In vitro mechanical properties and failure mode of the equine (pony) cranial cruciate ligament.

In vitro failure modes and mechanical properties of the equine cranial cruciate ligament (CCL) were evaluated in 15 stifle joints from 10 ponies. Ponies were from 3 to 25 years of age and weighed from 122 to 208 kg. Femur-CCL-tibia specimens were mounted in 48 degrees of flexion, distracted until a 500-g tensile preload was achieved, and then tested by tensile loading to failure. Specimens failed by complete midsubstance CCL rupture (n = 9), combined tibial insertion avulsion fracture and midsubstance CCL rupture (n = 4), and combined femoral origin avulsion fracture and midsubstance CCL rupture (n = 2). No significant differences were found between CCL mechanical properties and failure mode or body weight. Femur-CCL-tibia maximum tensile loads ranged from 1,945 to 4,326 N (median, 2,914 N). Mean maximum tensile load (N) per kilogram of body weight was 17.98 N/kg (median, 17.55 N/kg). These pony specimens had stiffer cranial cruciate ligaments (median, 320.2 N/mm) with a higher elastic modulus (median, 321.7 MPa) than has been reported for other species. Significant decreases in linear tensile load (P = .0292), maximum tensile load (P = .0493), and increases in strain to maximum load (P = .0463) were found in the specimens from 20- to 25-year-old ponies when compared with those from 3- to 10-year-old ponies.

Aging↗

Comparison of soccer shin guards in preventing tibia fracture.

The goal of this study was to evaluate the effectiveness of a number of shin guards in protecting against tibia fracture in soccer players. A secondary purpose was to determine the relationship between the material and structural differences in shin guard design and the protection provided. Twenty-three commercially available shin guards were tested on a model leg containing a synthetic tibia that had been calibrated against human cadaver specimens. Each guard was categorized into one of four material types: plastic (N = 9), fiberglass (N = 6), compressed air (N = 4), and Kevlar (N = 4). The maximum combined force at the ends of the tibia, the principal strain on the posterior side of the tibia, and the contact time of the impact were measured using a drop track impact simulation. Shin guards provided significant protection from tibia fracture at all drop heights. The average guard reduced force by 11% to 17% and strain by 45% to 51% compared with the unguarded leg. At the higher drop heights, material composition and structural characteristics of the shin guards showed significant differences in protective abilities. These findings indicate that all shin guards provide some measure of protection against tibia fracture, although the level of protection may vary significantly among the different guards.

Adult↗

Anterior cruciate ligament allograft transplantation. Long-term function, histology, revascularization, and operative technique.

In recent years much effort has been devoted to finding a satisfactory replacement for the injured ACL. None of the reconstruction techniques used in the past can be considered ideal because of their inability to duplicate the complex geometry, structure, and function of the ligament. Current advances in allograft transplantation and cryopreservation have led us to design and implement an experimental model for testing the feasibility of cryopreserved ACL allotransplantation. Groups of dogs were used to evaluate the effect of cryopreservation on ligament strength and to compare the relative performance of both autograft and allograft ACL transplants up to 18 months after implantation. The ligaments were examined mechanically, histologically, and microangiographically. The cryopreservation process and duration of storage had no effect on the biomechanical or structural properties of the ligament. The mechanical integrity of the allografts was similar to that of the autografts, with both achieving nearly 90% of control ligament strength by 36 weeks. Revascularization approached normal by 24 weeks in both autograft and allograft. No evidence of structural degradation or immunological reaction was seen. Based on these results, we believe that a cryopreserved ACL allograft can provide the ideal material for ACL reconstruction. We have outlined a surgical technique for harvesting and implanting this graft clinically.

Animals↗

Biomechanical and histological evaluation of muscle after controlled strain injury.

This study correlates force generation and healing in muscle after controlled strain injury. Right tibialis anterior (TA) muscles from 30 rabbits were strained to approximately 80% of failure while the left TA muscles served as control. Both injured and control muscles were then tested for ability to generate force. Seven animals were sacrificed immediately after testing and the muscles were examined grossly and histologically. Remaining animals were retested at 24 hours (N = 7), 48 hours (N = 8), and 7 days (N = 8). Contractile ability following injury was 70.5% of control immediately, 51.1% at 24 hours, 74.5% at 48 hours, and 92.5% at 7 days. Immediate histology showed limited distal fiber rupture and hemorrhage. By 24 hours, histology showed fiber necrosis, infiltration of inflammatory cells, edema, and hemorrhage. At 48 hours there was complete fiber breakdown and intense inflammatory cell proliferation. At 7 days inflammation was reduced and collagen fibrosis more advanced. Our findings demonstrate that injured muscle begins functional recovery by 48 hours despite inflammation and active healing. This suggests that decreasing muscle function seen clinically between 24 and 48 hours following strain injury may result from pain due to inflammation. Scarring and fibrosis seen at 7 days may explain the frequent recurrence of injury to strained muscles.

Animals↗

Biomechanical comparison of stimulated and nonstimulated skeletal muscle pulled to failure.

We compared the biomechanical properties of passive and stimulated muscle rapidly lengthened to failure in an experimental animal model. The mechanical parameters compared were force to tear, change in length to tear, site of failure, and energy absorbed by the muscle-tendon unit before failure. Paired comparisons were made between 1) muscles stimulated at 64 Hz (tetanic stimulation) and passive (no stimulation) muscles, 2) muscles stimulated at 16 Hz (wave-summated stimulation) and passive muscles, and 3) muscles stimulated at 64 Hz and at 16 Hz. Both tetanically stimulated and wave-summation contracted muscles required a greater force to tear (at 64 Hz, 12.86 N more, P less than 0.0004; and at 16 Hz, 17.79 N more, P less than 0.003) than their nonstimulated controls, while there was no statistical difference in failure force between muscles stimulated at 16 Hz and 64 Hz. The energy absorbed was statistically greater for the stimulated muscles than for the passive muscles in Groups 1 and 2 (at 64 Hz, 100% more, P less than 0.0003; and 16 Hz, 88% more, P less than 0.0002). In Group 3, the tetanically contracted muscle-tendon units absorbed 18% more energy than the wave-summated stimulated muscles (P less than 0.01). All muscles tore at the distal musculotendinous junction, and there was no difference in the length increase at tear between muscles in each group. These findings may lead to enhanced understanding of the mechanism and physiology of muscle strain injuries.

Animals↗

The effect of muscle architecture on the biomechanical failure properties of skeletal muscle under passive extension.

This study investigates the biomechanical failure properties of five architecturally different skeletal muscles and examines the role muscle structure plays in the passive extension characteristics of musculotendinous units. The muscles used in this study fall into four morphologic categories: fusiform, unipennate, bipennate, and multipennate. Each muscle was pulled to failure at three different rates of strain (1, 10, and 100 cm/min). Specimens of fusiform, unipennate, and bipennate muscles were pulled from their proximal as well as distal attachments. The relationship of elongation to failure of the entire musculotendinous unit to resting muscle fiber length was examined to determine the effect of angle of pennation and fiber length on the failure properties. Our results demonstrate that all four muscle types tested show injury and rupture at the musculotendinous junction whether pulled from proximal or distal attachment, regardless of muscle structure and rate of strain. There was a statistically significant difference (P less than 0.005) in the degree of elongation to failure relative to resting muscle fiber length, with a tendency to greater elongation relative to fiber length for muscles with more pennate structure (tibialis anterior, 72.7% +/- 1.0%; extensor digitorum longus, 113.1% +/- 3.5%; rectus femoris, 225.5% +/- 3.7% elongation in percent resting fiber length).

Animals↗

The role of warmup in muscular injury prevention.

This study is an attempt to provide biomechanical support for the athletic practice of warming up prior to an exercise task to reduce the incidence of injury. Tears in isometrically preconditioned (stimulated before stretching) muscle were compared to tears in control (nonstimulated) muscle by examining four parameters: 1) force and 2) change of length required to tear the muscle, 3) site of failure, and 4) length-tension deformation. The tibialis anterior (TA), the extensor digitorum longus (EDL), and flexor digitorum longus (EDL) muscles from both hindlimbs of rabbits comprised our experimental model. Isometrically preconditioned TA (P less than 0.001), EDL (P less than 0.005), and FDL (P less than 0.01) muscles required more force to fail than their contralateral controls. Preconditioned TA (P less than 0.05), EDL (P less than 0.001), and FDL (P less than 0.01) muscles also stretched to a greater length from rest before failing than their nonpreconditioned controls. The site of failure in all of the muscles was the musculotendinous junction; thus, the site of failure was not altered by condition. The length-tension deformation curves for all three muscle types showed that in every case the preconditioned muscles attained a lesser force at each given increase in length before failure, showing a relative increase in elasticity, although only the EDL showed a statistically significant difference. From our data, it may be inferred that physiologic warming (isometric preconditioning) is of benefit in preventing muscular injury by increasing the and length to failure and elasticity of the muscle-tendon unit.

Animals↗

The role of fatigue in susceptibility to acute muscle strain injury.

We investigated the role of fatigue in muscle strain injuries using the extensor digitorum longus muscles of 48 rabbits. The muscles of the rabbits were fatigued by 25% or 50% then stretched to failure and compared with the contralateral controls. Three rates of stretch were used. The force to muscle failure was reduced in the fatigued leg in all groups (range, 93% to 97.4% compared with the controls). The change in muscle length in the fatigue groups was not different from the controls. The amount of energy absorbed in the fatigued muscle was 69.7% to 92% that of the energy absorbed in the control muscle. The lowest energy absorption occurred in muscles that were more fatigued. In eight additional rabbits, fatigued extensor digitorum longus muscles were compared with submaximally stimulated muscles with the equivalent contractile properties, and no difference was seen. Muscles subjected to strains are frequently injured under high-intensity eccentric loading conditions. Under these conditions, muscles absorb energy and provide control and regulation of limb movement. Our data showed that muscles are injured at the same length, regardless of the effects of fatigue. However, fatigued muscles are able to absorb less energy before reaching the degree of stretch that causes injuries.