gradients have greatly improved the image quality obtainable by single-shot methods. A particular variant, modulus blipped echo-planar single-pulse technique (MBEST), although slightly slower than the blipped echo-planar single-pulse technique (BEST), is experimentally more robust and incorporates intrinsic T2 weighting. An account of these improvements together with some experimental results is presented.

Adult↗

Separation and characterisation of glycoproteins from normal, pregnancy, and acute inflammatory sera.

A system of multiple chromatography combining anion-exchange, gel filtration, and affinity chromatography has been devised to separate several acute phase proteins from serum, including alpha 1 acid glycoprotein, transferrin, alpha 1-antichymotrypsin, alpha 1-antitrypsin and haemopexin. Only 5-15 ml of blood is required to provide milligram quantities of the purified proteins for further biochemical analysis. The system has been applied in a study of pregnancy and some diseases in order to investigate the changes in the serum protein profile and in individual proteins.

Acute-Phase Proteins↗

Real-time movie imaging from a single cardiac cycle by NMR.

Using a 1-m-bore superconductive magnet at 0.1 T, whole-body transverse images through adult humans have been obtained at repetition times of 57 ms. The techniques used were minor variations of echo-planar imaging (EPI) employing large pulsed gradients to provide complete coverage of the plane in phase space, and low-angle RF excitation sequences allowing rapid repetition of the experiment. In addition active magnetic screening of the gradient coils was implemented to protect the surrounding magnet from the eddy currents induced by the necessarily fast switching of the large gradient fields.

Adult↗

Does the binding of cyclosporine to calmodulin result in immunosuppression?

The cyclosporines are a family of cyclic endecapeptides that cause a profound suppression of primary immune stimulation both in vitro and in vivo. Recently, the regulatory protein calmodulin (CaM) has been implicated as a target for cyclosporin A (CsA) binding. This study utilized two less-active isomers of CsA to evaluate the specificity and biological significance of CaM binding. The three cyclosporines exhibited equivalent in vitro binding to CaM, regardless of immunosuppressive activity. Furthermore, CaM-dependent enzyme systems were inhibited equally by active and inactive cyclosporines, but only at concentrations 100 times those necessary to block lymphocyte activation. Thus the exquisite immunosuppressive stereospecificity displayed by cyclosporine isomers is not reflected in the binding to and inhibition of CaM, suggesting that inhibition of CaM-dependent processes is not sufficient to explain the immunosuppressive activity of CsA.

Animals↗

Eel electric organ: hyperexpressing calmodulin system.

The electroplax of the electric eel Electrophorus electricus is the most abundant source of the calcium-binding protein calmodulin. The electroplax has 250 times the amount of calmodulin and its mRNA than eel skeletal muscle. Our data suggest that there is no major difference in gene copies, the degree of methylation, or genome rearrangement of the calmodulin gene in DNAs from eel electroplax and muscle. Differences in the calmodulin-binding proteins in electroplax and muscle suggest a differential role for the functional expression of calmodulin in cellular regulation.

Animals↗

Isoelectric points of urinary light chains in myelomatosis: analysis in relation to nephrotoxicity.

Measurements of the isoelectric point (pI), sialic acid content, and polymerisation were made of 43 light chains isolated from the urine of patients with myelomatosis excreting large amounts of light chains. The pIs ranged from 3.5-9.5, and 23 were greater than 7.0. Sialylation was detected in 62% of light chains, and 69% showed microheterogeneity of charge. There was no clear association between the pI, sialylation, or polymerisation and the presence of renal failure, as assessed by serum creatinine concentrations. Light chains with pI spectrotype in the basic range, however, were found to produce more proximal tubular dysfunction than acidic light chains.

Acute Kidney Injury↗

RNs may cost less than you think.

The health care environment is in a new era. Hospital and nursing administrators will be faced with tough decisions regarding number and skill level of staff. Productivity of various levels of nursing personnel is one parameter upon which decisions can be made. In this research, productivity is defined as the percentage of time spent in direct care, indirect care, and unit-related activities. The research indicates that the higher the level of personnel, the higher the productivity.

Clinical Competence↗

Elevated blood neutrophil concentration in mania.

Total, differential, and absolute blood cell counts were compared in 66 untreated manics and 178 untreated schizophrenics. Mania was associated with significantly higher total leukocyte counts (p less than .001), accounted for by a significant increase (p less than .0001) in the number of neutrophils. There were no significant differences between the two groups in any other blood cell elements. Using normative values, manic patients had significantly higher frequencies of both leukocytosis (25.8% vs. 12.4%) and neutrophilia (34.8% vs. 12.4%) than the schizophrenic group. These data suggest a significant association between leukocytosis, neutrophilia, and mania.

Adult↗