[(Quantitative) diagnosis of myocardial infarction using colored areal mapping electro-cardiography].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to R Nohara.
Explore the source record for details and available documents.
It is well known that vitamin K deficiency is an important cause of the spontaneous intracranial hemorrhage in infancy. A 60-day-old male infant with spontaneous intracerebral hematomas due to vitamin K deficiency was presented. He was breast-fed. He had been medicated oral antibiotic agent for diarrhea and fever. Three days later he developed petechien, vomiting and twitching, and became drowsy. The blood studies showed anemia, and advance of ESR. He was administered of vitamin K immediately. CT scan was showed four intracerebral hematomas with niveau, which were surrounded by high-density rings. The ring-like figures were unique for this case. The reason may be next, we think. Under the states in which blood can separate easily with advance of ESR, blood clot would adhere to the wall of the hematomas. So these hematomas showed ring-like figures and had niveau in them. CT scan of this case was also interesting because there was little deviation in spite of the big hematomas. The reason of this may be that the brain of infancy is incomplete in myelination and contains much water, and that the possibility of bleeding due to vitamin K occurs slowly. We examined 84 cases of intracranial hemorrhage due to vitamin K deficiency from literatures, and they were all identified for the hemorrhage sites by CT scan. Subarachnoidal hemorrhage was in 72 cases (85.7%), subdural hemorrhage was in 41 cases (48.8%), intracerebral hematomas was in 36 cases (42.9%) and intraventricular hemorrhage was in 9 cases (10.7%). In 52 cases the CT findings were described.(ABSTRACT TRUNCATED AT 250 WORDS)
To detect and evaluate regurgitant flow in tricuspid regurgitation (TR) with a newly developed, realtime, 2-dimensional (2-D), color-coded, Doppler flow imaging system (Doppler 2-D echo), 27 patients (18 with suspected TR and 9 normal subjects) were examined and the findings were compared with those obtained using contrast 2-D echocardiography (contrast 2-D echo) and right ventriculography. In 16 of 18 patients with suspected TR, Doppler 2-D echo easily visualized the color-coded regurgitant flow in the right atrium and estimated the severity of TR from the distance of the visible TR jet. On the basis of the QRS synchronized appearance of contrast in the inferior vena cava by the subxiphoid approach or of the negative contrast effect above the tricuspid valve just after the contrast entered the right ventricle with its subsequent back-and-forth movements across the tricuspid valve, Doppler 2-D echo was more sensitive and specific in detecting TR (100% and 100%) than contrast 2-D echo (75% and 82% in the subxiphoid view, 56% and 100% in the 4-chamber view) when the fast Fourier transformation frequency analysis was used as the standard of TR, and it was more sensitive in detecting TR (85%) than contrast 2-D echo (69% in the subxiphoid approach, 46% in the 4-chamber view) when right ventriculography was used as the standard of TR. Additionally, the severity of TR as shown by Doppler 2-D echo correlated fairly well with that shown by right ventriculography. Thus, Doppler 2-D echo is clinically useful for detecting and evaluating TR.
A multigated blood-pool study was performed to assess regional and global emptying and filling in 16 patients with hypertrophic cardiomyopathy (HCM), 43 patients with ischemic heart disease (IHD), and 14 controls. The regional volume curve was fitted using second-order harmonics in the Fourier series, while the global left-ventricular volume curve was fitted using third-order harmonics. As asynchronous indices, the standard deviations (SD) in distribution histograms of time to end-systole (TES), time to peak ejection (TPE), and time to peak filling (TPF) were obtained in the left ventricle. In patients with IHD, the TPF-SD was higher (14.4 +/- 11.3 degrees) than the TES-SD (7.8 +/- 5.1 degrees) and TPE-SD (8.1 +/- 5.9 degrees), suggesting the presence of asynchronous filling. In patients with HCM, the TPF-SD was also higher (11.6 +/- 11.1 degrees) than the TES-SD (3.5 +/- 2.4 degrees) and TPE-SD (6.2 +/- 4.4 degrees). The phase delay was localized in the anteroseptal or apical region in all 5 HCM patients with abnormal wall motion, while it corresponded with the region of abnormal wall motion in the patients with IHD. The TPF-SD was inversely correlated with the left-ventricular ejection fraction (r = -0.46), peak filling rate (r = -0.50), and the ratio of peak filling rate to peak ejection rate (r = -0.52), suggesting that asynchronous filling is related to global diastolic disturbance. We conclude that asynchronous filling is often present in patients with IHD and HCM, and that our technique can be used to obtain a quantitative assessment of regional asynchronous emptying and filling in these diseases.
The effect of low sensitivity areas or gaps between adjacent slices of the multislice positron emission tomography on detection of myocardial perfusion abnormality with 13NH3 was evaluated segmentally in 36 patients with coronary artery disease at rest or during exercise. The detectability of the defects in RCA or LAD region was 80% in single-position scans in stress studies. The false-negative defects were located mainly in the inferior wall, apicoinferior wall, or high anterior wall. When the patients were moved half the slice interval to perform the interpolating scan, and the two sets of images were interlaced with each other, the detectability increased to 88%. The interpolating scan also allowed reconstruction of long-axis and short-axis tomograms in high quality, which further improved the detectability of perfusion defects (100% for RCA or LAD and 75% for LCX lesion) and helped in understanding the anatomic relationships to the coronary artery territories.
Explore the source record for details and available documents.
The early distribution of thallium-201 (Tl-201) is related to blood flow within the limits of the physiological range. We examined the ratio of myocardial uptake of Tl-201 to the total dose administered at rest and during exercise, in order to assess myocardial blood flow. The usual dose of Tl-201 (2-3 mCi) was diluted to 20 ml of normal saline and 15 ml were injected intravenously as a bolus. Subsequently the remaining 5 ml were injected in the same manner. Myocardial Tl-201 uptakes after the first dose were comparable to those of the second dose at rest when myocardial uptake immediately before the second injection was subtracted and multiplied by 3 (r = 0.98). This technique was applied during exercise to evaluate coronary reserve. Symptom-limited exercise was performed using a sitting ergometer and the first dose of Tl-201 was administered. After the routine scintigraphy with multiple views was completed, a second dose was given at rest. Myocardial uptake was greater during exercise than at rest by 32.6 +/- 15.1% (mean +/- SD) in 18 normal subjects. This was significantly greater than that of 20 patients with coronary artery disease (5.8 +/- 15.3%; p less than 0.005). Tl-201 scintigraphy has inherent limitations as to its quantitation, while positron scintigraphy using 13N-NH3 has some advantages for calculations. Percent myocardial uptake of 13N during exercise was practically equal to that at rest in six normal subjects (97.1 +/- 25.0%), but it was slightly reduced in patients with coronary artery disease (90.1 +/- 18.2%).(ABSTRACT TRUNCATED AT 250 WORDS)
To assess regional cardiac function in patients with ischemic heart disease (IHD), multigated blood-pool studies using higher-order harmonics of the Fourier series were performed for 14 normal persons and 37 patients with IHD. IHD was further divided into IHD (I) (EF greater than or equal to 50%) and IHD (II) (EF less than 50%). A pixel-by-pixel volume curve was simulated using second order harmonics of the Fourier series to create functional images of the following parameters: time to endosystole (TES), peak ejection rate (PER), time to PER (TPE), peak filling rate (PFR), and time to PFR (TPF). TES (SD), TPE (SD), and TPF (SD) were calculated as the standard deviations of left ventricular (LV) histograms of each phase, representing indexes of asynchronous wall motion. An LV volume curve was simulated using third order harmonics to calculate PFR, PFR/PER, and TPF/TPE, representing indexes of diastolic function. TES (SD) was abnormal in 10 cases (50%), and TPE (SD) was abnormal in seven cases (35%) of IHD (II). On the contrary, TPF (SD) was abnormal in three cases (18%) of IHD (I) and 15 cases (75%) of IHD (II), indicating that diastolic asynchronous indexes are more sensitive than systolic asynchronous indexes in detecting IHD. IHD (I) and IHD (II) showed lower PFR (2.32 +/- 0.55, 1.64 +/- 0.46 EDV/sec) and lower PFR/PER (0.84 +/- 0.15, 0.68 +/- 0.26) than those in normals (3.25 +/- 0.98 EDV/sec, 0.99 +/- 0.19), respectively.(ABSTRACT TRUNCATED AT 250 WORDS)
To evaluate the noninvasive detection of shunt flow using a newly developed real-time 2-dimensional color-coded Doppler flow imaging system (D-2DE), 20 patients were examined, including 10 with secundum atrial septal defect (ASD) and 10 control subjects. These results were compared with contrast 2-dimensional echocardiography (C-2DE). Doppler 2DE displayed the blood flow toward the transducer as red and the blood flow away from the transducer as blue in 8 shades, each shade adding green according to the degree of variance in Doppler frequency. In the patients with ASD, D-2DE clearly visualized left-to-right shunt flow in 7 of 10 patients. In 5 of these 7 patients, C-2DE showed a negative contrast effect in the same area of the right atrium. Thus, D-2DE increased the sensitivity over C-2DE for detecting left-to-right shunt flow (from 50% to 70%). However, the specificity was slightly less in D-2DE (90%) than C-2DE (100%). Doppler 2DE could not visualize right-to-left shunt flow in all patients with ASD, though C-2DE showed a positive contrast effect in the left-sided heart in 9 of 10 patients with ASD. Thus, D-2DE is clinically useful for detecting left-to-right shunt flow in patients with ASD.
Changes of septal Q waves in lead V5 by exercise were evaluated with single-photon emission computed tomography. Coronary artery disease was present in 66 patients, 48 of whom had left anterior descending coronary artery (LAD) involvement. Forty-one subjects had normal coronary arteries. All patients under investigation were classified into 3 groups: group A (18 patients)--regression of Q amplitude during exercise; group B (48 patients)--progression or no change of Q wave or a new Q wave during exercise; and group C (41 patients)--no Q waves at rest and during exercise. Perfusion defects of the septum were calculated 3-dimensionally and expressed as a percent of the total septum. Seventeen patients (94%) in group A showed septal perfusion defects by exercise and all of them had LAD stenosis. Forty-three patients (90%) in group B showed no septal perfusion defects, but the others with perfusion defects had LAD stenosis. In group C, 23 of 41 patients (56%) had an LAD lesion, of whom 91% showed septal perfusion defects; none of the remaining 18 patients without LAD stenosis showed perfusion defects. The area of septal perfusion defects during exercise was larger in group A (62 +/- 19%) and in group C (52 +/- 19%) than in group B (23 +/- 9%) (groups A vs B, p less than 0.001; groups C vs B, p less than 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)
The influence of the duration of ischemia on infarct size and left ventricular function (LV) was assessed in 30 patients with a first anterior myocardial infarction (MI) and intracoronary thrombolysis (ICTL) on admission. The occlusion time of the left anterior descending coronary artery (LAD) was 4 hours or less in 11 patients (group I), 4-10 hours in 11 (group II) and 10 hours or more in eight (group III). Serial measurements of serum creatine kinase-MB were carried out during the acute phase. Four weeks after the procedure, electrocardiographic pathological Q waves on 34-lead precordial mapping were scored, viable left ventricular myocardial volume and the ratio of infarcted to total left ventricular myocardial volume was estimated by myocardial emission computed tomography (ECT) with thallium-201. In the acute phase enzymatic estimation of infarct size showed a significant difference between group I and the other two groups but not between groups II and III; there were no significant differences in the degree of left ventricular asynergy among the three groups. In the chronic phase infarct sizes evaluated by both Q wave mapping and ECT were smaller in group I than those in group II, which were smaller than those in group III; there were significant differences in the degree of LV asynergy among the three groups (group I less than II less than III). LV function was nearly normal in group I, moderately impaired in group II, but severely depressed in group III 4 weeks later. The present study indicates that infarct size extends and LV function deteriorates with the duration of occlusion of the LAD and that not only early (less than or equal to 4 hours) but also later (4-10 hours) reperfusion is beneficial to prevent the extension of MI and deterioration of LV function in patients with anterior MI.
Stress thallium-201 emission computed tomography (ECT) was performed for 24 patients with myocardial infarction for quantitative evaluation of regional thallium redistribution and washout. ECT was performed using a rotating gamma camera 10 minutes and 2.5 hours after thallium injection during maximal exercise. Three short-axis sections and one central long-axis section were selected for the circumferential profile curves. Redistribution (%) and washout (%) were calculated from the stress and redistribution profile curves in each section. These parameters were evaluated by comparison with regional wall motion on radiographic contrast ventriculography. Forty-eight of the 52 segments (92%) with normal thallium uptake showed normal wall motion. Among the segments with abnormal thallium uptake, normal or hypokinetic wall motion was observed in 12 of 13 segments (92%) with more than 20% redistribution and in 16 of 19 segments (84%) with 10-20% redistribution, while it was observed in only 15 of 36 segments (42%) without redistribution (p less than 0.001). Among 48 infarcted segments, 16 segments (33%) showed significant redistribution on ECT analysis. Normal or hypokinetic wall motion was observed in three of five segments (60%) with more than 20% redistribution, and in 10 of 11 segments (91%) with 10-20% redistribution, while it was seen in only eight of 30 segments (17%) without redistribution (p less than 0.005).
Explore the source record for details and available documents.
Twenty-seven patients with angina pectoris, 24 with postmyocardial infarction angina and 7 with normal coronary arteries were examined by exercise thallium-201 emission computed tomography (SPECT) and planar scintigraphy. Exercise SPECT was compared with the reperfusion imaging obtained approximately 2 to 3 hours after exercise. The sensitivity and specificity of demonstrating involved coronary arteries by identifying the locations of myocardial perfusion defects were 96 and 87% for right coronary artery, 88 and 89% for left anterior descending artery (LAD) and 78 and 100% for left circumflex artery (LC). These figures are higher than those for planar scintigraphy (85 and 87% for right coronary artery, 73 and 89% for LAD and 39 and 100% for LC arteries). In patients with 3-vessel disease, sensitivity of SPECT (100, 88 and 75% for right coronary artery, LAD and LC, respectively) was higher than planar imaging (88, 63 and 31%, respectively), with a significant difference for LC (p less than 0.05). In 1, 2 and 0-vessel disease the sensitivity and specificity of the 2 techniques were comparable. Multivessel disease was more easily identified as multiple coronary involvement than planar imaging with a significant difference in 3-vessel disease (p less than 0.05). In conclusion, stress SPECT provides useful information for the identification of LC lesions in coronary heart disease, including 3-vessel involvement.
The configuration of the hypertrophied myocardium was evaluated by thallium-201 emission-computed tomography and 2-dimensional (2-D) sector scan in 10 patients with obstructive hypertrophic cardiomyopathy (HC), 10 with nonobstructive HC with giant negative T waves and 10 with concentric left ventricular (LV) hypertrophy. Thallium-201 myocardial imaging was reconstructed into multiple 12-mm-thick slices in 3 planes. The thickness ratio of the ventricular septum and the LV posterior wall in the short-axis plane and the ratio of the ventricular septum and the apical wall in the long-axis plane were analyzed. In the patients with obstructive HC the ventricular septal wall thickness index was increased, and the ratio of septal to posterior wall thickness index (1.45 +/- 0.23) was greater than that in the patients with nonobstructive HC with giant negative T waves or in those with concentric LV hypertrophy (1.03 +/- 0.20 and 0.98 +/- 0.11, respectively; p less than 0.01 for each). In the patients with nonobstructive HC with giant negative T waves, increased apical wall thickness with apical cavity obliteration was characteristic, and the ratio of ventricular septal to apical wall thickness index (0.66 +/- 0.14) was less than that in the patients with obstructive HC or in those with concentric LV hypertrophy (1.46 +/- 0.38 and 1.04 +/- 0.09, respectively; p less than 0.001 for each). In contrast, technically satisfactory 2-D sector scanning (83%) demonstrated various configurations of the hypertrophied ventricularseptum, but could not detect apical hypertrophy in 4 of the 10 patients with nonobstructive HC with giant negative T waves whose LV cineangiograms demonstrated apical hypertrophy. Thus, thallium-201 emission-computed tomography is useful in evaluating the characteristics of LV hypertrophy and assists 2-D sector scan, especially in patients with apical hypertrophy in HC.
The value of stress thallium 201 myocardial emission computed tomography (ECT) in the assessment of coronary artery disease (CAD) was analyzed in 75 patients admitted for coronary arteriography. The ECT provided contiguous transaxial, short-axis, and long-axis sections of the myocardium and the myocardial images were divided into nine segments. The sensitivity and specificity in the diagnosis of CAD were 95% and 93%, respectively. Using selected segments, the ECT identified 97 of 111 (83%) major vessels involved: 89% for right coronary artery (RCA), 88% for left anterior descending (LAD), and 70% for left circumflex (LCx). Among the 75 cases, 35 underwent stress conventional planar imaging within 3 months. The planar imaging provided high sensitivity (90%) and specificity (100%) for the detection of CAD patients as well, but it showed lower sensitivity (57%, P less than 0.001) in identifying individual vessels involved: 55% for RCA (P less than 0.01), 70% for LAD, and 36% for LCx (P less than 0.05). Stress ECT detected vessel involvement more in two-vessel disease (85%) and three-vessel disease (78%) than the planar imaging (50%: P less than 0.05 and 44%: P less than 0.01, respectively). Thus, segmental analysis of stress ECT yielded as high sensitivity and specificity in the diagnosis of CAD as the planar imaging. This can improve sensitivity in identifying individual vessels involved in deep myocardial regions, especially in those with multivessel disease.
Emission computed tomography with technetium-99m pyrophosphate was used to delineate the location and estimate the size of myocardial infarcts in 20 patients with documented acute myocardial infarction. Tomography was performed after planar imaging within 2-5 days after the onset of infarction. A series of transaxial, frontal, and sagittal tomograms were reconstructed from 32 views imaged from the left side of the patient's chest with a rotating gammacamera. Infarct volume was measured from the tomographic images by computerised planimetry and was compared with the cumulative release of creatine kinase MB isoenzyme. The planar images showed discrete myocardial uptake in 13 of the 20 patients and diffuse uptake throughout the cardiac region in the remaining seven. In contrast, the tomographic images clearly delineated discrete myocardial uptake by avoiding confusion of myocardial activity with that of surrounding structures, particularly bones, in all patients. For the 10 patients whose infarct size was assessed by analysis of the creatine kinase MB curve there was a close correlation between infarct volume estimated by tomography and by cumulative creatine kinase MB release. Thus emission computed tomography can provide a three dimensional map of technetium-99m pyrophosphate distribution within the heart and is thus able accurately to localise and estimate the size of myocardial infarcts in man.
Emission computed tomography with thallium-201 was compared with planar imaging in its ability to detect myocardial infarctions of various sizes four weeks after the onset. Tomography was performed after planar imaging at rest in 160 patients with a first myocardial infarction, in whom infarct size was prospectively estimated by the peak value of creatine kinase activity at the time of the acute episode and in 39 patients without infarction. The planar images and the transaxial, short axial, and long axial tomograms were interpreted qualitatively. Tomography was significantly more sensitive than planar imaging in detecting anterior (87% v 96%), inferior (73% v 97%), and non-transmural (47% v 87%) infarcts. The increased sensitivity was confined to detecting small infarcts as assessed by the peak creatine kinase value (44% v 89% when peak creatine kinase activity was less than or equal to 1000 IU/l). The overall sensitivity was 96% for tomography and 78% for planar imaging. The specificity was similar (92%) with the two techniques. Thus emission computed tomography can improve the detection rate of small infarcts that cannot be identified on planar images, by showing the three dimensional distribution of thallium-201, and increases the diagnostic value of thallium-201 scintigraphy.