Search PubMed⌕ Search

Biomedical subjects

R S Balaban

Publications and source records attributed to R S Balaban.

At least 19 recordsLinked to original sources

Direct imaging of dehydrogenase activity within living cells using enzyme-dependent fluorescence recovery after photobleaching (ED-FRAP).

Reduced nicotine adenine dinucleotide (NADH) is a key metabolite involved in cellular energy conversion and many redox reactions. We describe the use of confocal microscopy in conjunction with enzyme-dependent fluorescence recovery after photobleaching (ED-FRAP) of NADH as a topological assay of NADH generation capacity within living cardiac myocytes. Quantitative validation of this approach was performed using a dehydrogenase system, in vitro. In intact cells the NADH ED-FRAP was sensitive to temperature (Q(10) of 2.5) and to dehydrogenase activation by dichloroacetate or cAMP (twofold increase for each). In addition, NADH ED-FRAP was correlated with flavin adenine dinucleotide (FAD(+)) fluorescence. These data, coupled with the cellular patterns of NADH ED-FRAP changes with dehydrogenase stimulation, suggest that NADH ED-FRAP is localized to the mitochondria. These results suggest that ED-FRAP enables measurement of regional dynamics of mitochondrial NADH production in intact cells, thus providing information regarding region-specific intracellular redox reactions and energy metabolism.

Animals↗

Device-dependent activity estimation and decay correction of radionuclide mixtures with application to Tc-94m PET studies.

Multi-instrument activity estimation and decay correction techniques were developed for radionuclide mixtures, motivated by the desire for accurate quantitation of Tc-94m positron emission tomography (PET) studies. Tc-94m and byproduct Tc isotopes were produced by proton irradiation of enriched Mo-94 and natural Mo targets. Mixture activities at the end of bombardment were determined with a calibrated high purity germanium detector. The activity fractions of the greatest mixture impurities relative to 100% for Tc-94m averaged 10.0% (Tc-94g) and 3.3% (Tc-93) for enriched targets and 10.1% (Tc-94g), 11.0% (Tc-95), 255.8% (Tc-96m), and 7.2% (Tc-99m) for natural targets. These radioisotopes have different half-lives (e.g., 52.5 min for Tc-94m, 293 min for Tc-94g), positron branching ratios (e.g., 0.72 for Tc-94m, 0.11 for Tc-94g) and gamma ray emissions for themselves and their short-lived, excited Mo daughters. This complicates estimation of injected activity with a dose calibrator, in vivo activity with PET and blood sample activity with a gamma counter. Decay correction using only the Tc-94m half-life overestimates activity and is inadequate. For this reason analytic formulas for activity estimation and decay correction of radionuclide mixtures were developed. Isotope-dependent sensitivity factors for a PET scanner, dose calibrator, and gamma counter were determined using theoretical sensitivity models and fits of experimental decay curves to sums of exponentials with fixed decay rates. For up to 8 h after the end of bombardment with activity from enriched and natural Mo targets, decay-corrected activities were within 3% of the mean for three PET studies of a uniform cylinder, within 3% of the mean for six dose calibrator decay studies, and within 6% of the mean for four gamma counter decay studies. Activity estimation and decay correction for Tc-94m mixtures enable routine use of Tc-94m in quantitative PET, as illustrated by application to a canine Tc-94m sestamibi study.

Animals↗

Rapid spectrophotometric determination of oxygen consumption using hemoglobin, in vitro: light scatter correction and expanded dynamic range.

The method of using absorbance in conjunction with hemoglobin (Hb) to monitor rapid changes in oxygen consumption in vitro was improved by using a non-linear calibration technique and multiwavelength spectroscopy. The O(2) dependence of Hb absorbance was effectively linearized using the current technique (R(2) = 0.990+/-0.002, n = 3), and extended the dynamic range of [O(2)] determinations by 1.6-fold over previous approaches. The association/dissociation rates of O(2) and Hb were evaluated using the current approach and were not significant on the 100-ms time domain. A method was also developed for compensating for large amplitude light scattering changes in turbid media using multiwavelength analysis. Both the nonlinear calibration curve and light scattering corrections were validated in isolated porcine heart mitochondrial preparations.

Animals↗

Calcium activation of heart mitochondrial oxidative phosphorylation: rapid kinetics of mVO2, NADH, AND light scattering.

Parallel activation of heart mitochondria NADH and ATP production by Ca(2+) has been shown to involve the Ca(2+)-sensitive dehydrogenases and the F(0)F(1)-ATPase. In the current study we hypothesize that the response time of Ca(2+)-activated ATP production is rapid enough to support step changes in myocardial workload ( approximately 100 ms). To test this hypothesis, the rapid kinetics of Ca(2+) activation of mV(O(2)), [NADH], and light scattering were evaluated in isolated porcine heart mitochondria at 37 degrees C using a variety of optical techniques. The addition of Ca(2+) was associated with an initial response time (IRT) of mV(O(2)) that was dose-dependent with a minimum IRT of 0.27 +/- 0.02 s (n = 41) at 535 nm Ca(2+). The IRTs for NADH fluorescence and light scattering in response to Ca(2+) additions were similar to mV(O(2)). The Ca(2+) IRT for mV(O(2)) was significantly shorter than 1.6 mm ADP (2.36 +/- 0.47 s; p < or = 0.001, n = 13), 2.2 mm P(i) (2.32 +/- 0.29, p < or = 0.001, n = 13), or 10 mm creatine (15.6.+/-1.18 s, p < or = 0.001, n = 18) under similar experimental conditions. Calcium effects were inhibited with 8 microm ruthenium red (2.4 +/- 0.31 s; p < or = 0.001, n = 16) and reversed with EGTA (1.6 +/- 0.44; p < or = 0.01, n = 6). Estimates of Ca(2+) uptake into mitochondria using optical Ca(2+) indicators trapped in the matrix revealed a sufficiently rapid uptake to cause the metabolic effects observed. These data are consistent with the notion that extramitochondrial Ca(2+) can modify ATP production, via an increase in matrix Ca(2+) content, rapidly enough to support cardiac work transitions in vivo.

Animals↗

Imaging of urea using chemical exchange-dependent saturation transfer at 1.5T.

The purpose of this study was to screen for slow proton chemical exchange between water and kidney metabolites using a standard clinical 1.5-T scanner. Imaging was performed using a fast spin-echo sequence with a magnetization transfer (MT) preparation pulse train. Off-resonance saturation ranging from +/-50 to +/-1000 Hz was used on urea and urine phantoms and normal human subjects imaged through the kidneys. The positive frequency was used as the control for each frequency pair. Results of frequency sweeps show an asymmetric MT effect peaking at approximately 100 Hz ( thick similar1 ppm) for urea, urine, and renal parenchyma. Varying differences (5%-25%) occurred with different human subjects. Few differences were observed from phantom water or subject muscle tissue. Chemical exchange is detectable in the kidney near 1 ppm at 1.5 T, attributable to urea. This technique was used to produce in vivo distribution maps of this metabolite in vivo.

Biological Transport↗

Determination of pH using water protons and chemical exchange dependent saturation transfer (CEST).

Solution pH was measured using water proton NMR via chemical exchange dependent saturation transfer (CEST) with selected chemical exchange sites. Several useful pH-sensitive proton chemical exchange agents were found: 5,6-dihydrouracil, 5-hydroxytryptophan, and a combination of 5-hydroxytryptophan and 2-imidazolidinethione. A ratiometric approach was developed that permitted pH determinations that were independent of water T(1) or exchange site concentration.

Contrast Media↗

A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST).

It has been previously shown that intrinsic metabolites can be imaged based on their water proton exchange rates using saturation transfer techniques. The goal of this study was to identify an appropriate chemical exchange site that could be developed for use as an exogenous chemical exchange dependent saturation transfer (CEST) contrast agent under physiological conditions. These agents would function by reducing the water proton signal through a chemical exchange site on the agent via saturation transfer. The ideal chemical exchange site would have a large chemical shift from water. This permits a high exchange rate without approaching the fast exchange limit at physiological pH (6.5-7.6) and temperature (37 degrees C), as well as minimizing problems associated with magnetic field susceptibility. Numerous candidate chemicals (amino acids, sugars, nucleotides, heterocyclic ring chemicals) were evaluated in this preliminary study. Of these, barbituric acid and 5, 6-dihydrouracil were more fully characterized with regard to pH, temperature, and concentration CEST effects. The best chemical exchange site found was the 5.33-ppm indole ring -NH site of 5-hydroxytryptophan. These data demonstrate that a CEST-based exogenous contrast agent for MRI is feasible.

Amino Acids↗

Ca(2+) activation of heart mitochondrial oxidative phosphorylation: role of the F(0)/F(1)-ATPase.

Ca(2+) has been postulated as a cytosolic second messenger in the regulation of cardiac oxidative phosphorylation. This hypothesis draws support from the well-known effects of Ca(2+) on muscle activity, which is stimulated in parallel with the Ca(2+)-sensitive dehydrogenases (CaDH). The effects of Ca(2+) on oxidative phosphorylation were further investigated in isolated porcine heart mitochondria at the level of metabolic driving force (NADH or Deltapsi) and ATP production rates (flow). The resulting force-flow (F-F) relationships permitted the analysis of Ca(2+) effects on several putative control points within oxidative phosphorylation, simultaneously. The F-F relationships resulting from additions of carbon substrates alone provided a model of pure CaDH activation. Comparing this curve with variable Ca(2+) concentration ([Ca(2+)]) effects revealed an approximate twofold higher ATP production rate than could be explained by a simple increase in NADH or Deltapsi via CaDH activation. The half-maximal effect of Ca(2+ )at state 3 was 157 nM and was completely inhibited by ruthenium red (1 microM), indicating matrix dependence of the Ca(2+) effect. Arsenate was used as a probe to differentiate between F(0)/F(1)-ATPase and adenylate translocase activity by a futile recycling of ADP-arsenate within the matrix, catalyzed by the F(0)/F(1)-ATPase. Ca(2+) increased the ADP arsenylation rate more than twofold, suggesting a direct effect on the F(0)/F(1)-ATPase. These results suggest that Ca(2+) activates cardiac aerobic respiration at the level of both the CaDH and F(0)/F(1)-ATPase. This type of parallel control of both intermediary metabolism and ATP synthesis may provide a mechanism of altering ATP production rates with minimal changes in the high-energy intermediates as observed in vivo.

Adenosine Triphosphate↗

MRI of the human eye using magnetization transfer contrast enhancement.

PURPOSE: To determine the feasibility of using magnetization transfer contrast-enhanced magnetic resonance imaging (MRI) to track cataractous lens changes. METHODS: A fast spin-echo sequence was modified to include a magnetization transfer contrast (MTC) preparation pulse train. This consisted of twenty 8.5-msec sinc pulses, 1200 Hz upfield from the water resonance and 1.2-Hz power. The MTC preparation pulse was followed by acquisition through fast spin-echo imaging. The imaging parameters were number of excitations (NEX) = 1, echo time (TE) = 14 msec, recovery time (TR) = 2 sec, echo train length of eight echos, and a matrix size of 256 x 160. To reduce motion artifacts, the volunteers were asked to fixate on a blinking LED. Normal and MTC-enhanced images were acquired from normal volunteers and volunteers with nuclear or cortical cataracts. RESULTS: The eye was adequately imaged, with few motion artifacts appearing. The lens was well resolved, despite the short T(2). The cornea and ciliary body were also clearly visible. In the lens, resolution of the epithelium and cortex were enhanced with MTC. In addition, contrast-to-noise ratios were measured for each image. Examination of the contrast-to-noise ratio confirmed that MTC increased the contrast between the nucleus and cortex. Unenhanced MRIs showed significant differences between the cortex of normal volunteers and volunteers with cataracts. MTC-enhanced images improved the sensitivity to changes in the nucleus. CONCLUSIONS: In this preliminary study, we were able to use MTC-enhanced MRI to obtain high-contrast images of the human lens. Regular and enhanced MRIs detected statistically significant differences between normal and cataractous lenses.

Aged↗

Improved field of view-reducing gradient insert: artifacts and application to cardiac imaging.

An improved homogeneity-spoiling local gradient insert has been constructed and built into the patient bed to reduce its impact on bore size and setup time. It allows the field of view to be reduced without introducing aliasing artifacts. Image quality and artifacts were evaluated for pulse sequences relevant to cardiac imaging. The utility of the insert is demonstrated by a contrast-enhanced perfusion study, in which the reduced field of view allowed a 25% increase in resolution and one more slice to be imaged per heartbeat. J. Magn. Reson. Imaging 1999;10:209-215.

Adult↗

Myocardial velocity gradient imaging by phase contrast MRI with application to regional function in myocardial ischemia.

Velocity-encoded phase contrast magnetic resonance imaging (MRI) has the potential to quantify regional myocardial contractile function with a sensitivity to motion comparable to implanted ultrasonic crystals. An MRI sequence and post-processing algorithm were developed to measure myocardial velocity gradients on a 1.5 T MRI scanner. These methods were validated on a rotating phantom and applied to dogs before (n = 11) and during prolonged coronary occlusion (n = 5). In phantom validation studies, the average absolute error corresponded to motion equivalent to 0.03 +/- 0.04 mm (mean +/- SD) during the repetition time of the experiment. Rigid body corrections during post-processing significantly simplified the interpretation of myocardial velocity vectors. In vivo, rigid body motion contributes substantially to the recorded myocardial velocities in systole and diastole and can give the false impression of regional wall motion abnormalities. After rigid body correction, normal systolic and diastolic velocity vectors in short-axis views of the left ventricle were primarily directed toward the center of the left ventricle. Transmural radial strain rate was 2.0 +/- 0.6 sec-1 during systole and -3.6 +/- 1.1 sec-1 during early diastole in normal canine hearts. Ischemic myocardium was easily discriminated from normal left ventricle by velocity-encoded phase contrast MRI both qualitatively and quantitatively (P < 0.01 in systole and P < 0.05 in early diastole). Although the myocardial velocity images have a spatial resolution on the order of a millimeter, the velocity encoding describes the mechanical consequences of focal myocardial ischemia with sensitivity to submillimeter displacement of the pixels. The three-dimensional nature of velocity-encoded MRI is particularly well suited to the study of the complex motion of the heart in vivo.

Animals↗

DENSE: displacement encoding with stimulated echoes in cardiac functional MRI.

Displacement encoding with stimulated echoes (DENSE) was developed for high-resolution myocardial displacement mapping. Pixel phase is modulated by myocardial displacement and data spatial resolution is limited only by pixel size. 2D displacement vector maps were generated for the systolic action in canines with 0.94 x 1.9 mm nominal in-plane resolution and 2.3 mm/pi displacement encoding. A radial strain of 0.208 was measured across the free left ventricular wall over 105 ms during systole. DENSE displacement maps require small first-order gradient moments for encoding. DENSE magnitude images exhibit black-blood contrast which allows for better myocardial definition and reduced motion-related artifacts.

Animals↗

High-resolution strain analysis of the human heart with fast-DENSE.

Single breath-hold displacement data from the human heart were acquired with fast-DENSE (fast displacement encoding with stimulated echoes) during systolic contraction at 2.5 x 2.5 mm in-plane resolution. Encoding strengths of 0.86-1.60 mm/pi were utilized in order to extend the dynamic range of the phase measurements and minimize effects of physiologic and instrument noise. The noise level in strain measurements for both contraction and dilation corresponded to a strain value of 2.8%. In the human heart, strain analysis has sufficient resolution to reveal transmural variation across the left ventricular wall. Data processing required minimal user intervention and provided a rapid quantitative feedback. The intrinsic temporal integration of fast-DENSE achieves high accuracy at the expense of temporal resolution.

Heart↗

Comparison of 3D BOLD functional MRI with spiral acquisition at 1.5 and 4.0 T.

In order to investigate the merit of high field strength for BOLD-contrast-based functional magnetic resonance imaging (fMRI) studies, multishot gradient-echo fMRI experiments during motor cortex activation were performed on 1.5- and 4.0-T scanners with equivalent hardware, on the same volunteers. In these studies, artifactual vascular enhancement related to inflow effects was minimized, and large brain areas were covered by using a 3D scan technique. Temporal signal stability was optimized by using spiral readout gradients. The sensitivity for detection of activated regions was assessed by measuring the number of "activated voxels" and their average t score in predefined regions of interest. When comparing fMRI experiments with the same total scan time, performed on six subjects, and with acquisition parameters optimized for each field strength separately, the 4.0-T scanner proved to give superior results, with a 70% greater number of activated voxels and a 20% higher average t score for the activated voxels.

Humans↗

Impairment of myocardial calcium homeostasis by antibodies against the adenine nucleotide translocator.

The adenine nucleotide translocator (ANT) is an autoantigen in myocarditis and dilated cardiomyopathy. Carrier-specific antibodies impair myocardial energy metabolism and heart function. They cross-react with a myolemmal calcium channel and alter calcium fluxes in isolated myocytes. To test whether antibodies against the ANT can alter calcium homeostasis in intact hearts, guinea pigs were immunized with the carrier protein and their isolated hearts loaded with the intracellular calcium indicator INDO-1. The diastolic and systolic ratios of fluorescence signals at 410 nm and 510 nm (emission wavelengths of the calcium-bound and calcium-free indicator), 'd-s410/510', were measured by excitation at 364 nm. This index of the transient calcium concentration associated with the contraction cycle correlated with the external heart work (EHW) in non-immunized controls. EHW of immunized animals was lower (76 +/- 62 vs 153 +/- 47 mJ/g/min in controls, p < 0.005) and the amplitude of d-s410/510 was elevated (27.6 +/- 4.1% of the average ratio of the whole heart cycle vs 21.7 +/- 1.2% in controls, p < 0.005) and essentially independent of EHW. Isoproterenol stimulation increased EHW in all hearts but d-s410/510 was hightened in control hearts, only. Thus, a disorder between cytosolic calcium transients and work was recorded in hearts from guinea pigs immunized with the ANT. It may contribute to an immunopathic mechanism of heart failure subsequent to myocarditis.

Animals↗

Real-time cardiac MRI using DSP's.

A real-time cardiac magnetic resonance imaging (MRI) system has been implemented using digital signal processing (DSP) technology. The system enables real-time acquisition, processing, and display of ungated cardiac movies at moderate video rates of 20 images/s. A custom graphical user interface (GUI) provides interactive control of data acquisition parameters and image display functions. Images can be compressed into moving-picture experts group (MPEG) movies, but are displayed on the console without compression during the scan. Compared to existing real-time MRI systems, implementation with DSP's allows rapid parallel computations, fast data transfers, and greater system flexibility, including the ability to scale to multiple channels, at the expense of somewhat higher component cost.

Artifacts↗