Search PubMed⌕ Search

Biomedical subjects

R S Cobbold

Publications and source records attributed to R S Cobbold.

At least 37 records · Page 2Linked to original sources

Three-dimensional display of calculated velocity profiles for physiological flow waveforms.

PURPOSE: To improve the understanding of the nature of pulsatile flow, three-dimensional idealized velocity profiles corresponding to measured physiological mean flow velocity waveforms were displayed at selected instants throughout the flow cycle. METHODS: The Fourier harmonics for each waveform were determined, and their corresponding velocity profiles at each instant of time were calculated with the Womersley equations. Velocity profiles were calculated by summing the contributions from each harmonic. RESULTS: Calculated profiles were displayed in a three-dimensional perspective for both normal carotid and femoral arteries and for simple sinusoidal flow with a superimposed steady component. CONCLUSION: The potential value of such displays is discussed in terms of gaining an improved understanding of the nature of pulsatile flow and clarifying the interpretation of Doppler ultrasound recordings.

Adult↗

A numerical simulation of flow in a two-dimensional end-to-side anastomosis model.

In order to understand the possible role that hemodynamic factors may play in the pathogenesis of distal anastomotic intimal hyperplasia, we carried out numerical simulations of the flow field within a two-dimensional 45 degree rigid-walled end-to-side model anastomosis. The numerical code was tested and compared with experimental (photochromic dye tracer) studies using steady and near-sinusoidal waveforms, and agreement was generally very good. Using a normal human superficial femoral artery waveform, numerical simulations indicated elevated instantaneous wall shear stress magnitudes at the toe and heel of the graft-host junction and along the host artery bed. These sites also experienced highly variable wall shear stress behavior over the cardiac cycle, as well as elevated spatial gradients of wall shear stress. These observations provide additional evidence that intimal hyperplasia may be correlated to wall shear stresses over the cardiac cycle, high wall shear stress gradients, or a combination of the three. The limitations of the present work (especially in regard to the two-dimensional nature of the flow simulations) are discussed, and results are compared to previous observations about distal anastomotic intimal hyperplasia.

Anastomosis, Surgical↗

Hemodynamics of a side-to-end proximal arterial anastomosis model.

PURPOSE: The purpose of this article was to analyze the fluid mechanical effects of a side-to-end proximal anastomosis and to compare the results with those from our earlier study on the end-to-side distal anastomosis. METHODS: The photochromic tracer technique was used to determine the instantaneous wall shear stress and to visualize the overall flow field under pulsatile flow conditions. The flow consisted of a sinusoid plus a steady component with mean and modulation Reynolds numbers of 355 and 565, respectively, and a Womersley number of 7.9. RESULTS: At the toe and heel of the junction, very high and positive wall shear stresses were seen together with substantial nonperiodic fluctuations. The peak wall shear stress was about four times higher at the toe and about seven times higher at the heel than the maximum values observed at about four tube diameters upstream from the junction. On the bed of the host vessel, nonperiodic fluctuations were also observed, but the shear stresses were mainly negative with magnitudes comparable to those seen upstream. With leakages of 11% and 28% of the mean flow through the blocked end of the host vessel, the shear stress pattern seemed to be significantly affected only at the toe for the higher leakage. Further, when the mean Reynolds number was reduced to 320, the magnitudes of the variations in the wall shear stress were reduced proportionately, except at the heel, where the reduction was much larger than expected. CONCLUSIONS: It appears that the preferential development of intimal hyperplasia at the distal end-to-side anastomosis may be promoted by low wall shear stress at the toe and heel, and probably by high shear stresses or shear stress gradients on the bed.

Anastomosis, Surgical↗

Visualization of complex flow fields, with application to the interpretation of colour flow Doppler images.

The interpretation of colour flow Doppler images in regions of complex flow can be difficult. To aid in such interpretations, we have developed software which accepts as input the results of a fluid flow simulation program and produces simulated colour flow Doppler images on a workstation. This allows direct comparison between well-described flow fields and colour flow Doppler images. Application of this approach is demonstrated for flow in a two-dimensional model of a distal graft-to-vessel anastomosis, and the interpretation of the results for three-dimensional flows is briefly discussed. In addition, a method for presenting two-dimensional (vectorial) velocity data via colour coding is presented.

Algorithms↗

A unified approach to modeling the backscattered Doppler ultrasound from blood.

A unified approach to modeling the backscattered Doppler ultrasound signal from blood is presented. The approach consists of summing the contributions from elemental acoustic voxels each containing many red blood cells (RBC's). For an insonified region that is large compared to a wavelength, it is shown that the Doppler signal is a Gaussian random process that arises from fluctuation scattering, which implies that the backscattered power is proportional to the variance of local RBC concentrations. As a result, some common misconceptions about the relationship between the backscattering coefficient and hematocrit can be readily resolved. The unified approach was also used to derive a Doppler signal simulation model which shows that, regardless of flow condition, the power in the Doppler frequency spectrum is governed by the exponential distribution. For finite beamwidth and paraxial flow, it is further shown that the digitized Doppler signal can be modeled by a moving average random process whose order is determined by the signal sampling rate as well as the flow velocity profile.

Biophysical Phenomena↗

Experimental study of the effects of pulsed Doppler sample volume size and position on the Doppler spectrum.

With a pulsed Doppler system, the recorded Doppler spectrum is expected to vary depending upon the sample volume size relative to the diameter of the vessel, the position of the sample volume in the vessel and the velocity profile. In the in vitro experiments described in this paper, the velocity profile was kept constant by using steady parabolic flow in a flow model. As the Doppler sample volume size and position were changed, the maximum variations of quantitative measurements from the Doppler spectrum were determined. The maximum, mean and mode frequencies and spectral broadening index (SBI) were affected by the position of the sample volume but to a lesser degree by its length (1.5-5.0 mm) relative to the 9.5 mm beam path length across the tube. When the centre of the Doppler sample volume was moved within the central 25% of the tube, the maximum variations were as follows: maximum frequency 3-5%, mean frequency 8-9%, mode frequency 8-9% and SBI 16-18%, where the range indicates the effect of increasing the sample volume size. Based on these results obtained under steady flow conditions in vitro, it is concluded that quantification of pulsed Doppler spectra may be feasible if the sample volume is positioned within the central 25% of the vessel.

Blood Flow Velocity↗

Quantitative study of steady flow using color Doppler ultrasound.

The use of color Doppler flow mapping systems for quantitative in vitro studies of flow fields is examined and illustrated. A 5-MHz color Doppler system was used, and the resolution was determined by comparing the results of flow-field measurement for steady parabolic pipe flow with calculated values. The velocity accuracy was about 6% of the velocity corresponding to half the pulse repetition frequency, and the spatial resolution was better than 1 mm. Frame frequency limitations permitted only partial tracking of fast temporal changes in the flow field. However, detection of vortices downstream from a small cylinder placed in the flow tube was significantly enhanced by synchronizing the frame frequency with the vortex shedding frequency and using a velocity-variance mode. Color Doppler aliasing was found to be useful to define streamlines and determine whether the flow was laminar or turbulent. The color Doppler system clearly imaged Poiseuille, transitional and turbulent flow and vortex shedding in vitro. It is concluded that color Doppler ultrasound flow mapping can enable large, complex flow fields to be quantitatively studied in vitro.

Blood Flow Velocity↗

Computer simulation of blood flow patterns in arteries of various geometries.

The purpose of this study is to illustrate the application of computer simulation to the study of blood flow through arteries and to demonstrate the relationship between geometry of the vessels and local flow patterns. A finite element computer program was developed to simulate steady and pulsatile blood flow by solving the continuity and Navier-Stokes equations. The accuracy of the computational method has been confirmed by comparing the numeric results to analytic solutions and to published experimental data from physical models. The results are presented as plots of the velocity vectors, streamlines, and pressure contours. The computational model has been applied to illustrate flow patterns in the following situations: pulsatile flow in a cylindric artery and an artery with an axisymmetric stenosis, steady flow in cylindric arteries with stenoses of varying severity and with different flow rates, steady flow in an artery containing a fusiform aneurysm, steady flow in a two-dimensional model of a symmetric Y-shaped bifurcation, and steady flow in a two-dimensional model of the carotid bifurcation. Regions that are commonly associated with arterial disease often coincide with zones of reversed or stagnant flow. In conclusion, the versatility and feasibility of computational simulation of blood flow is illustrated by this study. Although this mathematic model is a simplification of the real flow phenomena, it yields results that provide useful insights into the understanding of local blood flow patterns for a variety of complex geometries.

Aneurysm↗

Development of methods to analyse transcranial Doppler ultrasound signals recorded in microgravity.

During space flights, several clinical syndromes may be the result of changes in cerebral circulation. The purpose of the paper is to describe the development and initial evaluation of a system for recording, processing and displaying transcranial Doppler ultrasound (TCD) waveforms from the middle cerebral artery (MCA) in microgravity. Volunteers were repeatedly subjected to 15-20 s intervals of microgravity ('near zero gravity') during flights on the KC-135 military aircraft. Continuous TCD recordings from the MCA were stored on magnetic tape. The paper describes the system that was developed to digitise the Doppler ultrasound data and markers that corresponded to the various levels of microgravity, obtain the maximum and mean Doppler waveforms, identify the waveforms and quantify them. The results demonstrate the feasibility of making TCD recordings in a microgravity environment and illustrate excellent performance of the system and its ease of operation. Quantitative waveform analysis of the recordings from the first subject studied in the supine position showed statistically significant changes in MCA velocity waveforms during microgravity.

Cerebral Arteries↗

Detailed visualization of pulsatile flow fields produced by modelled arterial stenoses.

A multiple trace photochromic method was used to visualize the pulsatile flow field created by modelled arterial stenoses of 38% and 65% area reductions. Using flow parameters similar to those of a medium sized artery in man, the flow patterns at seven axial locations in relation to the stenosis were simultaneously photographed at various times throughout the flow cycle. With the 65% stenosis, the wall shear stress in the vicinity of the reattachment point was found to fluctuate quite strongly during the turbulent phase of the flow cycle, giving rise to instantaneous shear stresses that were at least eight times larger than those measured upstream. For the 38% stenosis, much smaller shear stresses were observed. These and other results are described in detail.

Arterial Occlusive Diseases↗

Effects of transducer beam geometry and flow velocity profile on the Doppler power spectrum: a theoretical study.

A theoretical model is used to show how the Doppler spectrum for various axisymmetric velocity profiles is affected by beam misalignment and incomplete insonation. Results are presented for both circular and square beam geometries. Moreover, a closed-form expression is derived for the power spectral density received by an on-axis transducer with a Gaussian beam profile. It is shown that the error incurred in measuring the mean Doppler frequency with such a profile will generally be bounded by the results for the circular and square beam geometries. The effects of an ideal high-pass filter on the mean Doppler frequency and the backscattered Doppler power are examined. It is shown that such a filter can introduce large differences in the measured systolic to diastolic power ratios. Finally, theoretical expressions and results are presented for the spectral broadening index (SBI), normalized spectral variance (NSV), coefficient of kurtosis (CK), the coefficient of skewness (CS) as functions of the axisymmetric velocity profile shape assuming complete uniform insonation.

Blood Flow Velocity↗

Steady and pulsatile flow fields in an end-to-side arterial anastomosis model.

We investigated the flow field within a rigid-walled in vitro model of an end-to-side 45 degree anastomosis in an attempt to identify possible hemodynamic factors that may contribute to the pathogenesis of distal anastomotic intimal hyperplasia. A high-resolution photochromic tracer technique was used to visualize the flow in orthogonal planes and to determine the axial wall shear stress profiles for both steady and pulsatile flows over a range of physiologically relevant conditions. The flow field showed qualitative similarities to those seen in curved vessel: rapidly moving fluid from the graft section affects the bed of the host vessel, that is, the wall opposite the anastomosis, eventually advancing down the host vessel in a spiraling motion. A small mobile separation zone was noted at the toe of the anastomosis. Comparison of wall shear stress profiles with previously reported preferential sites for the development of intimal hyperplasia supported a low wall shear stress and/or flow separation pathogenesis hypothesis. One notable exception was the bed of the host artery that appeared to be subjected to a complex hemodynamic environment.

Arteriovenous Shunt, Surgical↗

Evidence of a possible link between poststenotic dilation and wall shear stress.

The effects of an axisymmetric 65% area reduction stenosis on a pulsatile flow were investigated by use of an in vitro model that permits simultaneous visualization of the flow velocity profiles at seven sites. By use of seven lenses to focus the ultraviolet light from a nitrogen laser, seven thin blue lines were produced in the photochromic solution flowing through the tube. The displacement profiles of the dye traces were photographed, resulting in the acquisition of the velocity profiles. From these traces, the flow pattern was determined, and the wall shear stresses were measured. Turbulence was generated 3.3 to 6.5 tube diameters downstream from the edge of the stenosis, depending on the time in the pulsatile flow cycle. Maximum wall shear stress fluctuations between positive and negative values appeared to lie within 1.6 to 3.3 tube diameters downstream of the stenosis. In several illustrative clinical cases of thoracic outlet arterial compression, the poststenotic dilation was maximum at 2.0 +/- 0.3 vessel diameters downstream. Based on these observations, it is postulated that wall shear stress fluctuations may be important in the development of poststenotic dilation.

Arteries↗

On the design and evaluation of a steady flow model for Doppler ultrasound studies.

For experimental studies of pulsed and continuous wave Doppler systems, a steady flow model has the important advantage of simplicity in interpreting the results. However, there are a number of important aspects of the design that require careful consideration before a satisfactory design can be achieved. This paper discusses these aspects and some of the difficulties that can arise. It also describes the design and evaluation of a steady flow model that uses a rigid tube with a suspension of glutaraldehyde hardened red blood cells in physiological saline as the scattering medium.

Animals↗

A new method for Doppler frequency analysis that promises a major improvement in performance.

The Doppler grey scale waveform obtained by frequency analysis is related to the blood flow velocity in the vessel under examination. Consequently, detailed evaluation of the Doppler spectral waveform or the instantaneous Doppler spectrum is clinically useful for assessing arterial disease. The purpose of this paper is to demonstrate the potential advantages of a new frequency analysis method (autoregressive moving average) for processing and displaying continuous wave and pulsed Doppler signals by comparing the quality of the Doppler spectral waveforms produced by this new method to those obtained by standard Fast Fourier transform analysis. Continuous wave pulsed Doppler recordings were stored on a computer and reprocessed by Fast Fourier transform and autoregressive moving average methods. Varying degrees of noise were added to both types of Doppler recordings in order to simulate the problems encountered in the clinical vascular laboratory. By comparing the two methods using standard Doppler spectral waveforms and 3-dimensional spectral plots, under adverse conditions of significant noise, the autoregressive moving average technique proved to be superior to the classical Fast Fourier approach. It is concluded that the autoregressive method of frequency analysis offers the potential for achieving significant improvements in the display of the Doppler spectral waveform when compared to the classical Fast Fourier approach. Such improvements may improve the accuracy in arterial disease assessment.

Blood Flow Velocity↗

Potential limitations of center-line pulsed Doppler recordings: an in vitro flow visualization study.

In this study an in vitro model that permits visualization of the flow velocity profile has been used to determine if duplex pulsed Doppler recordings made with a small sample volume in the center line of the vessel can determine the severity of a stenosis in the 38% to 75% range of cross-sectional area reduction. Because most Doppler instruments measure the maximum peak frequency and the extent of spectral broadening, observations in the flow model included changes in the center-line maximum velocity and the location and intensity of flow disturbances. The results showed that center-line measurements of maximum velocity (equivalent to peak Doppler frequency) were directly related to the severity of the stenosis as long as the recordings were made from within the throat to about 1.5 to 3 tube diameters downstream, depending on the shape of the stenosis. However, flow disturbances (equivalent to spectral broadening) did not always occur in the center line of the vessel. Stenoses greater than 50% area reduction produced turbulence across the entire vessel in the region 4.5 to 7.5 diameters downstream. The turbulent period started just before peak systole and extended to just less than half the pulse cycle. In the more proximal zone a forward flow jet was present in the central part of the vessel, and reverse flow was present in the outer region. The interfacial layer between these two regions is subjected to high shear rates that resulted in the formation of waves and vortices.(ABSTRACT TRUNCATED AT 250 WORDS)

Arterial Occlusive Diseases↗