Search PubMed⌕ Search

Biomedical subjects

R N Zare

Publications and source records attributed to R N Zare.

69 records · Page 4Linked to original sources

Continuous sample collection in capillary zone electrophoresis by coupling the outlet of a capillary to a moving surface.

Use of an on-column frit structure, constructed by sintering a mixture of glass powders, makes it possible to ground a fused-silica capillary on its side prior to its outlet. Electroosmotic pressure permits convenient sample collection. We illustrate the use of this device by depositing the eluent in a continuous manner on a moving surface. This provides a permanent record of the separated species in a mixture.

Chromatography, Thin Layer↗

Determination of methotrexate and its major metabolite, 7-hydroxymethotrexate, using capillary zone electrophoresis and laser-induced fluorescence detection.

High-dosage methotrexate therapy requires careful monitoring of the drug in serum to ensure minimal toxic effects. A simple, rapid and sensitive method for the separation and quantitation of methotrexate and its major metabolite, 7-hydroxymethotrexate, using high-voltage capillary zone electrophoresis combined with laser-induced fluorescence detection is described. The detection limit for methotrexate is as low as 5.10(-10) M (signal-to-noise ratio = 3), while that for 7-hydroxymethotrexate is 2.10(-9) M. The linearity of the system extends over nearly four orders of magnitude for both methotrexate and 7-hydroxymethotrexate. The extraction efficiency for the drug and its metabolite from serum is 80-85% using a Sep-Pak C18 cartridge. Quantitation of methotrexate in serum was possible in the 10(-10) M range, nearly two orders of magnitude lower than that currently obtainable by existing methods. Good correlation (r = 0.99) for serum methotrexate concentrations was obtained with an enzyme-multiplied immunoassay technique. Comparison with an enzyme inhibition assay also provided similar results.

Electrophoresis↗

Femtomole analysis of prostaglandin pharmaceuticals.

An analytical method is described whereby the major classes of prostaglandins are fully resolved by microcolumn liquid chromatography and detected at the subfemtomole level by laser-induced fluorescence. The prostaglandins are labeled with the fluorescent reagent 4-bromo-methyl-7-methoxycoumarin and are subsequently separated on a high-efficiency fused-silica microcolumn (0.2 mm i.d., 1.06 m length, 150,000 theoretical plates). The optimal chromatographic conditions consist of a 3-micron octadecylsilica packing material and an isocratic mobile phase of 47.6% methanol, 23.8% acetonitrile, and 28.6% water. The prostaglandin derivatives are detected directly on the microcolumn by laser fluorimetry, using a helium/cadmium laser (325 nm, 15 mW) as the excitation source together with a simple filter/photo-multiplier optical detection system. In real sample matrices, the prostaglandin PGF2 alpha is readily quantifiable from the detection limit (0.3 fmol) to the formulation strength of the therapeutic agent Lutalyse (Upjohn), spanning more than six orders of magnitude in concentration. The simplicity and general applicability of the present analytical methodology and instrumentation suggest that this technique can be used to attack a wide variety of biomedically important problems with exceptional sensitivity and selectivity.

Arbaprostil↗

Direct measurement of antigens in serum by time-resolved fluoroimmunoassay.

A long-lived fluorescence label (Tb3+) has been attached to the antigen of interest by using a bifunctional chelating agent 1-(p-benzenediazonium)-EDTA. A nonequilibrium competitive-binding immunoassay protocol, in conjunction with time-resolved detection of the long-lived fluorescence label, allows the antigen to be analyzed directly in samples containing diluted human serum. Results obtained for immunoglobulin G with this simple and rapid procedure correlated well (r = 0.93) with those by a commercially available fluorescence immunoassay method.

Antigens↗

Laser chemical analysis.

Selected applications of laser methods to analytical problems are reviewed. Examples are chosen from multiphoton ionization and laser fluorescence analysis. Although efforts to carry out elemental analysis with laser techniques are probably the most advanced, studies suggest that the analysis of molecular species is also quite promising, particularly in regard to interfacing laser fluorimetric detection with high-performance liquid chromatography. Recent experiments indicate that analysts can expect to attain in a number of cases the ultimate limit of single-atom or single-molecule detection with laser-based methods.

Chemistry Techniques, Analytical↗

Enzyme-linked sandwich immunoassay for insulin using laser fluorimetric detection.

Human serum samples are assayed for insulin by an enzyme-linked sandwich immunoassay. Horseradish peroxidase is used as an enzyme label for antibody, and enzyme activity is measured by means of the fluorogenic substrate, p-hydroxyphenylacetic acid. The product is detected by excitation of fluorescence with the 325-nm line of a continuous-wave helium/cadmium ion laser on line with reverse-phase high-pressure liquid chromatography. The incubation period is 90 min and the limit of detection of insulin is 30 pM, corresponding to 5 microunits/ml. This method correlates highly with radioimmunoassay, with coefficient of correlation r = 0.95.

Enzyme-Linked Immunosorbent Assay↗

Laser fluorometric determination of aflatoxin B1 in corn.

A 2-step chromatographic separation, using both thin layer chromatography (TLC) and high pressure liquid chromatography (HPLC), in conjunction with the high sensitivity of laser fluorometry permits extension of the detection limits of aflatoxin contamination in corn to 0.1 ppb (microgram/kg) with a 26% root mean square variation. Aflatoxin B1 is extracted from corn with water-methanol and cleaned up by TLC. The recovery of aflatoxin from the TLC plates was linear from 10 to 1000 pg. Aflatoxin B1 is converted to the more highly fluorescent B2A derivative by treatment with 1N HCl. Experiments with aflatoxin B1 standard establish a constant conversion to B2A over approximately 3 orders of magnitude in B1 concentration. An extract of the B2A aflatoxin derivative is injected onto a reverse phase HPLC column. A flowing droplet of eluant is irradiated by an amplitude-modulated 325 nm He-Cd ion laser beam, and fluorescence from the droplet is detected by a lock-in amplifier in phase with the laser modulation. Several chromatograms are presented that demonstrate the capability of this procedure for removing interfering components in the corn extract.

Aflatoxins↗

Laser fluorimetry: subpicogram detection of aflatoxins using high-pressure liquid chromatography.

The use of high-pressure liquid chromatographic separation in conjunction with laser-induced fluorescence detection permits the analysis of trace fluorescent species at new limits of sensitivity. This technique was applied to the carcinogens aflatoxins B1, B2, G1, and G2, which were linearly quantitated to 7.5 x 10(-13) gram. The procedure consists of forming more fluorescent aflatoxin derivatives, eluting the aflatoxins from a reverse-phase column, focusing the 325-nanometer output of a helium-cadmium ion laser into a suspended droplet of the eluent, and measuring the resulting fluorescence using phase-sensitive detection.

Aflatoxins↗