Optimization of planar high-dose-rate implants.

PURPOSE: Brachytherapy has long been used to deliver localized radiation to the breast and other cancer sites. For interstitial implants, proper source positioning is critical in obtaining satisfactory dose distributions. The present work examines techniques for optimizing source guide placement in high-dose-rate (HDR) biplanar implants, and examines the effects of suboptimal catheter placement. METHODS AND MATERIALS: Control of individual dwell times in HDR implants allows a high degree of dose uniformity in planes parallel to the implant planes. Biplanar HDR implants can be considered optimized when the dose at the implant center is equal to the dose at the symmetric target boundaries. It is shown that this optimal dose uniformity is achieved when the interplanar separation is related to the target thickness T through the direct proportionality, s = T/square root2. To quantify the significance of source positioning, the average dose and a related quantity, equivalent uniform dose (EUD), were calculated inside the treatment volume for two conditions of suboptimal catheter geometry. In one case, the interplanar spacing was varied from 1 cm up to the target thickness T, while a second study examined the effects of off-center placement of the implant planes. RESULTS: Both the average dose and EUD were minimized when the interplanar spacing satisfied the relationship s = T/square root2. EUD, however, was significantly smaller than the average dose, indicating a reduced relative cell killing in the high dose regions near the dwell points. It was also noted that in contrast to the average dose, the EUD is a relatively weak function of catheter misplacement, suggesting that the biological consequences of suboptimal implant geometry may be less significant than is indicated by the increase in average dose. CONCLUSION: A concise formula can be used to determine the interplanar separation needed for optimal dose uniformity in Manchester-type implants. Deviations from optimal source geometry result in an increase in the average dose inside the treatment volume, but the weaker dependence of the EUD suggests that the surviving fraction of cells may not be not strongly affected by suboptimal source geometry.

Algorithms↗

Towards subunit-specific proteasome inhibitors: synthesis and evaluation of peptide alpha',beta'-epoxyketones.

BACKGROUND: The proteasome is a large multicatalytic protease complex (700 kDa) involved in a number of highly regulated processes. It has three major catalytic activities: a chymotrypsin-like activity, a trypsin-like activity and a post-glutamyl peptide hydrolyzing (PGPH) activity. To be useful as molecular probes, which could help dissect the cellular functions of the proteasome, inhibitors should be specific for the proteasome, active in vivo and selectively block only one of the three catalytic activities. To date, few inhibitors fulfill these requirements so we set out to make novel proteasome inhibitors that incorporate these characteristics. RESULTS: A panel of amino-terminally acetylated peptide alpha',beta'-epoxyketones with leucine in P1 and various aliphatic or aromatic amino acids in P2-P4 were prepared and evaluated. Most compounds selectively inhibited the chymotrypsin-like activity, while only weakly inhibiting the trypsin-like and PGPH activities. After optimization, one inhibitor, Ac-hFLFL-epoxide, was found to be more potent and selective for the inhibition of the chymotrypsin-like activity than several previously described inhibitors. This inhibitor also exhibited strong in vivo anti-inflammatory activity. CONCLUSIONS: Optimization of amino-terminally acetylated peptide alpha',beta'-epoxyketones furnished a potent proteasome inhibitor, Ac-hFLFL-epoxide, that has an excellent selectivity for the chymotrypsin-like activity. The inhibitor also proved to be a potent antiproliferative and anti-inflammatory agent. The strong in vivo and in vitro activities suggest that this class of proteasome inhibitors could be both molecular probes and therapeutic agents.

Animals↗

Comparison of EGS4 and MCNP4b Monte Carlo codes for generation of photon phase space distributions for a Varian 2100C.

Monte Carlo based dose calculation algorithms require input data or distributions describing the phase space of the photons and secondary electrons prior to the patient-dependent part of the beam-line geometry. The accuracy of the treatment plan itself is dependent upon the accuracy of this distribution. The purpose of this work is to compare phase space distributions (PSDs) generated with the MCNP4b and EGS4 Monte Carlo codes for the 6 and 18 MV photon modes of the Varian 2100C and determine if differences relevant to Monte Carlo based patient dose calculations exist. Calculations are performed with the same energy transport cut-off values. At 6 MV, target bremsstrahlung production for MCNP4b is approximately 10% less than for EGS4, while at 18 MV the difference is about 5%. These differences are due to the different bremsstrahlung cross sections used in the codes. Although the absolute bremsstrahlung production differs between MCNP4b and EGS4, normalized PSDs agree at the end of the patient-independent geometry (prior to the jaws), resulting in similar dose distributions in a homogeneous phantom. EGS4 and MCNP4b are equally suitable for the generation of PSDs for Monte Carlo based dose computations.

Algorithms↗

Crystallographic analysis of potent and selective factor Xa inhibitors complexed to bovine trypsin.

Factor Xa is a serine protease which activates thrombin (factor IIa) and plays a key regulatory role in the blood-coagulation cascade. Factor Xa is, therefore, an important target for the design of anti-thrombotics. Both factor Xa and thrombin share sequence and structural homology with trypsin. As part of a factor Xa inhibitor-design program, a number of factor Xa inhibitors were crystallographically studied complexed to bovine trypsin. The structures of one diaryl benzimidazole, one diaryl carbazole and three diaryloxypyridines are described. All five compounds bind to trypsin in an extended conformation, with an amidinoaryl group in the S1 pocket and a second basic/hydrophobic moiety bound in the S4 pocket. These binding modes all bear a resemblance to the reported binding mode of DX-9065a in bovine trypsin and human factor Xa.

Animals↗

Correlated histogram representation of Monte Carlo derived medical accelerator photon-output phase space.

We present a method for condensing the photon energy and angular distributions obtained from Monte Carlo simulations of medical accelerators. This method represents the output as a series of correlated histograms and as such is well-suited for inclusion as the photon-source package for Monte Carlo codes used to determine the dose distributions in photon teletherapy. The method accounts for the isocenter-plane variations of the photon energy spectral distributions with increasing distance from the beam central axis for radiation produced in the bremsstrahlung target as well as for radiation scattered by the various treatment machine components within the accelerator head. Comparison of the isocenter energy fluence computed by this algorithm with that of the underlying full-physics Monte Carlo photon phase space indicates that energy fluence errors are less than 1% of the maximum energy fluence for a range of open-field sizes. Comparison of jaw-edge penumbrae shows that the angular distributions of the photons are accurately reproduced. The Monte Carlo sampling efficiency (the fraction of generated photons which clear the collimator jaws) of the algorithm is approximately 83% for an open 10x10 field, rising to approximately 96% for an open 40x40 field. Data file sizes for a typical medical accelerator, at a given energy, are approximately 150 kB, compared to the 1 GB size of the underlying full-physics phase space file.

Computer Simulation↗

Validation of Monte Carlo generated phase-space descriptions of medical linear accelerators.

The accuracy of Monte Carlo codes in dose calculation systems relies on the correctness of the input data. Monte Carlo calculations are performed to generate phase-space descriptions of the Varian 2100C accelerator at 6 and 18 MeV. Before these data can be reliably used as the input for dose calculations in patients, they must be properly validated. This validation consists of three different stages: validation of the coding of the geometry, validation of the user code for the Monte Carlo code, and validation of calculated results. Geometric validation is performed by isolating and testing treatment head components independently. The user code is checked by testing for energy conservation and the variance reduction schemes incorporated into the user code are checked by comparison of results calculated with and without their employment. Validation of the phase-space description is performed by calculation of depth dose curves and lateral profiles for dose deposition in phantom, with difference plots used to illustrate any discrepancies. Calculated and experimental in-phantom output is also determined. After complete validation, the calculated data can then be reliably used as the input for dose calculations.

Biophysical Phenomena↗

Gelatinase B/lacZ transgenic mice, a model for mapping gelatinase B expression during developmental and injury-related tissue remodeling.

Matrix metalloproteinases (MMPs) drive normal tissue remodeling and are implicated in a wide range of pathologies. Although MMP activity is controlled at multiple levels, the primary regulation of MMP activity is transcriptional. The transcriptional promoter elements required for MMP gene expression in cultured cells have been defined, but this has not been extended to the in vivo situation. In this paper, we show that the DNA sequences between -522 and +19 of the rabbit gelatinase B gene (MMP-9) (as characterized in the transgenic mouse line 3445) constitute a minimal promoter that drives appropriate developmental and injury-induced reporter gene expression in transgenic mice. We further show that the expression and activity of three transcription factors (NF-kappaB, AP-2, and Sp1) that control the activity of the gelatinase B promoter are selectively induced in the epithelium migrating to heal a wound. Although promoter activity parallels expression of the endogenous gene in cell cultures, we show by several criteria that cell cultures cannot model many aspects of promoter regulation in vivo. This study reveals that the transgenic mouse line 3445 might be a useful model for investigating the regulation of gelatinase B expression in vivo and for identifying and characterizing new drugs that can control gelatinase B gene transcription.

Animals↗

A comparison of three stereotactic radiotherapy techniques; ARCS vs. noncoplanar fixed fields vs. intensity modulation.

PURPOSE: Linac arc based stereotactic radiotherapy is being used with increasing frequency to treat brain tumors. This approach can be used for single or fractionated treatments, and is typically carried out with circular collimators which are optimal for small, spherical targets. Treatment planning using fixed noncoplanar beams or intensity-modulated beams may enhance the ability to conform to irregularly shaped and/or large tumors, especially when combined with stereotactic localization. We compare the dose conformity and normal brain dose characteristics of three stereotactic techniques for various nonspherical target shapes. METHODS AND MATERIALS: Three intracranial test targets were constructed using a 3D treatment planning system after a patient underwent CT simulation. The targets included an ellipsoid with major axis dimensions of 4.0, 2.0, and 2.0 cm, a hemisphere with a diameter of 4.0 cm, and an irregularly shaped patient tumor with a maximum dimension of 5.3 cm. The following stereotactic techniques were compared for each target: a) 5 arcs as used in traditional linac radiosurgery/radiotherapy (noncoplanar arcs [ARCS]), b) 6 fixed noncoplanar custom blocked fields (3D), c) intensity modulation using 6 noncoplanar beams and a mini-multileaf collimator (intensity-modulated radiation therapy [IMRTI). Dose volume histograms were performed for each target/technique combination. RESULTS: For the ellipsoid, dose conformity is similar for all three techniques and normal brain isodose distributions are more favorable with the ARCS plan. For the hemisphere and irregular tumor targets, dose conformity and high/low isodose normal brain volumes are more favorable with the IMRT technique. CONCLUSIONS: For the targets described above, the intensity-modulated technique results in improved dose conformity and decreased dose to nontarget brain in high and low isodose regions as compared to the standard noncoplanar arc technique or noncoplanar fixed fields for the hemisphere and tumor targets. Intensity-modulated treatment delivery may allow for an increase in the therapeutic ratio for treating stereotactically defined large and/or irregularly shaped intracranial targets.

Brain Neoplasms↗

A feasibility study of automated inverse treatment planning for cancer of the prostate.

PURPOSE: The development of automated "inverse planning," utilizing intensity-modulated radiation therapy (IMRT) raises the question of whether this new technique can provide a practical and efficient means of dose escalation in conformal treatment of cancer of the prostate. The purpose of this feasibility study was to determine a single set of inverse-planning parameters that can be used for a variety of different prostate patient geometries to automatically generate escalated dose (> or = 81 Gy) IMRT plans that satisfy normal tissue constraints for rectal and bladder walls. METHODS: We studied a subset of the 46 patients who were previously treated at Memorial Sloan Kettering Cancer Center (MSKCC) to a total dose of 81 Gy using a 3D conformal approach. Six patients were selected for our study and replanned using an analytical inverse-planning algorithm (referred to as OPT3D) applied to 8 intensity modulated, co-axial radiation beams. A set of more than a dozen inverse planning parameters were adjusted by trial and error until the resulting dose distributions satisfied the critical organ dose-volume constraints imposed by our study rules (D30 < or = 75.6 Gy and D10 < or = 80 Gy for the rectal wall; D15 < or = 80 Gy for the bladder wall) for the sample of patients selected. The OPT3D-generated plans were compared to hand-generated BEV plans using cumulative DVH analysis. RESULTS: A single set of inverse-planning parameters was found that was able to automatically generate IMRT plans meeting all critical organ dose-volume constraints for all but one of the patients in our study. [The exception failed to meet bladder dose constraints for both IMRT and BEV methods, due to extensive overlap between the planning target volume (PTV) and bladder contours]. Based upon analysis of the cumulative dose-volume histogram (DVH) for the prostate PTV, the D95 (DX is defined such that x% of the volume receives a dose > or = DX), averaged over all patients, was approximately 81 Gy. The average D90 and mean dose values were 85 Gy and 93 Gy, respectively. Although a similar D95 was achieved using the BEV-generated plans, the D90 and mean dose values were substantially higher for the inverse planning (OPT3D) method. CONCLUSION: This limited "paper study" shows IMRT with inverse planning to be a promising technique for the treatment of prostate cancer to high doses. We determined a small set of inverse-planning parameter values that was able to automatically design intensity-modulated radiotherapy (IMRT) plans for a subset of 6 patients previously treated at MSKCC to 81 Gy using BEV planning techniques. With one minor exception, the resulting plans succeeded in meeting predetermined dose-volume constraints while at the same time allowing an increase in the mean dose and D90 to the prostate PTV. These 8 field plans also resulted in reduced dosage to the femoral heads. This automated technique is efficient in terms of planning effort and, with proper software for computer-controlled MLC, may be appropriate for clinical use. The clinical feasibility of this approach for a larger group of patients is currently under study.

Feasibility Studies↗

Proteolytic mechanisms in corneal ulceration and repair.

Corneal stromal ulceration is a devastating disorder that can cause blindness. Stromal ulceration was once thought to be a physical dissolution process, which even now is described as "melting." However, a major paradigm change occurred about 25 years ago with the demonstration of extracellular matrix-degrading activity associated with tissues isolated from ulcerating corneas. Recent studies have identified the enzymes involved as specific members of the matrix metalloproteinase (MMP) family. These studies have further provided evidence that MMPs participate at all stages of the ulcerative process, from formation of the initiating epithelial defect to ulcer resolution and repair. Roles for MMPs in these processes are discussed in this review. Studies on corneal ulceration provide basic information about failure to heal, which is useful for understanding mechanisms common to other organ systems besides the cornea.

Animals↗