Search PubMed⌕ Search

Biomedical subjects

R R Edelman

Publications and source records attributed to R R Edelman.

At least 55 records · Page 3Linked to original sources

Signal-to-noise ratio and signal-to-noise efficiency in SMASH imaging.

A general theory of signal-to-noise ratio (SNR) in simultaneous acquisition of spatial harmonics (SMASH) imaging is presented, and the predictions of the theory are verified in imaging experiments and in numerical simulations. In a SMASH image, multiple lines of k-space are generated simultaneously through combinations of magnetic resonance signals in a radiofrequency coil array. Here, effects of noise correlations between array elements as well as new correlations introduced by the SMASH reconstruction procedure are assessed. SNR and SNR efficiency in SMASH images are compared with results using traditional array combination strategies. Under optimized conditions, SMASH achieves the same average SNR efficiency as ideal pixel-by-pixel array combinations, while allowing imaging to proceed at otherwise unattainable speeds. The k-space nature of SMASH reconstructions can lead to oscillatory spatial variations in noise standard deviation, which can produce local enhancements of SNR in particular regions.

Abdomen↗

Resolution enhancement in single-shot imaging using simultaneous acquisition of spatial harmonics (SMASH).

Spatial resolution in single-shot imaging is limited by signal attenuation due to relaxation of transverse magnetization. This effect can be reduced by minimizing acquisition times through the use of short interecho spacings. However, the minimum interecho spacing is constrained by limits on gradient switching rates, radiofrequency (RF) power deposition and RF pulse length. Recently, simultaneous acquisition of spatial harmonics (SMASH) has been introduced as a method to acquire magnetic resonance images at increased speeds using a reduced number of phase-encoding gradient steps by extracting spatial information contained in an RF coil array. In this study, it is shown that SMASH can be used to reduce the effects of relaxation, resulting in single-shot images with increased spatial resolution without increasing imaging time. After a brief theoretical discussion, two strategies to reduce signal attenuation and increase spatial resolution in single-shot imaging are introduced and their performance is evaluated in phantom studies. In vivo single-shot echoplanar imaging (EPI), BURST, and half-Fourier single-shot turbo spin-echo (HASTE) images are then presented demonstrating the practical implementation of these resolution enhancement strategies. Images acquired with SMASH show increased spatial resolution and improved image quality when compared with images obtained with the conventional acquisitions. The general principles presented for imaging with SMASH can also be applied to other partially parallel imaging techniques.

Computer Simulation↗

Quantitative assessment of pulmonary perfusion with dynamic contrast-enhanced MRI.

The feasibility of qualitative assessment of pulmonary perfusion using dynamic contrast enhanced MRI with ultra-short TE has recently been demonstrated. In the current study, quantitative analysis was attempted based on the indicator dilution principle using a pig model of pulmonary embolism. The results were compared with the absolute pulmonary perfusion obtained with colored microspheres. The inverse of apparent mean transit time (1/tau(app)), distribution volume (V), and V/tau(app) were correlated well with the absolute lung perfusion. This study demonstrates that MR has the potential to evaluate pulmonary perfusion quantitatively. Magn Reson Med 42:1033-1038, 1999.

Adult↗

Central nervous system abnormalities assessed with prenatal magnetic resonance imaging.

OBJECTIVE: To determine the frequency at which magnetic resonance imaging (MRI) provides additional information in fetuses with suspected central nervous system (CNS) abnormalities on ultrasound. METHODS: Between May 1, 1996, and March 26, 1999, 83 women with 90 fetuses (including seven sets of live twins) had 91 ultrasonographic and MRI examinations of the fetal CNS. Eight women were studied twice, one for two different indications. If referrals came from outside our institution, a confirmatory sonogram was obtained. Indications for examination were ventriculomegaly (n = 25), suspected neural tube defect (n = 16), arachnoid cyst (n = 12), large cisterna magna (n = 11), and miscellaneous indications (n = 20). RESULTS: Magnetic resonance imaging findings led to changed diagnoses in 26 (40%) of 66 fetuses with abnormal confirmatory sonograms. Magnetic resonance imaging findings not found by ultrasound included partial or complete agenesis of the corpus callosum (n = 11), porencephaly (n = 6), hemorrhage (n = 5), tethered cord (n = 3), cortical gyral abnormality (n = 2), cortical cleft (n = 2), midbrain abnormality (n = 2), and partial or complete agenesis of the septi pellucidi (n = 3), as well as holoprosencephaly, cerebellar hypoplasia, subependymal and cortical tubers, vascular malformation, and vermian cysts (one case each). Abnormalities better delineated by MRI than ultrasound included three cephaloceles, a dural arteriovenous malformation, one distal sacral neural tube defect, and the mass effect of three arachnoid cysts. That information was used to alter patient counseling and at times management. CONCLUSION: When a CNS anomaly is detected by sonography or suspected on ultrasound, MRI findings might lead to altered diagnosis and patient counseling.

Central Nervous System↗

Magnetic resonance imaging of the thorax. Past, present, and future.

Magnetic resonance is a valuable modality of extreme flexibility for specific problem-solving capability in the thorax. This article reviews MR applications in the imaging of great vessels, which are currently the most important applications in the thorax; other established applications in the thorax; and pulmonary functional MR imaging.

Aortic Diseases↗

MR imaging of pulmonary parenchyma with a half-Fourier single-shot turbo spin-echo (HASTE) sequence.

OBJECTIVE: To evaluate the utility of a half-Fourier single-shot turbo spin-echo sequence (HASTE) at depicting lung parenchyma and lung pathology. METHODS AND PATIENTS: A HASTE sequence was applied to five normal volunteers and 20 patients with various pulmonary disorders to depict the lung parenchyma. Images were acquired with ECG-triggering and breath-holding. In three volunteers, signal intensity measurements from lung parenchyma were performed using four sequences: (a) HASTE; (b) conventional spin echo; (c) fast spin echo; and (d) gradient echo. T2 maps were produced using the HASTE acquisition. RESULTS: Minimal respiratory or cardiac motion artifacts were observed. The signal-to-noise ratios from lung parenchyma were 27.8 +/- 5.4, 22.0 +/- 3.0, 15.3 +/- 0.9, and 6.0 +/- 1.9 for HASTE, spin-echo, fast spin-echo, and gradient echo sequences, respectively. The scan time for HASTE was 302 ms for each slice. The T2 values in the right lung and the left lung were 61.2 +/- 4.1 and 79.1 +/- 8.9 ms in systole and 92.6 +/- 5.8 and 97.5 +/- 12.2 ms in diastole, respectively (P < 0.05 diastole versus systole). The HASTE sequence demonstrated clearly various pulmonary disorders, including lung cancer, hilar lymphadenopathy, metastatic pulmonary nodules as small as 3 mm, pulmonary hemorrhage, pulmonary edema and bronchial wall thickening in bronchiectasis. CONCLUSION: Our preliminary results indicate that the HASTE sequence provides a practical means for breath-hold MR imaging of lung parenchyma.

Adult↗

Magnetic resonance T2* measurements of the normal human lung in vivo with ultra-short echo times.

The objective of this study was to measure T2* values of the normal human lung in vivo during breathhold using a rapid gradient-echo sequence with ultra-short echo times (TE). A sagittal slice of the right lung was imaged in six volunteers with various TE ranging from 0.5 ms to 5 ms using a clinical 1.5 Tesla MR scanner. T2* values were calculated in a region of interest in the dependent and non-dependent lung. In the dependent lung, T2* values of 1.1 ms+/-0.15 ms were measured, and in the non-dependent lung, 0.86 ms+/-0.11 (p < 0.01). T2* measurements of the normal human lung during breathhold are feasible with a clinical MR unit. The short T2* values require the use of very short TE times (< 2.5 ms) in gradient-echo sequences to obtain adequate signal intensity from lung tissue.

Adult↗

First-pass renal perfusion imaging using MS-325, an albumin-targeted MRI contrast agent.

RATIONALE AND OBJECTIVES: MR angiography is proving to be a useful clinical study for the diagnosis of vascular disorders of renal arteries. However, its utility in terms of stenosis characterization is still limited. Renal perfusion could provide supplemental information that could allow for a comprehensive evaluation of renal artery stenosis by MR imaging. METHODS: MS-325 is a small-molecule blood pool agent that reversibly binds with serum albumin and hence leads to higher relaxivity and longer residence times in the blood. In this study, the authors evaluated the use of MS-325 to perform first-pass perfusion imaging and contrast-enhanced MR angiography in the characterization of renal artery stenosis in an animal model. RESULTS: Quantitative perfusion estimates were obtained in the renal cortex (258 +/- 19.8 mL/min/100 g) and are comparable to microsphere measurements (198 +/- 12.2 mL/min/100 g), given the practical constraints. Based on these measurements, perfusion showed minimal changes even when the diameter reductions reached 75%. CONCLUSIONS: MS-325 could provide quantitative perfusion estimates that when combined with MR angiography may lead to comprehensive evaluation of renal artery stenosis.

Animals↗

Obstetric MR imaging.

The surge in the development of fast magnetic resonance (MR) techniques has revolutionized our ability to image the pregnant patient and the fetus. Fast MR imaging techniques provide excellent resolution for imaging the maternal and fetal anatomies without the need for sedation. This article addresses the use of fast MR imaging techniques in the evaluation of the pregnant patient for adnexal masses, pelvimetry, hydroureteronephrosis of pregnancy, and placenta accreta. In addition, fetal anomalies for which MR imaging has proved useful, such as ventriculomegaly, arachnoid cysts, and abdominal masses, are described.

Female↗

Pulmonary disorders: ventilation-perfusion MR imaging with animal models.

PURPOSE: To demonstrate the capability of magnetic resonance (MR) imaging to assess alteration in regional pulmonary ventilation and perfusion with animal models of airway obstruction and pulmonary embolism. MATERIALS AND METHODS: Airway obstruction was created by inflating a 5-F balloon catheter into a secondary bronchus. Pulmonary emboli were created by injecting thrombi into the inferior vena cava. Regional pulmonary ventilation was assessed with 100% oxygen as a T1 contrast agent. Regional pulmonary perfusion was assessed with a two-dimensional fast low-angle shot, or FLASH, sequence with short repetition and echo times after intravenous administration of gadopentetate dimeglumine. RESULTS: Matched ventilation and perfusion abnormalities were identified in all animals with airway obstruction. MR perfusion defects without ventilation abnormalities were seen in all animals with pulmonary emboli. CONCLUSION: Ventilation and perfusion MR imaging are able to provide regional pulmonary functional information with high spatial and temporal resolution. The ability of MR imaging to assess both the magnitude and regional distribution of pulmonary functional impairment could have an important effect on the evaluation of lung disease.

Airway Obstruction↗

Relationship between motion of coronary arteries and diaphragm during free breathing: lessons from real-time MR imaging.

OBJECTIVE: Diaphragmatic navigators are frequently used in free-breathing coronary MR angiography, either to gate or prospectively correct slice position or both. For such approaches, a constant relationship between coronary and diaphragmatic displacement throughout the respiratory cycle is assumed. The purpose of this study was to evaluate the relationship between diaphragmatic and coronary artery motion during free breathing. SUBJECTS AND METHODS: A real-time echoplanar MR imaging sequence was used in 12 healthy volunteers to obtain 30 successive images each (one per cardiac cycle) that included the left main coronary artery and the domes of both hemidiaphragms. The coronary artery and diaphragm positions (relative to isocenter) were determined and analyzed for effective diaphragmatic gating windows of 3, 5, and 7 mm (diaphragmatic excursions of 0-3, 0-5, and 0-7 mm from the end-expiratory position, respectively). RESULTS: Although the mean slope correlating the displacement of the right diaphragm and the left main coronary artery was approximately 0.6 for all diaphragmatic gating windows, we also found great variability among individual volunteers. Linear regression slopes varied from 0.17 to 0.93, and r2 values varied from .04 to .87. CONCLUSION: Wide individual variability exists in the relationship between coronary and diaphragmatic respiratory motion during free breathing. Accordingly, coronary MR angiographic approaches that use diaphragmatic navigator position for prospective slice correction may benefit from patient-specific correction factors. Alternatively, coronary MR angiography may benefit from a more direct assessment of the respiratory displacement of the heart and coronary arteries, using left ventricular navigators.

Adult↗

Echoplanar MR imaging for ultrafast detection of brain lesions.

OBJECTIVE: We retrospectively evaluated the use of echo-planar imaging for ultrafast detection of brain lesions. MATERIALS AND METHODS: In our retrospective study, 61 patients were imaged with the following echo-planar sequences: single-shot proton density-weighted, single-shot T2-weighted, single-shot T2-weighted high-resolution, multishot proton density-weighted, and multishot T2-weighted. Lesions revealed in these patients ranged from 0.5 to 12.0 cm (mean, 3.7 cm) and were the result of tumor (n = 16), stroke (n = 21), demyelination (n = 18), and toxoplasmosis (n = 2). Four patients had scans with normal findings. Two neuroradiologists who were unaware of pertinent clinical data reviewed the images. The images were retrospectively compared with conventional spin-echo images for diagnosis, sensitivity of lesion detection, and qualitative criteria: subjective image quality, gray and white matter differentiation, lesion conspicuity, delineation of lesion borders, and artifacts. (Artifacts included those caused by motion, susceptibility, pulsation, and ghosting.) Quantitative criteria, including signal-to-noise and signal difference-to-noise measurements, were also evaluated in 40 lesions. RESULTS: Sensitivity for lesion detection was 97% for single-shot echo-planar T2-weighted MR images and 100% for multishot echo-planar T2-weighted MR images. Single-shot echo-planar proton density-weighted MR images had the highest signal-to-noise ratio (91.2+/-19.3). Echo-planar T2-weighted MR images had the highest signal difference-to-noise (33.8+/-22.9). Echo-planar sequences were superior to spin-echo sequences regarding motion and pulsation artifacts. Spin-echo sequences lacked susceptibility and ghosting artifacts, and were superior in lesion conspicuity and delineation of lesion borders. CONCLUSION: In this study, echo-planar sequences were as sensitive as conventional spin-echo imaging for the diagnostic assessment of lesions. Echo-planar sequences had a strikingly shorter acquisition time and substantially reduced motion and pulsation artifacts. Echo-planar sequences may be a useful diagnostic tool for use in claustrophobic and unstable patients.

Adult↗

Accelerated cardiac imaging using the SMASH technique.

SMASH (SiMultaneous Acquisition of Spatial Harmonics) was recently introduced as a novel rapid-imaging technique. The SMASH technique uses a partially parallel acquisition strategy, using spatial information from a radiofrequency coil array to accelerate imaging. This study constitutes the first application of SMASH to cardiac magnetic resonance imaging. The increased imaging speed provided by SMASH was used to obtain images with reduced breathhold duration, enhanced spatial resolution, and increased temporal resolution in healthy volunteers. The results obtained demonstrate the feasibility and potential clinical utility of cardiac magnetic resonance imaging using the SMASH technique.

Feasibility Studies↗

Ventilation-perfusion MR imaging of the lung.

The assessment of regional ventilation in human lungs is important for the diagnosis and evaluation of a variety of pulmonary disorders, including pulmonary emphysema, diffuse lung disease (e.g., sarcoidosis, and pulmonary fibrosis), lung cancer, and pulmonary embolism. This article introduces new MR imaging techniques of pulmonary ventilation and perfusion that will provide a framework for assessing regional pulmonary functions of the lung.

Adult↗

A general kinetic model for quantitative perfusion imaging with arterial spin labeling.

Recently, several implementations of arterial spin labeling (ASL) techniques have been developed for producing MRI images sensitive to local tissue perfusion. For quantitation of perfusion, both pulsed and continuous labeling methods potentially suffer from a number of systematic errors. In this study, a general kinetic model for the ASL signal is described that can be used to assess these errors. With appropriate assumptions, the general model reduces to models that have been used previously to analyze ASL data, but the general model also provides a way to analyze the errors that result if these assumptions are not accurate. The model was used for an initial assessment of systematic errors due to the effects of variable transit delays from the tagging band to the imaging voxel, the effects of capillary/tissue exchange of water on the relaxation of the tag, and the effects of incomplete water extraction. In preliminary experiments with a human subject, the model provided a good description of pulsed ASL data during a simple sensorimotor activation task.

Arousal↗

Functional burst imaging.

A quiet magnetic resonance (MR) imaging technique for detecting changes in cerebral activity functions is presented. This single-shot method, functional Burst imaging (FBI), combines elements of Burst imaging with an offset technique known as asymmetric spin echo (ASE). The FBI sequence has the unique feature of being nearly silent, because of the low number of gradient switching steps involved. Furthermore, this approach has the key advantage that it can be implemented on conventional MR systems. Established auditory and visual paradigms were used to evaluate whether FBI can detect changes in cerebral activity using a 1.5 Tesla MR system. In a second set of experiments, the FBI technique was used to evaluate cerebral activity changes during different sleep stages in humans. The results obtained demonstrate that the FBI sequence provides an alternative approach for functional imaging of brain activity in primary and secondary sensory areas of the human brain. Furthermore, in using this quiet MR technique, it was possible to scan continuously during different stages of human sleep without acoustic noise perturbation.

Acoustic Stimulation↗