The Arthur E. Mills oration--the right to live and the right to die.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to R Mitchell.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND: Implantable transvenous cardioverter-defibrillators offer a significant opportunity to decrease procedural morbidity and medical costs in the care of patients with life-threatening ventricular arrhythmias who otherwise would have required a sternotomy or thoracotomy for device insertion. The purpose of this study was to examine prospectively the safety, efficacy, and limitations associated with the use of a transvenously implanted, tiered-therapy cardioverter-defibrillator with antitachycardia pacing function in a consecutive population of 84 ventricular fibrillation (VF) and sustained ventricular tachycardia (VT) survivors. METHODS AND RESULTS: The index arrhythmia promoting transvenous cardioverter-defibrillator implantation was VF in 41 patients, VT in 27, and both VF and VT in 16. In each patient, transvenous defibrillation via a coronary sinus, a right ventricular, a superior vena caval, and/or a subcutaneous chest patch lead system was attempted. The pulsing methods used include two-electrode single-pathway pulsing or three-electrode dual-pathway simultaneous or sequential pulsing. A transvenous cardioverter-defibrillator was inserted if the defibrillation threshold (DFT) was < or = 20 J. Successful implantation of a transvenous cardioverter-defibrillator was possible in 80 of 84 (95%) patients. The mean implant DFT was 10.9 +/- 4.8 J. After cardioverter-defibrillator implantation, all patients were extubated in the operating room and sent to a standard telemetry ward for monitoring. No patient suffered a postoperative pulmonary complication or perioperative flurry of cardiac arrhythmias. Postoperative complications included lead dislodgments in eight, transient long thoracic nerve injury in one, asymptomatic left subclavian vein occlusion in two, asymptomatic small pericardial effusion in one, subcutaneous patch pocket hematomas in four, pulse generator pocket infection in one, and lead fracture in one. As experience was gained with the procedure, it was routine to discharge patients 3 days after surgery. The mean hospital stay was 6.0 +/- 2.4 days. Upon discharge, all patients returned to their prehospital activities including those with complications except for the patient with a pocket infection, who required intravenous antibiotic therapy. Patient survival using an intention-to-treat analysis was 98% over an 11 +/- 7-month follow-up period. During this time period, 31 of the 80 patients (39%) with transvenous lead systems were successfully treated by their device for sustained VT or VF. Antitachycardia pacing was used in 424 episodes of monomorphic VT and was successful in 371 (88%). All episodes of VF were aborted by the device. Antiarrhythmic drugs were used after device implantation in only eight of 80 patients (10%). CONCLUSIONS: Transvenous cardioverter-defibrillator implantation is practical in most candidates. Implant DFTs are usually low, surgical morbidity and postoperative complications are modest, therapy of VT and VF is efficient, and survival is excellent.
BACKGROUND: Multiprogrammable antiarrhythmia devices can treat monomorphic ventricular tachycardia (VT) with autodecremental overdrive pacing and/or with low-energy cardioversion. These two methods provide the opportunity to decrease patient discomfort typically experienced with high-energy pulses. Although both therapies are known to be effective, controversy persists over their relative safety and efficacy. METHODS AND RESULTS: The purpose of this study was to examine the safety and efficacy of autodecremental overdrive pacing and low-energy cardioversion in reproducibly terminating monomorphic VT in 24 patients with multiprogrammable antiarrhythmia devices. The protocol required that identical ECG morphology VT be reproducibly induced four times to assess the outcome of antitachycardia pacing and cardioversion twice for each patient in a randomized fashion. Each episode of VT was induced via the implanted device. Autodecremental overdrive pacing initially began with seven stimuli at 97% of the VT cycle length, decrementing by 10 msec per stimulus to a minimum coupling interval of 200 msec. If ineffective, autodecremental overdrive pacing was allowed to iterate three more times for a total of four pacing interventions. With each iteration, one stimulus was added to the pacing train. Similarly, with low-energy cardioversion, up to four therapeutic attempts were made, beginning with a 0.2-J pulse. If ineffective, pulse energy was increased to 0.4, 1.0, and finally 2.0 J. All interventions were automatic without human interference. VT (cycle length, 306 +/- 42 msec) was repeatedly terminated in 15 of 24 patients (63%) by autodecremental overdrive pacing and in 18 of 24 patients (75%) by low-energy cardioversion (p = 0.53). Eight of the 24 patients (33%) had their VT terminated repeatedly by both therapies. VT accelerated to faster VT or ventricular fibrillation by autodecremental overdrive pacing in four of 24 patients (17%) and by low-energy cardioversion in five of 24 (21%) (p = 0.88). Only one of the 24 patients (4%) accelerated with both therapies. No patient was unaffected by either therapy. CONCLUSIONS: In the manner programmed, autodecremental overdrive pacing and low-energy cardioversion have similar efficacy and acceleration rates. Response to one therapy does not predict response to the other.
BACKGROUND: Transvenous implantable cardioverter-defibrillators provide significant advantages in the treatment of patients with life-threatening ventricular arrhythmias. However, present technology requires considerable electrophysiology expertise, multiple incisions, and long operative times for successful implementation. METHODS AND RESULTS: In this study, we present a prototype of a new, easy-to-insert unipolar transvenous defibrillation system that has the reliability of epicardial defibrillation but the ease of pacemaker insertion. This system incorporates a single anodal right ventricular defibrillation electrode using a 65% tilt biphasic pulse delivered to a 108-cm2 surface area pulse generator titanium alloy shell as an active cathode placed in a left infraclavicular pocket. Testing of this system was performed before implantation of a standard nonthoracotomy-transvenous defibrillation system in 40 consecutive patients with a history of ventricular tachycardia or fibrillation. The simplified unipolar single-lead system resulted in a defibrillation threshold of 9.3 +/- 6.0 J with 37 of 40 patients (93%) having a defibrillation threshold of less than 20 J. Moreover, the unipolar defibrillation system was efficiently used requiring only 3.4 +/- 0.8 ventricular fibrillation inductions to measure the defibrillation threshold and 100 +/- 28 minutes to implement. CONCLUSIONS: This new unipolar transvenous defibrillation system is as simple to insert as a pacemaker, requires few ventricular fibrillation inductions, demands less technical expertise, and provides defibrillation at energy levels comparable to that reported with epicardial lead systems. It should substantially reduce the morbidity, time, and cost of defibrillator implantation.
The presence of antibodies inhibitory to ACTH-stimulated cortisol secretion was investigated in patients with Addison's disease. In preliminary experiments, immunoglobulin G (IgG) samples from patients with Addison's disease and control subjects were prepared using diethylaminoethyl-cellulose ion exchange chromatography. Twelve of 29 Addison's IgGs and 1 of 3 control IgGs inhibited ACTH-stimulated cortisol secretion in an in vitro guinea pig adrenal cell bioassay. All but 1 of the samples that inhibited ACTH-stimulated cortisol secretion also inhibited dibutyryl cAMP-stimulated steroidogenesis. IgGs purified by protein-G immunoaffinity were similarly screened for inhibition of ACTH-stimulated cortisol secretion; samples from 5 controls and 5 patients with Graves' disease were without effect, and IgGs from only 2 of 25 patients with Addison's disease decreased ACTH bioactivity (by < 12%). The effects of the IgGs on ACTH bioactivity in vitro were not concentration dependent. Our results suggest that Addison's disease is not caused by circulating antibodies to the ACTH receptor. The inhibitory effects seen with IgG prepared by diethylaminoethyl ion exchange chromatography were most likely attributable to the effects of non-IgG components in the preparations.
Phorbol ester-induced release of LH and GH from rat anterior pituitary tissue in vitro is differentially inhibited by some, but not other, inhibitors of protein kinase C (PKC), suggesting that pharmacologically distinct species of PKC may have different functional roles in these cells. Since stimulus-induced anterior pituitary hormone release can be enhanced by oestradiol-17 beta (OE2) pretreatment, we investigated the effect of OE2 treatment of long-term (4 weeks) ovariectomized rats on the amount, activity and cellular actions of pharmacologically distinct PKC species in rat anterior pituitary tissue. Here we report that OE2 treatment enhanced phorbol 12,13-dibutyrate (PDBu)-induced LH but not GH release measured in vitro. This effect of OE2 on LH release may involve synthesis of additional PKCs that are not targeted by the synthetic diacylglycerol, 1,2-dioctanoyl-sn-glycerol (DOG). Measurements of anterior pituitary PKC activity and [3H]phorbol ester-binding studies suggested that the facilitatory action of OE2 on LH release may occur, at least in part, by altering the quantity and activity of PKC(s). Our results also demonstrate that the OE2-induced PKC(s) which facilitate LH release may be of the type that are not dependent upon raised intracellular Ca2+ for their activation and display distinct pharmacological properties (being readily activated by PDBu, but not by DOG, and are staurosporine-sensitive but H7-insensitive). This facilitatory action of OE2 on PKC-induced LH release does not appear to involve OE2-induced changes in the affinity of existing PKC(s) for PDBu, or changes in the amount of releasable LH in the pituitary prior to the stimulus.
The gel test, first reported in 1988, can be used for most areas of blood group serology, but this report deals specifically with ABO/Rh typing and antibody screening and investigation. The technique is simple and quick to perform and the reading of results is standardised and clean with no false-positive reactions being found in antiglobulin tests. Since gel anti-human globulin tests require no washing and the test cards may be sealed during centrifugation, the system is particularly advantageous for 'loosely bound' antibodies and 'high-risk' samples.
To study hypothalamo-pituitary-adrenal axis disturbances in chronic renal failure, we administered corticotrophin-releasing hormone to patients undergoing haemodialysis and CAPD and to normal controls. Cortisol, ACTH, and ACTH precursors were measured before and after corticotrophin-releasing hormone using sensitive and specific two-site assays. Baseline ACTH and cortisol were similar in all groups. Peak values occurred at 30 min (ACTH) and between 30 and 60 min (cortisol). The cortisol (but not the ACTH) responses were significantly reduced in patients with renal failure (P < 0.05). ACTH precursors did not change from baseline following corticotrophin-releasing hormone but were significantly elevated in patients with renal failure compared to controls (P < 0.01). The reduced cortisol response to corticotrophin-releasing hormone may reflect a primary defect of adrenal function in renal failure.
There is considerable doubt as to the importance of reduced plasminogen (PLG) activity as a risk factor for venous thrombosis. In the present study we have identified a wide range of PLG activities (25-200%) in a cohort of 9,611 blood donors. Males and females not taking hormonal contraceptives show a similar distribution of PLG, however, variation related to age appears to follow a different pattern in males and females. These differences are of doubtful clinical importance as are differences related to smoking. In contrast, females taking hormonal contraceptives or hormone replacement therapy (HRT) have up to 25% higher mean PLG levels in younger females but a less marked elevation (10%) is seen in 40-50 year olds. A PLG activity < 65% was recorded in 61 donors, none of whom appeared to have a history of thrombosis. These findings do not support the notion that reduced PLG is an important thrombophilic risk factor, however, further investigation of the donors with low PLG is required.
Explore the source record for details and available documents.
Protonation changes accompanying conversion of oxidised (O state) cytochrome c oxidase to the 2-electron-reduced P state, and 3-electron-reduced F state at pH 8.0 have been measured. It was found that 2 and 3 protons, respectively, were taken up. The fourth proton required for the reduction of O2 to H2O must therefore be consumed in the remaining F----O portion of the catalytic cycle.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Rate constants of cyanide binding to 'fast' oxidase have been measured in the fully-oxidised (O), peroxy (P) and ferryl (F) states at pH 8.0. Values of 2.2, 8 and 10 M-1 s-1, respectively, were obtained. Thus, none of these states appears to exhibit a rate that would identify it as the species responsible for the extremely rapid cyanide binding observed during turnover. On the other hand, with 'oxidised' enzyme as prepared, containing a very small fraction of one-electron-reduced (E state) oxidase, a corresponding fraction of enzyme exhibited spectral changes consistent with cyanide binding with a rate constant in excess of 10(4) M-1 s-1. Evidence is presented suggesting that mediation of electron transfer from one-electron-reduced, cyanide-liganded enzyme to free, ferric oxidase, rather than a global protein conformational change of the enzyme, is responsible for the greatly enhanced cyanide binding rates seen in the presence of cytochrome c or poly(L-lysine). Inter-oxidase electron exchange in 'oxidised' enzyme can result in a complicated dependence of the binding rate on cyanide concentration. We have demonstrated that this may give rise to a saturation of the rate of cyanide binding.
Modified heterocyclic phenylalanine analogues designed as replacements for the P3-P4 region were synthesized and incorporated into renin inhibitors. These inhibitors were found to have significant activity versus human recombinant renin, as well as in vivo activity. The compounds proved to be very resistant to chymotrypsin degradation, as exemplified by compound 8, which remained greater than 60% intact after a 24-h exposure to chymotrypsin. In contrast, the Boc-Phe analogue was nearly completely degraded after 1 h. Compound 6 proved to be the most potent renin inhibitor with an IC50 = 8.9 nM. These stable cyclized phenylalanines should prove to be generally useful as a substitute for Boc-Phe in protease inhibitors.
Small-angle X-ray and neutron scattering have been used to characterize the solution structure of rabbit skeletal phosphorylase kinase. The radius of gyration of the unactivated holoenzyme determined from neutron scattering is 94 A, and its maximum dimension is approximately 275-295 A. A planar model has been constructed that is in general agreement with the dimensions of the transmission electron microscope images of negatively stained phosphorylase kinase and that gives values for the radius of gyration, maximum linear dimension, and a pair distribution function for the structure that are consistent with the scattering data.
An assay based on the inhibition of syncytium formation in C8166 cells was developed to measure low levels of neutralising antibody (NT-AB) to human immunodeficiency virus (HIV) and to detect cross-reactivity between virus strains. The relationship between virus challenge and antibody titre was represented by a tripartite curve which was essentially linear over moderate levels of virus input. Based on these findings, antibody titres were standardised against 100 TCID50 of challenge virus. However, lower virus inocula were found to detect minimum levels of antibody. Reproducibility of antibody titres between tests was high, with variation generally lying within one dilution step. The improved sensitivity of the technique allowed detection of NT-ABs in animals immunised with immune-stimulating complexes (ISCOMS) incorporating HIV antigens. Consistent levels of cross-reactivity between HIV strains was demonstrated, indicating the presence of distinct viral groups, from which dominant isolates may be chosen for use in vaccination studies.