[Diprosopus triophthalmus. From ancient terracotta sculptures to spiral computer tomographic reconstruction].

A still-born male fetus from the 19th century, fixed in formalin and presenting as diprosopia triophthalmica, was analysed by helical computer tomography and virtually reconstructed without damage. This rare, incomplete, symmetrical duplication of the face on a single head with three eyes, two noses and two mouths develops in the first 3 weeks of gestation and is a subset of the category of conjoined twins with unknown underlying etiology. Spiral computer tomography of fixed tissue demonstrated in the more than 100 year old specimen that virtual reconstruction can be performed in nearly the same way as in patients (contrast medium application not possible). The radiological reconstruction of the Munich fetus, here confined to head and neck data, is the basis for comparison with a number of imaging procedures of the last 3000 years. Starting with some Neolithic Mesoamerican ceramics, the "Pretty Ladies of Tlatilco", diprosopia triophthalmica was also depicted on engravings of the 16th and 17th century A.D. by artists as well as by the anatomist Soemmering and his engraver Berndt in the 18th century. Our modern spiral computer tomography confirms the ability of our ancestors to depict diprosopia triophthalmica in paintings and sculptures with a high level of natural precision.

Craniofacial Abnormalities↗

[Postsurgical computed tomography of uncemented hip arthroplasty].

PURPOSE: Presentation of the value of postsurgical computed tomography (CT) to diagnose loosening of uncemented femoral stems. MATERIALS AND METHODS: Incremental CT and spiral CT were performed on six femora with implanted uncemented stems after the entire femora were embedded in polymethylmethacrylate. The femora were subsequently sectioned (thickness 1 mm, separation 8 mm) and the medial and lateral contact areas of the prosthetic stem compared with the CT data. RESULTS: The CT showed a contact of femoral stem and cortical bone between 0.4 mm (3.4 %) and 4.8 mm (47.1 %) and the section specimens between 0.9 mm (8.7 %) and 3.4 mm (36.7 %). No correlation was found between the results (r = 0.61), since the individual differences were up to 24 % in almost all sections. CONCLUSIONS: Neither single-slice nor two-slice CT is capable of demonstrating the direct bone-endoprosthesis contact. Multidetector row CT (MDCT) is conceivably more accurate to measure the cortical contact of the femoral stem.

Arthroplasty, Replacement, Hip↗

Virtual intra-arterial angioscopy (VIA) of the carotid artery based on helical CT data.

The purpose of this study was to visualize both the vessel wall and atherosclerotic plaques in virtual intra-arterial angioscopy (VIA) based on helical CT data sets. To achieve this in vitro, the optimal reconstruction threshold of the vessel wall was determined to be 56.4% of the maximum enhancement. Using this threshold, 20 patients suffering from symptomatic carotid disease were examined in a helical CT scanner. The degree of stenosis was defined using the North American Symptomatic Endarterectomy Trial (NASCET) criteria and compared with results from digital substraction angiography (DSA). Grading of stenoses was only possible by adding the separately computed plaque geometry to the geometry of the vessel wall in a second step. Correlation between VIA and DSA in low grade, medium grade and high grade stenosis was 88%, 93% and 71%, respectively. Complete occlusions were diagnosed correctly in all patients. Sensitivity and specificity for the correct diagnosis of high grade stenosis was 93.7% and 91.3%, respectively. A realistic depiction of intraluminal structures in carotid arteries can only be generated by displaying both the vessel wall and plaque structures simultaneously.

Aged↗

Is a preoperative multidiagnostic approach to predict surgical resectability of periampullary tumors still effective?

BACKGROUND: Multimodality staging is recommended in patients with periampullary tumors to optimize preoperative determination of resectability. We investigated the potency of currently used diagnostic procedures in order to determine resectability. METHODS: Ninety-five consecutive patients with periampullary tumors prehospitally staged resectable underwent preoperative diagnostic tests: helical-computed tomography (CT) with maximum intensity projection of arterial vessels (MIP), magnetic resonance imaging (MRI), magnetic resonance cholangiopancreaticography (MRCP), endoscopic ultrasonography (EUS), endoscopic retrograde cholangiopancreaticography (ERCP), digital subtraction angiography (DSA), and positron emission tomography (PET). Diagnoses were verified by surgery and histopathology. RESULTS: In 45 patients with benign and 50 patients with malignant periampullary tumors sensitivity for tumor diagnosis was 89% to 96% in CT, MRI, EUS, and PET. Small tumors were best diagnosed by EUS (100%). Diagnosis of malignancy was made with 85% (EUS), 83% (CT), 82% (PET), and 72% (MRI) accuracy. Arterial vessel infiltration was best predicted by CT/MIP with an accuracy of 85%. For venous vessel infiltration MRI reached 85% accuracy. Accuracy rates for local nonresectability were 93% (EUS), 92% (MRI), and 90% (CT). Two and 4 of 8 patients with distant metastases were identified by CT and PET, respectively. The correct diagnosis of malignancy and determination of resectability was made by CT in 71% and by MRI in 70%. Biliary stenting reduced accuracy of CT diagnosis of malignancy from 88% to 73%. CONCLUSIONS: CT obtained before stenting was the single most useful test, providing correct diagnosis in 88% and resectability in 71% of patients. If no tumor is depicted in CT, EUS should be added. Uncertain venous vessel infiltration can be verified by MRI or EUS. Angiography should no longer be a routine diagnostic procedure. Equivocal tumors or possible metastasis may be further examined with PET.

Ampulla of Vater↗

Endoleaks after endovascular repair of aortic aneurysm: are they predictable?-initial results.

PURPOSE: To evaluate the predictability of endoleak. MATERIALS AND METHODS: Thirteen women and 60 men (mean age, 69.8 years) underwent transfemoral insertion of endoluminal stent-grafts for treatment of aortic aneurysms. Follow-up included helical computed tomography (CT) at 3-month intervals. In the cases of endoleak, angiography also was performed to document the number of leak sites, their size and position, the feeding artery, the size of the aneurysm, the amount of thrombus, and the visualization of the lumbar arteries and inferior mesenteric artery. These data were correlated (Student t test) with the probability of endoleak. RESULTS: A total of seven (10%) endoleaks were identified at CT in 68 patients. The feeding vessels were lumbar arteries in three cases, the inferior mesenteric artery in three cases, and the median sacral artery in one case. Of all factors, only the number of lumbar arteries visualized preoperatively (P <.005) had a significant correlation with probability of endoleak. In 71% (five of seven patients) of the cases of lumbar endoleak, four lumbar arteries were patent, whereas among the 61 patients with successfully repaired aneurysm, only eight (13%) had four patent lumbar arteries. Endoleaks were never found in the primarily thrombosed sections of an aneurysm. CONCLUSION: Prediction of endoleaks with absolute certainty remains elusive. The single correlating risk factor identified from the data was patency of four or more lumbar arteries visualized preoperatively at CT.

Aged↗

Virtual endoscopy of the nasal cavity in comparison with fiberoptic endoscopy.

PURPOSE: To apply virtual-endoscopic mode to display the nasal cavity and to evaluate clinical application of virtual endoscopy in comparison with nasal fiberoptic endoscopy. MATERIALS AND METHODS: Eleven patients were examined by virtual endoscopy after axial spiral computed tomography (CT) scanning was performed. In addition, 9 out of these 11 patients underwent fiberoptic endoscopy. Spiral CT scanning was performed with 1-mm collimation, 0.5- to 1-mm increment, 25-250 mA s, and pitch 1-2. Virtual endoscopy was performed by Explorer software package. RESULTS: Virtual endoscopy could clearly demonstrate anatomic structures in the nasal cavity, septal deviation, stenosis and obstruction of the middle meatus, turbinate hyperplasia, and pathological masses larger than 3 mm in diameter. However, "false adhesions" may appear in virtual endoscopy. The main limitation of virtual endoscopy was the inability to evaluate mucosa and its surface. CONCLUSION: Virtual endoscopy of the nasal cavity is a new and noninvasive method. It can demonstrate normal and pathological structures in the nasal cavity. Its ability to visualize is comparable with fiberoptic endoscopy except for evaluating mucosal surface and secretions. In the future, this method will probably be a basic instrument of computer-assisted surgery in the midfacial region.

Adult↗

Vertebral body replacement with a bioglass-polyurethane composite in spine metastases--clinical, radiological and biomechanical results.

Metastatic spine lesions frequently require corpectomy in order to achieve decompression of the spinal cord and restoration of spinal stability. A variety of systems have been developed for vertebral body replacement. In patients with prolonged life expectancy due to an improvement of both systemic and local therapy, treatment results can be impaired by a loosening at the implant-bone interface or mechanical failure. Furthermore, early detection of a metastatic recurrence using sensitive imaging modalities like computed tomography (CT) and magnetic resonance imaging (MRI) is possible in these patients without artefact interference. The aim of our pilot study was to evaluate the clinical applicability and results of a new radiolucent system for vertebral body replacement in the lumbar spine. The system consists of bone-integrating biocompatible materials - a polyetherurethane/bioglass composite (PU-C) replacement body and an integrated plate of carbon-fibre reinforced polyetheretherketone (CF-PEEK) - and provides high primary stability with anterior instrumentation alone. In a current prospective study, five patients with metastatic lesions of the lumbar spine were treated by corpectomy and reconstruction using this new system. Good primary stability was achieved in all cases. Follow-up (median 15 months) using CT and MRI revealed progressive osseous integration of the PU-C spacer in four patients surviving more than 6 months. Results obtained from imaging methods were confirmed following autopsy by biomechanical investigation of an explanted device. From these data, it can be concluded that implantation of the new radiolucent system provides sufficient long-term stability for the requirements of selected tumour patients with improved prognosis.

Adult↗

Treatment of leaks after endovascular repair of aortic aneurysms.

PURPOSE: To evaluate leaks after the endovascular repair of aortic aneurysms and treat them with occlusive therapy. MATERIALS AND METHODS: Seventy patients (11 women, 59 men), aged 26-82 years (mean, 69.2 years), underwent transfemoral insertion of endoluminal stent-grafts for treatment of aortic aneurysms. Indications were traumatic pseudoaneurysms (n = 5) or arteriosclerotic aneurysms (n = 65). Aneurysms were thoracic (n = 5) or infrarenal (n = 65). To exclude the possibility of leaks, spiral computed tomography (CT) was performed at 3-month intervals. Patients with leaks that persisted unchanged longer than 3 months were referred for angiography and occlusive therapy. RESULTS: At CT, 21 leaks were identified in 17 of 70 patients (24%). Only 11 of those 17 patients (65%) had leaks identified with conventional aortography. Selective angiography, however, depicted all of these. Eighteen of 21 leaks proved amenable to occlusive treatment: surgery (n = 1), further stent implantation (n = 4), or embolization (n = 13). In one leak, spontaneous occlusion occurred after 3 months. Two leaks in either the iliolumbar or the median sacral artery were inaccessible; one remained untreated, and the other was unsuccessfully treated. Mean follow-up of occlusive therapy was 6.8 months (range, 2-14 months). CONCLUSION: Successful occlusion of perigraft leaks is feasible in most cases and can be performed without major complications.

Adult↗

CT and arteriography in the evaluation of indirect myocardial revascularization with a free-muscle transplant: initial experience.

PURPOSE: To examine patients with advanced cardiovascular disease with radiology after indirect myocardial revascularization with a free-skeletal-muscle transplant and to determine whether the attached vessel remains patent over the middle and long terms. MATERIALS AND METHODS: In 10 patients with advanced, inoperable cardiovascular disease treated with indirect myocardial revascularization with a free-muscle transplant, radiologic follow-up was performed postoperatively and every 6 months. All 10 patients underwent selective arteriography of the anastomosed vessel and contrast material-enhanced helical computed tomography (CT) (transverse sections and reconstructions). RESULTS: All patients showed adequate vascular conditions postoperatively, as did nine of 10 patients after 1 year. In one patient, the anastomosed artery was occluded. CT showed time-dependent muscle degeneration in all patients. Postoperative, contrast-enhanced, superselective CT showed an area of high-attenuating uptake in the muscle transplant in all patients. After 1 year, CT depicted perfusion defects of the skeletal muscle in two patients. In eight patients, however, small vascular bridges from the skeletal muscle to the myocardium were detected. Radiologic results correlated well with clinical outcome and stress electrocardiograms. CONCLUSION: Helical intraarterial CT and arteriography were sensitive in depicting enhancement and remaining vital function in nine of 10 patients after indirect myocardial revascularization with a free-muscle transplant. This combination seems promising for postoperative examination in such patients.

Aged↗

Malpositioned or dislocated aortic endoprostheses: repositioning using percutaneous pull-down maneuvers.

PURPOSE: To present the capabilities and potential complications of 2 percutaneous techniques for repositioning malpositioned or dislodged aortic endografts. METHODS: Seven male patients (median age 67.9 years, range 59 to 78) required correction of misplaced or dislocated endografts in the thoracic (n = 1) or infrarenal abdominal aorta (n = 6). In 1 patient, an infrarenal bifurcated stent-graft was mistakenly deployed across a renal artery; repositioning was accomplished by tugging caudally on a guidewire placed across the endograft bifurcation and exteriorized from both femoral arteries. An inflated balloon catheter was used to reposition 3 dislocated aortic devices (1 thoracic, 2 infrarenal) and 3 iliac graft limbs that had disconnected from the main graft body 6 to 12 months after implantation. RESULTS: Repositioning maneuvers were successful in all cases, with the devices being moved from 5 to 27 mm (median 7.8 mm). There were no procedure-related complications. CONCLUSIONS: Nonsurgical repositioning of misplaced aortic prostheses is technically feasible in individual cases. The risk associated with the procedure, however, cannot yet be evaluated.

Aged↗

Embolization of type II endoleaks fed by the inferior mesenteric artery: using the superior mesenteric artery approach.

PURPOSE: To evaluate the use of a superior mesenteric artery (SMA) approach to embolize type II endoleaks arising from the inferior mesenteric artery (IMA). TECHNIQUE: When reperfusion of the aneurysmal sac via the SMA occurs through the IMA, as shown by computed tomography (CT) and angiography, the IMA origin can be accessed via the marginal artery or the anastomosis of Riolan. The SMA is catheterized with a 5-F catheter, and a coaxial catheter is advanced to the leak to deliver 2- to 8-mm-diameter minicoils to embolize the IMA origin and entire aneurysmal sac. Embolization usually requires from 1 to 2 hours to complete. In our experience with this technique in 11 cases, complications have not occurred, and there has been only one very small residual leak that sealed the next day. Over a 24.5-month follow-up (range 12-39), the endoleaks have remained sealed according to serial color duplex scans. CONCLUSIONS: Successful percutaneous treatment of type II endoleak due to IMA inflow can be accomplished using an SMA access via the Riolan anastomosis or marginal artery. The procedure appears to be safe and has no adverse effects.

Aged↗

Angiography of leaks after endovascular repair of infrarenal aortic aneurysms.

OBJECTIVE: We examined whether leaks that persist after stent grafting are associated with outflow arteries. SUBJECTS AND METHODS: Selective angiography was performed in 21 patients with persistent leaks after undergoing endovascular repair of infrarenal aneurysms of the abdominal aorta. Late leaks occurred in five patients whose prostheses were originally sealed. Before angiography, the size and position of leaks were determined with CT and color Doppler sonography. RESULTS: Superselective angiography was successful in 19 of 21 patients. In two patients, angiography was performed over the afferent artery supplying the leak. We found one outflow artery at the site of the leak in 10 patients (47%); two outflow arteries in five (23.8%); and as many as five outflow arteries in three (14%). Angiography overlooked outflow arteries in three patients (14%). The lumbar and inferior mesenteric, urethral, and testicular arteries were identified as outflow arteries. CONCLUSION: Other than feeder arteries, persistent leaks are associated with outflow vessels that contribute to the patency of leaks.

Adult↗

[Interventional treatment of hemorrhages in advanced cervical carcinoma].

PURPOSE: Retrospective evaluation of percutaneous interventional treatment of locally advanced cervical carcinoma. MATERIALS AND METHODS: Since 1991, 13 patients with advanced tumor disease have been referred to our department for diagnosis and therapy of an acute blood loss. In all patients (age 40-88 years, mean 61 years) hemorrhage was detected by decrease in red blood cell count. In all cases patients suffered from locally advanced or recurrent disease after surgery and/or additional radio- or chemotherapy. Embolization was performed by transfemoral access using minicoils in most cases, liquid agents less often and a covered vascular stent in one patient. RESULTS: The site of the hemorrhage or the blood pooling of the tumor could be seen in all cases angiographically. Twenty-seven treatment cycles (2.1 per patient) were performed at intervals of 3 days to 6 months. The maximum time of follow-up and additional treatments if necessary was 1 year. In 9 of 13 patients (69%) the bleeding could be stopped immediately with a single treatment or initial treatment via both iliac arteries. One patient (7,7%) died during therapy because of an uncontrollable bleeding and consecutive decrease in red blood cells count. The remaining three patients (23%) showed slight persistent or recurrent bleeding, which could be managed interventionally until the following episode. There were two complications (15%) during therapy, representing a coil misplacement and a coil wash-out, which both could be managed interventionally. CONCLUSION: Hemorrhage following locally advanced or recurrent cervical carcinoma can be stopped interventionally in about 70% of cases. Even in partial success it is possible to manage the acute life-threatening situation. Follow-up examinations of up to 1 year justify this therapeutic concept.

Adult↗

Non-operative management of arterial liver hemorrhages.

A retrospective evaluation of embolotherapy in patients with arterial liver hemorrhages was carried out. Twenty-six patients, ranging in age from 10 days to 77 years with active arterial liver hemorrhages, underwent non-surgical embolotherapy. Bleeding was attributed to trauma (n = 21), tumor (n = 3), pancreatitis (n = 1), or unknown cause (n = 1). Twenty-nine embolizations were performed via a transfemoral (n = 26) or biliary (n = 2) approach. One bare Wallstent was placed into the common hepatic artery via to an axillary route to cover a false aneurysm due to pancreatitis. Treatment was controlled in 4 patients by cholangioscopy (n = 2) or by intravascular ultrasound (n = 2). Prior surgery had failed in 3 patients. Intervention controlled the hemorrhage in 24 of 26 (92%) patients within 24 h. Embolotherapy failed in 1 patient with pancreatic carcinoma and occlusion of the portal vein. In 1 patient with an aneurysm of the hepatic artery treated by Wallstent insertion, total occlusion was not achieved in the following days, as demonstrated by CT and angiography. However, colour Doppler flow examination showed no flow in the aneurysm 6 months later. Complications were one liver abscess, treated successfully by percutaneous drainage for 10 days, and one gallbladder necrosis after superselective embolization of the cystic artery. Embolization is a effective tool with a low complication rate in the treatment of liver artery hemorrhage, even in patients in whom surgery has failed.

Adolescent↗

Pancreas: does hyoscyamine butylbromide increase the diagnostic value of helical CT?

Among 50 patients referred for helical computed tomography (CT) of the pancreas, 24 randomly selected patients received 40 mg of hyoscyamine butylbromide to evaluate whether its administration improved image quality and diagnostic findings. Differences between the groups were not statistically significant. It was therefore concluded that hyoscyamine butylbromide does not contribute a diagnostic advantage at helical CT of the pancreas.

Adult↗

Leakages after endovascular repair of aortic aneurysms: classification based on findings at CT, angiography, and radiography.

PURPOSE: To ascertain whether the configuration and location of leakages identified at computed tomography (CT) could provide evidence of their angiographically and fluoroscopically confirmed causes. MATERIALS AND METHODS: Fifty patients aged 26-79 years underwent endovascular repair of traumatic (n = 4) or arteriosclerotic (n = 46) aortic aneurysms (four thoracic, 46 infrarenal). Radiographic examinations in three planes and helical CT were performed 1 week after implantation and every 3 months thereafter. Angiography was performed when there was evidence of a leakage at CT. RESULTS: CT demonstrated evidence of leakages in 13 patients. Broad-based leakages immediately adjacent to the prosthesis were termed "perigraft leakages." If the area most affected by the leakage lay along the border of the aneurysm, then retrograde leakages were apparent at angiography. If the leakage was ventral to the prosthesis, then its source was the inferior mesenteric artery; if it was dorsolateral, then it was supplied by either the lumbar arteries or the median sacral artery through the hypogastric artery. One circumferential leakage could not be evaluated adequately at CT or angiography. Radiography depicted a rupture of the stent mesh in the middle of the prosthesis. Selective angiography demonstrated all types of leakages and permitted CT classification. CONCLUSION: The cause of a leakage can be determined with CT on the basis of its configuration and location in the majority of cases.

Adult↗

Endovascular repair of aortic aneurysms: treatment of complications.

PURPOSE: To evaluate the use of interventional procedures for treating complications following endovascular repair of aortic aneurysms. METHODS: Fifty-five patients (49 men; mean age 67.5 years) underwent endoluminal stent-graft repair of traumatic (n = 4) or arteriosclerotic (n = 51) aortic aneurysms in the thoracic (n = 3) or infrarenal (n = 52) aorta. Follow-up of therapeutic success included periodic clinical examination, angiography, and spiral computed tomography. RESULTS: Discounting the 25 (45%) cases of postimplantation syndrome that did not require treatment, there were 22 complications observed in 20 (36%) patients over a mean 10-month follow-up (range 1 to 27). There were 2 transrenal endograft maldeployments, 1 case of twisted graft limbs, 2 access site problems (1 patient), 12 endoleaks (11 patients), 1 late graft limb thrombosis, 1 symptomatic internal iliac artery occlusion, 2 myocardial infarctions, and 1 transient psychosis. Seven (13%) patients did not undergo specific therapy, while 4 (7%) required operation (2 crossover bypass grafts, 1 suture revision, and 1 graft replacement). Among 9 (16%) patients treated with interventional techniques, 7 underwent percutaneous coil embolization for 8 endoleaks (7 successfully resolved). One late stent-graft disconnection required an additional stent-graft, and 1 of the 2 malpositioned endografts was repositioned. All patients remain alive with no increase in the diameter of the aneurysm in any patient. CONCLUSIONS: Technical problems resulting from the endovascular repair of aortic aneurysms often respond to interventional treatment.

Adult↗