Search PubMedSearch

Biomedical subjects

R R Krueger

Publications and source records attributed to R R Krueger.

At least 19 recordsLinked to original sources

Central bump-like opacity as a complication of high hyperopic photorefractive keratectomy.

PURPOSE: A new complication is reported in association with high hyperopic excimer laser photorefractive keratectomy. METHODS: One thousand consecutive eyes were treated with a Meditec MEL-60 excimer laser (Meditec Inc, Heroldsberg, Germany) for hyperopic refractive error between +1 diopters and +7 diopters. RESULTS: Three eyes with high hyperopic corrections between +5 and +6 diopters had a central, round bump-like subepithelial scar develop 1 month after hyperopic photorefractive keratectomy, which reduced the uncorrected and spectacle-corrected visual acuity. CONCLUSION: Central bump-like opacity is a new, visually significant complication of unknown origin associated with high hyperopic photorefractive keratectomy. Possible causes of this complication include drying and edema of the cornea as a result of prolonged exposure, interruption of the peripheral superficial nerve plexus affecting the central anterior stroma, and abnormal epithelial or tear film function resulting from excessive central steeping.

Adult

Improvement of visual function with glare testing after photorefractive keratectomy and radial keratotomy.

PURPOSE: To evaluate the effect of a glare source on visual function in patients after photorefractive keratectomy and radial keratotomy. METHODS: Thirteen patients (22 eyes) who underwent photorefractive keratectomy and 20 patients (40 eyes) who underwent radial keratotomy were evaluated in this cross-sectional study. LogMAR visual acuity and contrast sensitivity were measured. Pupils were measured with the Rosenbaum card. A halogen/tungsten glare source approximated the luminance of headlights of an oncoming car at 100 feet. RESULTS: In the photorefractive keratectomy and radial keratotomy groups, pupils were significantly smaller (P<.01) and the pupillary clearance of the ablation zone in photorefractive keratectomy and the clear zone in radial keratotomy were significantly larger under the glare condition (P<.01). In the photorefractive keratectomy group, visual acuity and contrast sensitivity under the glare condition were significantly higher than in the no-glare condition (P = .02). In the radial keratotomy group, contrast sensitivity under the glare condition was significantly higher than under the no-glare condition (P = .001 to .003). CONCLUSIONS: After photorefractive keratectomy or radial keratotomy, the traditional glare source constricted the pupil and partially masked the optical aberrations, which resulted in an improvement in visual function. A "pupil-sparing" aberration test is needed for evaluation of visual function after refractive surgery.

Adult

Agreement and repeatability of infrared pupillometry and the comparison method.

OBJECTIVE: To evaluate the accuracy and repeatability of the widely used comparison method of measuring pupil size. DESIGN: Cross-sectional study. PARTICIPANTS: Fourteen eyes of seven healthy myopic subjects were examined. INTERVENTION: Two examiners made two repeated measures of pupil diameters of 14 eyes using Rosenbaum card comparison pupillometry and infrared pupillometry. Subjects fixated on a distant visual acuity chart, and pupils were measured under three luminance conditions. The agreement and inter-rater repeatability of both methods were determined. MAIN OUTCOME MEASURES: Outcomes were pupil diameters, limits of agreement, and coefficient of repeatability of two examiners. RESULTS: The mean difference between the two techniques ranged from 0.3 to 0.5 mm. The limits of agreement within two standard deviations ranged from 2.4 to 2.8 mm. Coefficient of repeatability ranged from 0.6 to 1.4 mm for infrared pupillometry and 1.0 to 1.2 mm for Rosenbaum pupillometry. Inter-rater repeatability of Rosenbaum pupillometry was consistently pupil diameter biased. Pupil diameters measured with the Rosenbaum method were consistently larger than diameters measured with the infrared technique for both examiners under all luminance conditions. CONCLUSIONS: Results indicate that although the mean difference in techniques was small, the range of the agreement between the Rosenbaum and the infrared techniques was large. The Rosenbaum method consistently overestimated pupil diameters and was subject to inter-rater repeatability bias. Rosenbaum pupillometry may not be appropriate when accurate pupil measurements are required. The results have implications for many clinical trials in ophthalmology, including those evaluating refractive surgery that use Rosenbaum comparison pupillometry.

Adult

Photorefractive keratectomy for low-to-moderate myopia and astigmatism with a small-beam, tracker-directed excimer laser.

OBJECTIVE: To assess the safety and effectiveness of the Autonomous Technologies Corporation LADARVision excimer laser system for photorefractive keratectomy correction of myopia and astigmatism. DESIGN: A multicenter, prospective, noncomparative case series. PARTICIPANTS: The cohort consisted of 467 eyes corrected for spherical myopia and 211 eyes corrected for myopia with astigmatism. INTERVENTION: Treatments were performed at six sites in the United States using a 6-mm ablation zone for spherical myopes and a 5.5-mm zone with a 1.0-mm blend for astigmats. MAIN OUTCOME MEASURES: Visual acuity, subjective refraction, corneal haze, intraocular pressure, complications, adverse reactions, patient satisfaction, and corneal endothelial changes. RESULTS: Twelve-month follow-up was available on 414 spherical eyes and 175 astigmatic eyes. The results for spherical eyes with correction between -1 and -5.99 diopters (D) were: uncorrected visual acuity (UCVA) of 20/40 or better achieved by 98.1%, 20/20 or better by 72%, 1.8% lost 2 lines and 0.3% lost greater than 2 lines of best spectacle-corrected visual acuity (BSCVA); 76.4% were within 0.50 D of the target correction and 94.4% were within 1.00 D. The results for myopia with astigmatism with spherical equivalent correction between -1 and -5.99 D were: UCVA of 20/40 or better in 97.4%, 20/20 or better in 61.7%, 2.5% lost 2 lines and no eyes lost greater than 2 lines BSCVA; 73.9% were within 0.50 D of the target correction and 95% were within 1.00 D. For spherical myopes combined with myopic astigmats corrected for 6 to 10 D, results were: UCVA of 20/40 or better in 93.4%, 20/20 or better in 61.2%, 2.3% lost 2 lines and no eyes lost greater than 2 lines of BSCVA; 67.2% were within 0.50 D of the desired correction and 87.8% were within 1.00 D. Refractive stability was achieved between 3 and 6 months for the spherical and astigmatic groups. No eyes had corneal haze graded as moderate or greater, and there was no significant decrease in endothelial cell density. CONCLUSIONS: Patients treated for 1 to 10 D of spherical equivalent myopia, with or without astigmatism, showed early refractive stability, excellent UCVA, no significant loss of BSCVA, no loss of endothelial cell density, and very low levels of corneal haze to 12 months after surgery.

Adult

Role of clearance and treatment zones in contrast sensitivity: significance in refractive surgery.

PURPOSE: To evaluate the relationship between contrast sensitivity, surgical treatment zone, and clearance (ablation or clear zone-pupil diameter) in photorefractive keratectomy (PRK) and radial keratotomy (RK). SETTING: Saint Louis University Eye Institute, St. Louis, Missouri, and Hunkeler Eye Center, Kansas City, Missouri, USA. METHODS: Thirteen patients had PRK and 20, RK. Contrast sensitivity was measured with the Stereo Optical F.A.C.T. (F.A.C.T.) and VectorVision CSV-1000 (VV) charts. Pupils were measured with the Rosenbaum card. RESULTS: In the PRK group, VV contrast sensitivity at 6 and 12 cycles per degree (cpd) correlated with the ablation zone (r2 = 0.18 and 0.22, respectively), while visual acuity and F.A.C.T. contrast sensitivity did not correlate. In the RK group, both VV and F.A.C.T. contrast sensitivity at 6 cpd correlated with clearance (r2 = 0.29 and 0.12, respectively). Pupils were larger with the VV test than with the F.A.C.T. chart because ambient chart luminance was less in the former. CONCLUSION: Contrast sensitivity is likely a more sensitive indicator of visual function than acuity in refractive surgery. The VV system unmasks aberrations from the transition zone of ablated and unablated cornea in PRK. Larger samples are needed to determine the critical ablation clearance of the pupil to avoid loss of visual function.

Adult

Comparison of contrast sensitivity in different soft contact lenses and spectacles.

PURPOSE: To compare the visual performance of soft contact lenses and spectacles. METHODS: Twenty eyes of ten patients were examined. Each patient was fit with Acuvue, Cibasoft, and Biomedics contact lenses in random order. LogMar visual acuity and contrast sensitivity using the VectorVision CSV-1000 were measured. RESULTS: There was no significant difference in visual acuity between any contact lenses (P=.15). Contrast sensitivity at 12 cycles/degree was significantly lower for the Cibasoft lens compared to spectacles (P=.04). There was no significant difference between spectacles and contact lenses for remaining spatial frequencies (P=.07-.35). CONCLUSIONS: Visual acuity appears to be an insensitive method for evaluating soft contact lenses. The lathe-cut manufacturing process may be responsible for reduced visual function compared to cast-molded lenses. Further study in this area is needed.

Adult

Clinical analysis of the neodymium:YLF picosecond laser as a microkeratome for laser in situ keratomileusis. Partially Sighted Eye Study.

PURPOSE: To evaluate the use of a picosecond neodymium:YLF (Nd:YLF) laser as a nonmechanical intrastromal microkeratome. SETTING: Universita Cattolica del Sacro Cuore, Rome, Italy. METHODS: An intrastromal spiral disc pattern of picosecond laser pulses was used to create a corneal flap for laser in situ keratomileusis (LASIK) in 14 partially sighted eyes. RESULTS: Flaps with a 6.0 mm diameter and 180 to 200 microns depth were successfully created in most cases. The underlying stroma was treated with a Lambda Physik excimer laser using a 3.5 to 4.5 mm optical zone. Patients were divided into 3 groups for target corrections of 5.0, 10.0, and 15.0 diopters of myopia. Good corneal clarity and refractive undercorrection were recorded in each group 6 months postoperatively. The undercorrection was due in part to the limited optical zone of the laser's delivery system. Some flap decentration was noted. CONCLUSION: This pilot study indicates that the Nd:YLF picosecond laser may be clinically applied for creating corneal flaps for LASIK. Further refinements of the laser delivery system will include enlargement of the flap diameter and improvements in flap centration. The use of a femtosecond laser may expand the capabilities and precision of this technology.

Adult

Clinical analysis of steep central islands after excimer laser photorefractive keratectomy.

PURPOSE: To examine topographic irregularities known as steep central islands that may occur after excimer laser refractive surgery and affect visual acuity. METHODS: We reviewed the computed corneal topographic maps of 35 eyes that had undergone excimer laser photorefractive keratectomy with an excimer laser for compound myopic astigmatism or anisometropic myopia. Steep central islands were defined as areas of steepening of at least 3 diopters and 1.5 mm in diameter. A classification system was developed based on the presence of steep central islands during the postoperative period as follows: class 0, absent; class 1, present at 1 week; class 2, present at 1 month; class 3, present at 3 months. RESULTS: Steep central islands were seen in 25 eyes (71%) at 1 week, 18 eyes (51%) at 1 month, seven eyes (20%) at 3 months, and four eyes (11%) at 6 months. After surgery without nitrogen gas blowing, 16 of 25 patients had class 2 or 3 steep central islands compared with two of 10 eyes when gas blowing was used. Loss of best spectacle-corrected visual acuity of 2 Snellen lines or more was seen in eight of 18 eyes with class 2 or 3 steep central islands at 1 month and three of 18 eyes at 3 months. A similar loss occurred in one of 17 eyes with class 0 or 1 steep central islands at 1 month and none of 17 eyes at 3 months. In all eyes with only class 2 steep central islands, loss of at least 1 Snellen line of best spectacle-corrected visual acuity at 1 month was associated with visual restoration at 3 months when the island was no longer present. CONCLUSION: Loss of best spectacle-correlated visual acuity is associated with steep central island formation, and may prolong visual rehabilitation after excimer laser photorefractive keratectomy.

Astigmatism

Double-armed McCannell suture for repair of traumatic iridodialysis.

PURPOSE: To repair iridodialysis in a traumatized eye with minimal surgical manipulation. METHODS: We examined a patient with traumatic iridodialysis. The separated iris obstructed the visual axis and was cosmetically disfiguring. RESULTS: At surgery we secured the iridodialysis to the anterior chamber angle by using a new technique with double-armed McCannell suture. CONCLUSION: Compared with other procedures, this technique is simple and provides the least amount of ocular manipulation for iridodialysis repair.

Adult

Role of matrix metalloproteinases in failure to re-epithelialize after corneal injury.

Delayed re-epithelialization of the cornea after injury usually precedes stromal ulceration. Previous findings using a rat thermal injury model suggested that re-epithelialization is impeded by products of resident corneal cells, which destroy adhesive structures at the basement membrane zone. In this study, we provide additional evidence for this concept. Failure to re-epithelialize was found to correlate with an increase in the amounts of gelatinolytic matrix metalloproteinases present in the rat cornea. One of these gelatinases, gelatinase B, is synthesized by the resident corneal cells, and inhibitions of its synthesis correlated with inhibition of basement membrane dissolution. The matrix metalloproteinases collagenase and stromelysin are also synthesized by resident corneal cells in thermally injured corneas of rabbits, but the timing of bulk enzyme synthesis correlated more closely with deposition of repair tissue in the stroma than with failure to re-epithelialize. Nevertheless, in human corneas with repair defects, gelatinase B and collagenase are synthesized by cells in the basal layer of the epithelium directly adjacent to the basement membrane, suggesting that both could participate in dissolution of this structure. Importantly, treatment of thermally injured corneas with a synthetic inhibitor of matrix metalloproteinases significantly improved basement membrane integrity. These data support the concept that over-expression of matrix metalloproteinases by resident corneal cells impedes re-epithelialization after some types of corneal injury.

Animals

Clinical analysis of excimer laser photorefractive keratectomy using a multiple zone technique for severe myopia.

PURPOSE: In an investigational procedure, excimer laser photorefractive keratectomy for severe myopia was performed at three clinical trial centers to determine the effectiveness of the multiple zone technique. METHODS: A VisX Model Twenty/Twenty excimer laser (VisX, Santa Clara, California) was used to perform photorefractive keratectomy on 14 severely myopic eyes (-10.37 to -24.5 diopters) of 12 patients by using a multiple zone technique. Postoperative follow-up ranged from six months to two years; retreatments were performed on four patients, with a follow-up of at least nine months. RESULTS: At six months postoperatively, before retreatment, three of the 14 eyes were within 2 diopters and seven of the 14 eyes were within 4 diopters of attempted correction. Regression of effect to more severe myopia was worse in five eyes treated with nitrogen gas blowing. Retreatments also demonstrated considerable myopic regression. Three patients had loss of two or more lines of best-corrected visual acuity, and these patients also had moderate or severe levels of haze. CONCLUSION: Excimer laser photorefractive keratectomy for severe myopia using a multiple zone technique is associated with considerable regression, haze, and loss of best-corrected visual actuity, especially when performed in association with nitrogen gas blowing.

Adult

New stroboscopic light source for intraoperative retinal fluorescein angiography.

We tested a new stroboscopic light source for intraoperative fluorescein angiography. A pulsed xenon light source and narrow-band interference filters are coupled to a 20-gauge endoilluminator and a 35-mm camera mounted on a surgical microscope. The system was tested with good success in a patient undergoing penetrating keratoplasty. An 18- to 22-microJ flash of 2 milliseconds' duration is achieved, which is well below the safety threshold level. This new stroboscopic light source provides a flash of sufficient light intensity to perform high-resolution, high-contrast fluorescein angiography during operations for the removal of opacified media.

Aged

Corneal surface morphology following excimer laser ablation with humidified gases.

OBJECTIVE: To compare the effects of blowing dry (nitrogen or helium) and humidified gases over the corneal surface during photorefractive keratectomy. METHODS: Excimer laser myopic ablations were performed on porcine eyes (10 per group) using humidified and dry nitrogen and helium gas under ambient conditions. Surface smoothness was quantified with light and electron microscopy. RESULTS: Corneas that were ablated using humidified gas were smooth and equivalent to those ablated under ambient conditions. Dry nitrogen and helium blowing resulted in increased surface irregularity evident on light and electron microscopy (P < .001). The pseudomembranes in the humidified gas and ambient air groups had fewer surface discontinuities than did those in the nonhumdified gas groups and appeared to have a thinner electron-dense surface layer. CONCLUSIONS: The blowing of humidified gas during excimer laser corneal ablation produces a smoother surface than does the blowing of dry gas and is comparable to that produced under ambient (no blowing) conditions. Maintaining corneal moisture is important in photorefractive keratectomy. If blowing gas is necessary to remove debris from the surface, the gas should be humidified.

Animals

Arachidonic acid metabolites after excimer laser corneal surgery.

OBJECTIVE: We investigated early mediators of inflammation following excimer laser ablation in a rabbit cornea model. The ability of topical anti-inflammatory agents to influence these responses was also examined. METHODS: Adult New Zealand white rabbits were subjected to photorefractive keratectomy with a 193-nm argon fluoride excimer laser. Prostaglandin E2 and leukotriene B4 levels were measured using an enzyme immunoassay, and leukocyte infiltration was determined histologically. RESULTS: Prostaglandin E2 production was rapid and sustained, but we were unable to detect the presence of leukotriene B4. Relative to control, postoperative topical diclofenac sodium treatment caused a significant decrease in prostaglandin E2 levels and a significant increase in corneal leukocytes at 10 hours. Fluorometholone treatment did not significantly alter prostaglandin E2 levels but markedly depressed leukocyte ingress. CONCLUSIONS: Diclofenac reduces prostaglandin E2 levels but not leukocyte infiltration in the cornea following photorefractive keratectomy and thus may be useful clinically to reduce postsurgical pain.

Animals

Photography of shock waves during excimer laser ablation of the cornea. Effect of helium gas on propagation velocity.

Shadow photography of shock waves excited by means of a xenon chloride excimer laser was performed to determine the shock wave propagation velocity in air, nitrogen and helium. Energy densities between 500 and 2,000 mJ/cm2 were used to ablate a rotating rubber cylindrical target and porcine corneas. In ablating the rubber cylinder, a shock wave velocity of 3.3 km/s was generated in air and nitrogen at 40 ns; this decreased to 1.4 km/s at 320 ns. When helium was blown on the target, the velocity increased by a factor of approximately two, to 5.9 km/s at 40 ns and 2.7 km/s at 320 ns. We suggest that blowing helium on the surface of the cornea during excimer laser ablation may speed the dissipation of high-energy acoustic waves and gaseous particles, and thus reduce the exposure and transfer of heat energy to the surrounding tissue.

Animals

Photokeratitis from 193 nm argon-fluoride laser radiation.

The threshold for photokeratitis at 193 nm was obtained for the rabbit cornea using an ArF excimer laser. Because ablation occurs at a level below that for photokeratitis, it was necessary to expose the cornea to a lengthy series of low-energy exposures. It is concluded that the 193 nm photons have such a shallow penetration depth, being limited to the outermost epithelial cells, that classical photokeratitis occurs from the fluorescence emitted at the corneal epithelial absorption site. An intact tear film may help to protect the cornea from low-level, scattered 193 nm laser radiation.

Animals