Hepatic contrast-enhanced CT: statistical design for prospective analysis.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to R Tello.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
OBJECTIVE: This study was undertaken to compare whole-body turbo short inversion time inversion recovery MR imaging and 99mTc-methylene diphosphonate planar scintigraphy in the examination of patients with suspected skeletal metastases. SUBJECTS AND METHODS: Twenty-five patients with known or suspected skeletal metastatic disease underwent both whole-body turbo short inversion time inversion recovery MR imaging and whole-body 99mTc-methylene diphosphonate scintigraphy. RESULTS: MR imaging revealed metastases at 57 of 175 possible sites (sensitivity, 96.5%, specificity, 100%; positive predictive value, 100%). Scintigraphy revealed metastases at 43 of 175 possible sites (sensitivity, 72%; specificity, 98%; positive predictive value, 95%) (McNemar test, 0.01; p = .016). Discrepancies in skeletal evaluation by whole-body MR imaging and scintigraphy were observed in six (24%) of 25 patients. Soft-tissue abnormalities were identified in 13 (52%) of 25 patients with MR imaging alone. CONCLUSION: Preliminary results suggest that whole-body MR imaging is an effective method of examining patients with suspected skeletal metastases, with better sensitivity than conventional planar 99mTc-methylene diphosphonate scintigraphy.
Explore the source record for details and available documents.
RATIONALE AND OBJECTIVES: This study evaluated the value of dynamically enhanced fast low-angle shot (FLASH) magnetic resonance (MR) imaging in measuring cardiac output with and without dipyridamole pharmacological stress. METHODS: Ten subjects underwent rest and stress MR imaging. Rest images were acquired using electrocardiogram gated MR (turbo-FLASH: repetition time = 6 mseconds; echo time = 12 mseconds; flip angle = 12 degrees, inversion time = 100) 10 to 45 seconds after intravenous bolus of 0.04 mmol/kg gadolinium (Gd)-DTPA using a Siemens 1.0-tesla Magnetom SP. Stress was induced within the MR imaging scanner with 0.56 mg/kg dipyridamole over 4 minutes with stress MR images obtained after a second bolus of Gd-DTPA in exactly the same position and time intervals. Cardiac output was calculated with a least squares error analysis before and after dipyridamole stress for the left and right ventricles in all 10 patients, and comparison was made with cardiac output by Fick dilution technique during cardiac catheterization in seven patients. RESULTS: This MR analysis methodology shows reasonable correlation (r = 0.953) between left ventricular and right ventricular cardiac output with no effect on cardiac output during immediate dipyridamole stress. Fick dilution studies demonstrated a correlation of 0.96. CONCLUSIONS: Turbo-FLASH MR can demonstrate time-activity curves and cardiac output calculations consistent with theoretical predictions.
The purpose of this investigation was to study the relationship between both blood ammonia thresholds (AmT) and lactate thresholds (LT) during dynamic exercise in cardiac transplant patients (CTPs). Eleven male patients who had undergone orthotopic cardiac transplantation (age: 54 +/- 11 years, mean +/- SD; height: 165.1 +/- 6.6 cm; body mass: 78.3 +/- 16.1 kg) participated in this study. Each of them performed a bicycle ergometer test (ramp protocol) until volitional fatigue. During each test, gas exchange parameters and ECG responses were determined continuously. In addition, blood lactate and ammonia concentrations were measured every 2 min for determination of both LT and AmT, respectively. Peak values of oxygen uptake (Vo2), respiratory exchange ratio, ventilation, and heart rate averaged 15.9 +/- 3.03 mL.Kg-1.min-1, 1.02 +/- 0.06, 46.69 +/- 5.69 L.min-1, and 124 +/- 16 beats per minute, respectively. However, blood concentrations of lactate and ammonia at peak exercise were 3.7 +/- 0.4 mmol.L-1 and 85.6 +/- 31.7 micrograms.dL-1, respectively. LT and AmT were detected in 8 (72.7% of total) and 9 (81.8% of total) of 11 subjects, respectively. No significant differences were found between mean values of LT and AmT, when both were expressed either as Vo2 (10.01 +/- 1.19 vs 10.5 +/- 2.38 mL.kg-1.min-1, respectively) or as percent Vo2 peak (64.62 +/- 11.362 vs 66.48 +/- 9.19%, respectively). In addition, LT and AmT were significantly correlated (p < 0.05) when both were expressed either as Vo2 (mL.kg-1.min-1) or as percent Vo2 peak (r = 0.70 and r = 0.68, respectively). Our findings suggest that in CTPs, both LT and AmT occur at similar workloads, probably as a result of skeletal muscle alterations associated with chronic deconditioning and immunosuppressive therapy.
Quantitative information regarding competency in performing procedures is invaluable in attesting to a house officer's abilities when assessments need to be made. Thus, the means by which procedures, proficiency, and experience can be recorded and organized in an automated fashion need not be any further away than the nearest micro-computer. The procedure documenting system (PDS) automates the documenting of procedures and quantitative information pertaining to these procedures, and shortens the time demanded of the house officer to document procedures from a mean of 5.5 to 1.9 min. This paper is a description of the work done to automate the recording of procedures performed by housestaff at a teaching hospital and the acceptance by housestaff. This computer program takes the specific information and places it into a specialized database so that house officers can have detailed documentation attesting to their proficiency in various procedures. In addition, the program director can access the database to document the quantity of procedures to which an individual house officer has attained competence.
Traditionally computed axial tomography has had limitations in evaluating diseases that affect the tracheobronchial tree because of respiratory-induced artifacts, with the likelihood of missing lesions as a result of misregistration. Spiral computed tomography (CT) differs from conventional CT in that the entire thorax can be rapidly imaged in the axial plane after a single breath-hold. Five patients underwent non-contrast-enhanced volumetric CT, with emphasis on three-dimensional reconstruction, and endoscopic evaluation with pathologic confirmation. In all cases, there was complete corroboration between volumetric CT and endoscopic evaluation. The use of selective thresholds allowed the air within the tracheobronchial tree to be used as a negative contrast agent. Thus with the integration of selective windowing, detailed three-dimensional tracheobronchial anatomy may be elucidated. The absence of respiratory registration artifact due to the single breath-hold technique raises the confidence that three-dimensional and multiplanar images generated from such studies are accurate representations of the pathologic conditions at hand. By the integration of volumetric CT techniques and rapid three-dimensional display of tracheobronchial structures, volumetric CT bronchography becomes practical.
Consolidating personal computers (PCs) with nuclear medicine technology can create high computational power comparable with that produced by vendor-specific computer equipment, and at more affordable prices. The integration of a standard platform and operating system with a large installed base has enabled our department to maintain itself at the cutting edge of technology with minimal expense. Along with the savings from the purchase of PC software and hardware come the added advantage of rapid training of staff with minimal in-house effort, especially given the vast educational support in the general community. The integration of a standard platform and operating system with a large installed base has provided the nuclear medicine department with computational resources once unheard of because of economies of scale. The acceptance and integration of a pervasive, flexible technology into nuclear medicine have shown that state-of-the-art studies can be performed at low cost.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
OBJECTIVE: Established noninvasive methods for assessing myocardial ischemia have limitations that might be overcome by MR imaging. We investigated MR myocardial perfusion imaging and MR ventriculography, before and after dipyridamole-induced stress, to determine whether the superior spatial and temporal resolution of MR imaging has advantages for the evaluation of myocardial ischemia. SUBJECTS AND METHODS: Eighteen patients with symptoms suggestive of myocardial ischemia were examined by use of MR perfusion imaging and MR cineangiography before and during dipyridamole-induced stress. Multiplanar gradient-echo MR cineangiography and cardiac gated fast low-angle shot (turbo-FLASH) MR imaging during injection of gadopentetate dimeglumine were used. Results were compared with findings from perfusion scintigraphy and coronary arteriography. RESULTS: The accuracy of the combination MR technique for detecting myocardial ischemia was similar to that of scintigraphy. No significant difference was found between the MR technique and scintigraphy for detecting segments of myocardium supplied by stenosed coronary arteries (> 70% reduction in diameter, as determined by coronary arteriography). The sensitivity of the combination MR technique for angiographically detecting significant coronary artery narrowing was 92%, and the specificity was 100%. For scintigraphy, the sensitivity was also 92% and the specificity was 100%. CONCLUSION: Initial results indicate that a combination of stress MR myocardial perfusion imaging and MR ventriculography is feasible and that this technique can detect myocardial ischemia with an accuracy similar to that of scintigraphy. This technique may make more complete noninvasive assessment of myocardial ischemia possible.
Explore the source record for details and available documents.
90 patients with chronic diarrhoea underwent this prospective study. They were seen in a private hospital of Lima during 1990 and 1991. According to a methodologic plan for determining sources and the diseases that originate chronic diarrhoea. In all patients hematologic, bioquimic, coprocultures, coproparasitologic exams were done, chest and intestinal transit X-rays. All underwent duodenal content culture. Colon X-ray in 25 cases; proctosigmoidoscopy in 14 and upper digestive endoscopy in 19 patients. Abdominal echography in 12 and TAC in 2 cases. The final results showed as determinant diseases for chronic diarrhoea, according to their frequency: enteroparasitosis (23.3%), functional digestive disorders (20.0%), intestinal bacterial overpopulation (15.5%) of unknown origin (8.8%), colon diverticulus (7.7%) proven and probably (5.5%), lactose intolerance (3.3%), diabetes mellitus (2.2%), and in one case (1.1%) the following: intestinal linfoma, pancreas malignancy, AIDS, colonic and deformation and megaloblastic anemia. The causes of chronic diarrhoea are several and multifactorals and in this study we prove the preeminence of the intestinal parasitosis, functional disorders and intestinal bacterial overpopulation and with less frequency other pathologies.
The effectiveness of spiral computed tomography (CT) of the thorax performed with 60 mL of 60% contrast material was compared with that of conventional dynamic incremental CT performed with 120 mL of 60% contrast material. Fifty patients in whom contrast material-enhanced thoracic CT examination was necessary were assigned to undergo either spiral CT or dynamic incremental CT. Vascular opacification and mediastinal-lung image quality were graded independently by two observers. Vascular opacification and lung image quality were better with spiral CT than with conventional CT. Results of this pilot study encourage the use of spiral CT to decrease the volume of contrast medium used in patients undergoing thoracic CT.
A recently developed technique, spiral CT, allows rapid data acquisition through an entire anatomic region during a single breath-hold. High-quality spiral CT scans of the thoracic region have been obtained with volumes of contrast material that are small relative to those used with conventional CT. This essay illustrates the diseases of the aorta as seen on spiral CT performed with low volumes of contrast material.