Search PubMed⌕ Search

Biomedical subjects

R Nath

Publications and source records attributed to R Nath.

At least 19 recordsLinked to original sources

Relaxation in the glass former acetylsalicylic acid studied by deuteron magnetic resonance and dielectric spectroscopy.

Supercooled liquid and glassy acetylsalicylic acid was studied using dielectric spectroscopy and deuteron relaxometry in a wide temperature range. The supercooled liquid is characterized by major deviations from thermally activated behavior. In the glass the secondary relaxation exhibits the typical features of a Johari-Goldstein process. Via measurements of spin-lattice relaxation times the selectively deuterated methyl group was used as a sensitive probe of its local environments. There is a large difference in the mean activation energy in the glass with respect to that in crystalline acetylsalicylic acid. This can be understood by taking into account the broad energy barrier distribution in the glass.

Journal Article↗

Macular hole surgery without prone positioning.

PURPOSE: To investigate the role of vitrectomy without prone posturing in the anatomic and functional outcome of macular hole surgery (MHS). METHODS: Forty-one consecutive eyes of 41 patients with stage II-IV full-thickness macular holes underwent pars plana vitrectomy and 16% C3F8 tamponade. In 25 cases posturing group (P), subjects were instructed to assume prone positioning for 10 days postoperatively, whereas in 16 cases non-posturing group (NP) patients were advised to avoid lying supine but no other posturing instructions were given. Preoperative, intraoperative and postoperative clinical data were collected, with macular hole closure rate and change in LogMAR visual acuity, contrast sensitivity, metamorphopsia, and 25-Visual Function Questionnaire (VFQ-25) being the primary outcome measures. RESULTS: Over a mean follow-up of 4.21.2 months, anatomical hole closure was noted in 22/25 (88%) and 14/16 (87.5%) in groups P and NP respectively. Visual acuity improved by a mean of eight letters and there was no significant difference in the two groups (P=0.724). Similarly, postoperative prone posturing did not have an effect on the final contrast sensitivity, metamorphopsia, and VFQ-25 composite scores (P=0.238, P=0.472, and P=0.87, respectively). However, eyes in group NP developed significantly more severe cataract in the early postoperative period (P=0.02). CONCLUSIONS: Prone posturing following MHS provides no functional or anatomic benefit but it is associated with slower progression of cataract. Combined phacovitrectomy without face down positioning may be considered for all phakic patients undergoing MHS.

Aged↗

Dose rate constant of a cesium-131 interstitial brachytherapy seed measured by thermoluminescent dosimetry and gamma-ray spectrometry.

The aim of this work was to conduct an independent determination of the dose rate constant of the newly introduced Model CS-1 131Cs seed. A total of eight 131Cs seeds were obtained from the seed manufacturer. The air-kerma strength of each seed was measured by the manufacturer whose calibration is traceable to the air-kerma strength standard established for the 131Cs seeds at the National Institute of Standards and Technology (1 sigma uncertainty < 1%). The dose rate constant of each seed was measured by two independent methods: One based on the actual photon energy spectrum emitted by the seed using gamma-ray spectrometry and the other based on the dose-rate measured by thermoluminescent dosimeter (TLD) in a Solid Water phantom. The dose rate constant in water determined by the gamma-ray spectrometry technique and by the TLD dosimetry are 1.066 +/- 0.064 cGyh(-1)U(-1) and 1.058 +/- 0.106 cGyh(-1)U(-1), respectively, showing excellent agreement with each other. These values, however, are approximately 15% greater than a previously reported value of 0.915 cGyh(-1)U(-1) [Med. Phys. 31, 1529-1538 (2004)]. Although low-energy fluorescent x rays at 16.6 and 18.7 keV, originating from niobium present in the seed construction, were measured in the energy spectrum of the 131Cs seeds, their yields were not sufficient to lower the dose rate constant to the value of 0.915 cGyh(-1)U(-1). Additional determinations of the dose rate constant may be needed to establish an AAPM recommended consensus value for routine clinical use of the 131Cs seed.

Brachytherapy↗

Amifostine and autologous hematopoietic stem cell support of escalating-dose melphalan: a phase I study.

This study was conducted to define a new maximum tolerated dose and the dose-limiting toxicity (DLT) of melphalan and autologous hematopoietic stem cell transplantation (AHSCT) when used with the cytoprotective agent amifostine. Fifty-eight patients with various types of malignancy who were ineligible for higher-priority AHSCT protocols were entered on a phase I study of escalating doses of melphalan beginning at 220 mg/m(2) and advancing by 20 mg/m(2) increments in planned cohorts of 4 to 8 patients until severe regimen-related toxicity (RRT) was encountered. In all patients, amifostine 740 mg/m(2) was given on 2 occasions before the first melphalan dose (ie, 24 hours before and again 15 minutes before). AHSCT was given 24 hours after the first melphalan dose. Melphalan was given in doses up to and including 300 mg/m(2). Hematologic depression was profound, although it was rapidly and equally reversible at all melphalan doses. Although mucosal RRT was substantial, it was not the DLT, and some patients given the highest melphalan doses (ie, 300 mg/m(2)) did not develop mucosal RRT. The DLT was not clearly defined. Cardiac toxicity in the form of atrial fibrillation occurred in 3 of 36 patients treated with melphalan doses >/=280 mg/m(2) and was deemed fatal in 1 patient given melphalan 300 mg/m(2). (Another patient with a known cardiomyopathy was given melphalan 220 mg/m(2) and died as a result of heart failure but did not have atrial fibrillation.) Another patient given melphalan 300 mg/m(2) died of hepatic necrosis. The maximum tolerated dose of melphalan in this setting was thus considered to be 280 mg/m(2), and 27 patients were given this dose without severe RRT. Moreover, 38 patients were evaluable for delayed toxicity related to RRT; none was noted. Tumor responses have been noted at all melphalan doses and in all diagnostic groups, and 21 patients are alive at median day +1121 (range, day +136 to day +1923), including 16 without evidence of disease progression at median day +1075 (range, day +509 to day +1638). Amifostine and AHSCT permit the safe use of melphalan 280 mg/m(2), an apparent increase over the dose of melphalan that can be safely administered with AHSCT but without amifostine. Further studies are needed not only to confirm these findings, but also to define the antitumor efficacy of this regimen. Finally, it may be possible to evaluate additional methods of further dose escalation of melphalan in this setting.

Adult↗

Activity of single-agent melphalan 220-300 mg/m2 with amifostine cytoprotection and autologous hematopoietic stem cell support in non-Hodgkin and Hodgkin lymphoma.

High-dose chemotherapy using melphalan (HDMEL) is an important component of many conditioning regimens that are given before autologous hematopoietic stem cell transplantation (AHSCT). In contrast to the situation in myeloma, and to a lesser degree acute leukemia, only a very limited published experience exists with the use of HDMEL conditioning as a single agent in doses requiring AHSCT for lymphoma, both Hodgkin lymphoma (HL) and especially non-Hodgkin lymphoma (NHL). Thus, we report results of treating 26 lymphoma patients (22 with NHL and four with HL) with HDMEL 220-300 mg/m(2) plus amifostine (AF) cytoprotection and AHSCT as part of a phase I-II trial. Median age was 51 years (range 24-62 years); NHL histology was varied, but was aggressive (including transformed from indolent) in 19 patients, indolent in two patients and mantle cell in one. All 26 patients had been extensively treated; 11 were refractory to the immediate prior therapy on protocol entry and two had undergone prior AHSCT. All were deemed ineligible for other, 'first-line' AHSCT regimens. Of these 26 patients, 22 survived to initial tumor evaluation on D +100. At this time, 13 were in complete remission, including four patients who were in second CR before HDMEL+AF+AHSCT. Responses occurred at all HDMEL doses. Currently, seven patients are alive, including five without progression, with a median follow-up in these latter patients of D +1163 (range D +824 to D +1630); one of these patients had a nonmyeloablative allograft as consolidation on D +106. Conversely, 14 patients relapsed or progressed, including five who had previously achieved CR with the AHSCT procedure. Two patients, both with HL, remain alive after progression; one is in CR following salvage radiotherapy. Six patients died due to nonrelapse causes, including two NHL patients who died while in CR. We conclude that HDMEL+AF+AHSCT has significant single-agent activity in relapsed or refractory NHL and HL. This experience may be used as a starting point for subsequent dose escalation of HDMEL (probably with AF) in established combination regimens.

Adult↗

A neutron dosemeter for nuclear criticality accidents.

A neutron dosemeter which offers instant read-out has been developed for nuclear criticality accidents. The system is based on gels containing emulsions of superheated dichlorodifluoromethane droplets, which vaporise into bubbles upon neutron irradiation. The expansion of these bubbles displaces an equivalent volume of gel into a graduated pipette, providing an immediate measure of the dose. Instant read-out is achieved using an array of transmissive optical sensors which consist of coupled LED emitters and phototransistor receivers. When the gel displaced in the pipette crosses the sensing region of the photomicrosensors, it generates a signal collected on a computer through a dedicated acquisition board. The performance of the device was tested during the 2002 International Accident Dosimetry Intercomparison in Valduc, France. The dosemeter was able to follow the initial dose gradient of a simulated accident, providing accurate values of neutron kerma; however, the emulsion was rapidly depleted of all its drops. A model of the depletion effects was developed and it indicates that an adequate dynamic range of the dose response can be achieved by using emulsions of smaller droplets.

Algorithms↗

Low plasma zinc and iron in pica.

OBJECTIVE: To determine role of trace elements in causation of pica with specific reference to zinc and iron we studied plasma levels of iron (Fe), Zinc (Zn), calcium (Ca) and magnesium (Mg) and blood lead (Pb) levels by atomic absorption spectrophotometer in 31 children with pica (Pica Group) and 60 controls matched for age, sex and nutrition (Control Group) in an observational case and control study in the settings of outpatient clinic of a tertiary care, teaching hospital. METHODS: Data from each group were further stratified by hemoglobin level <9 and >9 g/dl into two subgroups pica-1 and pica-2, and control-1 and control-2 respectively, to control for confounding effect of iron deficiency anemia. RESULTS: The plasma Fe level (mean +/- SD) in children with pica (42.7 +/- 9.2) mg/dl) was about 20% lower than that in controls (51.5 +/- 10.0 mg/dl, p < 0.001). Plasma Zn levels in the pica group (60 +/- 4.4 mg/dl) was about 45% lower than those in controls (110.2 +/- 8.5 mg/dl, p<0.001). Correlation of Zn and Fe levels with pica-related variables such as age at onset, duration and frequency and number of inedible objects ingested was not significant. CONCLUSION: These findings suggest that hypozincemia with low iron levels may be the possible cause of pica and contradict the contention that low levels of plasma Zn and Fe could be an effect of pica.

Calcium↗

Efficacy of plant-produced recombinant antibodies against HCG.

BACKGROUND: Antibody engineering facilitates the construction of different antibody formats [single chain variable fragment (scFv), diabody, full-size chimeric monoclonal antibody] with ease. METHODS: We constructed recombinant antibodies against HCG, which is widely used in pregnancy testing and is also produced by a number of cancers. RESULTS: The recombinant antibodies were transiently expressed in tobacco leaves to levels of up to 40 mg of pure protein per kg fresh leaf weight. Enzyme linked immunosorbent assay (ELISA) and electrophoretic mobility assay (EMSA) confirmed antibody specificity for the beta subunit of beta-HCG. The efficacy was confirmed by inhibiting HCG induced testosterone production by Leydig cells in vitro and by blocking the HCG induced increase in mouse uterine weight in vivo. CONCLUSIONS: Passive immunization with recombinant HCG-specific antibodies may have clinical utility as (i) diagnostic and therapeutic tools for HCG-expressing cancers and (ii) contraceptive measures.

Animals↗

Three-dimensional radiotherapy of head and neck and esophageal carcinomas: a monoisocentric treatment technique to achieve improved dose distributions.

The specific aim of three-dimensional conformal radiotherapy is to deliver adequate therapeutic radiation dose to the target volume while concomitantly keeping the dose to surrounding and intervening normal tissues to a minimum. The objective of this study is to examine dose distributions produced by various radiotherapy techniques used in managing head and neck tumors when the upper part of the esophagus is also involved. Treatment planning was performed with a three-dimensional (3-D) treatment planning system. Computerized tomographic (CT) scans used by this system to generate isodose distributions and dose-volume histograms were obtained directly from the CT scanner, which is connected via ethernet cabling to the 3-D planning system. These are useful clinical tools for evaluating the dose distribution to the treatment volume, clinical target volume, gross tumor volume, and certain critical organs. Using 6 and 18 MV photon beams, different configurations of standard treatment techniques for head and neck and esophageal carcinoma were studied and the resulting dose distributions were analyzed. Film validation dosimetry in solid-water phantom was performed to assess the magnitude of dose inhomogeneity at the field junction. Real-time dose measurements on patients using diode dosimetry were made and compared with computed dose values. With regard to minimizing radiation dose to surrounding structures (i.e., lung, spinal cord, etc.), the monoisocentric technique gave the best isodose distributions in terms of dose uniformity. The mini-mantle anterior-posterior/posterior-anterior (AP/PA) technique produced grossly non-uniform dose distribution with excessive hot spots. The dose measured on the patient during the treatment agrees to within +/- 5 % with the computed dose. The protocols presented in this work for simulation, immobilization and treatment planning of patients with head and neck and esophageal tumors provide the optimum dose distributions in the target volume with reduced irradiation of surrounding non-target tissues, and can be routinely implemented in a radiation oncology department. The presence of a real-time dose-measuring system plays an important role in verifying the actual delivery of radiation dose.

Carcinoma↗

Dosimetric penumbra effects in catheter-based intravascular brachytherapy using a centered photon or beta line source.

Purpose: In catheter-based intravascular brachytherapy, either photon or beta emitters are often used in a linear arrangement so that blood vessels of 10-30 mm lengths can be treated. With a line source, the dose gradient in the radial direction and longitudinal direction depend on the type of radionuclides used in the treatment. The purpose of this study was to investigate the dose fall-off at the edges of a linear source in a blood vessel for different types of photon and beta emitters.Materials/Methods: Dose distributions were calculated on cylindrical blood vessels of various radii. Radioactive sources of 192Ir, 125I, 103Pd, 188Re, 32P, and 90Y/Sr were studied. All the sources were assumed to be in the form of a line. The dose rate at a point in space produced by a radioactive source was computed by integrating the point dose rate kernel of the corresponding radionuclide over the radioactive line. The point dose rate kernel was computed with Monte Carlo simulation of radiation transport. The edge effects were characterized with three newly defined quantities: longitudinal dose uniformity (LDU), effective coverage length (ECL), and margin length (ML). LDU was defined as the ratio of dose at a distance along the long axis of the vessel to the dose at center. ECL was defined as the length over which the LDU was greater than 0.95. ML was defined as half of the length difference between source length L and ECL, which is essentially the length segment at each edge that is covered by the source physical length but is being underdosed.Results: All beta emitters provided more uniform dose distributions and covered a larger portion of blood vessels longitudinally than photon emitters. Typical MLs were 2-3 mm for beta emitters and 4-6 mm for gamma emitters. As the radial depth of the point of interest increased, both the LDU and ECL decreased and ML increased. The ML increased from 2 to 3 mm for beta emitters and from 4 to 6 mm for photon emitters when the radial depth of the point of interest increased from 1.5 to 2.5 mm (typical proximal and distal media points for a 3-mm diameter lumen). The ML increased with increasing source length for all radionuclides. For beta emitters the ML increased initially from 1.5 mm to more than 2.5 mm as source length increased from 5 to 10 mm. When the source length was longer than 15 mm, the ML remains nearly constant, about 3 mm. For photon emitters, ML increased continuously from 1.5 mm to more than 6.0 mm, as source length increased from 5 to 50 mm.Conclusions: A formalism to quantify the dose uniformity along the length of a blood vessel undergoing catheter-based intravascular brachytherapy has been developed. This formalism was used to study the edge effects at the ends of several beta and photon sources. The results indicated that for a centered source the ML at each end due to penumbra effects was about 2 to 3 mm for beta emitters; about 4-6 mm for photon emitters. The ML increases as the radial depth of point of interest in the vessel increases. The ML increases also with increasing source length, especially for photon sources.

Journal Article↗

On the need for massive additional shielding of a catheterization laboratory for the implementation of high dose rate 192Ir intravascular brachytherapy.

Purpose: There is a widespread belief in the cardiology and radiation oncology community that high dose rate 192Ir intravascular brachytherapy cannot be implemented without massive additional shielding of the conventional catheterization labs. The purpose of this work is to show that this is a myth, which is not based on sound radiation protection principles.Methods: Exposure rates in air were calculated for a variety of point and line sources of 192Ir. Exposures per treatment at different distances from the source were calculated for a typical intravascular brachytherapy treatment of a 15-Gy dose at a radial distance of 2 mm from the source and for source lengths in the range of 0 to 10 cm. Additionally, exposure rates outside the catheterization lab were calculated for various lead shielding thicknesses typical of conventional X-ray facilities. These rates were used along with the NCRP recommendations on radiation facility design to assess shielding requirements.Results: For a treatment dose of 15 Gy at 2 mm, the occupational exposure per treatment at 2 m in air without any tissue attenuation or shielding was 7.8 mR for a lesion length of 3.0 cm. This exposure/treatment is independent of the dose rate or the activity of the source. However, it increases as lesion length is increased, increasing from 5.4 to 24.9 mR as lesion length increased from 2 to 10 cm. Exposures in unrestricted areas outside the catheterization lab using the NCRP shielding rationale can be kept below 2 mR per treatment and using appropriate workload, use, and occupancy factors below 2 mR per week.Conclusions: The feasibility of implementing a high dose rate 192Ir intravascular brachytherapy program in a catheterization laboratory is totally independent of the dose rate or the activity of the source. If it is feasible to implement 192Ir brachytherapy in a conventional catheterization lab using low activity 192Ir seeds, then it is also feasible to do so with a high activity 192Ir afterloader.

Journal Article↗

Bilateral nerve grafting during radical retropubic prostatectomy: extended follow-up.

OBJECTIVES: To confirm the benefit of using an interposition sural nerve graft at the time of radical retropubic prostatectomy in an extended series of men with at least 1 year of follow-up. We previously reported the return of erectile function after resection of both cavernous nerves. METHODS: Twenty-eight potent men with clinically localized prostate cancer underwent radical retropubic prostatectomy with deliberate wide bilateral neurovascular bundle resection and the placement of bilateral nerve grafts. Erectile dysfunction questionnaires and patient interviews were completed at 6-month intervals. A minimum of 12 months of follow-up (mean 23 +/- 10 months) was obtained for 23 men (mean age 58 +/- 6 years). A control group of 12 men who underwent bilateral nerve resections, but declined nerve graft placement, was also followed up. RESULTS: Of the 23 men, 6 (26%) had spontaneous, medically unassisted erections sufficient for sexual intercourse with vaginal penetration. An additional 6 men (26%) described "40% to 60%" spontaneous erections (fullness, no rigidity, not able to penetrate). Ten men (43%) had intercourse with sildenafil. No demonstrable erections occurred before 5 months postoperatively. The greatest return of function thus far was observed at 18 months after surgery. CONCLUSIONS: This surgical technique continues to show promise as an advance in prostate cancer surgery. The results of this study demonstrated recovery of erectile function in men who underwent bilateral nerve graft placement during radical retropubic prostatectomy when both cavernous nerves were deliberately resected.

Case-Control Studies↗

Dosimetric characterization of a newly designed encapsulated interstitial brachytherapy source of iodine-125-model LS-1 BrachySeed.

A newly designed encapsulated 125I source has been introduced (Model LS-1 BrachySeed manufactured by DRAXIMAGE Inc.) for interstitial brachytherapy. In this source 125I radionuclide is contained in two ceramic beads positioned at each end of a titanium capsule. The source contains a rod of Pt-Ir, which serves as a radiographic marker for source localization in the patient. Principle photon emissions are 27.4 and 31.0 keV X-rays and a 35.5 keV gamma-ray. The 22.2 and 25.5 keV silver X-rays produced by fluorescence of the silver dopant in the ceramic bead radioisotope carriers, are also emitted. In this work, the dosimetric characteristics of the 125I source were measured with micro LiF TLD chips and dosimetry parameters were characterized based upon the American Association of Physicists in Medicine, Task Group, No. 43 formalism. The corrected 1999 National Institute of Standards and Technology standard for low energy interstitial brachytherapy sources was used to specify the air kerma strength of the sources used in this study. The dose rate constant of the sources was determined to be 1.02+/-0.07 cGy h(-1) U(-1). The radial dose function was measured and was found to be similar to that of the silver-based model 6711 125I source. However, the anisotropy function of the Model LS-1 BrachySeed source is considerably better than that of model 6711 125I source, especially on the points along and close to the longitudinal axis of the source. The BrachySeed model LS-1 provides more isotropic angular dose distribution in tissue than model 6711 125I source. The anisotropy constant for the model LS-1 source was determined to be 1.006, which is considerably better than the value of 0.93 for the model 6711 source.

Anisotropy↗

The novel calpain inhibitor SJA6017 improves functional outcome after delayed administration in a mouse model of diffuse brain injury.

A principal mechanism of calcium-mediated neuronal injury is the activation of neutral proteases known as calpains. Proteolytic substrates for calpain include receptor and cytoskeletal proteins, signal transduction enzymes and transcription factors. Recently, calpain inhibitors have been shown to provide benefit in rat models of focal head injury and focal cerebral ischemia. The present study sought to investigate, in experiment 1, the time course of calpain-mediated cytoskeletal injury in a mouse model of diffuse head injury by measuring the 150- and 145-kDa alpha-spectrin breakdown products (SBDP). Secondly, in experiment 2, we examined the effect of early (20 min postinjury) administration of the novel calpain inhibitor SJA6017 on functional outcome measured 24 h following injury and its effect on posttraumatic alpha-spectrin degradation. Lastly, in experiment 3, we examined the effect of delayed (4 or 6 h postinjury) administration of SJA6017 on 24-h postinjury functional outcome. In experiment 1, isoflurane-anesthetized male CF-1 mice (18-22 g) were subjected to a 750 g-cm weight drop-induced injury and were sacrificed for SBDP analysis at postinjury times of 30 min, and 1, 2, 6, 24 and 48 h (plus sham). In experiments 2 and 3, mice were injured as described, and delivered a single tail vein injection of either SJA6017 (0.3, 1, or 3 mg/kg) or vehicle (administered immediately, 4 or 6 h postinjury [3 mg/kg]). Functional outcome was evaluated in both studies, and, in experiment 2, 24-h postinjury assessment of SBDPs was determined. Following injury, the level of SBDP 145 was significantly different from sham at 24 and 48 h in cortical and at 24 h in the hippocampal tissues and at 48 h in the striatum. Immediate postinjury administration of SJA6017 resulted in a dose-related improvement in 24-h functional outcome (p < 0.05 at 3 mg/kg). Significance was maintained after a 4-h delay of the 3 mg/kg, but was lost after a 6-h delay. Despite improvement in functional outcome at 24 h, SJA6017 did not reduce spectrin breakdown in cortical or hippocampal tissues. These results support a role for calpain-mediated neuronal injury and the potential for a practical therapeutic window for calpain inhibition following traumatic brain injury. However, measurements of regional spectrin degradation may not be the most sensitive marker for determining the effects of calpain inhibition.

Animals↗

A directional dose equivalent monitor for neutrons.

A directional dose equivalent monitor is introduced which consists of a 30 cm diameter spherical phantom hosting a superheated drop detector embedded at a depth of 10 mm. The device relies on the similarity between the fluence response of neutron superheated drop detectors based on halocarbon-12 and the quality-factor-weighted kerma factor. This implies that these detectors can be used for in-phantom dosimetry and provide a direct reading of dose equivalent at depth. The directional dose equivalent monitor was characterised experimentally with fast neutron calibrations and numerically with Monte Carlo simulations. The fluence response was determined at angles of 0, 45, 90, 135 and 180 degrees for thermal to 20 MeV neutrons. The response of the device is closely proportional to the fluence-to-directional dose equivalent conversion coefficient, h'phi (10; alpha, E). Therefore, our monitor is suitable for a direct measurement of neutron directional dose equivalent, H'(10), regardless of angle and energy distribution of the neutron fluence.

Calibration↗

Electronic neutron personal dosimetry with superheated drop detectors.

The prototype of an electronic personal neutron dosemeter based on superheated drop detectors is presented. This battery operated device comprises a neutron sensor, bubble-counting electronics and a temperature controller ensuring an optimal dose equivalent response. The neutron sensor is a 12 ml detector vial containing an emulsion of about 50,000 halocarbon-12 droplets of 100 microns diameter. The temperature controller is a low-power, solid-state device stabilising the emulsion at 31.5 degrees C by means of an etched foil heater. The microprocessor controlled counting electronics relies on a double piezo-electric transducer configuration to record bubble formation acoustically via a comparative pulse-shape analysis of ambient noise and detector signals. The performance of the dosemeter was analysed in terms of the requirements presently developed for neutron personal dosemeters. The detection threshold is about 1 microSv, while the personal dose equivalent response to neutrons in the thermal to 62 MeV range falls within a factor 1.6 of 13 bubbles per microSv.

Consumer Product Safety↗