The significance of morphologic chronic hyperplastic bronchitis.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to R S Mitchell.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
PURPOSE: To describe the use of endovascular stent-grafts to treat acute ruptures of the descending thoracic aorta as an alternative to surgery in high-risk patients. MATERIALS AND METHODS: From July 1992 to August 1996, 95 patients underwent stent-grafting of the descending thoracic aorta for a variety of lesions. Of these, 11 patients with acute (< or = 7 days) rupture from aneurysms (n = 8) or trauma (n = 3) underwent repair with use of endovascular stent-grafts. Rupture was confirmed with preoperative imaging studies and occurred in the mediastinum (n = 9), the pleural space (n = 1), or the lung (n = 1). All patients were considered high surgical risk due to generalized cardiopulmonary disease and/or previous thoracotomies. Stent-grafts were constructed from Z stents covered with polyester fabric and delivered through a catheter under fluoroscopic control from a remote access site. RESULTS: Stent-graft deployment was successful in all patients. There were no complications of perigraft leak, stent migration, paraplegia, or intraoperative death. Two patients died in the follow-up period: one of ventricular perforation during unrelated thoracic surgery for tumor resection (day 1) and one of cardiac arrest (day 28). All others are alive (mean follow-up, 15.1 months). CONCLUSION: For acute rupture of the thoracic aorta, endovascular stent-graft repair is technically feasible and may be a therapeutic alternative to a surgical interposition graft in patients considered high risk for conventional thoracotomy. Long-term studies are necessary to determine the role of stent-grafts in preventing future aortic rupture.
PURPOSE: Standard therapy of mycotic aneurysms in the descending aorta consists of thoracotomy and in situ graft placement or extraanatomic bypass. The alternative use of endovascular stent-grafts was evaluated for management of infected aneurysms of the thoracic aorta. MATERIALS AND METHODS: In a retrospective analysis during a 5-year period, 112 patients underwent stent-graft placement for thoracic aortic aneurysms. Three patients (mean age, 68.6; range, 64-70 years) had mycotic thoracic aneurysms. Stent-grafts were constructed from Z stents covered with polyester fabric and were delivered remotely through a catheter under fluoroscopic guidance. RESULTS: Complete thrombosis of the mycotic aneurysms was achieved in all patients. One patient required a second separate stent-graft placement procedure because of migration of the initial device; the second patient underwent surgical repair of a ruptured mycotic abdominal aortic aneurysm followed immediately by stent-graft placement for a chronic mycotic thoracic aneurysm; a third patient underwent repair of two infected false aneurysms secondary to complete rupture of a surgical interposition graft. There were no complications of persistent bacteremia despite placement of the stent-graft device at the site of primary infection, reinfection, delayed rupture, paraplegia, distal emboli, or surgical conversion. One patient died of cardiac arrest at 25 months; there were no perioperative deaths (< or = 30 days). The remaining two patients were alive and well at median follow-up of 24 months (range, 4-25 months). CONCLUSION: Endovascular stent-grafts combined with antibiotic therapy may be an alternative to conventional thoracotomy in managing mycotic aneurysms of the descending thoracic aorta.
PURPOSE: The authors describe their experience with the use of single-piece, tapered stent-grafts for the treatment of abdominal aortic or aortoiliac aneurysms. MATERIALS AND METHODS: Single-piece, tapered stent-grafts were placed in 15 patients for the treatment of abdominal aortic aneurysms with small distal necks (n = 13), and aortoiliac aneurysms (n = 2). There were 13 men and two women who ranged in age from 59 to 83 years (mean, 71 years). Usual open surgery was considered high risk in all patients because of comorbid medical conditions. The stent-grafts were made of Z stents covered with polytetrafluoroethylene (PTFE). Additional stent-grafts needed to treat perigraft leaks were made of Z stents covered with woven polyester (n = 5), Wallstents covered with PTFE (n = 2), Z stents covered with PTFE (n = 1), and a PTFE-covered Palmaz stent (n = 1). After stent-graft placement, the contralateral iliac artery was occluded by a blocking device composed of either a PTFE-covered Palmaz (n = 1) or Z stent (n = 13), and a femoral-femoral bypass was created. RESULTS: After placement of the stent-grafts, immediate perigraft leaks were observed in eight patients (53%). These were at the proximal (n = 5) or the distal end (n = 3). All, except one, were treated successfully with additional stent-grafts. The one failure was in a patient who developed aortic rupture after balloon dilation, requiring open surgical repair. Second procedures were required in four patients (27%), including three leaks treated successfully with coil embolization and/or a back-up stent-graft, and one stent-graft migration and thrombosis treated by thrombolysis and placement of an additional stent-graft. One patient died of respiratory failure 23 days after placement of the stent-graft. The mean follow-up was 12 months (range, 4-26 months). On the last follow-up, the aneurysms in the 13 living patients remained thrombosed. CONCLUSION: Treatment of aortoiliac aneurysms with use of single-piece, tapered stent-grafts is feasible in selected patients. The morbidity and mortality rates compare favorably with those of the open surgical procedures in a high-risk population. Further improvements in the technique and longer follow-up data are needed before this procedure can be recommended for the treatment of all aortoiliac aneurysms.
To investigate the regional variability in arterial and venous endothelial prostacyclin (PGI2) biosynthesis, we obtained 1-cm segments of carotid arteries, external jugular veins, femoral arteries and veins, iliac arteries and veins, inferior venae cavae (IVC), and aortas from 17 dogs. Vessel luminal PGI2 production was measured in the basal state by radioimmunoassay of 6-keto-prostaglandin F1 alpha (6-keto-PGF1 alpha). A total of 90 arterial specimens (57, 19, and 14 segments, respectively, of femoral/carotid arteries, iliac arteries, and aorta) and 41 venous specimens (15, 10, and 16 segments, respectively, of femoral/jugular veins, iliac veins, and IVC) were analyzed. Overall, arterial endothelial 6-keto-PGF1 alpha was higher than venous (8.1 +/- 0.5 ng/ml vs. 4.9 +/- 0.7 ng/ml, p less than 0.0004); 6-keto-PGF1 alpha levels were greater in the arteries than in their corresponding veins [femoral/carotid arteries (6.3 +/- 0.4 ng/ml) vs. femoral/jugular vein (2.1 +/- 0.4 ng/ml), p less than 0.0002; iliac arteries (9.3 +/- 1.0 ng/ml) vs. iliac veins (4.8 +/- 0.9 ng/ml), p less than 0.005; aorta (14.0 +/- 1.6 ng/ml) vs. IVC (7.5 +/- 1.4 ng/ml), p less than 0.006].(ABSTRACT TRUNCATED AT 250 WORDS)
Explore the source record for details and available documents.
Explore the source record for details and available documents.