Search PubMed⌕ Search

Biomedical subjects

R Muthupillai

Publications and source records attributed to R Muthupillai.

9 recordsLinked to original sources

Magnetic resonance elastography of skeletal muscle.

While the contractile properties of skeletal muscle have been studied extensively, relatively little is known about the elastic properties of muscle in vivo. Magnetic resonance elastography (MRE) is a phase contrast-based method for observing shear waves propagating in a material to determine its stiffness. In this work, MRE is applied to skeletal muscle under load to quantify the change in stiffness with loading. A mathematical model of muscle is developed that predicts a linear relationship between shear stiffness and muscle load. The MRE technique was applied to bovine muscle specimens (N = 10) and human biceps brachii in vivo (N = 5). Muscle stiffness increased linearly for both passive tension (14.5 +/- 1.77 kPa/kg) and active tension, in which the increase in stiffness was dependent upon muscle size, as predicted by the model. A means of noninvasively assessing the viscoelastic pro-perties of skeletal muscle in vivo may provide a useful method for studying muscle biomechanics in health and disease.

Animals↗

FLAIR histogram segmentation for measurement of leukoaraiosis volume.

The purposes of this study were to develop a method to measure brain and white matter hyperintensity (leukoaraiosis) volume that is based on the segmentation of the intensity histogram of fluid-attenuated inversion recovery (FLAIR) images and to assess the accuracy and reproducibility of the method. Whole-head synthetic image phantoms with manually introduced leukoaraiosis lesions of varying severity were constructed. These synthetic image phantom sets incorporated image contrast and anatomic features that mimicked leukoaraiosis found in real life. One set of synthetic image phantoms was used to develop the segmentation algorithm (FLAIR-histoseg). A second set was used to measure its accuracy. Test retest reproducibility was assessed in 10 elderly volunteers who were imaged twice. The mean absolute error of the FLAIR-histoseg method was 6.6% for measurement of leukoaraiosis volume and 1.4% for brain volume. The mean test retest coefficient of variation was 1.4% for leukoaraiosis volume and 0.3% for brain volume. We conclude that the FLAIR-histoseg method is an accurate and reproducible method for measuring leukoaraiosis and whole-brain volume in elderly subjects.

Aged↗

Acoustic shear-wave imaging using echo ultrasound compared to magnetic resonance elastography.

We compare a previously developed phase contrast-based magnetic resonance imaging technique (MRE) to a phase-based ultrasound (US) method for measuring small cyclic displacements (submicrometer level) caused by propagating acoustic shear waves in tissue-like media. Our preliminary experiments with gelatin phantoms show that acoustic shear-wave propagation can be measured with US, and we speculate that this technique could find applications in medical imaging.

Humans↗

Segmented spin-echo pulses to increase fMRI signal: repeated intrinsic diffusional enhancement.

Since its inception, functional magnetic resonance imaging (fMRI) has seen rapid progress in the application to neuroscience. Common gradient-recalled acquisition methods are susceptible to static field inhomogeneities, resulting in signal loss at the medial temporal area important for memory function or at the basal ganglia area for motor control. In addition, they are susceptible to the contaminating signals of large vein origin, such as the signals from its surrounding cerebrospinal fluid (CSF) leading to false-positive activation. Spin echoes overcome these drawbacks. However, they are less sensitive to blood oxygenation level dependent (BOLD) susceptibility changes because of their refocusing mechanism. A method is presented here to enhance the spin-echo fMRI signal by recruiting more spins to participate in the dynamic BOLD process. This method divided a conventional T(2) weighting period into several segments separated by blocks of extra free diffusion time. Before the extra diffusion time spins are restored to the longitudinal axis preventing rapid transverse relaxation. This process allows more spin access to the regions that experience the BOLD field gradient. Because of the increased spin population that is modulated by the capillary BOLD field gradient, the functional signal is increased. Spin-echo echo-planar imaging (EPI) with this enhancement may be a useful technique for fMRI studies at inhomogeneous areas such as the air/tissue interface. Magn Reson Med 42:631-635, 1999.

Brain↗

An orthogonal correlation algorithm for ghost reduction in MRI.

Ghosting in MRI due to modulation of k-space data can be caused by motion of the subject or characteristics of the sequence. A general solution for 2DFT MRI that reduces ghosting without causal modeling is presented. Separate image data sets are acquired in which the phase and frequency directions are swapped. In these two data sets, the image signal is correlated, whereas the ghost signals are not. By taking a correlation of these two data sets, an image with greatly reduced ghosting is obtained. The reduction is shown to depend both on the correct signal intensity of the image, as well as the ghost intensity in the ghosted region. The reduction approaches 100% in regions of low image signal, and is more moderate in regions of higher image signal. The process was applied to conventional spin-echo, fast-spin-echo, and gradient echo imaging of volunteers and a phantom. Results of a reader study of the volunteer images reflected a significant overall reduction of ghosting artifacts in all volunteer experiments.

Abdomen↗

Magnetic resonance imaging of transverse acoustic strain waves.

We describe a phase contrast based MRI technique with high sensitivity to cyclic displacement that is capable of quantitatively imaging acoustic strain waves in tissue-like materials. A formalism for considering gradient waveforms as basis functions to measure arbitrary cyclic motion waveforms is introduced. Experiments with tissue-like agarose gel phantoms show that it is possible to measure small cyclic displacements at a submicron level by an appropriate choice of the applied gradient basis function and to use this capability to observe the spatial and temporal pattern of displacements caused by acoustic strain waves. The propagation characteristics of strain waves are determined by the mechanical properties of the media. It is therefore possible to use this technique to noninvasively estimate material properties such as elastic modulus.

Acoustics↗

Magnetic resonance elastography by direct visualization of propagating acoustic strain waves.

A nuclear magnetic resonance imaging (MRI) method is presented for quantitatively mapping the physical response of a material to harmonic mechanical excitation. The resulting images allow calculation of regional mechanical properties. Measurements of shear modulus obtained with the MRI technique in gel materials correlate with independent measurements of static shear modulus. The results indicate that displacement patterns corresponding to cyclic displacements smaller than 200 nanometers can be measured. The findings suggest the feasibility of a medical imaging technique for delineating elasticity and other mechanical properties of tissue.

Acoustic Stimulation↗

Diffusion-weighted MR imaging of the normal human spinal cord in vivo.

BACKGROUND AND PURPOSE: Diffusion-weighted imaging is a robust technique for evaluation of a variety of neurologic diseases affecting the brain, and might also have applications in the spinal cord. The purpose of this study was to determine the feasibility of obtaining in vivo diffusion-weighted images of the human spinal cord, to calculate normal apparent diffusion coefficient (ADC) values, and to assess cord anisotropy. METHODS: Fifteen healthy volunteers were imaged using a multi-shot, navigator-corrected, spin-echo, echo-planar pulse sequence. Axial images of the cervical spinal cord were obtained with diffusion gradients applied along three orthogonal axes (6 b values each), and ADC values were calculated for white and gray matter. RESULTS: With the diffusion gradients perpendicular to the orientation of the white matter tracts, spinal cord white matter was hyperintense to central gray matter at all b values. This was also the case at low b values with the diffusion gradients parallel to the white matter tracts; however, at higher b values, the relative signal intensity of gray and white matter reversed. With the diffusion gradients perpendicular to spinal cord, mean ADC values ranged from 0.40 to 0.57 x 10(-3) mm2/s for white and gray matter. With the diffusion gradients parallel to the white matter tracts, calculated ADC values were significantly higher. There was a statistically significant difference between the ADCs of white versus gray matter with all three gradient directions. Strong diffusional anisotropy was observed in spinal cord white matter. CONCLUSION: Small field-of-view diffusion-weighted images of the human spinal cord can be acquired in vivo with reasonable scan times. Diffusion within spinal cord white matter is highly anisotropic.

Adult↗