Search PubMed⌕ Search

Biomedical subjects

R T Kennedy

Publications and source records attributed to R T Kennedy.

54 records · Page 3Linked to original sources

Quantitative in vivo monitoring of primary amines in rat caudate nucleus using microdialysis coupled by a flow-gated interface to capillary electrophoresis with laser-induced fluorescence detection.

A method for monitoring primary amines in vivo using microdialysis coupled on-line with capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC) with laser-induced fluorescence detection was explored. Dialysates were derivatized on-line with o-phthaldialdehyde/beta-mercaptoethanol and automatically transferred to a separation capillary by a flow-gated interface. Analytes were detected on-column using the 2 mW, 354 nm line of a He-Cd laser for excitation. Dialysis probes were perfused at 79 nL/min, resulting in relative recoveries of nearly 100%, which allowed quantitative monitoring. On-line detection limits were in the 20-50 nM range, and the response was linear up to 50 microM. Temporal resolution was between 45 s and 3 min and was limited by separation time or broadening of sample zones during transfer to the separation capillary, depending on the operational parameters. The system was applied to measurement of primary amines in the caudate nucleus of anesthetized rats. Using CZE for separation, it was possible to resolve and monitor several compounds, including aspartate and glutamate. The measured basal concentrations of aspartate and glutamate were 1.2 +/- 0.1 and 5.0 +/- 0.4 microM, respectively, which agrees well with literature values. Increases in in vivo aspartate and glutamate were monitored with 90 s temporal resolution during K+ depolarization using dialysis flow rates of 79 nL/min; however, temporal resolution of 45 s was possible at the expense of lower relative recovery if the dialysis flow rate was increased to 155 nL/min. The use of MEKC as the separation mode significantly increased the number of compounds that could be resolved and detected. Using MEKC to separate the dialysate samples allowed aspartate, glutamate, isoleucine, leucine, lysine, methionine, phenylalanine, taurine, tyrosine, and valine to be resolved and detected. The basal concentrations for these compounds using MEKC were 1.9 +/- 0.2, 4.1 +/- 0.2, 4.6 +/- 0.7, 2.6 +/- 0.3, 5.4 +/- 0.4, 1.8 +/- 0.2, 2.0 +/- 0.2, 11.3 +/- 1.3, 3.3 +/- 0.9, and 5.3 +/- 0.3 microM, respectively. The concentrations of these primary amines in the striatum were monitored after K+ depolarization with 3 min temporal resolution. This is the first microdialysis system to generate high relative recoveries and good temporal resolution simultaneously for multiple neurotransmitters.

Animals↗

Vesicular quantal size measured by amperometry at chromaffin, mast, pheochromocytoma, and pancreatic beta-cells.

Amperometric detection of exocytosis at single chromaffin cells has shown that the distribution of spike areas, or quantal size, is dependent on the volume and catecholamine concentration of individual secretory vesicles. The present work offers an alternate, simplified model to analyze the current spikes due to single exocytotic events. When the cube root of these spike areas is plotted as a histogram, a Gaussian distribution is obtained for chromaffin cells and also mast, pheochromocytoma, and pancreatic beta-cells. It was found that the relative SD of these distributions is similar to that for the vesicular radii, which also have a Gaussian distribution in all four cell types. In addition, this model was used to evaluate conditions where the quantal size of individual events was altered. When chromaffin cells were maintained in culture for < 6 days, spikes of approximately double the quantal size were obtained on repeated exposure to 60 mM K+. The results suggest a heterogeneous distribution of catecholamine-containing vesicles at later days in culture is responsible for this alteration.

Animals↗

Electrochemical detection of exocytosis at single rat melanotrophs.

Amperometry at a carbon fiber microelectrode was used to monitor secretion of peptide hormone from single melanotrophs of the intermediate lobe of the rat pituitary. The method is based on electrochemical oxidation of tryptophan and tyrosine residues of small proopiocortin-derived peptides secreted from these cells. For single-cell measurements, the electrode, which had a sensing diameter of approximately 9 microns and a total tip diameter of 30 microns, was positioned approximately 1 micron away from single melanotrophs. When cells were stimulated by application of 64 mM K+, a series of randomly occurring current spikes with an average area of 34 +/- 6 fC was observed. The current spikes were strongly dependent on the presence of Ca2+. Current spikes of nearly identical area and shape were also elicited by mechanical stimulation. Cyclic voltammograms obtained from cell releasates confirmed that the substance detected was a tryptophan- or tyrosine-containing peptide. On the basis of amperometric tests of the most abundant peptides in melanotrophs, it is concluded that the current spikes are due to detection of primarily alpha-melanocyte stimulating hormone. The spike area corresponds to 0.32 amol of alpha-melanocyte stimulating hormone. It is concluded that the current spikes represent detection of concentration pulses that are expected following exocytosis events.

Animals↗

Detection of exocytosis at individual pancreatic beta cells by amperometry at a chemically modified microelectrode.

Amperometry at a carbon fiber microelectrode modified with a composite of ruthenium oxide and cyanoruthenate was used to monitor chemical secretions of single pancreatic beta cells from rats and humans. When the insulin secretagogues glucose, tolbutamide, and K+ were applied to the cell, a series of randomly occurring current spikes was observed. The current spikes were shown to be due to the detection of chemical substances secreted from the cell. Chromatography showed that the primary secreted substance detected by the electrode was insulin. The current spikes were strongly dependent on external Ca2+, had an average area that was independent of the stimulation method, and had an area distribution which corresponded to the distribution of vesicle sizes in beta cells. It was concluded that the spikes were due to the detection of concentration pulses of insulin secreted by exocytosis.

Animals↗

Capillary electrophoresis-based immunoassay to determine insulin content and insulin secretion from single islets of Langerhans.

The development of a competitive immunoassay for insulin that is based on capillary zone electrophoresis with laser-induced fluorescence detection (CZE-LIF) is described. The assay uses fluorescein isothiocyanate-derivatized insulin (FITC-insulin) as a tracer and the Fab fragment of an anti-insulin monoclonal antibody as the immunoreagent. Reproducibility and reliability of the assay are improved when CZE capillaries are coated with a neutral hydrophilic polymer. The assay has an average relative standard deviation of 3.4% and a detection limit of 3 nM or about 6 fg injected. Using the assay, insulin content of single islets of Langerhans was determined to be 35 +/- 4 ng, which is in good agreement with literature values. The assay was also used to determine insulin secretion from single islets. During 5-min static incubations, 3 mM glucose elicited 0.8 +/- 0.2 ng of insulin release while 16 mM glucose elicited 3.2 +/- 0.5 ng of insulin release. These values are also in good agreement with previously reported results. These applications demonstrate the capability of rapidly determining a low level of protein in a complex biological microenvironment.

Animals↗

Selective preconcentration for capillary zone electrophoresis using protein G immunoaffinity capillary chromatography.

Capillaries with 150 microns inner diameter were packed with a perfused protein G chromatographic support and used as immunoaffinity preconcentrators for capillary zone electrophoresis. Antibody was loaded onto the protein G support to form an immunoaffinity stationary phase. Injection of samples onto the column caused selective retention and preconcentration of antigen. Injection of appropriate buffers onto the column caused desorption of the antibody and antigen which were then separated by capillary zone electrophoresis. The combination was used on-line and off-line. For on-line combination, a flow-gated interface coupled the two columns and allowed injection of desorbed zones onto the electrophoresis system. Off-line coupling required collection of desorbed fractions and then injection onto the electrophoresis system. Flow rates as high as 100 microL/min were used to load sample onto the affinity column. Desorbing flow rates had to be 1 microL/min or less to prevent excessive dilution during desorption. Using the system, 1 mL insulin samples could be loaded onto the affinity column and desorbed in volumes as small as 1 microL for 1000-fold preconcentration. The use of the preconcentrator with serum samples spiked with insulin was demonstrated.

Affinity Labels↗

Quantitative in vivo measurements using microdialysis on-line with capillary zone electrophoresis.

A system which couples microdialysis with capillary zone electrophoresis (CZE) on-line is used to monitor ascorbate and lactate in the caudate nucleus of rat brain. On-line interface of microdialysis probe and electrophoresis capillary, along with the high mass sensitivity of CZE, allows the probe to be operated at flow rates as low as 40 nl/min. Under these conditions, the relative recovery is nearly 100% and quantitative monitoring is possible. The microscale system also facilitates calibration by the low flow rate method. In spite of the low flow rate, temporal resolution in the 45-125 s range is possible for these compounds. The system is demonstrated by observing changes in ascorbate due to infusions of elevated K+ through the dialysis probe and systemic injections of amphetamine and an anesthetic (ketamine/xylazine/acepromazine mixture). Lactate is monitored in response to elevated K+ infusions.

Animals↗

Amperometric monitoring of chemical secretions from individual pancreatic beta-cells.

The goal of the work was to develop and test an amperometric method for measuring insulin secretion from individual pancreatic beta-cells. The electrode used was a carbon fiber microelectrode modified with a polynuclear ruthenium oxide/cyanoruthenate film. The chemically modified electrode allowed anodic detection of insulin in physiological buffers with a detection limit of 0.5 microM. To measure secretion, an electrode was positioned 1 micron away from a beta-cell that had been stimulated with K+ or glucose. Recordings made from the cells consisted of a series of current spikes averaging 38 ms full width at half-height. The spikes decreased in height and increased in width as the electrode was pulled away from the cell. Spikes were only observed if a modified electrode was used and its potential was sufficient to oxidize insulin. The area under the spikes correspond to approximately 600 zmol of insulin, which is within the expected range for vesicular insulin content. Spike area was independent of stimulation method. The results support the hypothesis that the electrode was anodically detecting a substance secreted from the cells by exocytosis. The results support, but do not prove, that insulin was the primary substance detected.

Cells, Cultured↗

Simultaneous measurement of oxygen and dopamine: coupling of oxygen consumption and neurotransmission.

Fast-scan cyclic voltammetry was used to simultaneously measure increases in dopamine concentration and decreases in O2 concentration evoked by brief electrical stimulation (two pulses at 10 Hz) in slices of rat caudate nucleus. Dopamine concentration began increasing immediately after the first pulse and reached a maximum within 200 ms of stimulation. The O2 concentration began to decrease 300-700 ms after onset of stimulus. Responses for both dopamine and O2 were dependent on external Ca2+ and were Cd2+ and tetrodotoxin sensitive. Only the O2 response was sensitive to CN- (0.15 mM). At short times after exposure to 50 microM ouabain, electrically stimulated dopamine overflow was increased by 150% and electrically stimulated changes in O2 concentration were unaffected. Maximum dopamine concentration was increased 28% by sulpiride (2 microM), 78% by L-DOPA (60 microM), 105% by nomifensine (10 microM) and unaffected by nialamide (10 microM). Maximum decrease in O2 concentration was increased by 25% by sulpiride and unaffected by nialamide, L-DOPA, or nomifensine. The decreases in O2 concentration are indicative of increased O2 consumption and are a measure of oxidative energy production evoked by electrical stimulation. The increase in dopamine is due to the release of dopamine balanced by uptake and serves as an indication of neurotransmitter activity. The results indicate that increases in oxidative energy production following electrical stimulation are dependent on external Ca2+ entry through Cd(2+)-sensitive channels. Possible mechanisms for this coupling are discussed.

Animals↗

Evoked neuronal activity accompanied by transmitter release increases oxygen concentration in rat striatum in vivo but not in vitro.

Dopamine and oxygen (O2) were measured in the caudate nucleus of anesthetized rats and in striatal slices during electrical stimulation. Simultaneous electrochemical detection of dopamine and O2 was accomplished with fast-scan cyclic voltammetry at a Nafion-coated carbon-fiber microelectrode. Stimulation of the medial forebrain bundle resulted in synaptic overflow of dopamine in the caudate nucleus. At the same time, O2 concentration increased in the extracellular fluid with two separate phases. The amplitude of the initial increase directly correlated with the frequency of the stimulus, with the time of maximum concentration reproducible across a range of frequencies. The second increase occurred at later times with a more random amplitude and with a broad, variable shape. Agents which blocked vasodilation affected both phases: atropine attenuated the initial increase, while the second feature was nearly absent after theophylline. Yohimbine and alpha-methyl-p-tyrosine did not affect the O2 responses. Local electrical stimulation of the slice preparation also resulted in dopamine overflow, but a prolonged decrease in O2 concentration accompanied this event. Striatal field stimulation in vivo produced changes in O2 concentration dependent on the relative position of the stimulating and working electrodes, but none of the responses resembled that seen in the caudate slice. Thus, while measurements in brain slices show O2 consumption as a result of stimulated neuronal activity, an apparent elevation of local cerebral blood flow during and after stimulation dominate the in vivo response.

Animals↗

Dynamic observation of dopamine autoreceptor effects in rat striatal slices.

Fast-scan cyclic voltammetry has been used to measure dopamine (DA) synaptic overflow in slices of rat caudate nucleus induced by electrical stimulation with one-, two-, and 50-pulse, 10-Hz trains. Synaptic overflow in this preparation is shown to be the result of the competing effects of release and cellular uptake. Release caused by all pulses was attenuated by the D2 agonist quinpirole (1 microM). The rapid time response of the measurements (100 ms) allows the autoinhibition induced by endogenous, released DA to be resolved in real time. The concentration of DA released during the second pulse of a train was 58% of that released by the first pulse, an effect that is partially blocked by the addition of 2 microM sulpiride, a D2 antagonist, to the perfusion buffer. DA release during the first stimulus pulse is unaffected by 2 microM sulpiride, suggesting that autoreceptors are not normally occupied in this preparation. Release caused by the third pulse was 14% of the first pulse and also could be partially enhanced by 2 microM sulpiride. The duration of the inhibition of release induced by endogenous DA was estimated by varying the interval between one-pulse stimulations until the overflow of DA induced by the second pulse was equal to that on the first; a half-time of approximately 17 s was found. The addition of picrotoxin (100 microM) and glutamate (10 microM) to the perfusion buffer did not affect stimulated release of DA, although the addition of atropine (100 microM) attenuated overflow for all the trains tested.

Acetylcholine↗

Strategies for low detection limit measurements with cyclic voltammetry.

Cyclic voltammetry of Nafion-coated, carbon-fiber electrodes is used to detect trace concentrations of dopamine, both in a flow injection apparatus and in the brain of an anaesthetized rat. To improve signal-to-noise ratios, the sources of noise during cyclic voltammetry have been determined and strategies have been developed to decrease the noise. With the potentiostat employed, the measured noise is comparable to that expected for Johnson noise from the feedback resistor of the current transducer. Additional noise arises from the waveform generator employed and, in some cases, line noise. Line noise is discriminated against by starting each cyclic voltammogram either in phase or 180 degrees out of phase with the line frequency. When used in vivo, additional noise also arises from the physiological activity of the animal. Detection limits are found to closely correspond to those predicted on the basis of simulation of the voltammetric shape and the measured noise. Detection limits are improved by the use of appropriate analog and digital filtering, ensemble averaging, and appropriate timing of repetitive cyclic voltammograms. The combined use of these techniques enables the in vivo detection of approximately 100 nM of dopamine with a signal-to-noise ratio of 25.

Animals↗

Temporally resolved catecholamine spikes correspond to single vesicle release from individual chromaffin cells.

Secretion of catecholamines from single bovine chromaffin cells in culture was elicited by brief pressure ejections from a micropipette containing nicotine, carbamoylcholine, or potassium ions or by mechanical stimulation. Release was monitored electrochemically with a carbon-fiber microelectrode placed adjacent to the cell. Cyclic voltammetry was used to identify secreted species, whereas constant potential amperometry was used for improved temporal resolution (millisecond range) of catecholamine detection. During secretion, brief current spikes were observed, which were shown to be due to detection of catecholamines by electrooxidation. The spikes have the physical characteristics of multimolecular packets of catecholamines released at random times and locations from the surface of the single cell. The half-width of the spikes was found to increase with an increase in cell-electrode spacing. The properties of the catecholamine spikes correlate well with expectations based on secretion from individual storage vesicles. Spikes do not occur in the absence of Ca2+ in the buffer, and the majority of spikes are found to be distributed between 0.2 and 2 picocoulombs, corresponding to 1-10 attomoles of catecholamine detected. The frequency of the spikes increases with the intensity of the stimulus, but the average quantity of catecholamine in each spike is independent of the stimulus. Thus, these measurements represent time-resolved observation of quantal secretion of catecholamines and provide direct evidence for the exocytotic hypothesis.

Adrenal Medulla↗

Elective versus emergency cesarean hysterectomy cases in a residency program setting: a review of 129 cases from 1984 to 1988.

A retrospective study was performed to compare elective versus emergency cesarean hysterectomy in a residency program. We noted the following statistically significant differences between emergency and elective cases: (1) Estimated blood loss (mean +/- SD) for emergency and elective cases was significantly different at 1495 +/- 772 and 875 +/- 396 ml (p = 0.001). (2) Operative time in emergency cases was significantly longer than in elective cases (105 +/- 38 vs 83 +/- 27 minutes, p = 0.003). (3) The incidence of transfusion was 68% in our emergency cases and 14.6% in the elective series (p less than 0.05). (4) Febrile morbidity in our series was 40% in emergency cases and 18.3% in elective cases (p less than 0.05). Our series was comparable to previous series reported. Our experience suggests that cesarean hysterectomy can be performed safely in a residency training program when done as an elective procedure in the well-prepared patient.

Adult↗

Microcolumn separations and the analysis of single cells.

Capillary zone electrophoresis and open tubular liquid chromatography are two examples of an emerging area of analytical instrumentation known as microcolumn separations. The high resolution and small sample requirements of these methods make them suitable for the quantitative, multicomponent chemical analysis of single cells. Appropriate instrumentation for the analysis of nanoliter and subnanoliter samples is discussed. Data from the analysis of individual neurons are presented, including amino acid and neurotransmitter content.

Amino Acids↗

Quantitative analysis of individual neurons by open tubular liquid chromatography with voltammetric detection.

The ability to analyze individual cells is often important in biology because of the heterogeneity of tissue; this is especially true in the area of neurobiology. A method is described for the determination of trace levels of organic compounds in individual cells by open tubular liquid chromatography with voltammetric detection. In the method, a cell is isolated, an internal standard is added, the cell is homogenized and centrifuged, and the supernatant is injected directly onto the chromatography column. Since data are collected in both the electrochemical and chromatographic domains, the resolution of the method is better than that obtained by using amperometric detection. The combination of voltammetry and chromatography also aids in the identification of compounds. By use of this method three different neurons, D2, E4, and F1, from the land snail Helix aspersa are analyzed. The data show that the cells give certain unique and repeatable chemical profiles. Dopamine, serotonin, tyrosine, and tryptophan were identified and quantified in two of the cells at the femtomole level. In the third cell, only the two amino acids were observed and measured. The quantitative data indicate that the method is at least as reliable as other methods that have been applied to single cells and considerably more sensitive. The combination of qualitative and quantitative information allows for the chemical mapping of cells.

Animals↗

Secretion from islets and single islet cells following cryopreservation.

The ability to cryopreserve pancreatic islets has allowed the development of low-temperature banks that permit pooling of islets from multiple donors and allows time for sterility and viability testing. However, previous studies have shown that during cryopreservation and thawing there is a loss of islet mass and a reduction in islet function. The aim of this study was to measure and compare insulin secretion from cultured nonfrozen and frozen-thawed canine islets and beta-cells. Canine islets were isolated from mongrel dogs using intraductal collagenase distention, mechanical dissociation, and EuroFicoll purification. One group of purified islets was cultured overnight before dissociation into single cells and subsequent analysis. Remaining islets were cultured overnight (22 degrees C) and then cryopreserved in 2 M dimethyl sulfoxide (DMSO) solution using a slow stepwise addition protocol with slow cooling to -40 degrees C before storage in liquid nitrogen (-196 degrees C). Frozen islets were rapidly thawed (200 degrees C/min) and the DMSO removed using a sucrose dilution. From a series of seven consecutive canine islet isolations, islet recovery following postcryopreservation tissue culture was 81.5 +/- 4.8% compared to precryopreservation counts. In vitro islet function was equivalent between cultured nonfrozen and frozen-thawed islets with a calculated stimulation index of 10.4 +/- 1.5 (mean +/- SEM) for the frozen-thawed islets, compared with 12.4 +/- 1.2 for the cultured nonfrozen controls (p = ns, n = 7 paired experiments). Amperometric detection of secretion from single beta-cells in vitro has the sensitivity and temporal resolution to detect single exocytotic events and allows secretion to be monitored from single beta-cells in real time. Secretion from single beta-cells elicited by chemical stimulation was detected using a carbon fiber microelectrode. The frequency of exocytosis events was equivalent between the cultured nonfrozen and frozen-thawed beta-cells with an average of 7.0 +/- 1.32 events per stimulation for the cultured nonfrozen group compared with 6.0 +/- 1.45 events from the frozen then thawed preparations (minimum of 10 cells per run per paired experiment, p = ns) following stimulation with tolbutamide. The average amount of insulin released per individual exocytosis event was equivalent for the cultured nonfrozen and frozen-thawed islets. In addition, beta-cells responded to both tolbutamide and muscarinic stimulation following cryopreservation. It was determined that beta-cells recovered following cryopreservation are capable of secreting insulin at levels and frequencies comparable to those of cultured nonfrozen islet preparations.

Animals↗