Visualizing lung function with positron emission tomography.

Positron emission tomography (PET) provides three-dimensional images of the distributions of radionuclides that have been inhaled or injected into the lungs. By using radionuclides with short half-lives, the radiation exposure of the subject can be kept small. By following the evolution of the distributions of radionuclides in gases or compounds that participate in lung function, information about such diverse lung functions as regional ventilation, perfusion, shunt, gas fraction, capillary permeability, inflammation, and gene expression can be inferred. Thus PET has the potential to provide information about the links between cellular function and whole lung function in vivo. In this paper, recent advancements in PET methodology and techniques and information about lung function that have been obtained with these techniques are reviewed.

Animals↗

Regional pulmonary perfusion, inflation, and ventilation defects in bronchoconstricted patients with asthma.

RATIONALE: Bronchoconstriction in asthma leads to heterogeneous ventilation and the formation of large and contiguous ventilation defects in the lungs. However, the regional adaptations of pulmonary perfusion (Q) to such ventilation defects have not been well studied. METHODS: We used positron emission tomography to assess the intrapulmonary kinetics of intravenously infused tracer nitrogen-13 ((13)NN), and measured the regional distributions of ventilation and perfusion in 11 patients with mild asthma. For each subject, the regional washout kinetics of (13)NN before and during methacholine-induced bronchoconstriction were analyzed. Two regions of interest (ROIs) were defined: one over a spatially contiguous area of high tracer retention (TR) during bronchoconstriction and a second one covering an area of similar size, showing minimal tracer retention (NR). RESULTS: Both ROIs demonstrated heterogeneous washout kinetics, which could be described by a two-compartment model with fast and slow washout rates. We found a systematic reduction in regional Q to the TR ROI during bronchoconstriction and a variable and nonsignificant change in relative Q for NR regions. The reduction in regional Q was associated with an increase in regional gas content of the TR ROI, but its magnitude was greater than that anticipated solely by the change in regional lung inflation. CONCLUSION: During methacholine-induced bronchoconstriction, perfusion to ventilation defects are systematically reduced by a relative increase in regional pulmonary vascular resistance.

Adult↗

Mechanical ventilation and air leaks after lung biopsy for acute respiratory distress syndrome.

BACKGROUND: Open lung biopsy in acute respiratory distress syndrome (ARDS) may provide a specific etiology and change clinical management, yet concerns about complications remain. Persistent air leak is the most common postoperative complication. Risk factors in this setting are not known. METHODS: We performed a retrospective analysis of 53 patients who underwent open lung biopsy for clinical ARDS (based on American European Consensus Conference criteria) between 1989 and 2000. RESULTS: Sixteen patients (30.2%) developed an air leak lasting more than 7 days or died with an air leak. Univariate analyses showed no significant correlation with age, gender, sex, corticosteroid use, diabetes, immunocompromised status, or pathologic diagnosis. A lower risk of air leak was associated with lower peak airway pressure and tidal volume, use of pressure-cycled ventilation, and use of an endoscopic stapling device. In multivariate analyses, only peak airway pressure remained a significant predictor. The risk of prolonged air leak was reduced by 42% (95% confidence interval [CI: 17% to 60%]) for every 5 cm H2O reduction in peak airway pressure. CONCLUSIONS: The use of a lung-protective ventilatory strategy that limits peak airway pressures is strongly associated with a reduced risk of postoperative air leak after open lung biopsy in ARDS. Using such a strategy may allow physicians to obtain information from open lung biopsy to make therapeutic decisions without undue harm to ARDS patients.

Adult↗

The impact of endotracheal suctioning on gas exchange and hemodynamics during lung-protective ventilation in acute respiratory distress syndrome.

OBJECTIVE: To evaluate the respiratory and hemodynamic effects of open suctioning (OS) versus closed suctioning (CS) during pressure-control (PC) and volume-control (VC) ventilation, using a lung-protective ventilation strategy in an animal model of acute respiratory distress syndrome (ARDS). SETTING: Animal laboratory in a university hospital. DESIGN: Randomized cross-over evaluation. ANIMALS: Eight female Dorset sheep. INTERVENTIONS: Lung lavage was used to simulate ARDS. We applied VC and PC mechanical ventilation with a tidal volume of 6 mL/kg and positive end-expiratory pressure (PEEP), adjusted based on a table of PEEP versus fraction of inspired oxygen (FIO2). Suctioning was performed for 10 s with a suction pressure of -100 mm Hg, during both OS and CS. OS and CS were randomly performed with each animal. Hemodynamics and arterial blood gases were recorded before, during, and after endotracheal suctioning. RESULTS: The PaO2/FIO2 ratios before suctioning were similar in all groups, as were the PEEP and FIO2. PaO2/FIO2 was lower after OS than after CS/VC or CS/PC. There was no post-suctioning difference in oxygenation between CS/VC and CS/PC. PaCO2 recorded 10 min after suctioning was greater than the presuctioning value, in all groups. Intrapulmonary shunt fraction increased between baseline and 10 min post-suctioning with OS and CS/VC, but did not significantly increase with CS/PC. There were no significant changes in hemodynamics pre-suctioning versus post-suctioning with OS, CS/VC, or CS/PC. CONCLUSION: PaO2/FIO2) was better maintained during CS with both VC and PC modes during lung-protective ventilation for ARDS, as compared with OS, and shunt fraction post-suctioning changed least with PC.

Animals↗

Identifying airways responsible for heterogeneous ventilation and mechanical dysfunction in asthma: an image functional modeling approach.

We present an image functional modeling approach, which synthesizes imaging and mechanical data with anatomically explicit computational models. This approach is utilized to identify the relative importance of small and large airways in the simultaneous deterioration of mechanical function and ventilation in asthma. Positron emission tomographic (PET) images provide the spatial distribution and relative extent of ventilation defects in asthmatic subjects postbronchoconstriction. We also measured lung resistance and elastance from 0.15 to 8 Hz. The first step in image functional modeling involves mapping ventilation three-dimensional images to the computational model and identifying the largest sized airways of the model that, if selectively constricted, could precisely match the size and anatomic location of ventilation defects imaged by PET. In data from six asthmatic subjects, these airways had diameters <2.39 mm and mostly <0.44 mm. After isolating and effectively closing airways in the model associated with these ventilation defects, we imposed constriction with various means and standard deviations to the remaining airways to match the measured lung resistance and elastance from the same subject. Our results show that matching both the degree of mechanical impairment and the size and location of the PET ventilation defects requires either constriction of airways <2.4 mm alone, or a simultaneous constriction of small and large airways, but not just large airways alone. Also, whereas larger airway constriction may contribute to mechanical dysfunction during asthma, degradation in ventilation function requires heterogeneous distribution of near closures confined to small airways.

Adult↗

Effect of prone position on regional shunt, aeration, and perfusion in experimental acute lung injury.

RATIONALE: The prone position is used to improve gas exchange in patients with acute respiratory distress syndrome. However, the regional mechanism by which the prone position improves gas exchange in acutely injured lungs is still incompletely defined. METHODS: We used positron emission tomography imaging of [(13)N]nitrogen to assess the regional distribution of pulmonary shunt, aeration, perfusion, and ventilation in seven surfactant-depleted sheep in supine and prone positions. RESULTS: In the supine position, the dorsal lung regions had a high shunt fraction, high perfusion, and poor aeration. The prone position was associated with an increase in lung gas content and with a more uniform distribution of aeration, as the increase in aeration in dorsal lung regions was not offset by loss of aeration in ventral regions. Consequently, the shunt fraction decreased in dorsal regions in the prone position without a concomitant impairment of gas exchange in ventral regions, thus leading to a significant increase in the fraction of pulmonary perfusion participating in gas exchange. In addition, the vertical distribution of specific alveolar ventilation became more uniform in the prone position. A biphasic relation between regional shunt fraction and gas fraction showed low shunt for values of gas fraction higher than a threshold, and a steep linear increase in shunt for lower values of gas fraction. CONCLUSION: In a surfactant-deficient model of lung injury, the prone position improved gas exchange by restoring aeration and decreasing shunt while preserving perfusion in dorsal lung regions, and by making the distribution of ventilation more uniform.

Animals↗

Self-organized patchiness in asthma as a prelude to catastrophic shifts.

Asthma is a common disease affecting an increasing number of children throughout the world. In asthma, pulmonary airways narrow in response to contraction of surrounding smooth muscle. The precise nature of functional changes during an acute asthma attack is unclear. The tree structure of the pulmonary airways has been linked to complex behaviour in sudden airway narrowing and avalanche-like reopening. Here we present experimental evidence that bronchoconstriction leads to patchiness in lung ventilation, as well as a computational model that provides interpretation of the experimental data. Using positron emission tomography, we observe that bronchoconstricted asthmatics develop regions of poorly ventilated lung. Using the computational model we show that, even for uniform smooth muscle activation of a symmetric bronchial tree, the presence of minimal heterogeneity breaks the symmetry and leads to large clusters of poorly ventilated lung units. These clusters are generated by interaction of short- and long-range feedback mechanisms, which lead to catastrophic shifts similar to those linked to self-organized patchiness in nature. This work might have implications for the treatment of asthma, and might provide a model for studying diseases of other distributed organs.

Asthma↗

Topographic basis of bimodal ventilation-perfusion distributions during bronchoconstriction in sheep.

The distribution of ventilation-perfusion (VA/Q) ratios during bronchoconstriction measured with the multiple inert gases elimination technique is frequently bimodal. However, the topographic basis and the cause of that bimodality remain unknown. In this article, regional VA/Q is quantified by three-dimensional positron emission tomography (PET) imaging of methacholine-induced bronchoconstriction in sheep. Regional VA/Q ratios were calculated from the imaged kinetics of intravenously injected 13NN-saline bolus, assembled into global VA/Q distributions, and used to estimate gas exchange. During bronchoconstriction, large regions with impaired tracer washout were observed adjacent to regions of normal ventilation. PET-derived VA/Q distributions during bronchoconstriction were consistently bimodal, with areas of low VA/Q receiving a large fraction of Q. The standard deviation of the VA/Q distribution was 38% lower if small-scale (subresolution) heterogeneity (< 2.2 cm3) was ignored. Arterial blood gases predicted from PET data correlated well with measured values for Pa(O2) (r2= 0.91, p < 0.01) and Pa(CO2) (r2= 0.90, p < 0.01). We conclude that the bimodality of VA/Q distributions in bronchoconstriction reflects the involvement of large contiguous regions of hypoventilation with substantial subresolution intraregional VA/Q heterogeneity. Assessment of the subresolution VA/Q heterogeneity is therefore essential to accurately quantify global gas exchange impairment during bronchoconstriction.

Animals↗

Pressure-volume curves of the respiratory system.

The quasi-static pressure-volume (P-V) curve of the respiratory system describes the mechanical behavior of the lungs and chest wall during inflation and deflation. To eliminate resistive and convective acceleration effects, the measurement of volume and pressure must be performed during short periods of apnea or during very slow flow. There are 3 main techniques for acquiring quasi-static P-V curves: the supersyringe method, the constant flow method, and the multiple-occlusion (or ventilator) method. For the information to be interpreted correctly, one must understand the interaction between the lungs and the chest wall, the effects of the supine position, and the meaning of hysteresis. The P-V curve has been studied in many disease states, but it has been applied most extensively to patients with acute respiratory distress syndrome, in hopes that it might allow clinicians to customize ventilator settings according to a patient's individual respiratory mechanics and thus protect the patient from ventilator-induced lung injury. However, lack of standardization of the procedure used to acquire P-V curves, difficulties in measuring absolute lung volume, lack of knowledge regarding how to use the information, and a paucity of data showing a benefit in morbidity and mortality with the use of P-V curves have tempered early enthusiasm regarding the clinical usefulness of the quasi-static P-V curve.

Emphysema↗

Mechanism by which a sustained inflation can worsen oxygenation in acute lung injury.

BACKGROUND: Sustained lung inflations (recruitment maneuvers [RMs]) are occasionally used during mechanical ventilation of patients with acute lung injury to restore aeration to atelectatic alveoli. However, RMs do not improve, and may even worsen, gas exchange in a fraction of these patients. In this study, the authors sought to determine the mechanism by which an RM can impair gas exchange in acute lung injury. METHODS: The authors selected a model of acute lung injury that was unlikely to exhibit sustained recruitment in response to a lung inflation. In five sheep, lung injury was induced by lavage with 0.2% polysorbate 80 in saline. Positron emission tomography and [13N]nitrogen were used to assess regional lung function in dependent, middle, and nondependent lung regions. Physiologic data and positron emission scans were collected before and 5 min after a sustained inflation (continuous positive airway pressure of 50 cm H2O for 30 s). RESULTS: All animals showed greater loss of aeration and higher perfusion and shunting blood flow in the dependent region. After the RM, Pao2 decreased in all animals by 35 +/- 22 mmHg (P < 0.05). This decrease in Pao2 was associated with redistribution of pulmonary blood flow from the middle, more aerated region to the dependent, less aerated region (P < 0.05) and with an increase in the fraction of pulmonary blood flow that was shunted in the dependent region (P < 0.05). Neither respiratory compliance nor aeration of the dependent region improved after the RM. CONCLUSIONS: When a sustained inflation does not restore aeration to atelectatic regions, it can worsen oxygenation by increasing the fraction of pulmonary blood flow that is shunted in nonaerated regions.

Animals↗

Pulmonary artery occlusion increases the ratio of diffusing capacity for nitric oxide to carbon monoxide in prone sheep.

OBJECTIVE: To test the hypothesis that the ratio of diffusing capacity of the lung for nitric oxide (DLno) to diffusing capacity of the lung for carbon monoxide (DLco) would be affected by occlusion of a fraction of the pulmonary vascular bed. DESIGN: Interventional physiologic study. SETTING: Animal laboratory of a university hospital. SUBJECTS: Thirteen sheep. INTERVENTIONS: We simultaneously measured single-breath DLno and DLco in anesthetized and mechanically ventilated sheep (fraction of inspired oxygen [Fio(2)] of 1.0) before and after pulmonary artery occlusion by inflation of a balloon (n = 6), and by autologous clot embolism (n = 4). To see if the effect also occurred on Fio(2) of 0.21, four animals were studied during ventilation with room air, one of which was also in the Fio(2) of 1.0 group (14 total experiments with 13 sheep). RESULTS: On Fio(2) of 1.0, the mean DLno/Dlco ratio rose by 35% from 4.76 +/- 0.41 in control to 6.42 +/- 0.82 after balloon occlusion (p = 0.002), and by 54% from 7.55 +/- 2.09 to 11.6 +/- 2.61 (p = 0.005) after autologous clot embolism (+/- SD). An equivalent relative increase of 27% took place during ventilation with room air, but the DLno/DLco ratio was lower (3.14 +/- 0.22 in control and 3.98 +/- 0.38 after balloon occlusion). Independent of the method of obstruction or Fio(2), the increase in DLno/DLco ratio was mostly due to a drop in DLco. The DLno/Dlco ratio reduced much of the intersubject variability of either DLno or DLco alone. CONCLUSION: The DLno/DLco ratio increased after pulmonary artery occlusion regardless of the method of occlusion or Fio(2). This increase may be a result of a greater sensitivity of DLco than DLno to a regional reduction in capillary blood flow.

Animals↗

Quantification of regional ventilation-perfusion ratios with PET.

UNLABELLED: The topographic matching of alveolar ventilation (V(A)) and perfusion (Q) is the main determinant of gas exchange efficiency of the lung. However, no pulmonary functional imaging technique has been shown to predict whole-lung gas exchange in health and disease. This study aims to present a PET-based method to estimate regional alveolar ventilation-to-perfusion ratios (V(A)/Q) predictive of arterial blood gases. METHODS: The method is based on the regional tracer kinetics of (13)N-nitrogen ((13)NN) after an intravenous bolus injection during a breath-hold period and subsequent washout from the lungs with resumption of breathing. The method takes into account the presence of inter- and intraregional nonuniformities at length scales smaller than the imaging spatial resolution. An algorithm used regional tracer washout to classify regional V(A)Q/ uniformity. Intraregional V(A)/Q mismatch in nonuniform regions was described with a 2-compartment model. Regional V(A)/Q estimates were combined into a whole-lung distribution of V(A)/Q ratios and were used to compute global arterial blood gases. The method was applied to 3-dimensional PET data from anesthetized and mechanically ventilated sheep before and after methacholine bronchoconstriction (n = 3) and pulmonary embolism (n = 3) and after saline lung lavage (n = 3). RESULTS: PET images revealed regional changes in ventilation and perfusion consistent with the different disease models. Quantification of the images using PET-derived V(A)Q/ distributions showed unimodal and narrow distributions in control conditions that became wider and unimodal after pulmonary embolism and saline lung lavage and bimodal after bronchoconstriction. Images of regional gas exchange allowed for visualization of regional gas exchange. Arterial blood gases estimated from the PET-based V(A)/Q distributions closely agreed with measured values (partial pressure of oxygen, arterial [PaO(2)]: r(2) = 0.97, P < 0.001; partial pressure of carbon dioxide, arterial [PaCO(2)]: r(2) = 0.96, P < 0.001). CONCLUSION: Tracer kinetics analysis of PET images after an intravenous injection of (13)NN provides a quantitative assessment of regional V(A)/Q heterogeneity including that corresponding to length scales smaller than the spatial resolution of the imaging method. Quantification of V(A)/Q mismatch obtained with the presented technique is directly related to severity of gas exchange impairment as determined by arterial blood gases.

Algorithms↗

Changes in regional ventilation after autologous blood clot pulmonary embolism.

BACKGROUND: Previous studies have suggested that pulmonary embolism (PE) and pulmonary artery occlusion result in a shift in alveolar ventilation away from unperfused regions. This study aimed to directly assess changes in regional specific ventilation (sV(A)) due to autologous blood clot PE using positron emission tomography. METHODS: Pulmonary embolism was created in six anesthetized, paralyzed, and mechanically ventilated sheep by injecting cylindrical clots of autologous blood (7 mm in diameter and height). Clots were progressively infused into a central vein until a stable mean pulmonary artery pressure between 30 and 40 mmHg was achieved. A multislice positron emission tomography camera was used to image 15 contiguous, 6.5-mm-thick transverse cross-sections of the chest beginning just above the diaphragm. sV(A) from perfused regions (sV(A),(p)) was assessed as the ventilatory turnover rate of the tracer NN after central venous injection of NN-labeled saline. RESULTS: Pulmonary embolism obstructed flow to 64% of imaged areas. Before PE, (sV(A),(p))was equivalent in areas that would remain perfused and those that would become embolized after PE (0.021 +/- 0.007 0.021 +/- 0.006 s(-1); P = nonsignificant). After PE, sV(A),(p) of areas remaining perfused increased to 0.033 +/- 0.011 s (-1) (P < 0.005). This effect on regional sV(A),(p) could have been caused by active redistribution of sV(A),(p) or by a reduction in tracer concentration of perfused areas due to the dead space common to perfused and embolized regions. Model simulations indicated that the common dead-space effect could only explain a small part of the sV(A),(p) increase. CONCLUSIONS: An increase in sV(A),(p) of perfused regions occurs following PE with 7-mm autologous blood clots. This increase is most likely caused by a shift in ventilation away from embolized areas mediated by hypocapnic pneumoconstriction.

Algorithms↗

Regional VA, Q, and VA/Q during PLV: effects of nitroprusside and inhaled nitric oxide.

Partial liquid ventilation (PLV) with high-specific-weight perfluorocarbon liquids has been shown to improve oxygenation in acute lung injury, possibly by redistributing perfusion from dependent, injured regions to nondependent, less injured regions of the lung. Our hypothesis was that during PLV in normal lungs, a shift in perfusion away from dependent lung zones might, in part, be due to vasoconstriction that could be reversed by infusing sodium nitroprusside (NTP). In addition, delivering inhaled NO during PLV should improve gas exchange by further redistributing blood flow to well-ventilated lung regions. To examine this, we used a single transverse-slice positron emission tomography camera to image regional ventilation and perfusion at the level of the heart apex in six supine mechanically ventilated sheep during five conditions: control, PLV, PLV + NTP, and PLV + NO at 10 and 80 ppm. We found that PLV shifted perfusion from dependent to middle regions, and the dependent region demonstrated marked hypoventilation. The vertical distribution of perfusion changed little when high-dose intravenous NTP was added during PLV, and inhaled NO tended to shift perfusion toward better ventilated middle regions. We conclude that PLV shifts perfusion to the middle regions of the lung because of the high specific weight of perflubron rather than vasoconstriction.

Administration, Inhalation↗

Topographical distribution of pulmonary perfusion and ventilation, assessed by PET in supine and prone humans.

Using positron emission tomography (PET) and intravenously injected (13)N(2), we assessed the topographical distribution of pulmonary perfusion (Q) and ventilation (V) in six healthy, spontaneously breathing subjects in the supine and prone position. In this technique, the intrapulmonary distribution of (13)N(2), measured during a short apnea, is proportional to regional Q. After resumption of breathing, regional specific alveolar V (sVA, ventilation per unit of alveolar gas volume) can be calculated from the tracer washout rate. The PET scanner imaged 15 contiguous, 6-mm-thick, slices of lung. Vertical gradients of Q and sVA were computed by linear regression, and spatial heterogeneity was assessed from the squared coefficient of variation (CV(2)). Both CV and CV were corrected for the estimated contribution of random imaging noise. We found that 1) both Q and V had vertical gradients favoring dependent lung regions, 2) vertical gradients were similar in the supine and prone position and explained, on average, 24% of Q heterogeneity and 8% of V heterogeneity, 3) CV was similar in the supine and prone position, and 4) CV was lower in the prone position. We conclude that, in recumbent, spontaneously breathing humans, 1) vertical gradients favoring dependent lung regions explain a significant fraction of heterogeneity, especially of Q, and 2) although Q does not seem to be systematically more homogeneous in the prone position, differences in individual behaviors may make the prone position advantageous, in terms of V-to-Q matching, in selected subjects.

Adult↗

Alterations in regional ventilation, perfusion, and shunt after smoke inhalation measured by PET.

Regional changes in ventilation and perfusion occurring in the early hours after smoke inhalation injury were evaluated through the use of positron emission tomography. Five lambs were imaged before and 1, 2, and 4 h after receiving 100 breaths of cotton smoke. Utilizing a recently developed model of (13)N tracer kinetics (3), we evaluated changes in ventilation, perfusion, shunt, and regional gas content in nondependent, middle, and dependent lung zones. The data demonstrated a progressive development of regional shunt in dependent (dorsal) regions in which perfusion remained the highest throughout the study. These findings, together with decreasing regional ventilation and fractional gas content in the dependent regions, correlated with decreasing arterial Pa(O(2)) values over the course of the study. A negative correlation between regional shunt fraction and regional gas content in dependent and middle regions suggests that shunt was caused by progressive alveolar derecruitment or flooding.

Animals↗