Search PubMed⌕ Search

Biomedical subjects

R R Gonzalez

Publications and source records attributed to R R Gonzalez.

At least 37 records · Page 2Linked to original sources

Thermoregulatory responses to cold: effects of handwear with multi-layered clothing.

BACKGROUND: Thermoregulatory responses were studied during rest and exercise in men wearing diverse handwear with an extended cold-weather clothing system [ECWCS]. The ECWCS (thermal insulation = 3.6 clo (1 clo = thermal resistance approximately 0.155 m2.K.W(-1)); weight = 10.1 kg) incorporates skin-tight polypropylene underwear, polyester/cotton fatigues, polyester-insulated liners, balaclava, vapor-barrier boots, and polytetrafluroethylene [PTFE]-lined outer garments. METHODS: Six fit males each rested (M = 71 W.m(-2) and performed treadmill exercise (M = 171 W.m(-2)) while wearing the following handwear with the ECWCS: a light duty glove (LD, clo = 0.86), a heavy duty glove (HD, clo = 1.05), or an Arctic mitten (AM, clo = 1.46). Cold exposures were at Ta = 0 degrees C, -20 degrees C, and -30 degrees C; rh = 20%; wind speed = 10.34 m.s(-1). Exposure was a target period of 120 min designated as maximal endurance time (ET, min). All experiments were performed on separate days. Rectal (Tre), middle finger (Tmf), and mean weighted skin (Tsk) temperatures were recorded continuously; oxygen uptake and heart rate were measured periodically and total body weight loss msw, g.h(-1)) was determined after each run. RESULTS: During rest at 0 degrees C, the ECWCS maintained Tre at 37 degrees C for the maximal ET with all handwear configurations; for each lower ambient condition, steady-state Tre dropped -0.2 degrees C per each 10 C decrease in Ta.Tmf at or near 5 degrees C prior to the maximal ET was the basis for premature attrition; Tsk of 29.4 degrees C was associated with subjective thermal discomfort. ET was predicted adequately by combining Tmf, heat production, Tre and Tsk. CONCLUSIONS: The ECWCS with specific handwear furnish adequate ET in cold-dry ambients provided that ventilation and removal of extra layers is an option during heavy exercise and thermal insulation is not decreased by body moisture.

Adult↗

Endothelium-dependent vascular smooth muscle relaxation activated by electrical field stimulation.

Electrical field stimulation (EFS) produced relaxation of contracted arteries in the presence of tetrodotoxin. In the present study the contributions of vascular smooth muscle repolarization and endothelial release of nitric oxide to the relaxation response were investigated using isolated rat tail arteries and bovine aortic endothelial cells (BAEC). Intact and endothelium-denuded rings or intact, pressurized artery segments were contracted with either phenylephrine or KCl prior to EFS. Electrical field stimulation induced a small relaxation in denuded, phenylephrine contracted rings that was inhibited by the K+ channel blockers glibenclamide and BaCl2. In intact, phenylephrine-contracted rings, EFS induced significantly larger relaxations that were inhibited by BaCl2 as well as by L-NAME, an inhibitor of nitric oxide (NO) synthase, and methylene blue. EFS-induced relaxations were completely inhibited when BaCl2 and L-NAME or methylene blue were combined. Exposure to Ca(2+)-free buffer or diltiazem also inhibited the relaxation while ascorbic acid had no effect. Effluent from electrically stimulated BAEC caused denuded, phenylephrine contracted rings to relax. The ability of the effluent to cause relaxation was almost completely blocked by exposure of the BAEC to L-NAME or exposure of the recipient vascular smooth muscle to methylene blue; glibenclamide caused partial blockade. Simultaneous measurements of membrane potential and intraluminal pressure showed that EFS-induced membrane repolarization preceded changes in steady-state pressure. It is concluded that (1) the smooth muscle cells possess an endothelium-independent repolarization mechanism, (2) EFS causes endothelial cells of intact arteries to release NO and possibly a hyperpolarizing factor, (3) EFS of BAEC causes release of NO, and (4) EFS-induced relaxation depends on vascular smooth muscle cell membrane repolarization and endothelial cell release of vasoactive substances.

Animals↗

Numerical analysis of an extremity in a cold environment including countercurrent arterio-venous heat exchange.

A model of the thermal behavior of an extremity, e.g., a finger, is presented. The model includes the effects of heat conduction, metabolic heat generation, heat transport by blood perfusion, heat exchange between the tissue and the large blood vessels, and arterio-venous heat exchange. Heat exchange with the environment through a layer of thermal insulation, depicting thermal handwear, is also considered. The tissue is subdivided into four concentric layers simulating, from the center outward, core, muscle, fat, and skin. Differential heat balance equations are formulated for the tissue and for the major artery and the major vein traversing the finger. These coupled equations are solved numerically by a finite-difference, alternating direction method employing a Thomas algorithm. The numerical scheme was extensively tested for its stability and convergence. This paper presents the model equations and results of the convergence tests, and shows plots of blood and tissue temperatures along the axis of the model for combinations of parameters including the effect of countercurrent heat exchange between the artery and the vein.

Algorithms↗

Heat strain models applicable for protective clothing systems: comparison of core temperature response.

Core temperature (Tc) output comparisons were analyzed from thermal models applicable to persons wearing protective clothing. The two models evaluated were the United States (US) Army Research Institute of Environmental Medicine (USARIEM) heat strain experimental model and the United Kingdom (UK) Loughborough (LUT25) model. Data were derived from collaborative heat-acclimation studies conducted by three organizations and included an intermittent-work protocol (Canada) and a continuous-exercise/heat stress protocol (UK and US). Volunteers from the US and the UK were exposed to a standard exercise/heat stress protocol (ambient temperature 35 degrees C/50% relative humidity, wind speed 1 m/s, level treadmill speed 1.34 m/s). Canadian Forces volunteers did an intermittent-work protocol (15 min moderate work/15 min rest at ambient temperature of 40 degrees C/30% relative humidity, wind speed approximately 0.4 m/s). Each model reliably predicted Tc responses (within the margin of error determined by 1 root mean square deviation) during work in the heat with protective clothing. Models that are analytically similar to the classic Stolwijk-Hardy model serve as robust operational tools for prediction of physiological heat strain when modified to incorporate clothing heat-exchange factors.

Acclimatization↗

Applications of predictive environmental strain models.

Researchers at the U.S. Army Research Institute of Environmental Medicine have developed and validated numerical models capable of predicting the extent of physiologic strain and adverse terrain and weather-related medical consequences of military operations in harsh environments. A descriptive historical account is provided that details how physiologic models for hot and cold weather exposure have been integrated into portable field advisory devices, computer-based meteorologic planning software, and combat-oriented simulation systems. It is important that medical officers be aware of the existence of these types of decision support tools so that they can assure that outputs are interpreted in a balanced and medically realistic manner. Additionally, these modeling applications may facilitate timely preventive medicine planning and efficient dissemination of appropriate measures to prevent weather- and altitude-related illnesses and performance decrements. Such environmental response modeling applications may therefore be utilized to support deployment preventive medicine planning by field medical officers.

Algorithms↗

Lumped-parameter tissue temperature-blood perfusion model of a cold-stressed fingertip.

A lumped-parameter model of a fingertip is presented. The semispherical model includes the effects of heat storage, heat exchange with the environment, and heat transport by blood perfusion. The thermal insulation on the surface of the fingertip is represented by the overall heat transfer coefficient that is calculated by common engineering formulas. The model is solved analytically for the simple case of constant blood perfusion rate. The general case of variable blood perfusion rates is solved by an Euler finite difference technique. At this stage, the model does not include active control mechanisms of blood perfusion. Thus the effects of cold-induced vasodilatation have to be superimposed and are modeled by symmetrical triangular waveforms because these were found to best depict the behavior of fingers exposed to cold environments. Results of this model were compared with experimental data obtained in two separate studies. One included 60-min infrared thermograms of the dorsal surface of bare hands of sedentary subjects horizontally suspended on a fish net in a 0 degree C environment. Another study, on gloved finger temperatures, involved 0 and -6.7 degrees C environments. Fingertip (nail bed) temperatures of both these studies were compared with model predictions. Blood perfusion rates were assumed and adjusted within physiologically reasonable limits. Comparison of measured and computed temperature records showed very good conformity in both cases studied.

Body Temperature Regulation↗

Metabolic and thermal adaptations from endurance training in hot or cold water.

Metabolic and thermal adaptations resulting from endurance training in hot vs. cold water were compared. It was hypothesized that training in hot water would have greater effects on muscle glycogen use and blood lactate accumulation during exercise than training in cold water. Eighteen men exercised at 60% of maximal oxygen uptake while immersed in hot (n = 9) or cold water (n = 9) for 1 h, 5 days/wk, for 8 wk. Training in hot water (35 degrees C) potentiated body temperature increases during exercise, and training in cold water (20 degrees C) blunted body temperature increases during exercise. Before and after training, cardiorespiratory and thermoregulatory responses and muscle glycogen and blood lactate changes were assessed during a 1-h exercise trial in hot water and, on a separate day using the same intensity, in cold water. Oxygen uptake was similar for all trials, averaging 2.0 +/- 0.1 l/min. It was observed that 1) training reduced glycogen use and lactate accumulation during exercise, with no difference between cold and hot water training groups in the magnitude of this effect; 2) lactate accumulation during exercise was the same in hot water as in cold water; and 3) skin temperature decreased more rapidly during cold-water exercise after than before training, with no difference between cold and hot water training groups in the magnitude of this effect. Thus, exercise-induced body temperature increases are not an important stimulus for glycogen-sparing effects and blunted lactate accumulation associated with endurance training.

Adaptation, Physiological↗

Predicting human heat strain and performance with application to space operations.

This Institute has developed a USARIEM Heat Strain Prediction Model for predicting physiological responses and soldier performance in the heat, which has been programmed for use by hand-held calculators and personal computers, and incorporated into the development of a heat strain decision aid. This model is demonstrated to predict accurately (generally within +/- 1 SD/SEM) rectal temperature (Tre) responses for soldiers wearing various military clothing ensembles during U.S. or non-U.S. military scenarios in the heat at home or abroad. The value of this model is shown presently for three NASA scenarios involving the Launch and Entry Suit (LES). The LES (ventilated or unventilated) is modeled during pre-launch/launch, re-entry/landing, and emergency egress after re-entry/landing scenarios, predominately to evaluate heat acclimation and hydration state effects. During the pre-launch/launch scenario, predicted final Tre closely agrees with observed values suggesting minimal heat strain (Tre approximately 38.0 degrees C). In contrast, dehydrated (3%) unacclimated individuals show moderate levels of heat strain (Tre approximately 38.5 degrees C) for this same scenario. During the re-entry/landing and emergency egress scenarios, dehydrated unacclimated individuals are predicted to exhibit excessive heat strain (Tre > 39.0 degrees C). Thermal tolerance time is predicted to be only 6 min during emergency egress if individuals are dehydrated and unacclimated to heat while wearing the LES. If heat transfer values for space operations clothing are known, NASA can use this prediction model to help avoid undue heat strain involving astronauts for most scenarios during spaceflight.

Acclimatization↗

Human thermoregulatory responses during heat exposure after artificially induced sunburn.

Thermoregulatory responses in the heat (ambient temperature 49 degrees C, 20% relative humidity, 1 m/s wind) were investigated in 10 unacclimated men during 50 min of cycle ergometer exercise (approximately 53% of maximal aerobic power) after a 10-min rest before as well as 24 h and 1 wk after twice the minimal erythemal dose of UV-B radiation that covered approximately 85% of the body surface area. In 7 subjects esophageal temperature (Tes) was recorded while in all 10 subjects five-site skin and rectal temperatures, heart rate, and back, left forearm, and shielded (12 cm2 area) right forearm sweating rates (msw) were recorded at 15-s intervals. Venous blood was collected before and after exercise-heat stress. Mean skin temperature, Tes, rectal temperature, heart rate, and total body sweating rate were not significantly (P greater than 0.05) affected by sunburn. Pre- and postexercise values of hematocrit, hemoglobin, plasma protein, plasma volume, and plasma osmolality were also not affected (P greater than 0.05) by sunburn. Analysis of presunburn and post-sunburn data showed that the Tes intercept for sweating (degrees C) was unaffected (P greater than 0.05), but msw/Tes and final msw from the left forearm (msw/Tes 0.24 +/- 0.02 vs. 0.17 +/- 0.01 mg.cm-2.min-1. degrees C-1, P less than 0.05; msw 0.60 +/- 0.05 vs. 0.37 +/- 0.02, mg.cm-2.min-1, P less than 0.05) and back (msw/Tes 0.43 +/- 0.03 vs. 0.36 +/- 0.01 mg.cm-2.min-1. degrees C-1, P = 0.052; msw 1.08 +/- 0.09 vs. 0.74 +/- 0.05 mg.cm-2.min-1, P less than 0.05) were significantly reduced 24 h postsunburn.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

An enzyme immunoassay for determining total thyroxine in human serum using an ultramicroanalytical system.

A simple, rapid competitive ultramicroElisa assay has been developed for the measurement of total thyroxine (T4) using only 10 microliters of serum. Our novel UME is based on fluorescence measurements of the hydrolytic product of 4-methyl-umbelliferyl-beta-D-galactopyranoside. T4-beta-Galactosidase conjugates and monoclonal antibodies were immobilized on polyvinyl plates, with sodium salicylate used as a blocking agent for thyroxine binding protein. The analytical steps were carried out using a semiautomated batch-assay system entitled "SUMA" (system for ultramicroanalysis). The T4 assay was completed in 2 h, with a measuring range of 24-386 nmol/L. The intra-assay coefficient of variation (CV) was 4.6-6.9% and the inter-assay C.V. 9.0-12.4% depending on the T4 concentrations. Percentage recovery ranged from 99.2-111%. Regression analysis showed a good correlation with an established radioimmunoassay (n = 121, r = 0.946, P less than 0.01).

Antibodies, Monoclonal↗

Color modulation of Doppler spectra with the use of a personal computer.

This paper describes a method for the use of a personal computer in developing color modulated spectral maps of blood flow echoes from a Doppler flowmeter. The acoustical signal from a Doppler flowmeter is digitized and transformed into the frequency domain with a fast Fourier technique with the use of an Apple IIe microcomputer in conjunction with a Motorola 68000 co-processor. The resultant transform is displayed as a pseudo three-dimensional, color modulated spectral map by way of a color monitor, or a television projector onto the meeting room screen. We have found this technique to be useful in appreciating differences in blood flow from different hydraulic conditions, as well as in helping the medical students appreciate these differences in pulsatile flow in various arteries.

Color↗

Physiological consequences of intermittent exercise during compensable and uncompensable heat stress.

Time-weighted averaging is a traditional method used in heat stress analyses to approximate, in terms of a single continuous level of heat production, the rate of heat production from complex intermittent exercise patterns. Physiological responses during intermittent and continuous exercise were studied in four subjects exposed to heat stress in which evaporation was either free or severely restricted. Intermittent work consisted of repeated 10-min exercise-rest patterns. Continuous work was at the time-weighted average of intermittent exercise: 3.3 mets. When heat stress was uncompensable, intermittent work induced more physiological strain than continuous work: endurance time was 14 min less (P less than 0.05); core temperature at 60 min was 0.40 degrees C higher (P less than 0.05); and, after 30 min of exposure, the rate of core temperature rise was 33% greater. The difference in the rate of heat storage was not satisfactorily explained by a discrepancy in the average rate of heat production or in the calculated rate of surface heat loss. Alternatively, the results may be partially explained by interruptions in the usual rate of heat transport via the cutaneous circulation. These interruptions may be caused by nonthermal factors associated with postural and work load transitions. Although the mechanisms are not totally understood, it is clear that application of the time-weighted averaging method can lead to erroneous overprediction of endurance time and should be applied with discretion.

Adult↗

Quantification of conservative endurance times in thermally insulated cold-stressed digits.

The estimation of endurance times of the digits exposed to cold weather is performed by an analytical, one-dimensional cylindrical model. Blood perfusion effects are lumped into a volumetric heat-generation term. Cold-induced vasodilatation (CIVD) effects are not included in the present analysis. Endurance times, defined by a drop in cylinder tip temperature to 5 degrees C, were evaluated. Parameters included in this evaluation were 1) environmental temperatures, 2) thermal insulation applied on the cylinder, 3) length of the cylinder, and 4) diameter of the cylinder. It was found that the lower the ambient temperature, the longer the finger, and the smaller its diameter, then the shorter the endurance time for the same thermal insulation. Results of the model were compared with measured data for a subject not exhibiting CIVD response to cold stress. Conformity of results calculated for an adjusted value of the volumetric heat-generation term and measured data was very good, with a maximum deviation of less than 10% at only one particular point in time. This model facilitates the conservative estimation of lower bounds to thermally insulated fingers and toes exposed to cold stress.

Body Temperature Regulation↗

Direct solid-phase time-resolved fluoroimmunoassay of 17 alpha-hydroxyprogesterone in serum and dried blood spots on filter paper.

We describe a direct, solid-phase time-resolved fluoroimmunoassay (TRFIA) for measuring 17 alpha-hydroxyprogesterone (17OHP) in serum and blood spots on filter paper. We used 17OHP-3-carboxymethyloxime (17OHP3CMO) coupled to polylysine as the label, which enabled incorporation of up to 34 atoms of europium per molecule of 17OHP, for a very high specific activity. The assay is based on competition between labeled 17OHP3CMO and 17OHP in blood specimens for polyclonal rabbit anti-17OHP antibodies. The antibody-label complex is separated by binding to anti-rabbit antibodies coated onto microtiter strips. The assay buffer contains danazol to displace 17OHP from steroid-binding proteins in serum. For serum samples, the assay is accomplished in 1 h of incubation at room temperature. The blood spot assay with filter paper discs involves incubation overnight at 4 degrees C. Results for both types of specimens from the same subjects correlated well. The lowest measurable concentrations of 17OHP (nmol/L) were 0.10 (3 SD) and 0.75 (3 SD) for serum and dried blood on filter paper, respectively. Intra- and interassay CVs were about 5-15% for both types of samples.

17-alpha-Hydroxyprogesterone↗

Circadian variations in plasma renin activity, catecholamines and aldosterone during exercise in women.

Four women were studied at 0400 h and 1600 h to determine if their hormonal and hemodynamic responses to exercise varied with the circadian cycle. Esophageal temperature was measured during rest and exercise (60% peak VO2; 30 min) in a warm room (Ta = 35 degrees C; PH2O = 1.7 kPa). Venous blood samples were drawn during rest and exercise and hemoglobin concentration (Hb), hematocrit (Hct), plasma osmolality (Posm), plasma protein concentration (Pp), colloid osmotic pressure (COP), plasma renin activity (PRA), cortisol, aldosterone, norepinephrine (NE) and epinephrine (E) were determined. Changes in plasma volume (PV) were estimated from changes in Hb and Hct. The relative hemoconcentration (-11.2%) was similar at 0400 h and 1600 h, but the absolute PV was smaller at 1600 h than at 0400 h (p = 0.03). The responses of Posm, Pp and COP to exercise were unaffected by time of day. Although PRA was not different at the two times of day, PRA was 244% greater during exercise at 1600 h, but only 103% greater during exercise at 0400 h. The normal circadian rhythms in plasma aldosterone (p = 0.043) and plasma cortisol (p = 0.004) were observed. Plasma aldosterone was 57% greater during exercise, while plasma cortisol did not change. The change in E and NE was greater at 0400 h, but this was due to the lower resting values of the catecholamines at 0400 h. These data indicate that time of day generally did not affect the hormonal or hemodynamic responses to exercise, with the exception that PRA was markedly higher during exercise at 1600 h compared to 0400 h.

Adult↗

Control of thermoregulatory sweating during exercise in the heat.

The purposes of this study were the following: 1) to determine whether erythrocyte infusion alters the control of thermoregulatory sweating and 2) to demonstrate how increases and decreases of both plasma tonicity and blood volume influence the thermoregulatory control parameters of threshold temperature and sweating sensitivity. Six non-heat-acclimated and five heat-acclimated males attempted heat stress tests (HSTs) both before and shortly after (48-96 h) autologous erythrocyte infusion. The non-heat-acclimated subjects were euhydrated for both HSTs, whereas the heat-acclimated subjects were studied in a euhydrated and a hypohydrated (-5% body wt) condition both pre- and postinfusion (500 ml of solution containing approximately 60% hematocrit of autologous erythrocytes). The HSTs consisted of treadmill exercise (335 W.m-2) in a hot (35 degrees C, 45% relative humidity) environment, and esophageal temperature and local sweating rate were continuously measured during 25 min of exercise. These experiments resulted in a matrix of conditions where both plasma tonicity and blood volume were increased or decreased relative to control conditions (euhydration, preinfusion). The findings concerning thermoregulatory sweating during exercise in the heat were summarized as follows: 1) acute polycythemia decreases the threshold temperature and increases the sweating sensitivity, 2) both threshold temperature and sweating sensitivity are increased or decreased from control levels dependent on the combined influence of plasma tonicity and blood volume, and 3) equations are presented that describe how plasma tonicity and blood volume alter threshold temperature and sweating sensitivity values.

Acclimatization↗

Human intravascular immunoglobulin responses to exercise-heat and hypohydration.

Several investigators have suggested that prolonged exercise and hypohydration alter the intravascular mass of immunoglobulins. Those studies, however, have methodological concerns which make generalizations from their data very tenuous. This study examined the effects of prolonged moderate intensity exercise in the heat and hypohydration on changes in the intravascular mass of immunoglobulins. Five heat-acclimated males attempted two Heat Stress Tests (HSTs). One HST was completed when subjects were euhydrated and the other HST when subjects were hypohydrated (-5% from base line body weight). The HSTs consisted of 30 min of rest in a 20 degrees C antechamber, followed by a 120-min exposure (2 repeats of 15 min rest and 45 min walking) in a hot (35 degrees C, 45% rh) environment. The following observations were made concerning immunoglobulin responses to hypohydration and exercise-heat stress: a) the changes in concentrations (mg.dl-1) of the measured immunoglobulins were often a reflection of changes in the plasma volume; b) hypohydration increased the intravascular mass (g) of the complement enzyme C3 during resting conditions, but did not alter the intravascular mass of IgG, IgA, and IgM, and c) prolonged treadmill exercise in the heat, when either euhydrated or hypohydrated, did not alter the intravascular mass of IgG, IgA, IgM, and C3. These data indicate that the intravascular mass of immunoglobulins does not change during prolonged moderate intensity exercise in the heat, and that hypohydration results in a translocation of C3 to the intravascular space. In addition, these data indicate that immunoglobulins do not provide a stress index for hypohydration.

Adult↗

Polycythemia and hydration: effects on thermoregulation and blood volume during exercise-heat stress.

We studied the effects of autologous erythrocyte infusion on thermoregulation and blood volume during exercise in the heat. Specifically, we wanted to determine whether heat-acclimated subjects, as well as hypohydrated subjects, would have a thermoregulatory advantage from acute polycythemia during exercise in the heat. Five heat-acclimated males attempted four heat stress tests (HSTs): two pre- and two postinfusion. Autologous erythrocyte infusion was accomplished with 500 ml of a NaCl-glucose-phosphate solution containing approximately 60% hematocrit. One HST, both pre- and postinfusion, was done while subjects were euhydrated, and one HST was done while subjects were hypohydrated (-5% of body wt). After 30 min of rest in a 20 degrees C antechamber, the HST consisted of a 120-min exposure (2 repeats of 15 min rest and 45 min walking) in a hot (35 degrees C, 45% relative humidity) environment. The findings concerning acute polycythemia in heat-acclimated subjects are summarized: 1) polycythemia increased (P less than 0.05) sweating rate and reduced (P less than 0.01) core temperature during exercise-heat stress for both euhydrated and hypohydrated subjects; 2) the erythrocyte infusion caused an increased (P less than 0.05) plasma volume and increased (P less than 0.01) blood volume; 3) the increased plasma volume was associated with an increased (P less than 0.05) total circulating protein mass; 4) the increased total circulating protein mass tended to better maintain plasma volume when hypohydrated; and 5) heat acclimation may increase extravascular protein mass. Therefore, it is concluded that erythrocyte infusion provides a thermoregulatory advantage during exercise in the heat for heat acclimated subjects when both euhydrated and hypohydrated.

Acclimatization↗